{"id":15986,"date":"2024-10-16T22:00:59","date_gmt":"2024-10-16T22:00:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/irc-commentary-09-2009\/"},"modified":"2024-10-24T12:16:50","modified_gmt":"2024-10-24T12:16:50","slug":"irc-commentary-09-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/irc-commentary-09-2009\/","title":{"rendered":"IRC Commentary 09 2009"},"content":{"rendered":"

 A practical tool that helps you to master the code you deal with every day!<\/p>\n

\n This bundle includes both volume 1 and volume 2 of the 2009 International Residential Code\u00ae Commentary.\n<\/div>\n
\n  \n<\/div>\n
\n This comprehensive publication provides a convenient reference for regulations of the 2009 International Residential Code\u00ae (IRC\u00ae). Presented in an easy-to-reference format the commentary includes the full text of the code, including tables and figures, followed by corresponding commentary at the end of each section in one document. Every chapter begins with “General Comments” and “Purpose” sections followed by code and commentary to subsequent sections, tables and figures.\n<\/div>\n
\n  \n<\/div>\n
\n This in-depth publication focuses on providing the full meaning and implications of the 2009 IRC\u00ae. The commentaries are designed to suggest the most effective method of application, and the consequences of not adhering to the code.\n<\/div>\n
\n  \n<\/div>\n
\n This is an excellent reference for code officials, engineers, architects, inspectors, plans examiners, contractors and anyone who needs a better understanding of the 2009 IRC\u00ae.\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2009 IRC\u00ae INTERNATIONAL RESIDENTIAL CODE\u00ae FOR ONE- AND TWO-FAMILY DWELLINGS CODE AND COMMENTARY VOLUME 1 TITLE PAGE
2009 IRC\u00ae INTERNATIONAL RESIDENTIAL CODE\u00ae FOR ONE- AND TWO-FAMILY DWELLINGS CODE AND COMMENTARY VOLUME 1 TITLE PAGE <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT
COPYRIGHT <\/td>\n<\/tr>\n
3<\/td>\nPREFACE
PREFACE <\/td>\n<\/tr>\n
5<\/td>\nTABLE OF CONTENTS
TABLE OF CONTENTS <\/td>\n<\/tr>\n
7<\/td>\nPART I – ADMINISTRATIVE
\n
PART I – ADMINISTRATIVE
\n
CHAPTER 1: SCOPE AND ADMINISTRATION
CHAPTER 1: SCOPE AND ADMINISTRATION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
PART I\u2014SCOPE AND APPLICATION
PART I\u2014SCOPE AND APPLICATION
SECTION R101 – GENERAL
SECTION R101 – GENERAL <\/td>\n<\/tr>\n
9<\/td>\nSECTION R102 – APPLICABILITY
SECTION R102 – APPLICABILITY <\/td>\n<\/tr>\n
11<\/td>\nPART II\u2014ADMINISTRATION AND ENFORCEMENT
PART II\u2014ADMINISTRATION AND ENFORCEMENT
SECTION R103 – DEPARTMENT OF BUILDING SAFETY
SECTION R103 – DEPARTMENT OF BUILDING SAFETY
SECTION R104 – DUTIES AND POWERS OF THE BUILDING OFFICIAL
SECTION R104 – DUTIES AND POWERS OF THE BUILDING OFFICIAL <\/td>\n<\/tr>\n
12<\/td>\nFIGURE R104.5 – PERSONNEL IDENTIFICATION BADGE
FIGURE R104.5 – PERSONNEL IDENTIFICATION BADGE <\/td>\n<\/tr>\n
14<\/td>\nSECTION R105 – PERMITS
SECTION R105 – PERMITS <\/td>\n<\/tr>\n
18<\/td>\nSECTION R106 – CONSTRUCTION DOCUMENTS
SECTION R106 – CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
21<\/td>\nSECTION R107 – TEMPORARY STRUCTURES AND USES
SECTION R107 – TEMPORARY STRUCTURES AND USES
SECTION R108 – FEES
SECTION R108 – FEES <\/td>\n<\/tr>\n
22<\/td>\nSECTION R109 – INSPECTIONS
SECTION R109 – INSPECTIONS <\/td>\n<\/tr>\n
24<\/td>\nSECTION R110 – CERTIFICATE OF OCCUPANCY
SECTION R110 – CERTIFICATE OF OCCUPANCY <\/td>\n<\/tr>\n
25<\/td>\nSECTION R111 – SERVICE UTILITIES
SECTION R111 – SERVICE UTILITIES
FIGURE R110.3 – CERTIFICATE OF OCCUPANCY
FIGURE R110.3 – CERTIFICATE OF OCCUPANCY <\/td>\n<\/tr>\n
26<\/td>\nSECTION R112 – BOARD OF APPEALS
SECTION R112 – BOARD OF APPEALS <\/td>\n<\/tr>\n
28<\/td>\nSECTION R113 – VIOLATIONS
SECTION R113 – VIOLATIONS
SECTION R114 – STOP WORK ORDER
SECTION R114 – STOP WORK ORDER <\/td>\n<\/tr>\n
29<\/td>\nFIGURE R114.1 – STOP WORK ORDER
FIGURE R114.1 – STOP WORK ORDER
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
31<\/td>\nPART II – DEFINITIONS
PART II – DEFINITIONS
CHAPTER 2: DEFINITIONS
CHAPTER 2: DEFINITIONS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R201 – GENERAL
SECTION R201 – GENERAL <\/td>\n<\/tr>\n
32<\/td>\nSECTION R202 – DEFINITIONS
SECTION R202 – DEFINITIONS
FIGURE R202(1) AIR ADMITTANCE VALVE OPENS TO ADMIT AIR TO RELIEVE NEGATIVE PRESSURE
FIGURE R202(1) AIR ADMITTANCE VALVE OPENS TO ADMIT AIR TO RELIEVE NEGATIVE PRESSURE <\/td>\n<\/tr>\n
33<\/td>\nFIGURE R202(2) AIR ADMITTANCE VALVE CLOSES AND SEALS VENT UNDER ZERO OR POSITIVE PRESSURE
FIGURE R202(2) AIR ADMITTANCE VALVE CLOSES AND SEALS VENT UNDER ZERO OR POSITIVE PRESSURE <\/td>\n<\/tr>\n
34<\/td>\nFIGURE R202(3) AIR GAP, AIR BREAK
FIGURE R202(3) AIR GAP, AIR BREAK <\/td>\n<\/tr>\n
38<\/td>\nFIGURE R202(4) BRANCH VENT
FIGURE R202(4) BRANCH VENT <\/td>\n<\/tr>\n
39<\/td>\nFIGURE R202(5) DRAINAGE SYSTEM COMPONENTS
FIGURE R202(5) DRAINAGE SYSTEM COMPONENTS <\/td>\n<\/tr>\n
42<\/td>\nFIGURE R202(6) ELECTRIC HYDRONIC CONVECTOR
FIGURE R202(6) ELECTRIC HYDRONIC CONVECTOR <\/td>\n<\/tr>\n
46<\/td>\nFIGURE R202(7) FULL OPENING EXHAUST HOOD
FIGURE R202(7) FULL OPENING EXHAUST HOOD <\/td>\n<\/tr>\n
48<\/td>\nFIGURE R202(8) FIRE-SEPARATION DISTANCE
FIGURE R202(8) FIRE-SEPARATION DISTANCE
FIGURE R202(9) FIXTURE AND HORIZONTAL BRANCH DRAIN
FIGURE R202(9) FIXTURE AND HORIZONTAL BRANCH DRAIN <\/td>\n<\/tr>\n
49<\/td>\nFIGURE R202(10) FIXTURE DRAIN
FIGURE R202(10) FIXTURE DRAIN <\/td>\n<\/tr>\n
53<\/td>\nFIGURE R202(11) HEIGHT OF BUILDING
FIGURE R202(11) HEIGHT OF BUILDING
FIGURE R202(12) STORY HEIGHT
FIGURE R202(12) STORY HEIGHT <\/td>\n<\/tr>\n
54<\/td>\nFIGURE R202(13) HIGH-TEMPERATURE CHIMNEY
FIGURE R202(13) HIGH-TEMPERATURE CHIMNEY <\/td>\n<\/tr>\n
64<\/td>\nFIGURE R202(14) RUNNING BOND MASONRY
FIGURE R202(14) RUNNING BOND MASONRY <\/td>\n<\/tr>\n
68<\/td>\nFIGURE R202.(15) THREE-STORY BUILDING
FIGURE R202.(15) THREE-STORY BUILDING <\/td>\n<\/tr>\n
69<\/td>\nFIGURE R202(16) SUMP PUMP
FIGURE R202(16) SUMP PUMP <\/td>\n<\/tr>\n
70<\/td>\nFIGURE R202(17) DEPTH OF WATER SEAL
FIGURE R202(17) DEPTH OF WATER SEAL <\/td>\n<\/tr>\n
74<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
75<\/td>\nPART III – BUILDING PLANNING AND CONSTRUCTION
PART III – BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3: BUILDING PLANNING
CHAPTER 3: BUILDING PLANNING
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE <\/td>\n<\/tr>\n
76<\/td>\nSECTION R301 – DESIGN CRITERIA
SECTION R301 – DESIGN CRITERIA <\/td>\n<\/tr>\n
