Shopping Cart

No products in the cart.

BSI PD IEC/TR 61282-11:2012

$167.15

Fibre optic communication system design guides – Multimode launch conditions

Published By Publication Date Number of Pages
BSI 2012 40
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC/TR 61282-11:2012(E) is intended to show the background of encircled flux for the characterisation of multimode launch conditions. This includes the selection of the encircled flux and the definition of the encircled flux requirements in conjunction with the implied variation in attenuation measurements.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
6 FOREWORD
8 INTRODUCTION
9 1 Scope
2 Normative references
3 Terms and definitions
10 4 Background
5 Metrics for multimode launch conditions
5.1 General
11 5.2 Coupled power ratio (CPR)
5.3 Mode power distribution / relative power distribution (MPD/RPD)
12 5.4 Encircled flux (EF)
6 Uncertainties
6.1 General
6.2 Measurement model and uncertainties
13 6.3 Uncertainty due to the setup
6.4 Uncertainty due to the power meter
6.5 Random uncertainties
6.5.1 Uncertainty due to fibre manipulation
14 6.5.2 Uncertainties due to launch conditions
15 6.6 Example of uncertainty accumulation
Figures
Figure 1 – Uncertainties due to the launch conditions for a given loss
Tables
Table 1 – Uncertainties accumulation
16 7 Encircled flux envelope – theory and assumptions
7.1 Mode field eigenfunctions
18 7.2 Connections, attenuation and the encircled flux template
19 7.3 Target weights
20 Figure 2 – Comparison of target weights
21 Figure 3 – Incremental loss using OFL launch
22 7.4 Coupling matrix calculations
Figure 4 – Incremental loss using target launch
23 8 Wavelength bias correction to EF targets/limits with spectrally broad sources
8.1 General
8.2 Modified spectrum assumptions
24 8.3 Determining the EF targets
Table 2 – Percent variation for best fit against target to derive adjustmentfor encircled flux for 50 µm MMF
25 8.4 Determining the EF limits
Table 3 – Encircled flux adjustment at 850 nm for 50 µm multimode fibre
Table 4 – Encircled flux adjustment at 1 300 nm for 50 µm multimode fibre
26 8.5 Validating the EF limits
Table 5 – Calculated encircled flux limits for 50 µm multimodefibre at 850 nm and 1 300 nm
28 Annex A (informative) IEC international standards related to multimode launch conditions
Table A.1 – Standards for multimode launch condition
30 Annex B (informative) Coupled power ratio measurement for fibre-optic sources
Table B.1 – Light source characteristics
31 Table B.2 – Light source categorization by CPR value (850 nm wavelength, CPR values in decibels)
Table B.3 – Light source categorization by CPR value (1 300 nm wavelength, CPR values in decibels)
32 Annex C (informative) Limits on RPD and MPD
33 Figure C.1 – Example of a characteristic MTF
35 Figure C.2 – Relative power distribution (RPD) specification
Figure C.3 – Example of a characteristic MPD
36 Figure C.4 – MPD (Modal power distribution) specification
37 Bibliography
BSI PD IEC/TR 61282-11:2012
$167.15