Windows and doors. Product standard, performance characteristics – Internal pedestrian doorsets

Published By Publication Date Number of Pages
BSI 2018 56
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets. Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034. This European Standard applies to doorsets intended to be used internally for construction works as: – intended use a) in escape routes; – intended use b) for specific uses with specific requirements; – intended use c) for communication only. NOTE 1 These above intended uses can be combined, for example escape routes with specific requirements. For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034. Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with: – related building hardware; – door closing devices; – integral fanlights; – adjacent parts that are contained within a single frame for inclusion in a single aperture. NOTE 2 Manually operated doors with door closing devices are not considered to be power operated doors. Products covered by this European Standard are not assessed for structural applications. This European Standard does not apply to: – industrial, commercial and garage doors and gates according to EN 13241; – external pedestrian doorsets according to EN 14351-1; – door leaves placed on the market as a single unit; – door frames placed on the market as a single unit; – power operated pedestrian doorsets, other than swing type, according to EN 16361. Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified. This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard.

PDF Catalog

PDF Pages PDF Title
2 undefined
9 1 Scope
10 2 Normative references
12 3 Terms, definitions and symbols
3.1 Terms and definitions
13 3.2 Symbols
14 4 Product characteristics
4.1 General
4.2 Release of dangerous substances (only for emissions into indoor air impact) (for intended use a, b and c)
4.3 Impact resistance (where relevant, only for glazed doors with injury risks) (for intended use a, b and c)
4.3.1 Glazed doors
4.3.2 Unframed glass doorsets
4.4 Height (for intended use a, b and c)
4.5 Reaction to fire
4.5.1 Reaction to fire of components (for intended use a, b and c)
15 4.5.2 Reaction to fire of the doorset
4.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b)
16 4.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses and specific requirements) (for intended use b)
4.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b)
4.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b)
4.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a)
4.11 Durability
4.11.1 Durability of air permeability against ageing/degradation for specific use with specific requirements (for intended use b):
4.11.2 Durability of operating forces (safety in use) against ageing/degradation (only for automatic devices and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b)
17 4.12 Width
4.13 Manual operating forces
4.14 Mechanical strength
4.15 Bullet resistance
4.16 Explosion resistance
4.17 Resistance to repeated opening and closing
4.18 Behaviour between two different climates
4.19 Burglar resistance
18 4.20 Safety requirements for power operated pedestrian hinged doorsets
4.21 Ventilation
5 Testing, assessment and sampling methods
5.1 General
5.2 Release of dangerous substances (only for emissions into indoor air impact) (for intended use a, b and c)
5.3 Impact resistance (where relevant, only for glazed doors with injury risks) (for intended use a, b and c)
5.4 Height (for intended use a, b and c)
19 5.5 Reaction to fire
5.6 Direct airborne sound insulation index (only for uses where acoustic performance is required) (for intended use b)
5.6.1 Reference method
5.6.2 Alternative method
5.7 Operating forces (only for automatic devices and only for internal landing communication doors and doors for special uses) (for intended use b)
5.8 Thermal transmittance (only for uses where thermal insulation performance is required) (for intended use b)
5.8.1 Reference method
20 5.8.2 Tabulation
5.8.3 Calculation
5.9 Air permeability (only for uses where air permeability performance is required for specific use with specific requirements) (for intended use b)
5.10 Ability to release (to open) (only for locked doors in escape routes) (for intended use a)
5.11 Durability
5.11.1 Durability of air permeability against ageing/degradation (for intended use b)
5.11.2 Durability of operating forces (only for automatic devices, and only for internal landing communication doors and doors for special uses with specific requirements) (for intended use b)
21 5.12 Width
5.13 Manual operating forces
5.14 Mechanical strength
5.15 Bullet resistance
5.16 Explosion resistance
5.17 Resistance to repeated opening and closing
5.18 Behaviour between two different climates
5.19 Burglar resistance
5.20 Safety requirements for power operated pedestrian hinged doorsets
22 5.21 Ventilation
6 Assessment and verification of constancy of performance – AVCP
6.1 General
6.2 Type testing
6.2.1 General
23 6.2.2 Test samples, testing and compliance criteria
6.2.3 Test reports
6.2.4 Shared other party results
24 6.2.5 Cascading determination of the product type results
25 6.3 Factory production control (FPC)
6.3.1 General
26 6.3.2 Requirements
6.3.2.1 General
27 6.3.2.2 Equipment
6.3.2.3 Raw materials and components
6.3.2.4 Traceability and marking
6.3.2.5 Controls during manufacturing process
6.3.2.6 Product testing and evaluation
6.3.2.7 Non-complying products
6.3.2.8 Corrective action
28 6.3.2.9 Handling, storage and packaging
6.3.3 Product specific requirements
6.3.4 Initial inspection of factory and of FPC
29 6.3.5 Continuous surveillance of FPC (only for products covered by AVCP system 1)
6.3.6 Procedure for modifications
6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity
30 7 Marking, Labelling and packaging
32 Annex A (informative)Product characteristics possibly affected by change of components
A.1 General
34 Annex B (normative)Tabulated values and extension of test results following size and design variations
B.1 Characteristics of internal pedestrian doorsets
36 B.2 Sound insulation index of internal pedestrian doorsets
37 B.3 Thermal transmittance for Internal pedestrian doorsets UD in accordance to constructive details
38 Annex C (informative)Example of performance and requirement profile of an Internal pedestrian doorsets
39 Annex D (informative)Examples for opening dimensions of internal pedestrian doorsets
41 Annex E (informative)Handling, installation, maintenance and care
42 Annex F (normative)Selection, preparation, mounting and fixing of test sample(s) for reaction to fire tests and field of direct application
F.1 General
F.2 EN ISO 119252 (Single flame test)
F.2.1 Profile
44 F.2.2 Infill or door leaf
F.2.3 Sealant between infill and profile
45 F.2.4 Organic coating/top layers
46 F.3 Mounting and fixing for EN 13823 (SBI-test)
F.3.1 Testing of the individual components
47 F.3.2 Testing of the doorset
48 F.4 EN ISO 1182 (Non-combustibility test)
F.5 EN ISO 1716 (Determination of the heat of combustion)
49 F.6 Field of direct application
50 Annex ZA(informative)Relationship of this European Standard with Regulation (EU) N°.305/2011
BS EN 14351-2:2018