78<\/td>\nTABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <\/td>\n<\/tr>\n
79<\/td>\nTABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B
TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B <\/td>\n<\/tr>\n
80<\/td>\nTABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) <\/td>\n<\/tr>\n
81<\/td>\nFIGURE R301.2(1) ISOLINES OF THE 971\/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES ( F)
FIGURE R301.2(1) ISOLINES OF THE 971\/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES ( F)
FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D
FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D <\/td>\n<\/tr>\n
82<\/td>\nFIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D
FIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D <\/td>\n<\/tr>\n
83<\/td>\nFIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D
FIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D <\/td>\n<\/tr>\n
84<\/td>\nFIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D
FIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D <\/td>\n<\/tr>\n
85<\/td>\nFIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D
FIGURE R301.2(2)\u2014continued SEISMIC DESIGN CATEGORIES\u2014SITE CLASS D <\/td>\n<\/tr>\n
86<\/td>\nFIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE
FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE <\/td>\n<\/tr>\n
87<\/td>\nFIGURE R301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
FIGURE R301.2(4) BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL <\/td>\n<\/tr>\n
88<\/td>\nFIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
FIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL <\/td>\n<\/tr>\n
89<\/td>\nFIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
FIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL <\/td>\n<\/tr>\n
90<\/td>\nFIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
FIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL <\/td>\n<\/tr>\n
91<\/td>\nFIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL
FIGURE R301.2(4)\u2014continued BASIC WIND SPEEDS FOR 50-YEAR MEAN RECURRENCE INTERVAL <\/td>\n<\/tr>\n
92<\/td>\nFIGURE R301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb\/ft2)
FIGURE R301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb\/ft2) <\/td>\n<\/tr>\n
93<\/td>\nFIGURE R301.2(5)\u2014continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb\/ft2)
FIGURE R301.2(5)\u2014continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb\/ft2) <\/td>\n<\/tr>\n
94<\/td>\nFIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP <\/td>\n<\/tr>\n
95<\/td>\nFIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
FIGURE R301.2(8) FROST LINE DEPTH
FIGURE R301.2(8) FROST LINE DEPTH <\/td>\n<\/tr>\n
96<\/td>\nFIGURE R301.2.1 WIND FORCES ACTING ON AREA
FIGURE R301.2.1 WIND FORCES ACTING ON AREA
TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d <\/td>\n<\/tr>\n
97<\/td>\nTABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa
TABLE R301.2.1.3 EQUIVALENT BASIC WIND SPEEDSa <\/td>\n<\/tr>\n
98<\/td>\nFIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT <\/td>\n<\/tr>\n
99<\/td>\nFIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
FIGURE R301.2.1.5.1(3) ILLUSTRATION OF UPWIND OBSTRUCTION
FIGURE R301.2.1.5.1(3) ILLUSTRATION OF UPWIND OBSTRUCTION <\/td>\n<\/tr>\n
100<\/td>\nTABLE R301.2.1.5.1 BASIC WIND MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
TABLE R301.2.1.5.1 BASIC WIND MODIFICATION FOR TOPOGRAPHIC WIND EFFECT <\/td>\n<\/tr>\n
101<\/td>\nFIGURE R301.2.2 SEISMIC FORCE
FIGURE R301.2.2 SEISMIC FORCE <\/td>\n<\/tr>\n
102<\/td>\nTABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION <\/td>\n<\/tr>\n
103<\/td>\nTABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa
TABLE R301.2.2.2.1 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa <\/td>\n<\/tr>\n
105<\/td>\nFIGURE R301.2.2.2.5(1) BRACED WALL PANELS OUT OF PLANE
FIGURE R301.2.2.2.5(1) BRACED WALL PANELS OUT OF PLANE
FIGURE R301.2.2.2.5(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE R301.2.2.2.5(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK <\/td>\n<\/tr>\n
106<\/td>\nFIGURE R301.2.2.2.5(3) FLOOR OR ROOF NOT SUPPORTED AT ALL EDGES
FIGURE R301.2.2.2.5(3) FLOOR OR ROOF NOT SUPPORTED AT ALL EDGES
FIGURE R301.2.2.2.5(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
FIGURE R301.2.2.2.5(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
FIGURE R301.2.2.2.5(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE R301.2.2.2.5(5) BRACED WALL PANEL EXTENSION OVER OPENING <\/td>\n<\/tr>\n
107<\/td>\nFIGURE R301.2.2.2.5(6) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE R301.2.2.2.5(6) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE R301.2.2.2.5(7) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE R301.2.2.2.5(7) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE R301.2.2.2.5(8) BRACED WALL LINES NOT PERPENDICULAR
FIGURE R301.2.2.2.5(8) BRACED WALL LINES NOT PERPENDICULAR <\/td>\n<\/tr>\n
110<\/td>\nTABLE R301.4 MINIMUM DESIGN DEAD LOADS FOR TYPICAL RESIDENTIAL COMPONENTS
TABLE R301.4 MINIMUM DESIGN DEAD LOADS FOR TYPICAL RESIDENTIAL COMPONENTS <\/td>\n<\/tr>\n
111<\/td>\nTABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) <\/td>\n<\/tr>\n
112<\/td>\nTABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa, b, c, d, e
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa, b, c, d, e
FIGURE R301.7 BEAM DEFLECTION
FIGURE R301.7 BEAM DEFLECTION <\/td>\n<\/tr>\n
113<\/td>\nSECTION R302 – FIRE-RESISTANT CONSTRUCTION
SECTION R302 – FIRE-RESISTANT CONSTRUCTION
TABLE R302.1 EXTERIOR WALLS
TABLE R302.1 EXTERIOR WALLS <\/td>\n<\/tr>\n
114<\/td>\nFIGURE R302.1(1) EXTERIOR WALLS AND PROJECTIONS
FIGURE R302.1(1) EXTERIOR WALLS AND PROJECTIONS <\/td>\n<\/tr>\n
115<\/td>\nFIGURE R302.1(2) EXTERIOR WALL FIRE-RESISTANCE-RATED REQUIREMENTS AND PROHIBITED OPENINGS
FIGURE R302.1(2) EXTERIOR WALL FIRE-RESISTANCE-RATED REQUIREMENTS AND PROHIBITED OPENINGS
FIGURE R302.1(3) EXTERIOR WALL FIRE-RESISTANCE-RATED REQUIREMENTS AND PROHIBITED OPENINGS
FIGURE R302.1(3) EXTERIOR WALL FIRE-RESISTANCE-RATED REQUIREMENTS AND PROHIBITED OPENINGS <\/td>\n<\/tr>\n
116<\/td>\nFIGURE R302.2 DWELLING UNIT SEPARATION FOR TOWNHOUSES
FIGURE R302.2 DWELLING UNIT SEPARATION FOR TOWNHOUSES <\/td>\n<\/tr>\n
118<\/td>\nFIGURE R302.2.2(1) PARAPET REQUIREMENTS FOR WALL BETWEEN TOWNHOUSES
FIGURE R302.2.2(1) PARAPET REQUIREMENTS FOR WALL BETWEEN TOWNHOUSES
