Shopping Cart

No products in the cart.

ASCE 9780784473542 2010

$48.21

Significant Changes to the Seismic Load Provisions of ASCE 7-10

Published By Publication Date Number of Pages
ASCE 2010 209
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Significant Changes to the Seismic Load Provisions of ASCE 7-10: An Illustrated Guide focuses on the changes to the seismic load requirements of the newest edition of Minimum Design Loads for Buildings and Other Structures, Standard ASCE/SEI 7-10. The seismic load provisions have undergone many significant changes since the 2005 edition of ASCE 7. Generally following the organization of the seismic chapters in ASCE 7-10, this handy reference briefly summarizes each change to the seismic provisions that might affect actual practice and/or enforcement and then presents the precise wording of the change. The impact of a change is explained in clear, straightforward language accompanied by diagrams, examples, and color photographs or illustrations to enrich the reader

PDF Catalog

PDF Pages PDF Title
1 Cover
6 Table of Contents
10 Preface
12 Part I – Terminology Changes Affecting Multiple Sections & Chapters
13 Determination of Number of Stories: 11.1.2, 11.2, 11.3, 12.2.3.3, Table 12.6-1, 12.8.1.3, 12.8.2.1, Table 12.12-1, 12.13.6, 12.14.1.1, 12.14.8.1, 12.14.4.2.1
20 Nonstructural Components, Structural Members, and Elements: 1.4, 11.2, 11.7.1, 12.1.1, 12.2.4, 12.4.4, 12.5.3, 12.13.16, 12.14.4.2.3, 12.14.7, 14.1.1, 14.2.1, 14.3.1, 14.4.1, 15.7.3, 15.7.6.1, 15.7.6.1.4, 15.7.10.5, 15.7.11.6, 16.2.1, 16.2.4.2
22 Structural Height, h[sub(n)]: 11.2, 11.3, Table 12.2-1, 12.2.5.4, 12.2.5.6.1, 12.2.5.6.2, 12.2.5.7.1, 12.2.5.7.2, 12.2.5.7.3, 12.3.3.2, 12.8.2.1, Table 12.14-1, 12.14.8.5, 15.4.1, Table 15.4-1, Table 15.4-2, 15.5.3.8, 15.7.10.6, 17.4.1, 18.1.3, 18.5.2.3, 19.2.1.1
30 Overstrength Factor: 12.2.1, Table 12.2-1, 12.4.1, 12.4.3, 12.4.3.2, 12.14.3, 12.14.3.2, 12.14.3.2.2, 18.6.3, 18.7.1.3, 18.7.2.3
34 Seismic Load Effects Including Overstrength Factor: 12.2.5.2, 12.3.3.3, 12.3.3.4, 12.3.4.1, 12.10.2.1, 12.13.6.5, 12.13.6.6, 14.1.7, 14.2.3.2.2, 16.1.4, 16.2.4.1
39 Part II – Chapter 11 Seismic Design Criteria
40 MCE[sub(G)] Peak Ground Acceleration, Liquefaction Potential Evaluation: 11.2, 11.8.2, 11.8.3, 21.5.1, 21.5.2, 21.5.3, Chapter 22
45 Design Requirements for Seismic Design Category A: 1.4.2, 1.4.3, 1.4.4, 1.4.5, 11.7.1, 11.7.2, 11.7.3, 11.7.4, 11.7.5
47 What Qualifies as a Nonbuilding Structure?: 11.1.3
49 New Seismic Ground Motion Maps and Related Technical Changes: 11.2, 11.3, 11.4.1, 11.4.3, 11.4.5, 11.4.6, 21.2.1, 21.2.1.1, 21.2.1.2, 21.2.2, 21.2.3, Chapter 22, Figures 22-1 through 22-6
55 Part III – Chapter 12 Seismic Design Requirements for Building Structures
58 Design Coefficients and Factors for Seismic Force-Resisting Systems of Steel and Wood: Table 12.2-1
63 Design Coefficients and Factors for Autoclaved Aerated Concrete (AAC) Masonry Seismic Force- Resisting Systems: Table 12.2-1
65 Seismic Design of Cold-Formed Steel – Special Bolted Moment Frames: Table 12.2-1
69 R, C[sub(d)], and Ω[sub(0)] Values for Vertical Combinations: 12.2.3.1
71 Two-Stage Analysis Procedure: 12.2.3.2
73 Steel Cantilever Column Systems: 12.2.5.2, Table 12.2-1
76 Height Limit for Special Steel Plate Shear Walls: 12.2.5.4
77 Steel Ordinary Moment Frames and Steel Intermediate Moment Frames: 12.2.5.6, 12.2.5.6.1, 12.2.5.6.2, 12.2.5.7, 12.2.5.7.1, 12.2.5.7.2, 12.2.5.7.3, 12.2.5.8
82 Flexible Diaphragm Condition: 12.3.1.1
84 Horizontal Structural Irregularities: Table 12.3-1
86 Vertical Structural Irregularities Table 12.3-2
88 Redundancy Provisions: Table 12.3-3
90 Increase in Forces Due to Irregularities for Seismic Design Categories D through F: 12.3.3.4
92 Conditions where ρ is 1.0: 1 2.3.4.1
94 Allowable Stress Increase for Load Combinations with Overstrength: 12.4.3.3
96 Permitted Analytical Procedures: 12.6.1
