{"id":135942,"date":"2024-10-19T07:50:19","date_gmt":"2024-10-19T07:50:19","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/mn-buildingconservationcode-2000\/"},"modified":"2024-10-25T00:00:32","modified_gmt":"2024-10-25T00:00:32","slug":"mn-buildingconservationcode-2000","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/mn\/mn-buildingconservationcode-2000\/","title":{"rendered":"MN BuildingConservationCode 2000"},"content":{"rendered":"
Minnesota State Building Conservation Code is based on the Guidelines for Rehabilitation of Existing Buildings.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | COVER <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | MINNESOTA RULES, CHAPTER 1300 1300.0010 – ADMINISTRATION 1300.0020 – TITLE 1300.0030 – PURPOSE AND APPLICATION 1300.0040 – SCOPE 1300.0050 – CHAPTERS OF MINNESOTA STATE BUILDING CODE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 1300.0060 – OPTIONAL ADMINISTRATION 1300.0070 – DEFINITIONS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1300.0080 – CODE ADOPTION AND AMENDMENTS 1300.0090 – DEPARTMENT OF BUILDING SAFETY 1300.0110 – DUTIES AND POWERS OF BUILDING OFFICIAL <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1300.0120 – PERMITS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1300.0130 – CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1300.0140 – VIOLATIONS 1300.0150 – VIOLATIONS, PENALTY 1300.0160 – FEES <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1300.0170 – STOP WORK ORDER <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1300.0180 – UNSAFE BUILDINGS OR STRUCTURES 1300.0190 – TEMPORARY STRUCTURES AND USES 1300.0210 – INSPECTIONS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1300.0220 – CERTIFICATE OF OCCUPANCY 1300.0230 – BOARD OF APPEALS <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1300.0240 – DISCLAINER CLAUSE 1300.0250 – SEVERABILITY <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | MINNESOTA RULES, CHAPTER 1303 1303.1000 – TITLE 1303.1100 – PURPOSE 1303.1200 – RESTROOM FACILITIES IN PUBLIC ACCOMODATIONS 1303.1300 – SPACE FOR COMMUTER VANS 1303.1400 – AUTOMATIC GARAGE DOOR OPENING SYSTEMS 1303.1500 – RECYCLING SPACE Subp. 5. TABLE 1-A MINIMUM RECYCLING SPACE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 1303.1600 – FOOTING DEPTH FOR FROST PROTECTION 1303.1700 – GROUND SNOW LOAD 1303.1800 – RADIAL ICE ON TOWERS 1303.1900 – CONVENTIONAL FOUNDATION CONSTRUCTION TABLE 2-A – FOUNDATION WALL REINFORCEMENT REQUIREMENTS OF 12-INCH THICK HOLLOW UNIT MASONRY OR 8-INCH THICK CAST-IN-PLACE (CIP) CONCRETE. <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | TABLE 2-B – TYPES OF SOILS AND THEIR PROPERTIES 1303.2000 – EXTERIOR WOOD DECKS, PATIOS, AND BALCONIES 1303.2100 – BLEACHER SAFETY <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | MINNESOTA RULES, CHAPTER 1311 1311.0010 – ADOPTION BY REFERENCE OF THE GUIDELINES FOR THE REHABILITATION OF EXISTING BUILDINGS <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | CHAPTER 1 – TITLE AND SCOPE SECTION 101 – TITLE SECTION 102 – PURPOSE SECTION 103 – SCOPE SECTION 104 – NONCONFORMING RIGHTS SECTION 105 – ADDITIONS, ALTERATIONS AND REPAIRS SECTION 106 – CHANGE OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | SECTION 107 – MAINTENANCE SECTION 108 – ALTERNATE MATERIALS, ALTERNATE DESIGN AND METHODS OF CONSTRUCTION SECTION 109 – MODIFICATIONS SECTION 110 – TESTS <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | CHAPTER 2 – ENFORCEMENT AND PERMITS SECTION 201 – ADMINISTRATION SECTION 202 – PERMITS REQUIRED SECTION 203 – INSPECTION OF WORK SECTION 204 – RIGHT OF ENTRY SECTION 205 – LIABILITY SECTION 206 – UNSAFE BUILDINGS OR STRUCTURES <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | CHAPTER 3 – DEFINITIONS SECTION 301 – DEFINITIONS <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | CHAPTER 4 – ALTERATIONS AND REPAIRS TO EXISTING BUILDINGS SECTION 401 – GENERAL SECTION 402 – HEIGHTS AND AREAS SECTION 403 – LIFE SAFETY <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | SECTION 404 – INTERIOR FINISH SECTION 405 – SHAFT ENCLOSURES <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | SECTION 406 – FIRE SEPARATION AND SMOKE BARRIERS <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | SECTION 407 – FIRE-SUPPRESSION SYSTEMS <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | SECTION 408 – FIRE ALARMS <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | SECTION 409 – HIGH-RISE BUILDINGS SECTION 410 – BOILER\/FURNACE EQUIPMENT ROOMS SECTION 411 – STRUCTURAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | SECTION 412 – WEATHER PROTECTION SECTION 413 – OTHER SAFETY FEATURES <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | CHAPTER 5 – MINIMUM PROVISIONS FOR CHANGE OF OCCUPANCY SECTION 501 – GENERAL <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | SECTION 502 – FIRE- AND LIFE-SAFETY SECTION 503 – ENCLOSURE OF VERTICAL SHAFTS <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | SECTION 504 – EXTERIOR WALL FIRE-RESISTANCE RATINGS SECTION 505 – STRUCTURAL SAFETY SECTION 506 – HANDRAILS AND GUARDS SECTION 507 – HEALTH AND HYGIENE SECTION 508 – ENERGY CONSERVATION SECTION 509 – PLUMBING REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | SECTION 510 – MECHANICAL REQUIREMENTS SECTION 511 – ELECTRICAL REQUIREMENTS TABLE 5-A – HAZARD CATEGORIES AND CLASSIFICATIONS: HEIGHTS AND AREAS TABLE 5-B – HAZARD CATEGORIES AND CLASSIFICATIONS: LIFE SAFETY AND EXITS <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | TABLE 5-C – HAZARD CATEGORIES AND CLASSIFICATIONS: OCCUPANCY SEPARATIONS TABLE 5-D – HAZARD CATEGORIES AND CLASSIFICATIONS: EXPOSURE OF EXTERIOR WALLS <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | CHAPTER 6 – HISTORIC STRUCTURES SECTION 601 – PURPOSE SECTION 602 – REPAIRS SECTION 603 – FIRE-SAFETY <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | SECTION 604 – CHANGE OF OCCUPANCY <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | SECTION 605 – STRUCTURAL SAFETY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Minnesota State Building Conservation Code<\/b><\/p>\n |