Shopping Cart

No products in the cart.

BS EN 60400:2017

$215.11

Lampholders for tubular fluorescent lamps and starterholders

Published By Publication Date Number of Pages
BSI 2017 100
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60400:2017 states the technical and dimensional requirements for lampholders for tubular fluorescent lamps and for starterholders, and the methods of test to be used in determining the safety and the fit of the lamps in the lampholders and the starters in the starterholders. This eighth edition cancels and replaces the seventh edition published in 2008, Amendment 1:2011 and Amendment 2:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – alignment with ISO/IEC drafting rules; – renumbering of clauses, tables and figures. This bilingual version (2017-12) corresponds to the monolingual English version, published in 2017-06. The French version of this standard has not been voted upon.

PDF Catalog

PDF Pages PDF Title
2 National foreword
9 CONTENTS
12 FOREWORD
14 1 Scope
2 Normative references
15 3 Terms and definitions
19 4 General requirement
20 5 General conditions for tests
21 6 Electrical rating
7 Classification
22 8 Marking
24 9 Protection against electric shock
26 10 Terminals
28 11 Construction
33 12 Resistance to dust and moisture
34 13 Insulation resistance and electric strength
Tables
Table 1 – Minimum values of insulation resistance
35 14 Endurance
36 15 Mechanical strength
38 16 Screws, current-carrying parts and connections
Table 2 – Torque tests on screws
40 17 Creepage distances and clearances
41 Table 3 – Minimum distances for AC sinusoidal voltages up to 30 kHz – Impulse withstand category II
42 18 Resistance to heat, fire and tracking
Table 4 – Minimum distances for rated ignition voltages or equivalent peak voltage UP
47 19 Resistance to excessive residual stresses (season cracking) and to rusting
48 Figures
Figure 1 – Mounting jig for the testing of lampholders
49 Figure 2 – Mounting sheet
50 Figure 3 – Fixture for the testing of lampholder flexibility
51 Figure 4 – Test caps G5, GX5 and G13
53 Figure 5 – Impact test apparatus and mounting support
54 Figure 6 – Test cap for the test of Clause 14 for lampholders 2GX13
55 Figure 7 – Ball-pressure apparatus
Figure 8 – Bracket for fixing lampholders for the impact test
57 Figure 9 – Test cap and test assembly for testing of resistance to heatof lampholders G13, G5 and GX5 with T marking
59 Figure 10 – Dimensions of starterholder and holder
60 Figure 11 – “Go” plug gauges for starterholders
61 Figure 12 – Plug gauge for starterholders for testing contact making and retention
62 Figure 13 – Special plug gauge for starterholders for testing contact making
63 Figure 14 – Test cap for the test of Clause 14 for lampholders G5 and GX5
Figure 15 – Test cap for the test of Clause 14 for lampholders G13
64 Figure 16 – Test cap for the test of Clause 14 for lampholders 2G13
Figure 18 – Test cap for the test ofClause 14 for lampholders Fa6
Figure 17 – Test cap for the test ofClause 14 for lampholders G20
65 Figure 19 – Test cap for the test of Clause 14 for lampholders G10q, GU10q and GZ10q
Figure 20 – Test cap for the test of Clause 14 for lampholders Fa8
66 Figure 21 – Test starter for the test of Clause 14
67 Figure 22 – Test cap for the test of Clause 14 for lampholders R17d
68 Figure 23 – Test cap for the test of Clause 14 for lampholders 2G11
69 Figure 24 – Test cap for the test of Clause 14 for lampholders G23 and GX23
70 Figure 25 – Test cap for the test of Clause 14 for lampholders GR8
Figure 26 – Test cap for the test of Clause 14 for lampholders GR10q
71 Figure 27 – Test cap for the test of Clause 14 for lampholders GX10q and GY10q
72 Figure 28 – Test cap for the test of Clause 14 for lampholders G24, GX24 and GY24
73 Figure 29 – Test cap for the test of Clause 14 for lampholders G32 and GY32
74 Figure 30 – Test cap for the test of 18.1 for lampholders G23
75 Figure 31 – Test cap for the test of 18.1 for lampholders GR8
76 Figure 32 – Test cap for the test of 18.1 for lampholders GR10q
77 Figure 33 – Test cap for the test of 18.1 for lampholders GX10q
78 Figure 34 – Test cap for the test of 18.1 for lampholders GY10q
79 Figure 35 – Test cap for the test of 18.1 for lampholders 2G11
80 Figure 36 – Test cap for the test of 18.1 for lampholders GX23
81 Figure 37 – Test cap for the test of 18.1 for lampholders G24, GX24 and GY24 (1 of 2)
83 Figure 38 – Test cap for the test of 18.1 for lampholders G32, GX32 and GY32 (1 of 2)
85 Figure 39 – Test cap for the test of Clause 14 for lampholders 2G8
86 Figure 40 – Test cap for the test of Clause 14 for lampholders GX53
87 Figure 41 – Standard test finger (according to IEC 60529:2014)
88 Figure 42 – Test cap for the test of Clause 14 for lampholders W4.3×8.5d
89 Figure 43 – Test cap for the test of Clause 14 for lampholders GR14q
90 Figure 44 – Test cap for the test of Clause 14 for lampholders G28d
91 Figure 45 – Test cap for the test of Clause 14 for lampholders 2GX11
92 Figure 46 – Test probes for checking gasket sleeves on lampholders for higher IP protection
93 Annex A (normative) Examples of lampholders covered by IEC 60400
Table A.1 – Examples of lampholders covered by IEC 60400
94 Annex B (normative) Season cracking/corrosion test
B.1 General
B.2 Test cabinet
B.3 Test solution
Table B.1 – pH adjustment
95 B.4 Test procedure
96 Annex C (informative) Protection against electric shock – Explanatory details for the installation of lampholders according to 9.2
Figure C.1 – Examples of lampholders
97 Annex D (informative) Clauses containing new or more stringent requirements with respect to the previous edition
98 Bibliography
BS EN 60400:2017