E2309/E2309M-05(2011)e1 Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines

Published By Publication Date Number of Pages
ASTM 2011 6
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These practices cover procedures and requirements for the calibration and verification of displacement measuring systems by means of standard calibration devices for static and quasi-static testing machines. This practice is not intended to be complete purchase specifications for testing machines or displacement measuring systems. Displacement measuring systems are not intended to be used for the determination of strain. See Practice E83 .

1.2 These procedures apply to the verification of the displacement measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the displacement-measuring system(s) to be verified.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 Displacement values indicated on displays/printouts of testing machine data systems be they instantaneous, delayed, stored, or retransmitted which are within the Classification criteria listed in Table 1, comply with Practices E2309/E2309M.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
Calibration Devices
TABLE 1
3 System Verification
Application of Displacement
Selection of Verification Displacement Values
Preliminary Procedure
Procedure
4 Basis of Verification
Corrections
Time Interval Between Verifications
Accuracy Assurance Between Verifications
5 Report
Keywords
X1. DETERMINING RESOLUTION OF THE DISPLACEMENT INDICATOR
X1.1
X1.2
X1.3 Procedure for Analog Type Displacement Indicators
X1.4 Procedure for Non-Auto-Ranging Digital Type Dis-placement Indicators
6 X1.5 Procedure for Auto-Ranging Digital Type Displace-ment Indicators