FIGURE R302.2.2(2) EXCEPTION TO ELIMINATE PARAPET
FIGURE R302.2.2(2) EXCEPTION TO ELIMINATE PARAPET <\/td>\n<\/tr>\n
119<\/td>\nFIGURE R302.2.3 PARPET REQUIREMENTS
FIGURE R302.2.3 PARPET REQUIREMENTS <\/td>\n<\/tr>\n
120<\/td>\nFIGURE R302.3 DWELLING UNIT SEPARATIONS
FIGURE R302.3 DWELLING UNIT SEPARATIONS <\/td>\n<\/tr>\n
121<\/td>\nFIGURE R302.3.1 SUPPORT OF DWELLING UNIT SEPARATION
FIGURE R302.3.1 SUPPORT OF DWELLING UNIT SEPARATION <\/td>\n<\/tr>\n
122<\/td>\nFIGURE R302.4.1 TYPES OF PENETRATIONS
FIGURE R302.4.1 TYPES OF PENETRATIONS <\/td>\n<\/tr>\n
124<\/td>\nFIGURE R302.4.2(1) MEMBRANE PENETRATION BY OUTLET B
FIGURE R302.4.2(1) MEMBRANE PENETRATION BY OUTLET B <\/td>\n<\/tr>\n
125<\/td>\nFIGURE R302.4.2(2) EXCEPTION TO ANNULAR SPACE PROTECTION
FIGURE R302.4.2(2) EXCEPTION TO ANNULAR SPACE PROTECTION <\/td>\n<\/tr>\n
126<\/td>\nFIGURE R302.5.2 GARAGE\/DWELLING SEPARATION
FIGURE R302.5.2 GARAGE\/DWELLING SEPARATION <\/td>\n<\/tr>\n
127<\/td>\nTABLE R302.6 DWELLING\/GARAGE SEPARATION
TABLE R302.6 DWELLING\/GARAGE SEPARATION <\/td>\n<\/tr>\n
128<\/td>\nFIGURE R302.6 SEPARATION BETWEEN ATTACHED GARAGES AND DWELLING UNITS
FIGURE R302.6 SEPARATION BETWEEN ATTACHED GARAGES AND DWELLING UNITS <\/td>\n<\/tr>\n
130<\/td>\nFIGURE R302.9.4 INTERIOR FIRE TEST ROOM DIMENSIONS
FIGURE R302.9.4 INTERIOR FIRE TEST ROOM DIMENSIONS <\/td>\n<\/tr>\n
131<\/td>\nFIGURE R302.10.1 INSULATION FACING
FIGURE R302.10.1 INSULATION FACING <\/td>\n<\/tr>\n
132<\/td>\nFIGURE R302.11(1) FIRESTOPPING\u2014BALLOON FRAMING
FIGURE R302.11(1) FIRESTOPPING\u2014BALLOON FRAMING <\/td>\n<\/tr>\n
133<\/td>\nFIGURE R302.11(2) FIRESTOPPING\u2014PLATFORM FRAMING
FIGURE R302.11(2) FIRESTOPPING\u2014PLATFORM FRAMING
FIGURE R302.11(3) FIRESTOPPING\u2014FURRED SOFFIT
FIGURE R302.11(3) FIRESTOPPING\u2014FURRED SOFFIT <\/td>\n<\/tr>\n
134<\/td>\nFIGURE R302.11(4) FIRESTOPPING\u2014DROPPED CEILING
FIGURE R302.11(4) FIRESTOPPING\u2014DROPPED CEILING
FIGURE R302.11(5) FIRESTOPPING\u2014COVE CEILING
FIGURE R302.11(5) FIRESTOPPING\u2014COVE CEILING <\/td>\n<\/tr>\n
135<\/td>\nFIGURE R302.11(6) FIRESTOPPING\u2014AT TUB
FIGURE R302.11(6) FIRESTOPPING\u2014AT TUB
FIGURE R302.11(7) FIRESTOPPING\u2014AT STAIRWAYS
FIGURE R302.11(7) FIRESTOPPING\u2014AT STAIRWAYS <\/td>\n<\/tr>\n
136<\/td>\nFIGURE R302.11(8) FIRESTOPPING\u2014AROUND PIPING
FIGURE R302.11(8) FIRESTOPPING\u2014AROUND PIPING
FIGURE R302.11(9) FIRESTOPPING\u2014AROUND CHIMNEYS AND FIREPLACES
FIGURE R302.11(9) FIRESTOPPING\u2014AROUND CHIMNEYS AND FIREPLACES <\/td>\n<\/tr>\n
138<\/td>\nFIGURE 302.12(1) DRAFTSTOPPING OF CEILING SUSPENDED UNDER FLOOR FRAMING
FIGURE 302.12(1) DRAFTSTOPPING OF CEILING SUSPENDED UNDER FLOOR FRAMING
FIGURE 302.12(2) DRAFTSTOPPING OF TRUSS-TYPE FLOOR FRAMING
FIGURE 302.12(2) DRAFTSTOPPING OF TRUSS-TYPE FLOOR FRAMING <\/td>\n<\/tr>\n
139<\/td>\nSECTION R303 LIGHT, VENTILATION AND HEATING
SECTION R303 LIGHT, VENTILATION AND HEATING <\/td>\n<\/tr>\n
140<\/td>\nFIGURE R303.2 NATURAL LIGHT
FIGURE R303.2 NATURAL LIGHT <\/td>\n<\/tr>\n
141<\/td>\nFIGURE R303.4.1AIR INTAKE OPENING LOCATIONS
FIGURE R303.4.1AIR INTAKE OPENING LOCATIONS <\/td>\n<\/tr>\n
142<\/td>\nFIGURE R303.6 STAIRWAY ILLUMINATION
FIGURE R303.6 STAIRWAY ILLUMINATION <\/td>\n<\/tr>\n
143<\/td>\nSECTION R304 – MINIMUM ROOM AREAS
SECTION R304 – MINIMUM ROOM AREAS <\/td>\n<\/tr>\n
144<\/td>\nFIGURE R303.8 REQUIRED HEATING
FIGURE R303.8 REQUIRED HEATING
FIGURE R304.1 FLOOR AREA
FIGURE R304.1 FLOOR AREA <\/td>\n<\/tr>\n
145<\/td>\nFIGURE R304.4 HEIGHT EFFECT ON ROOM AREA
FIGURE R304.4 HEIGHT EFFECT ON ROOM AREA
SECTION R305 – CEILING HEIGHT
SECTION R305 – CEILING HEIGHT <\/td>\n<\/tr>\n
146<\/td>\nSECTION R306 – SANITATION
SECTION R306 – SANITATION
SECTION R307 – TOILET, BATH AND SHOWER SPACES
SECTION R307 – TOILET, BATH AND SHOWER SPACES
FIGURE R307.1 MINIMUM FIXTURE CLEARANCES
FIGURE R307.1 MINIMUM FIXTURE CLEARANCES <\/td>\n<\/tr>\n
147<\/td>\nSECTION R308 – GLAZING
SECTION R308 – GLAZING <\/td>\n<\/tr>\n
149<\/td>\nTABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 <\/td>\n<\/tr>\n
151<\/td>\nFIGURE R308.4(1) HAZARDOUS LOCATIONS
FIGURE R308.4(1) HAZARDOUS LOCATIONS <\/td>\n<\/tr>\n
152<\/td>\nFIGURE R308.4(2) PROTECTIVE BAR ALTERNATI
FIGURE R308.4(2) PROTECTIVE BAR ALTERNATI
FIGURE R308.4(3) GLASS IN SIDELIGHTS\u2014ELEVATION
FIGURE R308.4(3) GLASS IN SIDELIGHTS\u2014ELEVATION <\/td>\n<\/tr>\n
153<\/td>\nFIGURE R308.4(4) GLASS IN SIDELIGHTS\u2014PLAN
FIGURE R308.4(4) GLASS IN SIDELIGHTS\u2014PLAN
FIGURE R308.4(5) BARRIER BETWEEN GLAZING AND DOOR
FIGURE R308.4(5) BARRIER BETWEEN GLAZING AND DOOR <\/td>\n<\/tr>\n
154<\/td>\nFIGURE R308.4(6) GLASS IN SIDELIGHTS\u2014DWELLINGS
FIGURE R308.4(6) GLASS IN SIDELIGHTS\u2014DWELLINGS
FIGURE R308.4(7) GLAZING WITHIN A SHOWER ENCLOSURE
FIGURE R308.4(7) GLAZING WITHIN A SHOWER ENCLOSURE <\/td>\n<\/tr>\n
155<\/td>\nFIGURE R308.4(8) GLAZING ADJACENT TO SWIMMING POOL OR SPA
FIGURE R308.4(8) GLAZING ADJACENT TO SWIMMING POOL OR SPA
FIGURE R308.4(9) GLAZING ADJACENT TO STAIRWAYS
FIGURE R308.4(9) GLAZING ADJACENT TO STAIRWAYS <\/td>\n<\/tr>\n
157<\/td>\nSECTION R309 – GARAGES AND CARPORTS
SECTION R309 – GARAGES AND CARPORTS <\/td>\n<\/tr>\n
158<\/td>\nSECTION R310 – EMERGENCY ESCAPE AND RESCUE OPENINGS
SECTION R310 – EMERGENCY ESCAPE AND RESCUE OPENINGS <\/td>\n<\/tr>\n
159<\/td>\nFIGURE R310.1 EMERGENCY ESCAPE AND RESCUE WINDOW
FIGURE R310.1 EMERGENCY ESCAPE AND RESCUE WINDOW <\/td>\n<\/tr>\n
160<\/td>\nFIGURE R310.2 WINDOW WELLS
FIGURE R310.2 WINDOW WELLS <\/td>\n<\/tr>\n
161<\/td>\nSECTION R311 – MEANS OF EGRESS
SECTION R311 – MEANS OF EGRESS <\/td>\n<\/tr>\n
162<\/td>\nFIGURE R311.3.1 THRESHOLD HEIGHTS
FIGURE R311.3.1 THRESHOLD HEIGHTS <\/td>\n<\/tr>\n
164<\/td>\nFIGURE R311.7.1 STAIRWAY CLEARANCES
FIGURE R311.7.1 STAIRWAY CLEARANCES
FIGURE R311.7.2(1) MINIMUM HEADROOM
FIGURE R311.7.2(1) MINIMUM HEADROOM <\/td>\n<\/tr>\n
165<\/td>\nFIGURE R311.7.2(2) EXAMPLE OF EXCEPTION TO SECTION R311.7.2
FIGURE R311.7.2(2) EXAMPLE OF EXCEPTION TO SECTION R311.7.2 <\/td>\n<\/tr>\n
166<\/td>\nFIGURE R311.7.4.1(1) CONVENTIAL STAIRWAY
FIGURE R311.7.4.1(1) CONVENTIAL STAIRWAY <\/td>\n<\/tr>\n
167<\/td>\nFIGURE R311.7.4.1(2) STAIR TOLERANCES
FIGURE R311.7.4.1(2) STAIR TOLERANCES <\/td>\n<\/tr>\n
168<\/td>\nFIGURE R311.7.4.2(1) WINDERS
FIGURE R311.7.4.2(1) WINDERS
FIGURE R311.7.4.2(2) WINDERS USED FOR CIRCULAR STAIRWAY
FIGURE R311.7.4.2(2) WINDERS USED FOR CIRCULAR STAIRWAY <\/td>\n<\/tr>\n
169<\/td>\nFIGURE R311.7.4.3 TREAD PROFILE
FIGURE R311.7.4.3 TREAD PROFILE <\/td>\n<\/tr>\n
