BS EN 12098-5:2017
$142.49
Energy Performance of Buildings. Controls for heating systems – Start-stop schedulers for heating systems. Modules M3-5,6,7,8
Published By | Publication Date | Number of Pages |
BSI | 2017 | 26 |
This European Standard applies to scheduling equipment for heating systems. The signals can be processed by using either analogue or digital techniques, or both. It applies to start-stop scheduling functions and sets minimum acceptable standards for functions, performance and documentation. NOTE 1 The start-stop function can be integrated within a main control device. In this case, the controller would be expected to this standard for scheduling function. Safety requirements on heating systems and heating control systems remain unaffected by this European Standard. The actuators and the dynamic behaviour of the valves are not covered in this European Standard. This control equipment may or may not be connected to a data network. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in prEN ISO 52000-1. NOTE 2 In prCEN ISO/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 3 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
8 | 1 Scope |
10 | 2 Normative references 3 Terms and definitions |
13 | 4 Symbols, subscripts and abbreviations 4.1 Symbols 4.2 Subscripts 5 Functionality |
15 | 6 Requirements 6.1 Data protection |
16 | 6.2 Scheduler operating modes 6.3 Start-stop switch times 6.3.1 Timers |
17 | 6.3.2 Clock schedulers 6.3.3 Exception handling |
18 | 6.3.4 Start period |
19 | 6.3.5 Tariff compensation |
20 | 6.4 Parameter setting facilities 6.5 Factory settings 6.6 Switching output relays 6.7 Electrical requirements 6.7.1 General 6.7.2 Supply voltage 6.7.3 Protection against electric shock 6.7.4 Electromagnetic compatibility 6.7.5 Degree of protection 6.7.6 Electrical power consumption |
21 | 6.7.7 Environmentally induced stress due to temperature 6.7.8 Materials 6.8 Use of graphical symbols 7 Test methods 7.1 General 7.2 Data protection |
22 | 7.3 Scheduler operating modes 7.4 Start-stop switch times 7.4.1 General 7.4.2 Timers 7.4.3 Clock schedulers 7.4.4 Exception handling 7.4.5 Start period 7.4.6 Tariff compensation 7.5 Manual operation 7.6 Parameter setting facilities 7.7 Factory settings 8 Marking |
23 | 9 Documentation 9.1 Technical documents 9.2 Technical specifications |
24 | 9.3 Instruction for installation 9.4 Instruction for operator |