Shopping Cart

No products in the cart.

IEEE 400.2-2013

$79.63

IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) (Superseded Redline)

Published By Publication Date Number of Pages
IEEE 2013 60
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Revision Standard – Inactive-Reserved. Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 400.2-2013 Front Cover
3 Title page
6 Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata
Patents
8 Participants
9 Acknowledgements
10 Introduction
11 Contents
12 Important Notice
1. Overview
13 1.1 Scope
1.2 Purpose
2. Normative references
14 3. Definitions, acronyms, and abbreviations
3.1 Definitions
16 4. Safety
4.1 Safety practices
17 4.2 Grounding
18 5. Very low frequency (VLF) ac testing
21 5.1 General VLF ac withstand voltage testing
23 5.2 VLF ac withstand voltage testing with cosine-rectangular/bipolar pulse waveform
25 5.3 VLF ac withstand voltage testing with sinusoidal waveform
26 5.4 Tangent delta/differential tangent delta/tangent delta stability/leakage current/ harmonic loss current tests with VLF sinusoidal waveform
35 5.5 Partial discharge (PD) test with VLF sinusoidal waveform
36 5.6 Dielectric spectroscopy with VLF sinusoidal waveform
38 6. Conclusions
40 Annex A (informative) Bibliography
43 Annex B (normative) Wave shapes of VLF ac voltage testing voltages
44 Annex C (informative) Typical defects in fluid-filled and extruded cable systems
45 Annex D (informative) Effect of initial increase in voltage (ramp up)
47 Annex E (informative) Figures of merit and range of available tangent delta and differential tangent delta (tip up) data
49 Annex F (informative) Comments on data interpretation and performance
51 Annex G (informative) Tan delta results of new cable systems
54 Annex H (informative) Development of utility/application specific criteria
59 Annex I (informative) Tangent delta criteria used outside North America
IEEE 400.2-2013
$79.63