170<\/td>\nFIGURE R311.7.5 LANDINGS AT DOORS
FIGURE R311.7.5 LANDINGS AT DOORS <\/td>\n<\/tr>\n
171<\/td>\nFIGURE R311.7.7.2 HANDRAILS
FIGURE R311.7.7.2 HANDRAILS <\/td>\n<\/tr>\n
172<\/td>\nFIGURE R311.7.7.3(1) TYPE 1 HANDRAIL
FIGURE R311.7.7.3(1) TYPE 1 HANDRAIL
FIGURE R311.7.7.3(2) TYPE II HANDRAIL
FIGURE R311.7.7.3(2) TYPE II HANDRAIL <\/td>\n<\/tr>\n
173<\/td>\nFIGURE R311.7.9.1 SPIRAL STAIRS
FIGURE R311.7.9.1 SPIRAL STAIRS
FIGURE R311.7.9.2 BULKHEAD ENCLOSURE STAIRWAY
FIGURE R311.7.9.2 BULKHEAD ENCLOSURE STAIRWAY <\/td>\n<\/tr>\n
174<\/td>\nSECTION R312 – GUARDS
SECTION R312 – GUARDS <\/td>\n<\/tr>\n
175<\/td>\nFIGURE R312.1 DROP OFF AND GUARD HEIGHT REQUIREMENTS
FIGURE R312.1 DROP OFF AND GUARD HEIGHT REQUIREMENTS <\/td>\n<\/tr>\n
176<\/td>\nFIGURE R312.2(1) STAIRWAY GUARD
FIGURE R312.2(1) STAIRWAY GUARD
FIGURE R312.2(2) STAIRWAY GUARD
FIGURE R312.2(2) STAIRWAY GUARD <\/td>\n<\/tr>\n
177<\/td>\nSECTION R313 – AUTOMATIC FIRE SPRINKLER SYSTEMS
SECTION R313 – AUTOMATIC FIRE SPRINKLER SYSTEMS
FIGURE R312.3 GUARD REQUIREMENTS
FIGURE R312.3 GUARD REQUIREMENTS <\/td>\n<\/tr>\n
178<\/td>\nSECTION R314 – SMOKE ALARMS
SECTION R314 – SMOKE ALARMS <\/td>\n<\/tr>\n
179<\/td>\nFIGURE R314.3(1) LOCATION OF SMOKE ALARMS
FIGURE R314.3(1) LOCATION OF SMOKE ALARMS
FIGURE R314.3(2) SMOKE ALARM LOCATION
FIGURE R314.3(2) SMOKE ALARM LOCATION <\/td>\n<\/tr>\n
180<\/td>\nSECTION R315 – CARBON MONOXIDE ALARMS
SECTION R315 – CARBON MONOXIDE ALARMS <\/td>\n<\/tr>\n
181<\/td>\nFIGURE R315.1 LOCATION OF CARBON MONOXIDE ALARMS
FIGURE R315.1 LOCATION OF CARBON MONOXIDE ALARMS
SECTION R316 – FOAM PLASTIC
SECTION R316 – FOAM PLASTIC <\/td>\n<\/tr>\n
182<\/td>\nFIGURE R316.1 USE AND INSTALLATION REQUIREMENTS OF FOAM PLASTIC IN BUILDING CONSTRUCTION
FIGURE R316.1 USE AND INSTALLATION REQUIREMENTS OF FOAM PLASTIC IN BUILDING CONSTRUCTION <\/td>\n<\/tr>\n
184<\/td>\nFIGURE R316.5.1 ENCAPSULATED FOAM PLASTIC
FIGURE R316.5.1 ENCAPSULATED FOAM PLASTIC <\/td>\n<\/tr>\n
185<\/td>\nFIGURE R316.5.3 FOAM PLASTIC, ATTIC AND CRAWL SPACES
FIGURE R316.5.3 FOAM PLASTIC, ATTIC AND CRAWL SPACES <\/td>\n<\/tr>\n
188<\/td>\nFIGURE R316.5.11 FOAM PLASTIC SPRAY APPLIED TO SILL PLATE AND HEADER
FIGURE R316.5.11 FOAM PLASTIC SPRAY APPLIED TO SILL PLATE AND HEADER <\/td>\n<\/tr>\n
189<\/td>\nSECTION R317 – PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY
SECTION R317 – PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY
FIGURE R317.1(1) MINIMUM SEPARATION OF NONTREATED WOOD FROM GROUND
FIGURE R317.1(1) MINIMUM SEPARATION OF NONTREATED WOOD FROM GROUND <\/td>\n<\/tr>\n
190<\/td>\nFIGURE R317.1(2) WOOD SILLS ON FOUNDATION WALLS
FIGURE R317.1(2) WOOD SILLS ON FOUNDATION WALLS
FIGURE R317.1(3) WOOD SILLS AND SLEEPERS
FIGURE R317.1(3) WOOD SILLS AND SLEEPERS <\/td>\n<\/tr>\n
191<\/td>\nFIGURE R317.1(4) NONTREATED WOOD PROJECTING INTO A BEAM POCKET
FIGURE R317.1(4) NONTREATED WOOD PROJECTING INTO A BEAM POCKET
FIGURE R317.1(5) NONTREATED WOOD SIDING OR SHEATHING
FIGURE R317.1(5) NONTREATED WOOD SIDING OR SHEATHING <\/td>\n<\/tr>\n
192<\/td>\nFIGURE R317.1.2 WOOD POST EMBEDDED IN CONCRETE
FIGURE R317.1.2 WOOD POST EMBEDDED IN CONCRETE <\/td>\n<\/tr>\n
193<\/td>\nFIGURE R317.1.4 WOOD POST ON PERMEABLE PAD
FIGURE R317.1.4 WOOD POST ON PERMEABLE PAD <\/td>\n<\/tr>\n
194<\/td>\nFIGURE R317.2.1 TYPICAL LABEL FOR PRESSURE-TREATED WOOD
FIGURE R317.2.1 TYPICAL LABEL FOR PRESSURE-TREATED WOOD <\/td>\n<\/tr>\n
195<\/td>\nSECTION R318 – PROTECTION AGAINST SUBTERRANEAN TERMITES
SECTION R318 – PROTECTION AGAINST SUBTERRANEAN TERMITES <\/td>\n<\/tr>\n
196<\/td>\nSECTION R319 – SITE ADDRESS
SECTION R319 – SITE ADDRESS
SECTION R320 – ACCESSIBILITY
SECTION R320 – ACCESSIBILITY <\/td>\n<\/tr>\n
197<\/td>\nSECTION R321 – ELEVATORS AND PLATFORM LIFTS
SECTION R321 – ELEVATORS AND PLATFORM LIFTS <\/td>\n<\/tr>\n
198<\/td>\nSECTION R322 – FLOOD-RESISTANT CONSTRUCTION
SECTION R322 – FLOOD-RESISTANT CONSTRUCTION <\/td>\n<\/tr>\n
202<\/td>\nFIGURE R322.2 LIMITS OF MODERATE WAVE ACTION
FIGURE R322.2 LIMITS OF MODERATE WAVE ACTION <\/td>\n<\/tr>\n
206<\/td>\nSECTION R323 – STORM SHELTERS
SECTION R323 – STORM SHELTERS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
211<\/td>\nCHAPTER 4: FOUNDATIONS
CHAPTER 4: FOUNDATIONS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R401 – GENERAL
SECTION R401 – GENERAL <\/td>\n<\/tr>\n
212<\/td>\nFIGURE R401.3(1) LOT GRADING EXAMPLE
FIGURE R401.3(1) LOT GRADING EXAMPLE <\/td>\n<\/tr>\n
213<\/td>\nTABLE R401.4.1 – PRESUMPTIVE LOAD-BEARING VALUES OFFOUNDATION MATERIALSa
TABLE R401.4.1 – PRESUMPTIVE LOAD-BEARING VALUES OFFOUNDATION MATERIALSa
FIGURE R401.3(2) LOT GRADING EXAMPLE
FIGURE R401.3(2) LOT GRADING EXAMPLE <\/td>\n<\/tr>\n
214<\/td>\nSECTION R402 – MATERIALS
SECTION R402 – MATERIALS
FIGURE R402.1.2 EXAMPLE OF QUALITY MARK FOR PRESSURE-TREATED LUMBER
FIGURE R402.1.2 EXAMPLE OF QUALITY MARK FOR PRESSURE-TREATED LUMBER <\/td>\n<\/tr>\n
215<\/td>\nTABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE <\/td>\n<\/tr>\n
216<\/td>\nSECTION R403 FOOTINGS
SECTION R403 FOOTINGS
TABLE R403.1 MINIMUM WIDTH OF CONCRETE,PRECAST OR MASONRY FOOTINGS(inches)a
TABLE R403.1 MINIMUM WIDTH OF CONCRETE,PRECAST OR MASONRY FOOTINGS(inches)a <\/td>\n<\/tr>\n
217<\/td>\nFIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS
FIGURE R403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS <\/td>\n<\/tr>\n
218<\/td>\nFIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION <\/td>\n<\/tr>\n
219<\/td>\nFIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION <\/td>\n<\/tr>\n
220<\/td>\nFIGURE R403.1.3.2 DOWELS FOR SLABS-ON-GROUND WITH TURNED-DOWN FOOTINGS
FIGURE R403.1.3.2 DOWELS FOR SLABS-ON-GROUND WITH TURNED-DOWN FOOTINGS <\/td>\n<\/tr>\n
221<\/td>\nFIGURE R403.1.4 RECOMMENDATION FOR ADJACENT FOOTINGS AT DIFFERENT ELEVATIONS
FIGURE R403.1.4 RECOMMENDATION FOR ADJACENT FOOTINGS AT DIFFERENT ELEVATIONS <\/td>\n<\/tr>\n
222<\/td>\nFIGURE R403.1.5 RECOMMENDATION FOR STEPPED WALL FOOTINGS
FIGURE R403.1.5 RECOMMENDATION FOR STEPPED WALL FOOTINGS <\/td>\n<\/tr>\n
223<\/td>\nFIGURE R403.1.6 WOOD SILL PLATE ANCHORAGE TO FOUNDATIONS
FIGURE R403.1.6 WOOD SILL PLATE ANCHORAGE TO FOUNDATIONS <\/td>\n<\/tr>\n
224<\/td>\nFIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES <\/td>\n<\/tr>\n
225<\/td>\nFIGURE R403.1.7.2(1) BUILDINGS ADJACENT TO ASCENDING SLOPE EXCEEDING 1 TO 1
FIGURE R403.1.7.2(1) BUILDINGS ADJACENT TO ASCENDING SLOPE EXCEEDING 1 TO 1
FIGURE R403.1.7.2(2) BUILDINGS ADJACENT TO DESCENDING SLOPE EXCEEDING ONE TO ONE