99 Effective Seismic Weight: 12.7.2, 12.14.8.1, 15.3.1, 15.3.2, 15.4.3
102 Structural Modeling: 12.7.3
104 Minimum Design Base Shear: 12.8.1.1
107 S[sub(DS)], S[sub(D1)] in Seismic Response Coefficient Computation: 12.8.1.1
109 Approximate Fundamental Period: 12.8.2.1, Table 12.8-2
111 Approximate Period Equation Based on Number of Stories: 12.8.2.1
112 Amplification of Accidental Torsion: 12.8.4.3
113 Story Drift Determination: 12.8.6, 12.12.1
115 Minimum Base Shear for Computing Drift: 12.8.6.1
116 P-Delta Effects: 12.8.7
118 Combined Response Parameters: 12.9.3
120 Scaling of Drifts: 12.9.4, 12.9.4.1, 12.9.4.2
121 Diaphragm and Collector Design Forces: 12.4.3.1, 12.10.1.1, 12.10.2.1
124 Design for Out-of-Plane Forces: 12.11.1
125 Structural Separation and Property Line Setback: 11.3, 12.12.3, 12.14.8.5
128 Anchorage of Structural Walls and Transfer into Diaphragms: 1.4.5, 11.3, 12.11.2, 12.11.2.1, 12.14.7.5
133 Members Spanning between Structures: 12.12.4
135 Openings or Reentrant Building Corners: 12.14.7.2, Chapter 23
136 Part IV – Chapter 13 Seismic Design Requirements for Nonstructural Components
138 Component Importance Factor: 13.1.3
140 Exemptions for Nonstructural Components and Coefficients for Architectural Components: 13.1.4, Table 13.5-1
143 Definitions and Usage of Terms Related to Chapter 13, Including Friction Clip: 11.2, 13.1.6, 13.1.7, 13.4, Table 13.5-1, 13.6.1, 13.6.2
148 Reference Documents: 13.1.6
149 Applicable Requirements for Architectural, Mechanical, and Electrical Components, Supports, and Attachments; Special Certification Requirements for Designated Seismic Systems: 13.2.1, 13.2.2
151 Seismic Relative Displacement: 11.3, 13.3.2, 13.3.2.2
153 Design Force in Attachment and Anchors in Concrete or Masonry: 13.4.1, 13.4.2, 13.4.2.1, 13.4.2.2, 13.4.2.3
155 Power Actuated Fasteners: 13.4.5
156 Signs and Billboards: Table 13.5-1, Table 15.4-2
157 Suspended Ceilings: 13.5.6, 13.5.6.1, 13.5.6.2, 13.5.6.3, 13.5.8
161 Seismic Coefficients for Electrical Conduit, Bus Ducts, Cable Trays and Plumbing: Table 13.6-1
163 Chimneys and Stacks: Table 13.5-1, Table 13.6-1
165 Additional Requirements for Mechanical and Electrical Components: 13.6.5.5, 13.6.5.6
168 Ductwork: 13.6.7
170 Piping Systems: 13.6.8, 13.6.8.1, 13.6.8.2, 13.6.8.3, 13.6.9, 13.6.10, 13.6.11
174 Seismic Controls for Elevators: 13.6.10.3
176 Part V – Chapter 15 Seismic Design Requirements for Nonbuilding Structures
177 Stacks and Chimneys: 15.4.1, Table 15.4-2, 15.6.2
181 Steel Storage Racks: 15.5.3, 23.1
185 Anchors in Concrete or Masonry: 15.4.9, 15.7.3, 15.7.5, 15.7.11.7
188 Earth-Retaining Structures: 15.6.1
189 Freeboard, Height of Sloshing Wave: 15.6.5.1, 15.7.6.1.2
191 Value of T[sub(L)] in Design of Ground-Supported Tanks: 15.7.6.1
192 Water Storage and Water Treatment Tanks and Vessels of Reinforced and Prestressed Concrete: 15.7.7.3, 23.1
194 Welded Steel Petrochemical and Industrial Tanks and Vessels Storing Liquids, Refrigerated Gas Liquid Storage Tanks and Vessels: 15.7.8.1, 15.7.13.1, 23.1
196 Part VI – Chapter 16 Seismic Response History Procedures
197 Three-Dimensional Seismic Response History Analysis: 16.1.3.2
199 Response Parameters in Linear Response History Analysis: 16.1.4
200 Horizontal Shear Distribution in Linear Response History Analysis: 16.1.5
201 Part VII – Chapter 19 Soil-Structure Interaction for Seismic Design
202 Values of Shear Wave Velocity and Shear Modulus for Soil-Structure Interaction Analysis: Table 19.2-1
203 Foundation Damping Factor in Soil-Structure Interaction Analysis: Figure 19.2-1
204 Part VIII – Chapter 21 Site-Specific Ground Motion Procedures for Seismic Design
205 Deterministic Lower Limit on MCER Response Spectrum from Site Response Analysis: Figure 21.2-1
206 Design Acceleration Parameters from Site-Specific Ground Motion Procedures: 21.4
208 About the Authors
ASCE 9780784473542 2010