{"id":629831,"date":"2024-11-06T00:25:36","date_gmt":"2024-11-06T00:25:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iso-9386-12000\/"},"modified":"2024-11-06T00:25:36","modified_gmt":"2024-11-06T00:25:36","slug":"iso-9386-12000","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iso\/iso-9386-12000\/","title":{"rendered":"ISO 9386-1:2000"},"content":{"rendered":"

This part of ISO 9386 specifies the safety rules, dimensions and functional operation for permanently installed<\/p>\n

power-operated vertical lifting platforms intended for use by persons with impaired mobility when standing or sitting<\/p>\n

in a wheelchair, with or without an attendant.<\/p>\n

It specifies requirements for lifting platforms<\/p>\n

a) installed within enclosed liftways, and<\/p>\n

b) whose design or location permits their use without an enclosed liftway.<\/p>\n

It is restricted to the following lifting platforms:<\/p>\n

a) those which travel between fixed levels;<\/p>\n

b) those without liftway enclosure and without floor penetration:<\/p>\n

1) with travel up to 2,0 m,<\/p>\n

2) in private dwellings with travel up to 4,0 m;<\/p>\n

c) those with liftway enclosure with travel up to 4,0 m;<\/p>\n

d) those whose rated speed does not exceed 0,15 m\/s;<\/p>\n

e) those whose line of travel does not exceed 15\u00b0 from the vertical and;<\/p>\n

f) those whose rated load is not less than 250 kg.<\/p>\n

This part of ISO 9386 does not specify every general technical requirement for all aspects of the electrical,<\/p>\n

mechanical or building construction.<\/p>\n

As far as possible, this part of ISO 9386 specifies only the requirements that materials and equipment need to meet<\/p>\n

in the interests of safety and functional operation.<\/p>\n

Requirements are also included for protection against harmful influences which may be experienced by equipment<\/p>\n

installed in external locations.<\/p>\n","protected":false},"excerpt":{"rendered":"

Power-operated lifting platforms for persons with impaired mobility \u2014 Rules for safety, dimensions and functional operation \u2014 Part 1: Vertical lifting platforms<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ISO<\/b><\/a><\/td>\n2000-11<\/td>\n74<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":629844,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[174,1281,2634],"product_tag":[],"class_list":{"0":"post-629831","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-11-180-10","7":"product_cat-91-140-90","8":"product_cat-iso","10":"first","11":"instock","12":"sold-individually","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/629831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/629844"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=629831"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=629831"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=629831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}