FIGURE R403.1.7.2(2) BUILDINGS ADJACENT TO DESCENDING SLOPE EXCEEDING ONE TO ONE <\/td>\n<\/tr>\n
226<\/td>\nFIGURE R403.1.7.3 DETERMINATION OF FOUNDATION ELEVATION ON GRADED SITES
FIGURE R403.1.7.3 DETERMINATION OF FOUNDATION ELEVATION ON GRADED SITES <\/td>\n<\/tr>\n
227<\/td>\nTABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa <\/td>\n<\/tr>\n
228<\/td>\nFIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS <\/td>\n<\/tr>\n
230<\/td>\nFIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD <\/td>\n<\/tr>\n
231<\/td>\nTABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY <\/td>\n<\/tr>\n
232<\/td>\nTABLE R403.3(2)\u2014continuedAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
TABLE R403.3(2)\u2014continuedAIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY <\/td>\n<\/tr>\n
233<\/td>\nTABLE R403.3(2)\u2014continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
TABLE R403.3(2)\u2014continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY <\/td>\n<\/tr>\n
234<\/td>\nTABLE R403.3(2)\u2014continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
TABLE R403.3(2)\u2014continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY <\/td>\n<\/tr>\n
235<\/td>\nFIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTING ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTING ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE <\/td>\n<\/tr>\n
236<\/td>\nFIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches)
TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches) <\/td>\n<\/tr>\n
237<\/td>\nSECTION R404 – FOUNDATION AND RETAINING WALLS
SECTION R404 – FOUNDATION AND RETAINING WALLS
FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING <\/td>\n<\/tr>\n
238<\/td>\nFIGURE R404.1.1 FOUNDATION WALL WITH UNBALANCED FILL
FIGURE R404.1.1 FOUNDATION WALL WITH UNBALANCED FILL <\/td>\n<\/tr>\n
239<\/td>\nTABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS
TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS <\/td>\n<\/tr>\n
240<\/td>\nTABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa, c
TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHESa, c <\/td>\n<\/tr>\n
241<\/td>\nTABLE R404.1.1(3) 10-INCH FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa, c
TABLE R404.1.1(3) 10-INCH FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHESa, c <\/td>\n<\/tr>\n
242<\/td>\nTABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHESa, c
TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHESa, c <\/td>\n<\/tr>\n
244<\/td>\nTABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS b, c, d, e, g, h, i, j
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS b, c, d, e, g, h, i, j <\/td>\n<\/tr>\n
245<\/td>\nTABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i
TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i <\/td>\n<\/tr>\n
246<\/td>\nTABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i
TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i <\/td>\n<\/tr>\n
247<\/td>\nTABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, g, h, i
TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, g, h, i <\/td>\n<\/tr>\n
248<\/td>\nTABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, f, h, i, j
TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, f, h, i, j <\/td>\n<\/tr>\n
249<\/td>\nTABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLSb, c, d, e, g, h, i,
TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLSb, c, d, e, g, h, i, <\/td>\n<\/tr>\n
250<\/td>\nTABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLSb, c, d, e, f, h, i, k, n
TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLSb, c, d, e, f, h, i, k, n <\/td>\n<\/tr>\n
251<\/td>\nTABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c
TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c <\/td>\n<\/tr>\n
252<\/td>\nTABLE R404.1.2(9)\u2014continued MINIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c
TABLE R404.1.2(9)\u2014continued MINIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c <\/td>\n<\/tr>\n
258<\/td>\nFIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS <\/td>\n<\/tr>\n
259<\/td>\nFIGURE R404.1.7 BEARING FOUNDATION WALLS AGAINST LATERAL EARTH PRESSURE
FIGURE R404.1.7 BEARING FOUNDATION WALLS AGAINST LATERAL EARTH PRESSURE <\/td>\n<\/tr>\n
260<\/td>\nTABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure) <\/td>\n<\/tr>\n
261<\/td>\nSECTION R405 – FOUNDATION DRAINAGE
SECTION R405 – FOUNDATION DRAINAGE <\/td>\n<\/tr>\n
262<\/td>\nTABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM <\/td>\n<\/tr>\n
263<\/td>\nFIGURE R405.1(1) FOUNDATION DRAINAGE FOR HABITABLE SPACE BELOW GRADE
FIGURE R405.1(1) FOUNDATION DRAINAGE FOR HABITABLE SPACE BELOW GRADE <\/td>\n<\/tr>\n
264<\/td>\nFIGURE R405.1(2) OTHER SUGGESTED METHODS OF FOUNDATION DRAINAGE
FIGURE R405.1(2) OTHER SUGGESTED METHODS OF FOUNDATION DRAINAGE <\/td>\n<\/tr>\n
265<\/td>\nSECTION R406 – FOUNDATION WATERPROOFING AND DAMPPROOFING
SECTION R406 – FOUNDATION WATERPROOFING AND DAMPPROOFING
FIGURE R406.1(1) DAMPPROOFING OF MASONRY FOUNDATION WALL [SEE ALSO FIGURE R405.1(1)]
FIGURE R406.1(1) DAMPPROOFING OF MASONRY FOUNDATION WALL [SEE ALSO FIGURE R405.1(1)] <\/td>\n<\/tr>\n
266<\/td>\nFIGURE R406.1(2) DAMPPROOFING OF CONCRETE FOUNDATION WALL [SEE ALSO FIGURE R405.1(1)]
FIGURE R406.1(2) DAMPPROOFING OF CONCRETE FOUNDATION WALL [SEE ALSO FIGURE R405.1(1)] <\/td>\n<\/tr>\n
267<\/td>\nFIGURE R406.2 METHODS OF WATERPROOFING BASEMENT WALLS [SEE ALSO FIGURES R405.1(1) AND R405.1(2) FOR TYPICAL DRAINAGE DETAILS]
FIGURE R406.2 METHODS OF WATERPROOFING BASEMENT WALLS [SEE ALSO FIGURES R405.1(1) AND R405.1(2) FOR TYPICAL DRAINAGE DETAILS]
SECTION R407- COLUMNS
SECTION R407- COLUMNS <\/td>\n<\/tr>\n
268<\/td>\nFIGURE R407.3(1) COLUMN ANCHORAGE
FIGURE R407.3(1) COLUMN ANCHORAGE
FIGURE R407.3(2) COLUMN ANCHORAGE
FIGURE R407.3(2) COLUMN ANCHORAGE
FIGURE R407.3(3) COLUMN ANCHORAGE
FIGURE R407.3(3) COLUMN ANCHORAGE
SECTION R408 – UNDER-FLOOR SPACE
SECTION R408 – UNDER-FLOOR SPACE <\/td>\n<\/tr>\n
269<\/td>\nFIGURE R408.1 CRAWL-SPACE VENTILATION
FIGURE R408.1 CRAWL-SPACE VENTILATION <\/td>\n<\/tr>\n
271<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
273<\/td>\nCHAPTER 5: FLOORS
CHAPTER 5: FLOORS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R501 – GENERAL
SECTION R501 – GENERAL
SECTION R502 – WOOD FLOOR FRAMING
SECTION R502 – WOOD FLOOR FRAMING <\/td>\n<\/tr>\n
274<\/td>\nFIGURE R502.1 GRADE MAKE EXAMPLES
