Shopping Cart

No products in the cart.

ASHRAE 189.3 2017

$37.38

ASHRAE 189.3-2017 – Construction, and Operation of Sustainable High-Performance Health Care Facilities (ASHE co-sponsored; ANSI Approved)

Published By Publication Date Number of Pages
ASHRAE 2017 28
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASHRAE/ASHE Standard 189.3 uses ASHRAE/USGBC/IES Standard 189.1 as a basis to address the sustainability of health care facilities. The purpose of the standard is to prescribe procedures, methods, and documentation requirements for the design, construction, and operation of high-performance, sustainable health care facilities.

PDF Catalog

PDF Pages PDF Title
1 ANSI/ASHRAE/ASHE Standard 189.3-2017
3 CONTENTS
4 FOREWORD
1. PURPOSE
2. SCOPE
2.1 This standard applies to patient care areas and related support areas within health care facilities, including hospitals, nursing facilities, outpatient facilities, and their site.
2.2 This standard applies to new buildings, additions to existing buildings, and those alterations to existing buildings that are identified within the standard.
2.3 This standard provides procedures for the integration of sustainable principles into the health care facility design, construction, and operation process, including
3. DEFINITIONS, ABBREVIATIONS, AND ACRONYMS
3.1 General. Certain terms, abbreviations, and acronyms are defined in this section for the purposes of this standard. These definitions are applicable to all sections of the standard.
3.2 Definitions
5 3.3 Abbreviations and Acronyms
4. ADMINISTRATION AND ENFORCEMENT
4.1 General. Building projects shall comply with Sections 5 through 11 of ASHRAE/USGBC/IES Standard 189.1 as modified in this standard through deletions of, exceptions to, or revisions to the provisions in Standard 189.1 and/or the inclusion in this …
4.2 Application to Buildings
4.3 Compliance
6 5. SITE SUSTAINABILITY
5.1 Scope. This section specifies requirements associated with the building site on which health care facilities are placed.
5.2 Compliance. The site shall comply with the provisions of Section 5 of ANSI/ASHRAE/USGBC/ IES Standard 189.1.
6. WATER USE EFFICIENCY
6.1 Scope. This section specifies requirements for potable and nonpotable water use efficiency, for both the site and the building, and for water metering.
6.2 Compliance. The water systems shall comply with the provisions of Section 6 of Standard 189.1 except as specifically deleted, excepted, modified, or enhanced in accordance with Sections 6.3 through 6.4. Site water use and building water use are n…
6.3 Mandatory Provisions
7 6.4 Prescriptive Option
7. ENERGY EFFICIENCY
7.1 Scope. This section specifies requirements for energy efficiency for buildings and appliances, for on-site renewable energy systems, and for energy measuring.
7.2 Compliance. The energy systems shall comply with the provisions of Section 7 of Standard 189.1 except as specifically deleted, excepted, modified, or enhanced in accordance with Sections 7.3 through 7.5.
7.3 Mandatory Provisions
7.4 Prescriptive Option
8 7.5 Performance Option
8. INDOOR ENVIRONMENTAL QUALITY (IEQ)
8.1 Scope. This section specifies requirements for indoor environmental quality, including indoor air quality, environmental tobacco smoke control, outdoor air delivery monitoring, thermal comfort, building entrances, acoustic control, daylighting, a…
8.2 Compliance. The indoor environmental quality shall comply with the provisions of Standard 189.1, Section 8, except as specifically deleted, excepted, modified, or enhanced in accordance with Sections 8.3 through 8.5.
8.3 Mandatory Provisions
9 8.4 Prescriptive Option
8.5 Performance Option
10 9. THE BUILDING’S IMPACT ON MATERIALS AND RESOURCES
9.1 Scope. This section specifies requirements for the building’s impact on the materials, and resources, including construction waste management, storage and collection of recyclables, and reduced impact materials.
9.2 Compliance. The building materials shall comply with the provisions of Standard 189.1, Section 9, except as specifically deleted, excepted, modified, or enhanced in accordance with Section 9.3 through 9.5 of this standard.
9.3 Mandatory Provisions
10. CONSTRUCTION AND PLANS FOR OPERATION
10.1 Scope. This section specifies requirements for construction and plans for operation including the commissioning process, building acceptance testing, measurement and verification, energy use reporting, durability, transportation management, eros…
10.2 Compliance. The construction and plans for operation shall comply with the provisions of Standard 189.1, Section 10, except as specifically deleted, excepted, modified, or enhanced in accordance with Sections 10.3 through 10.5 of this standard.
10.3 Mandatory Provisions
11 10.4 Prescriptive Option. There are no prescriptive options.
10.5 Performance Option. There are no performance options.
11. EMISSIONS, EFFLUENT, AND POLLUTION CONTROL
11.1 Scope. This section specifies requirements for emissions and effluent from building systems and equipment and pollution control relating to refrigerants, boilers, emergency backup generators, effluent flows, and waste streams.
11.2 Compliance. The building systems and operation practices shall comply with Sections 11.3 and 11.4.
11.3 Mandatory Provisions
12 11.4 Prescriptive Options
13 11.5 Performance Options. There are no performance options. See Informative Appendix K, Section K4.
14 12. NORMATIVE REFERENCES
20 INFORMATIVE APPENDIX I—INFORMATIVE REFERENCES
21 INFORMATIVE APPENDIX J—MATERIALS AND RESOURCES
J1. Recyclables
J2. Reusable Goods
J3. Building Project Commissioning
J4. Building Service Life Plan
J5. Hazard Chemical Management— Pharmaceuticals in Sanitary Sewer
J6. Waste Management Plan
J7. Regulated Medical Waste
J8. Hazard Chemical Management— Sanitary Sewer Disposal and Releases
J9. Hazard Chemical Management— Pharmaceuticals Management
22 INFORMATIVE APPENDIX K—EMISSIONS, EFFLUENT, AND POLLUTION CONTROL
K1. Medical Waste Incinerators
K2. Hazard Chemical Release Prevention— Leaks and Spills to Soil and Water
K3. Hazard Chemical Management—Radiology Chemicals Management
K4. Performance Options
K4.1 Solid Waste
K5. Elective Provisions
K5.1 Emissions
K5.2 Air Quality Standards for Boilers. Boilers less than or equal to 40 million Btu/h (42.2 million kJ/h) should meet the air quality standards thresholds as set forth in the SCAQMD Rule 1303 (see Table K5.2). All relevant documentation should be su…
K5.3 Emissions of Oxides of Nitrogen from Large Water Heaters and Small Boilers and Process Heaters. This standard applies to large water heaters, small boilers, and process heaters that have a rated heat input capacity less than or equal to 2 millio…
K5.4 Emissions of Oxides of Nitrogen from Small Industrial, Institutional, and Commercial Boilers; Steam Generators; and Process Heaters. This standard applies to boilers, steam generators, and process heaters that are greater than 2 million Btu/h (2…
23 K5.5 Solid Waste
ASHRAE 189.3 2017