BSI PD CISPR/TR 30-1:2012
$142.49
Test method on electromagnetic emissions – Electronic control gear for single- and double-capped fluorescent lamps
Published By | Publication Date | Number of Pages |
BSI | 2012 | 24 |
This part of CISPR 30, which is a technical report, details, with the aid of reference luminaires, an independent method by which the radio disturbance characteristics of electronic control gear for fluorescent lamp luminaires with protection classes I and/or II may be compared against the requirements of CISPR 15.
This technical report covers electronic control gear for double-capped fluorescent lamps fitted with G5 or G13 lamp caps and to single-capped fluorescent lamps fitted with lamp caps: 2GX7, 2G8, 2G10, 2G11, 2GX13, G23, GX23, G24q, GX24q, GR8, and GR10q.
NOTE The above listing shows a typical selection of caps which are commonly used and does not lay claim to be exhaustive.
It is specifically applicable for equipment to be connected to 230 V ā 50 Hz mains power networks. For other power systems, modifications may be necessary.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
5 | FOREWORD |
7 | INTRODUCTION |
8 | 1 Scope 2 Normative references 3 Presumption of compliance |
9 | 4 Test method 5 Reference luminaire 5.1 Construction 5.2 Mounting and wiring schemes |
10 | 5.3 Grounding 5.4 Wiring |
11 | 6 Marking 7 Guidance for luminaire design TableĀ 1 ā Grounding connection overview for protection class I and class II applications |
12 | Annex A (informative) Mounting and wiring schemes Figures Figure A.1 ā Mounting and wiring scheme of a reference luminaire for two double-capped fluorescent lamps |
13 | FigureĀ A.2 ā Mounting and wiring scheme of a reference luminaire for two single-capped fluorescent lamps, two-sided electronic control gear terminals |
14 | FigureĀ A.3 ā Mounting and wiring scheme of a reference luminaire for two single-capped fluorescent lamps, single-sided electronic control gear terminals |
15 | Figure A.4 ā Mounting scheme of a reference luminaire for one, two, three or four double-capped fluorescent lamps |
16 | Figure A.5 ā Mounting scheme of a reference luminaire for one, two, three or four single-capped fluorescent lamps, two-sided electronic control gear terminals |
17 | Figure A.6 ā Mounting scheme of a reference luminaire for one, two, three or four single-capped fluorescent lamps, single-sided electronic control gear terminals |
18 | FigureĀ A.7 ā Mounting and wiring schema of a reference luminaire for four double-capped fluorescent lamps where the output terminals of the electronic control gear are positioned on both ends |
19 | FigureĀ A.8 ā Mounting and wiring schema of reference luminaires for one, two, three or four double-capped fluorescent lamps where the output terminals of the electronic control gear are positioned on both ends |
20 | FigureĀ A.9 ā Mounting and wiring schema of a reference luminaire for one circular-shaped fluorescent lamp, single-sided electronic control gear terminals |