FIGURE R502.1 GRADE MAKE EXAMPLES
FIGURE R502.1.1 TREATED LUMBER GRADE MARK
FIGURE R502.1.1 TREATED LUMBER GRADE MARK <\/td>\n<\/tr>\n
276<\/td>\nFIGURE R502.2 FLOOR CONSTRUCTION
FIGURE R502.2 FLOOR CONSTRUCTION <\/td>\n<\/tr>\n
277<\/td>\nTABLE R502.2.2.1 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGERAND A 2-INCH NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOISTc, f, g
TABLE R502.2.2.1 FASTENER SPACING FOR A SOUTHERN PINE OR HEM-FIR DECK LEDGERAND A 2-INCH NOMINAL SOLID-SAWN SPRUCE-PINE-FIR BAND JOISTc, f, g <\/td>\n<\/tr>\n
278<\/td>\nFIGURE R502.2.2.3 DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R502.2.2.3 DECK ATTACHMENT FOR LATERAL LOADS <\/td>\n<\/tr>\n
280<\/td>\nTABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L\/\u00ce\u201d = 360)a
TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L\/\u00ce\u201d = 360)a <\/td>\n<\/tr>\n
281<\/td>\nTABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L\/\u00ce\u201d = 360)b
TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L\/\u00ce\u201d = 360)b <\/td>\n<\/tr>\n
282<\/td>\nTABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load 40 psf, Roof Live Load 20 psf)
TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load 40 psf, Roof Live Load 20 psf) <\/td>\n<\/tr>\n
283<\/td>\nTABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f <\/td>\n<\/tr>\n
284<\/td>\nFIGURE R502.4(1) DOUBLE JOIST UNDER BEARING PARTITION
FIGURE R502.4(1) DOUBLE JOIST UNDER BEARING PARTITION
FIGURE R502.4(2) SPACED JOISTS UNDER BEARING PARTITION WITH BLOCKING AT PENETRATION
FIGURE R502.4(2) SPACED JOISTS UNDER BEARING PARTITION WITH BLOCKING AT PENETRATION <\/td>\n<\/tr>\n
285<\/td>\nTABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R502.5(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs) <\/td>\n<\/tr>\n
286<\/td>\nTABLE R502.5(1)\u2014continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R502.5(1)\u2014continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
FIGURE R502.5(1) GIRDER SPAN-SPACING RELATIONSHIP
FIGURE R502.5(1) GIRDER SPAN-SPACING RELATIONSHIP <\/td>\n<\/tr>\n
287<\/td>\nTABLE R502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R502.5(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs) <\/td>\n<\/tr>\n
288<\/td>\nFIGURE R502.5(2) HEADER SPANS FOR EXTERIOR LOAD BEARING WALLS
FIGURE R502.5(2) HEADER SPANS FOR EXTERIOR LOAD BEARING WALLS
FIGURE R502.5(3) HEADERS SPANS FOR INTERIOR LOAD BEARING WALLS
FIGURE R502.5(3) HEADERS SPANS FOR INTERIOR LOAD BEARING WALLS <\/td>\n<\/tr>\n
289<\/td>\nFIGURE R502.6(1) FLOOR JOIST BEARING ON WOOD
FIGURE R502.6(1) FLOOR JOIST BEARING ON WOOD
FIGURE R502.6(2) FLOOR JOIST BEARING ON MASONRY
FIGURE R502.6(2) FLOOR JOIST BEARING ON MASONRY <\/td>\n<\/tr>\n
290<\/td>\nFIGURE R502.6(3) FLOOR JOIST BEARING ON RIBBON STRIP
FIGURE R502.6(3) FLOOR JOIST BEARING ON RIBBON STRIP
FIGURE R502.6(4) JOIST HANGER AT DOUBLE TOP PLATE
FIGURE R502.6(4) JOIST HANGER AT DOUBLE TOP PLATE
FIGURE R502.6.1 JOIST AT GIRDER
FIGURE R502.6.1 JOIST AT GIRDER <\/td>\n<\/tr>\n
291<\/td>\nFIGURE R502.6.2(1) JOIST HANGER AT GIRDER
FIGURE R502.6.2(1) JOIST HANGER AT GIRDER
FIGURE R502.6.2(2) LEDGER STRIPS AT BEAM OR GIRDER
FIGURE R502.6.2(2) LEDGER STRIPS AT BEAM OR GIRDER <\/td>\n<\/tr>\n
292<\/td>\nFIGURE R502.7 BLOCKING OF JOISTS
FIGURE R502.7 BLOCKING OF JOISTS
FIGURE R502.7.1 INTERMEDIATE LATERAL SUPPORT
FIGURE R502.7.1 INTERMEDIATE LATERAL SUPPORT <\/td>\n<\/tr>\n
294<\/td>\nFIGURE 502.8 CUTTING, NOTCHING AND DRILLING
FIGURE 502.8 CUTTING, NOTCHING AND DRILLING <\/td>\n<\/tr>\n
295<\/td>\nFIGURE R502.9 POSITIVE CONNECTION BETWEEN POSTS AND GIRDERS
FIGURE R502.9 POSITIVE CONNECTION BETWEEN POSTS AND GIRDERS
FIGURE R502.10(1) FLOOR FRAMING FOR MAXIMUM 4-FOOT OPENINGS
FIGURE R502.10(1) FLOOR FRAMING FOR MAXIMUM 4-FOOT OPENINGS <\/td>\n<\/tr>\n
296<\/td>\nFIGURE R502.10(2) FLOOR FRAMING FOR GREATER THAN 4-FOOT OPENINGS
FIGURE R502.10(2) FLOOR FRAMING FOR GREATER THAN 4-FOOT OPENINGS
FIGURE R502.10(3) HANGERS FOR JOIST-HEADER CONNECTION
FIGURE R502.10(3) HANGERS FOR JOIST-HEADER CONNECTION <\/td>\n<\/tr>\n
297<\/td>\nSECTION R503 – FLOOR SHEATHING
SECTION R503 – FLOOR SHEATHING <\/td>\n<\/tr>\n
298<\/td>\nTABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
FIGURE R503.1(1) FLOOR SHEATHING AS SUBFLOORING
FIGURE R503.1(1) FLOOR SHEATHING AS SUBFLOORING
FIGURE R503.1(2) SUBFLOOR (FLOOR SHEATHING) ORIENTATION
FIGURE R503.1(2) SUBFLOOR (FLOOR SHEATHING) ORIENTATION <\/td>\n<\/tr>\n
299<\/td>\nTABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c
TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c <\/td>\n<\/tr>\n
300<\/td>\nFIGURE R503.1.1 SUBFLOOR (FLOOR SHEATHING ORIENTATION)
FIGURE R503.1.1 SUBFLOOR (FLOOR SHEATHING ORIENTATION) <\/td>\n<\/tr>\n
301<\/td>\nTABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
FIGURE R503.2.1 PLYWOOD GRADE MARK EXAMPLES
FIGURE R503.2.1 PLYWOOD GRADE MARK EXAMPLES <\/td>\n<\/tr>\n
302<\/td>\nFIGURE R503.2.2(1 )IDENTIFICATION OF PLYWOOD SUBFLOOR SPAN LIMITATIONS
FIGURE R503.2.2(1 )IDENTIFICATION OF PLYWOOD SUBFLOOR SPAN LIMITATIONS
FIGURE R503.2.2(2) COMBINATION SUBFLOOR UNDERLAYMENT ALTERNATIVES
FIGURE R503.2.2(2) COMBINATION SUBFLOOR UNDERLAYMENT ALTERNATIVES <\/td>\n<\/tr>\n
303<\/td>\nFIGURE R503.3.1 PARTICLEBOARD GRADE MARK EXA
FIGURE R503.3.1 PARTICLEBOARD GRADE MARK EXA
SECTION R504 – PRESSURE PRESERVATIVELY TREATED-WOODFLOORS (ON GROUND)
SECTION R504 – PRESSURE PRESERVATIVELY TREATED-WOODFLOORS (ON GROUND) <\/td>\n<\/tr>\n
304<\/td>\nSECTION R505 – STEEL FLOOR FRAMING
SECTION R505 – STEEL FLOOR FRAMING <\/td>\n<\/tr>\n
305<\/td>\nFIGURE R505.1.1 STEEL FRAMING APPLICABILITY LIMITS
FIGURE R505.1.1 STEEL FRAMING APPLICABILITY LIMITS <\/td>\n<\/tr>\n
306<\/td>\nFIGURE R505.1.2 IN-LINE FRAMING
FIGURE R505.1.2 IN-LINE FRAMING
TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES
TABLE R505.2(1) COLD-FORMED STEEL JOIST SIZES <\/td>\n<\/tr>\n
307<\/td>\nFIGURE R505.2(1) C-SHAPED SECTION
FIGURE R505.2(1) C-SHAPED SECTION
FIGURE R505.2(2) TRACK SECTION
FIGURE R505.2(2) TRACK SECTION
TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
TABLE R505.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS <\/td>\n<\/tr>\n
308<\/td>\nTABLE R505.2.4 SCREW SUBSTITUTION FACTOR
TABLE R505.2.4 SCREW SUBSTITUTION FACTOR <\/td>\n<\/tr>\n
309<\/td>\nFIGURE R505.2.5.1 FLOOR JOIST WEB HOLES
FIGURE R505.2.5.1 FLOOR JOIST WEB HOLES <\/td>\n<\/tr>\n
310<\/td>\nFIGURE R505.2.5.3 WEB HOLE PATCH
FIGURE R505.2.5.3 WEB HOLE PATCH
TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS <\/td>\n<\/tr>\n
311<\/td>\nTABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION
FIGURE R505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION <\/td>\n<\/tr>\n
312<\/td>\nFIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION <\/td>\n<\/tr>\n
313<\/td>\nFIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION <\/td>\n<\/tr>\n
314<\/td>\nFIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL <\/td>\n<\/tr>\n
315<\/td>\nFIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS <\/td>\n<\/tr>\n
316<\/td>\nTABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014SINGLE SPANSa, b, c, d 33 ksi STEEL
TABLE R505.3.2(1) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014SINGLE SPANSa, b, c, d 33 ksi STEEL <\/td>\n<\/tr>\n
317<\/td>\nTABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014MULTIPLE SPANSa, b, c, d, e, f 33 ksi STEEL
TABLE R505.3.2(2) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014MULTIPLE SPANSa, b, c, d, e, f 33 ksi STEEL
FIGURE R505.3.2 SPAN ARRANGEMENT FOR FLOOR JOIST CONTINUOUS OVER SUPPORT
FIGURE R505.3.2 SPAN ARRANGEMENT FOR FLOOR JOIST CONTINUOUS OVER SUPPORT <\/td>\n<\/tr>\n
318<\/td>\nTABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014MULTIPLE SPANSa, b, c, d, e, f 50 ksi STEEL
TABLE R505.3.2(3) ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS\u2014MULTIPLE SPANSa, b, c, d, e, f 50 ksi STEEL <\/td>\n<\/tr>\n
319<\/td>\nFIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP <\/td>\n<\/tr>\n
320<\/td>\nFIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS <\/td>\n<\/tr>\n
321<\/td>\nFIGURE R505.3.4(2) BEARING STIFFENER
FIGURE R505.3.4(2) BEARING STIFFENER
TABLE R505.3.4(1) CLIP ANGLE BEARING STIFFENERS
TABLE R505.3.4(1) CLIP ANGLE BEARING STIFFENERS <\/td>\n<\/tr>\n
322<\/td>\nTABLE R505.3.4(2) CLIP ANGLE BEARING STIFFENERS
TABLE R505.3.4(2) CLIP ANGLE BEARING STIFFENERS
TABLE R505.3.4(3) CLIP ANGLE BEARING STIFFENERS
TABLE R505.3.4(3) CLIP ANGLE BEARING STIFFENERS <\/td>\n<\/tr>\n
323<\/td>\nTABLE R505.3.4(4) CLIP ANGLE BEARING STIFFENERS
TABLE R505.3.4(4) CLIP ANGLE BEARING STIFFENERS <\/td>\n<\/tr>\n
324<\/td>\nFIGURE R505.3.7 TRACK SPLICE
FIGURE R505.3.7 TRACK SPLICE
FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING
FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION: 6-FOOT FLOOR OPENING <\/td>\n<\/tr>\n
325<\/td>\nFIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION: 8-FOOT FLOOR OPENING
FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION: 8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) GOLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION\u20146-FOOT OPENING
FIGURE R505.3.8(3) GOLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION\u20146-FOOT OPENING <\/td>\n<\/tr>\n
326<\/td>\nFIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION\u20148-FOOT OPENING
FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION\u20148-FOOT OPENING
SECTION R506 – CONCRETE FLOORS (ON GROUND)
SECTION R506 – CONCRETE FLOORS (ON GROUND)
FIGURE R506.1 CONCRETE SLAB-ON-GROUND REQUIREMENTS
FIGURE R506.1 CONCRETE SLAB-ON-GROUND REQUIREMENTS <\/td>\n<\/tr>\n
327<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
329<\/td>\nCHAPTER 6: WALL CONSTRUCTION
CHAPTER 6: WALL CONSTRUCTION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R601 – GENERAL
SECTION R601 – GENERAL <\/td>\n<\/tr>\n
330<\/td>\nFIGURE R601.3 TYPICAL WOOD STUD WALL CONSTRUCTION
FIGURE R601.3 TYPICAL WOOD STUD WALL CONSTRUCTION <\/td>\n<\/tr>\n
331<\/td>\nTABLE R601.3.1 CLASS III VAPOR RETARDERS
TABLE R601.3.1 CLASS III VAPOR RETARDERS
SECTION R602 – WOOD WALL FRAMING
SECTION R602 – WOOD WALL FRAMING <\/td>\n<\/tr>\n
332<\/td>\nFIGURE R602.1 GRADE STAMP EXAMPLE FOR DIMENSIONAL LUMBER
FIGURE R602.1 GRADE STAMP EXAMPLE FOR DIMENSIONAL LUMBER
FIGURE R602.1.1 END-JOINTED LUMBER\u2014FINGER JOINT
FIGURE R602.1.1 END-JOINTED LUMBER\u2014FINGER JOINT <\/td>\n<\/tr>\n
334<\/td>\nTABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <\/td>\n<\/tr>\n
335<\/td>\nTABLE R602.3(1)\u2014continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
TABLE R602.3(1)\u2014continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <\/td>\n<\/tr>\n
336<\/td>\nTABLE R602.3(2) ALTERNATE ATTACHMENTS
TABLE R602.3(2) ALTERNATE ATTACHMENTS <\/td>\n<\/tr>\n
337<\/td>\nTABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES <\/td>\n<\/tr>\n
338<\/td>\nTABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS <\/td>\n<\/tr>\n
339<\/td>\nFIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING <\/td>\n<\/tr>\n
340<\/td>\nFIGURE R602.3(2) FRAMING DETAILS
FIGURE R602.3(2) FRAMING DETAILS <\/td>\n<\/tr>\n
341<\/td>\nTABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2b, c
TABLE R602.3.1 MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESS IN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2b, c <\/td>\n<\/tr>\n
342<\/td>\nTABLE R602.3.1\u2014continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESSIN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2
TABLE R602.3.1\u2014continued MAXIMUM ALLOWABLE LENGTH OF WOOD WALL STUDS EXPOSED TO WIND SPEEDS OF 100 mph OR LESSIN SEISMIC DESIGN CATEGORIES A, B, C, D0, D1 and D2 <\/td>\n<\/tr>\n
343<\/td>\nFIGURE R602.3.2 SINGLE TOP-PLATE SPLICE
FIGURE R602.3.2 SINGLE TOP-PLATE SPLICE <\/td>\n<\/tr>\n
344<\/td>\nFIGURE R602.3.3(1) TOP PLATE WITH 16-INCH STUD SPACING
FIGURE R602.3.3(1) TOP PLATE WITH 16-INCH STUD SPACING
FIGURE R602.3.3(2) TOP PLATE WITH 24-INCH STUD SPACING
FIGURE R602.3.3(2) TOP PLATE WITH 24-INCH STUD SPACING <\/td>\n<\/tr>\n
345<\/td>\nFIGURE R602.3.3(3) TOP PLATE WITH 24-INCH STUD SPACING AND BEARING POINT LIMITATIONS
FIGURE R602.3.3(3) TOP PLATE WITH 24-INCH STUD SPACING AND BEARING POINT LIMITATIONS
FIGURE R602.3.3(4) BLOCKED TOP PLATE WITH 24-INCH STUD S
FIGURE R602.3.3(4) BLOCKED TOP PLATE WITH 24-INCH STUD S <\/td>\n<\/tr>\n
346<\/td>\nFIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS <\/td>\n<\/tr>\n
347<\/td>\nFIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS <\/td>\n<\/tr>\n
348<\/td>\nFIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIP
FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIP
FIGURE R602.7 HEADER DETAIL
FIGURE R602.7 HEADER DETAIL <\/td>\n<\/tr>\n
349<\/td>\nTABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
TABLE R602.7.2 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
FIGURE R602.7.2 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION <\/td>\n<\/tr>\n
