Radiation protection instrumentation. Radon and radon decay product measuring instruments – Specific requirements for 222Rn and 220Rn measuring instruments

Published By Publication Date Number of Pages
BSI 2018 30
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61577 describes the specific requirements for instruments measuring the activity concentration of airborne 222Rn and 220Rn outdoors, in dwellings, and in workplaces including underground mines. This standard applies practically to all types of electronic measuring instruments that are based on either spot or continuous measurements. The activity concentration can be measured by pumping or by diffusing the air containing 222Rn and/or 220Rn into the sensitive volume of the detection unit or at a particular moment by taking an air sample (grab sampling).

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Table 1 — Reference conditions and standard test conditions (unless otherwise indicated by the manufacturer)
7 English
CONTENTS
9 FOREWORD
11 INTRODUCTION
12 1 Scope
2 Normative references
13 3 Terms and definitions
14 4 General design considerations
4.1 Design considerations for the measurements
4.1.1 General
15 4.1.2 Effects caused by physical properties of 222Rn and 220Rn
4.2 Design considerations for handling and maintenance
4.2.1 Portability
4.2.2 Application under harsh environmental conditions
16 4.2.3 Automatic operation
4.2.4 Reliability
4.2.5 Capability for operational testing
4.2.6 Adjustment and maintenance facilities
4.2.7 Acoustic noise level
4.2.8 Electromagnetic interference
17 4.2.9 Storage
5 Technical components
5.1 Sampling assembly
5.2 Radiation detection assembly
18 5.3 Data processing and recording
5.4 Measurement display
5.5 Power supply
19 6 Test conditions
6.1 General
6.2 Standard test conditions
6.3 Execution of tests
6.4 Reference atmospheres
20 7 Requirements and tests concerning radiation detection performance
7.1 Reference response to a test source
7.1.1 Requirements
7.1.2 Test method
7.2 Cross-interference to other radon isotopes
7.2.1 Requirements
7.2.2 Test method
7.3 Linearity of indication
7.3.1 Requirements
21 7.3.2 Test method
7.4 Instrument statistical fluctuation
7.4.1 Requirements
7.4.2 Test method
22 7.5 Response time
7.5.1 Requirements
7.5.2 Test method
7.6 Signal accumulation
7.6.1 Requirements
7.6.2 Test method
8 Requirements and tests concerning air circuit performance
8.1 General
23 8.2 Flow-rate stability
8.2.1 Requirements
8.2.2 Test method
8.3 Accuracy of the air flow-rate measurement
8.3.1 Requirements
8.3.2 Test method
8.4 Effect of filter pressure drop
8.4.1 Requirements
8.4.2 Test method
24 8.5 Indication of low sampling flow-rate
8.5.1 Requirements
8.5.2 Test method
9 Requirements and tests concerning environmental performance
9.1 Response to ambient gamma radiation
9.1.1 Requirements
9.1.2 Test method
9.2 Ambient temperature
9.2.1 Requirements
9.2.2 Test method
25 9.3 Relative humidity and condensed moisture
9.3.1 Requirements
9.3.2 Test method
9.4 Atmospheric pressure
10 Requirements and tests concerning electrical performance
10.1 Power supply variations
10.1.1 Requirements
10.1.2 Test method
26 10.2 Battery test
10.2.1 Requirements
10.2.2 Test method
11 Requirements and tests concerning mechanical performance
11.1 Requirements
11.2 Test method
12 Operation and maintenance manual
27 13 Type test report and certificate
28 Tables
Table 1 – Reference conditions and standard test conditions (unless otherwise indicated by the manufacturer)
Table 2 – Tests of the radiation detection performance
29 Table 3 – Tests of the air circuit performance
Table 4 – Tests performed with variation of influence quantities
BS EN 61577-2:2017