Shopping Cart

No products in the cart.

BSI PD IEC/TS 61967-3:2014

$167.15

Integrated circuits. Measurement of electromagnetic emissions – Measurement of radiated emissions. Surface scan method

Published By Publication Date Number of Pages
BSI 2014 38
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61967 provides a test procedure which defines an evaluation method for the near electric, magnetic or electromagnetic field components at or near the surface of an integrated circuit (IC). This diagnostic procedure is intended for IC architectural analysis such as floor planning and power distribution optimization. This test procedure is applicable to measurements on an IC mounted on any circuit board that is accessible to the scanning probe. In some cases it is useful to scan not only the IC but also its environment. For comparison of surface scan emissions between different ICs, the standardized test board defined in IEC 61967-1 should be used.

This measurement method provides a mapping of the electric or magnetic near-field emissions over the IC. The resolution of the measurement is determined by the capability of the measurement probe and the precision of the probe-positioning system. This method is intended for use up to 6 GHz. Extending the upper limit of frequency is possible with existing probe technology but is beyond the scope of this specification. Measurements may be carried out in the frequency domain or in the time domain.

PDF Catalog

PDF Pages PDF Title
4 English

CONTENTS
7 FOREWORD
9 INTRODUCTION
10 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
11 3.2 Abbreviations
4 General
12 5 Test conditions
5.1 General
5.2 Supply voltage
5.3 Frequency range
6 Test equipment
6.1 General
6.2 Shielding
6.3 RF measuring instrument
6.4 Preamplifier
13 6.5 Cables
6.6 Near-field probe
6.6.1 General
6.6.2 Magnetic (H) field probe
6.6.3 Electric (E) field probe
6.6.4 Combined electric and magnetic (E/H) field probe
6.6.5 Probe-positioning and data acquisition system
14 7 Test setup
7.1 General
7.2 Test configuration
Figures

Figure 1 – Example of probe-positioning system
15 Figure 2 – One-input RF measurement setup
Figure 3 – Two-input RF measurement setup with reference probe
Figure 4 – Two-input RF measurement setup with reference signal
16 7.3 Test circuit board
7.4 Probe-positioning system software setup
7.5 DUT software
8 Test procedure
8.1 General
8.2 Ambient conditions
8.3 Operational check
17 8.4 Test technique
18 9 Test report
9.1 General
9.2 Measurement conditions
9.3 Probe design and calibration
9.4 Measurement data
Figure 5 – Examples of data overlaid on an image of the DUT (Contour chart)
19 9.5 Post-processing
9.6 Data exchange
20 Annex A (normative) Calibration of near-field probes
A.1 General
21 Tables

Table A.1 – Probe factor linear units
Table A.2 – Probe factor logarithmic units
22 A.2 Test equipment
A.2.1 General
A.2.2 PCB with microstrip line
Figure A.1 – Typical probe factor against frequency
23 A.3 Calibration setup
Figure A.2 – Microstrip line for calibration (transverse cross-section)
Figure A.3 – Microstrip line for calibration (longitudinal cross-section)
Table A.3 – Dimensions for 50  microstrip
24 A.4 Calibration procedure
Figure A.4 – Probe calibration setup
Figure A.5 – Scan direction across Microstrip line
26 Figure A.6 – Typical plot of measured signal level and simulated field strength (HX)
Figure A.7 – Typical plot of measured signal level and simulated field strength (Hz)
27 Annex B (informative) Discrete electric and magnetic field probes
B.1 General
B.2 Probe electrical description
Figure B.1 – Electric and magnetic field probe schematics
28 B.3 Probe physical description
B.3.1 General
B.3.2 Electric field probe
B.3.3 Magnetic field probe
Figure B.2 – Example of electric field probe construction (EZ)
29 Figure B.3 – Example of magnetic field probe construction (HX or HY)
30 Annex C (informative) Combined electric and magnetic field probe example
C.1 General
C.2 Probe electrical description
Figure C 1 – Electromagnetic field probe schematic
31 C.3 Probe physical description
C.4 Measurement and data acquisition system
Figure C.2 – Electromagnetic field probe construction
32 Figure C.3 – Measurement and data acquisition system overview
Figure C.4 – Measurement and data acquisition system detail
33 Annex D (informative) Coordinate systems
D.1 General
D.2 Cartesian coordinate system
Figure D.1 – Right-hand Cartesian coordinate system (preferred)
34 D.3 Cylindrical coordinate system
Figure D.2 – Left-hand Cartesian coordinate system
Figure D.3 – Cylindrical coordinate system
35 D.4 Spherical coordinate system
D.5 Coordinate system conversion
Figure D.4 – Spherical coordinate system
Table D.1 – Coordinate system conversion
36 Bibliography
BSI PD IEC/TS 61967-3:2014
$167.15