BS EN ISO 16315:2016:2022 Edition
$167.15
Small craft. Electric propulsion system
Published By | Publication Date | Number of Pages |
BSI | 2022 | 40 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
6 | European foreword Endorsement notice |
7 | Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of Directive 2013/53/EU Table ZA.1 — Correspondence between this European Standard and EU Directives |
11 | Foreword |
12 | Introduction |
13 | 1 Scope 2 Normative references |
14 | 3 Terms and definitions |
17 | 4 General requirements 4.1 General |
18 | 4.2 Components of an electric propulsion system 4.3 Electric propulsion systems |
20 | 4.4 Arrangements for other electrical equipment and circuits on-board a small craft connected to a common energy source for both propulsion and general electrical installation 4.4.1 DC systems 4.4.2 AC systems |
21 | 4.5 Environmental factors 4.6 Electrical ratings |
22 | 4.7 Equipment 4.7.1 Transformers 4.7.2 Converters 4.7.3 Motors 4.8 Enclosures 4.9 Identification of equipment and conductors |
23 | 4.10 Segregation of DC and AC systems 4.11 Steering and throttle controls 4.12 Electromagnetic compatibility (EMC) 4.13 Electrical equipment in the vicinity of battery banks 4.14 Hazardous areas |
24 | 5 Controls, monitoring, system alerts and trips alarms 5.1 Electrical/electronic controls for electric propulsion systems 5.1.1 Controls |
25 | 5.1.2 Emergency stop 5.1.3 Fault trip reset 5.1.4 “Get you home” mode 5.2 Instruments, alerts and trip alarms 5.2.1 General 5.2.2 Operating mode and status |
26 | 5.2.3 System alerts 5.2.4 Fault trip alarms 6 Protection against electric shock 6.1 Protection against direct contact 6.2 Automatic disconnection of supply to the electric propulsion system under fault-to-earth conditions (earthed two wire DC systems and earthed neutral AC systems) |
27 | 6.3 Fault-to-earth monitoring and tripping arrangements for DC fully insulated systems, DC 3-wire systems |
28 | 6.4 Fault-to-earth tripping in AC non-neutral earthed systems (IT-type system) 7 Protection against over-current 7.1 General 7.2 Characteristics of protective devices |
29 | 7.3 Overcurrent devices in the outgoing circuit(s) from a battery 8 Battery monitoring and installation 8.1 General arrangements |
30 | 8.2 Isolation of battery packs or battery banks 8.3 Operational switching of battery pack(s) or battery bank(s) 8.4 Permanently energized circuits |
31 | 8.5 Ventilation 8.6 Electrical apparatus for explosive gas atmospheres 9 Electrical installation 9.1 General |
32 | 9.2 Segregation of electrical propulsion system cables 10 Testing 10.1 General 10.2 Earthing and bonding 10.3 Insulation resistance 10.3.1 General 10.3.2 DC electrical propulsion systems |
33 | 10.3.3 AC electrical propulsion systems 10.3.4 Switchboards, panel boards and distribution boards 10.3.5 Power and lighting final circuits 10.3.6 Generators and motors 10.3.7 Transformers 10.4 Electrical/electronic controls systems for propulsion motor control 10.5 On load test and inspection of electrical propulsion systems, and associated switch gear and control gear |
34 | 10.6 Voltage drop |
35 | Annex A (normative) Information and instructions to be included in the owner’s manual |
36 | Annex B (normative) Installation documentation |
37 | Bibliography |