Shopping Cart

No products in the cart.

BS EN 15882-2:2022

$189.07

Extended application of results from fire resistance tests for service installations – Fire dampers

Published By Publication Date Number of Pages
BSI 2022 48
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document provides guidance and rules to notified bodies (for fire dampers) allowing them to produce/validate an extended field of application report for fire dampers based on testing undertaken in accordance with EN 1366 2. This document identifies the parameters that affect the fire resistance of fire dampers. It also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction. This document explains the principles behind how a conclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E, I, S) can be achieved. This document does not cover dampers used for smoke control or non-mechanical fire barriers. It is the intention that the application of this document makes it possible to identify which specifications to test to maximize the field of application. Some information on test programmes is given for guidance purposes.

PDF Catalog

PDF Pages PDF Title
2 undefined
8 1 Scope
2 Normative references
9 3 Terms and definitions
4 Test requirements for assessment of design changes and modification of the manufacturing process
4.1 General
4.2 Design and manufacturing changes
4.2.1 Pre-test
10 4.2.2 Fire test
4.2.3 Extended field of application
4.3 Actuators, remote triggering devices, actuating mechanisms, fusible links and sensing elements
4.3.1 Actuators
4.3.1.1 General
4.3.1.2 Fire damper ambient cycle test
4.3.1.3 Confirmatory acceptance fire test
11 4.3.1.4 Field of application
4.3.2 Actuators with an associated thermal element device that controls the action of the actuator to close the fire damper in the event of fire
4.3.2.1 General
4.3.2.2 Fire damper ambient cycle test
4.3.2.3 Confirmation of the thermal element device
4.3.2.4 Confirmatory acceptance fire test
4.3.2.5 Field of application
12 4.3.3 Remote triggering device (e.g. magnet)
4.3.3.1 General
4.3.3.2 Fire damper ambient cycle test
4.3.3.3 Confirmatory acceptance fire test
4.3.3.4 Field of application
4.3.4 Actuating mechanism
4.3.4.1 General
13 4.3.4.2 Fire damper ambient cycle test
4.3.4.3 Confirmatory acceptance fire test
4.3.4.4 Field of application
4.3.5 Fusible links and elements (not associated with the actuator supplier)
4.3.5.1 General
14 4.3.5.2 Fire damper ambient cycle test
4.3.5.3 Confirmation of the fusible link or element
4.3.5.4 Confirmatory acceptance fire test
4.3.5.5 Field of application
5 Determination of worst case
15 6 Conditions and application rules
6.1 Change of fixing damper to supporting construction
6.2 Multiple damper assemblies
6.2.1 E Classification only
6.2.1.1 Method
16 6.2.1.2 Field of application
17 6.2.2 EI, E-S, EI-S classifications
6.2.2.1 Pre-qualification information and tests
6.2.2.2 EXAP fire resistance test method
6.2.3 Field of application
18 6.3 Alternative penetration seals
7 Influence of parameters and factors on fire damper performance
8 Critical parameters and factors
8.1 General
19 8.2 Common operational parameters and factors
9 Constructional parameters
9.1 General
20 9.2 Parameters of components of damper
21 9.3 Parameters for installation
10 Methodology
44 11 Extended field of application report
BS EN 15882-2:2022
$189.07