{"id":435153,"date":"2024-10-20T07:48:00","date_gmt":"2024-10-20T07:48:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-58422023\/"},"modified":"2024-10-26T14:47:06","modified_gmt":"2024-10-26T14:47:06","slug":"bs-en-iso-58422023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-58422023\/","title":{"rendered":"BS EN ISO 5842:2023"},"content":{"rendered":"

This document specifies a gas chromatography and a mass spectrometry method of detecting the presence of argon in metal powder produced components, consolidated by hot isostatic pressing. This document specifies the calibration and functionality test for the equipment covered. It also specifies methods for sampling, sample preparation and sample test procedure of PM HIP components to detect argon presence. Components produced by additive manufacturing are not covered in this document.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nEuropean foreword
Endorsement notice <\/td>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
11<\/td>\n4 Equipment for argon detection
4.1 Gas chromatography
4.1.1 Principle
4.1.2 Apparatus and reagents <\/td>\n<\/tr>\n
12<\/td>\n4.1.3 Equipment detection limit
4.2 Mass spectrometry
4.2.1 Principle
4.2.2 Apparatus and reagents
4.2.3 Equipment detection limit <\/td>\n<\/tr>\n
13<\/td>\n5 Calibration and functionality test
5.1 General
5.2 Gas chromatograph
5.2.1 Calibration
5.2.2 Functionality test
5.3 Mass spectrometer
5.3.1 Calibration <\/td>\n<\/tr>\n
14<\/td>\n5.3.2 Functionality test
6 Sample preparation for argon detection
7 Test procedure for argon detection
7.1 General
7.2 Test procedure using gas chromatography <\/td>\n<\/tr>\n
15<\/td>\n7.3 Test procedure using mass spectrometry
8 Test report <\/td>\n<\/tr>\n
16<\/td>\nAnnex A (informative) Precision <\/td>\n<\/tr>\n
18<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Powder metallurgy. Hot isostatic pressing. Argon detection using gas chromatography and mass spectrometry techniques<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2023<\/td>\n20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":435163,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-435153","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/435153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/435163"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=435153"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=435153"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=435153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}