BS ISO 6183:2022

$215.11

Fire protection equipment — Carbon dioxide extinguishing systems for use on premises — Design and installation

Published By Publication Date Number of Pages
BSI 2022 76
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 Foreword
8 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
11 3.21 Terms related to occupied and unoccupiable areas
12 4 Use and limitations
4.1 General
4.2 Uses for carbon dioxide systems
13 4.3 Limitations for carbon dioxide systems
4.4 Temperature limitations
5 Safety
5.1 Hazard to personnel
14 5.2 Safety precautions
5.2.1 Normally occupied and normally unoccupied areas
5.2.2 Warning notices for occupiable areas
17 5.2.3 Warning notices for unoccupiable areas
18 5.3 Electrical hazards
19 5.4 Electrical earthing
5.5 Electrostatic discharge
6 System design
6.1 General
6.1.1 Introduction
6.1.2 Specifications
20 6.1.3 Working documents
6.2 Carbon dioxide supply
6.2.1 Quality
6.2.2 Quantity
21 6.2.3 Container arrangement
22 6.2.4 Storage containers
24 6.3 Distribution
6.3.1 General
25 6.3.2 Piping
6.3.3 Fittings
6.3.4 Pipe and valve support
26 6.3.5 Valves
6.3.6 Nozzles
27 6.4 Enclosures (total flooding)
6.4.1 Structural strength
28 6.4.2 Loss through openings
6.4.3 Ventilation systems
6.5 Detection, actuation and control systems
6.5.1 General
6.5.2 Shut-down of plant and equipment
29 6.5.3 Automatic detection
6.5.4 Operating devices
30 6.5.5 Control equipment
31 6.5.6 Audible alarms and visual indicators
32 6.6 Local control (LC) and local control stations (LCS)
7 Carbon dioxide flow and concentration calculations
7.1 General
7.2 System flow calculations
7.2.1 General
33 7.2.2 Friction losses
7.2.3 Pressure drop
7.2.4 Valves and fittings
7.2.5 As-installed calculations
34 7.2.6 Specific requirements
7.3 Carbon dioxide concentration requirements
7.3.1 Flame extinguishment
7.3.2 Inerting
35 7.4 Total flooding quantity
7.4.1 General
7.4.2 Design quantity
7.4.3 KB factor
38 7.5 Design of local application systems
7.5.1 General
7.5.2 Carbon dioxide requirements
7.5.3 Rate by area method
40 7.5.4 Rate by volume method
41 7.6 Duration of protection — total flooding systems
42 7.7 System performance
7.7.1 Discharge time
7.7.2 Extended discharge
8 Commissioning and acceptance
8.1 General
8.2 Tests
8.2.1 General
43 8.2.2 Enclosure check
8.2.3 Review of mechanical components
44 8.2.4 Review of enclosure integrity
8.2.5 Review of electrical components
45 8.2.6 Preliminary functional tests
8.2.7 System functional operational test
46 8.2.8 Remote monitoring operations (if applicable)
8.2.9 Control panel primary power source
8.2.10 Completion of functional tests
8.3 Completion certificate and documentation
9 Inspection, maintenance, testing and training
9.1 General
47 9.2 Inspection
9.2.1 General
9.2.2 Container
9.2.3 Hose
9.2.4 Enclosures
9.3 Maintenance
9.3.1 General
48 9.3.2 User’s programme of inspection
9.3.3 Service schedule
9.4 Training
49 Annex A (normative) Working documents
56 Annex B (normative) Carbon dioxide system pipe and orifice size determination
64 Annex C (informative) System performance verification
65 Annex D (informative) General information on carbon dioxide
70 Annex E (informative) Examples of calculations
75 Bibliography