{"id":296075,"date":"2024-10-19T20:08:31","date_gmt":"2024-10-19T20:08:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-tr-183362016\/"},"modified":"2024-10-25T17:26:05","modified_gmt":"2024-10-25T17:26:05","slug":"bsi-pd-iso-tr-183362016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-tr-183362016\/","title":{"rendered":"BSI PD ISO\/TR 18336:2016"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1\tScope 2\tReagents <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3\tApparatus <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4\tFused glass beads 4.1\tGeneral 4.2\tStorage 4.3\tDisc making precision <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.4\tBead distortion (curvature and flatness) 5\tQuality control 5.1\tSelection of QC samples and frequency of preparation <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2\tAnalysis of QC and analytical samples 5.3\tControl charts <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.4\tParticipation in proficiency test programs <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex\u00a0A (informative) Results for flux loss on ignition testing <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex\u00a0B (informative) Procedure to check disc making precision <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Annex\u00a0C (informative) Method to determine relationship between height and concentration <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex\u00a0D (informative) Production of a height adjustable cup <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex\u00a0E (informative) Bead measurement apparatus <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex\u00a0F (informative) Flow sheet for fused bead quality <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex\u00a0G (informative) Microsoft Excel program for calculating disc precision <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex\u00a0H (informative) Data input screen for calculating disc precision <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Annex\u00a0I (informative) Loss of accuracy with no loss of precision <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex\u00a0J (informative) Loss of accuracy with loss of precision <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex\u00a0K (informative) Loss of accuracy and precision \u2014 Loss of bead making precision <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex\u00a0L (informative) Results for spectrometer precision test <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex\u00a0M (informative) Drift correction <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Guidelines for good XRF laboratory practice for the iron ore industry<\/b><\/p>\n |