BS ISO 16413:2020

$167.15

Evaluation of thickness, density and interface width of thin films by X-ray reflectometry. Instrumental requirements, alignment and positioning, data collection, data analysis and reporting

Published By Publication Date Number of Pages
BSI 2020 42
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies a method for the evaluation of thickness, density and interface width of single layer and multi-layered thin films which have thicknesses between approximately 1 nm and 1 ?m, on flat substrates, by means of X-Ray Reflectometry (XRR).

This method uses a monochromatic, collimated beam, scanning either an angle or a scattering vector. Similar considerations apply to the case of a convergent beam with parallel data collection using a distributed detector or to scanning wavelength, but these methods are not described here. While mention is made of diffuse XRR, and the requirements for experiments are similar, this is not covered in the present document.

Measurements may be made on equipment of various configurations, from laboratory instruments to reflectometers at synchrotron radiation beamlines or automated systems used in industry.

Attention should be paid to an eventual instability of the layers over the duration of the data collection, which would cause a reduction in the accuracy of the measurement results. Since XRR, performed at a single wavelength, does not provide chemical information about the layers, attention should be paid to possible contamination or reactions at the specimen surface. The accuracy of results for the outmost layer is strongly influenced by any changes at the surface.

NOTE 1 Proprietary techniques are not described in this document.

PDF Catalog

PDF Pages PDF Title
2 undefined
6 Foreword
7 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
3.1 Terms and definitions
11 3.2 Symbols and abbreviated terms
12 4 Instrumental requirements, alignment and positioning guidelines
4.1 Instrumental requirements for the scanning method
4.1.1 Schematic diagrams
14 4.1.2 Incident beam — Requirements and recommendations
15 4.1.3 Specimen — Requirements and recommendations
16 4.1.4 Goniometer — Requirements
4.1.5 Detector — Requirements
17 4.2 Instrument alignment
4.3 Specimen alignment
19 5 Data collection and storage
5.1 Preliminary remarks
5.2 Data scan parameters
5.3 Dynamic range
20 5.4 Step size (peak definition)
5.4.1 Fixed intervals scan
5.4.2 Continuous scan
5.5 Collection time (accumulated counts)
5.6 Segmented data collection
21 5.7 Reduction of noise
5.8 Detectors
5.9 Environment
5.10 Data storage
5.10.1 Data output format
5.10.2 Headers
22 6 Data analysis
6.1 Preliminary data treatment
6.2 Specimen modelling
6.2.1 General
23 6.2.2 Interface width models
24 6.3 Simulation of XRR data
6.4 General examples
30 6.5 Data fitting
32 7 Information required when reporting XRR analysis
7.1 General
7.2 Experimental details
33 7.3 Analysis (simulation and fitting) procedures
34 7.4 Methods for reporting XRR curves
7.4.1 Independent and dependent variables
7.4.2 Graphical plotting of XRR data
37 Annex A (informative) Example of report for an oxynitrided silicon wafer
40 Bibliography