351<\/td>\nFIGURE R602.10 CRITICAL PARTS OF THE LATERAL LOAD PATH
FIGURE R602.10 CRITICAL PARTS OF THE LATERAL LOAD PATH <\/td>\n<\/tr>\n
352<\/td>\nFIGURE R602.10.1(1) WALL BRACING TERMINOLOGY
FIGURE R602.10.1(1) WALL BRACING TERMINOLOGY <\/td>\n<\/tr>\n
353<\/td>\nFIGURE R602.10.1(2) ACTUAL WALL LINE\/PROJECTION
FIGURE R602.10.1(2) ACTUAL WALL LINE\/PROJECTION
FIGURE R602.10.1(3) EFFECTIVE (IMAGINARY) BRACED WALL LINE
FIGURE R602.10.1(3) EFFECTIVE (IMAGINARY) BRACED WALL LINE <\/td>\n<\/tr>\n
356<\/td>\nFIGURE R602.10.1.2(1) WALL BRACING\u2014WIND LOADS
FIGURE R602.10.1.2(1) WALL BRACING\u2014WIND LOADS <\/td>\n<\/tr>\n
357<\/td>\nFIGURE R602.10.1.2(2) WALL BRACING\u2014SEISMIC LOADS
FIGURE R602.10.1.2(2) WALL BRACING\u2014SEISMIC LOADS
FIGURE R602.10.1.2(3) BASIS FOR WIND BRACING TABLE
FIGURE R602.10.1.2(3) BASIS FOR WIND BRACING TABLE <\/td>\n<\/tr>\n
358<\/td>\nFIGURE R602.10.1.2(4) EAVE-TO-RIDGE HEIGHT
FIGURE R602.10.1.2(4) EAVE-TO-RIDGE HEIGHT <\/td>\n<\/tr>\n
359<\/td>\nFIGURE R602.10.1.2(5) BRACED WALL LINE SPACING
FIGURE R602.10.1.2(5) BRACED WALL LINE SPACING <\/td>\n<\/tr>\n
360<\/td>\nTABLE R602.10.1.2(1)a, b, c, d, e BRACING REQUIREMENTS BASED ON WIND SPEED (AS A FUNCTION OF BRACED WALL LINE SPACING)
TABLE R602.10.1.2(1)a, b, c, d, e BRACING REQUIREMENTS BASED ON WIND SPEED (AS A FUNCTION OF BRACED WALL LINE SPACING) <\/td>\n<\/tr>\n
361<\/td>\nTABLE R602.10.1.2(1)a, b, c, d, e\u2014continued BRACING REQUIREMENTS BASED ON WIND SPEED
TABLE R602.10.1.2(1)a, b, c, d, e\u2014continued BRACING REQUIREMENTS BASED ON WIND SPEED <\/td>\n<\/tr>\n
362<\/td>\nTABLE R602.10.1.2(1)a, b, c, d, e\u2014continued BRACING REQUIREMENTS BASED ON WIND SPEED
TABLE R602.10.1.2(1)a, b, c, d, e\u2014continued BRACING REQUIREMENTS BASED ON WIND SPEED <\/td>\n<\/tr>\n
363<\/td>\nFIGURE R602.10.1.2(6) BASIS FOR SEISMIC BRACING TABLE
FIGURE R602.10.1.2(6) BASIS FOR SEISMIC BRACING TABLE <\/td>\n<\/tr>\n
364<\/td>\nTABLE R602.10.1.2(2)a, b, c BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY (AS A FUNCTION OF BRACED WALL LINE LENGTH)
TABLE R602.10.1.2(2)a, b, c BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY (AS A FUNCTION OF BRACED WALL LINE LENGTH) <\/td>\n<\/tr>\n
365<\/td>\nTABLE R602.10.1.2(2)a, b, c\u2014continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY(AS A FUNCTION OF BRACED WALL LINE LENGTH)
TABLE R602.10.1.2(2)a, b, c\u2014continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY(AS A FUNCTION OF BRACED WALL LINE LENGTH) <\/td>\n<\/tr>\n
366<\/td>\nTABLE R602.10.1.2(3) ADJUSTMENT FACTORS TO THE LENGTH OF REQUIRED SEISMIC WALL BRACING
TABLE R602.10.1.2(3) ADJUSTMENT FACTORS TO THE LENGTH OF REQUIRED SEISMIC WALL BRACING <\/td>\n<\/tr>\n
368<\/td>\nFIGURE R602.10.1.3 ANGLED CORNERS
FIGURE R602.10.1.3 ANGLED CORNERS <\/td>\n<\/tr>\n
369<\/td>\nFIGURE R602.10.1.3(1) INSUFFICIENT ROOM IN ANGLED PORTION OR WALL TO PERMIT BRACING
FIGURE R602.10.1.3(1) INSUFFICIENT ROOM IN ANGLED PORTION OR WALL TO PERMIT BRACING
FIGURE R602.10.1.3(2) ANGLED PORTION OF WALL GREATER THAN 8 FEET
FIGURE R602.10.1.3(2) ANGLED PORTION OF WALL GREATER THAN 8 FEET <\/td>\n<\/tr>\n
370<\/td>\nFIGURE R602.10.1.4(1) BRACED WALL PANELS AND BRACED WALL LINES
FIGURE R602.10.1.4(1) BRACED WALL PANELS AND BRACED WALL LINES <\/td>\n<\/tr>\n
371<\/td>\nFIGURE R602.10.1.4(2) BRACED WALL PANEL END DISTANCE REQUIREMENTS (SDC A, B AND C)
FIGURE R602.10.1.4(2) BRACED WALL PANEL END DISTANCE REQUIREMENTS (SDC A, B AND C)
FIGURE R602.10.1.4(3) OFFSETS PERMITTED FOR BRACED WALL LINES
FIGURE R602.10.1.4(3) OFFSETS PERMITTED FOR BRACED WALL LINES <\/td>\n<\/tr>\n
372<\/td>\nFIGURE R602.10.1.4(4) BRACED WALL LINE SPACING
FIGURE R602.10.1.4(4) BRACED WALL LINE SPACING
FIGURE R602.10.1.4(1) EFFECTIVE (IMAGINARY) BRACED WALL LINE
FIGURE R602.10.1.4(1) EFFECTIVE (IMAGINARY) BRACED WALL LINE <\/td>\n<\/tr>\n
373<\/td>\nFIGURE R602.10.1.4.1 BRACED WALL PANELS AT ENDS OF BRACED WALL LINES IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2
FIGURE R602.10.1.4.1 BRACED WALL PANELS AT ENDS OF BRACED WALL LINES IN SEISMIC DESIGN CATEGORIES D0, D1 AND D2
TABLE R602.10.1.5 ADJUSTMENTS OF BRACING LENGTH FOR BRACED WALL LINE SPACING GREATER THAN 25 FEET
TABLE R602.10.1.5 ADJUSTMENTS OF BRACING LENGTH FOR BRACED WALL LINE SPACING GREATER THAN 25 FEET <\/td>\n<\/tr>\n
375<\/td>\nTABLE R602.10.2 INTERMITTENT BRACING METHODS
TABLE R602.10.2 INTERMITTENT BRACING METHODS <\/td>\n<\/tr>\n
377<\/td>\nTABLE R602.10.3 EFFECTIVE LENGTHS FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH (BRACE METHODS DWB, WSP, SFB, PBS, PCP AND HPSa)
TABLE R602.10.3 EFFECTIVE LENGTHS FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH (BRACE METHODS DWB, WSP, SFB, PBS, PCP AND HPSa)
TABLE R602.10.3.1 MINIMUM LENGTH REQUIREMENTS FOR BRACED WALL PANELS
TABLE R602.10.3.1 MINIMUM LENGTH REQUIREMENTS FOR BRACED WALL PANELS <\/td>\n<\/tr>\n
378<\/td>\nTABLE R602.10.3.2 MINIMUM LENGTH REQUIREMENTS AND HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
TABLE R602.10.3.2 MINIMUM LENGTH REQUIREMENTS AND HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
FIGURE R602.10.3.2 ALTERNATE BRACED WALL PANEL
FIGURE R602.10.3.2 ALTERNATE BRACED WALL PANEL <\/td>\n<\/tr>\n
379<\/td>\nFIGURE R602.10.3.3 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS
FIGURE R602.10.3.3 METHOD PFH: PORTAL FRAME WITH HOLD-DOWNS <\/td>\n<\/tr>\n
380<\/td>\nFIGURE R602.10.3.4 METHOD PFG PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
FIGURE R602.10.3.4 METHOD PFG PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C <\/td>\n<\/tr>\n
381<\/td>\nTABLE R602.10.4.1 CONTINUOUS SHEATHING METHODS
TABLE R602.10.4.1 CONTINUOUS SHEATHING METHODS <\/td>\n<\/tr>\n
383<\/td>\nFIGURE R602.10.4.1.1 METHOD CS-PF: CONTINUOUS PORTAL FRAME PANEL CONSTRUCTION
FIGURE R602.10.4.1.1 METHOD CS-PF: CONTINUOUS PORTAL FRAME PANEL CONSTRUCTION <\/td>\n<\/tr>\n
384<\/td>\nTABLE R602.10.4.1.1 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO 6:1 ASPECT RATIO WALLSa,b
TABLE R602.10.4.1.1 TENSION STRAP CAPACITY REQUIRED FOR RESISTING WIND PRESSURES PERPENDICULAR TO 6:1 ASPECT RATIO WALLSa,b <\/td>\n<\/tr>\n
385<\/td>\nFIGURE R602.10.4.2 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
FIGURE R602.10.4.2 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.4.2 LENGTH REQUIREMENTS FOR BRACED WALL PANELS WITH CONTINUOUS SHEATHINGa (inches)
TABLE R602.10.4.2 LENGTH REQUIREMENTS FOR BRACED WALL PANELS WITH CONTINUOUS SHEATHINGa (inches) <\/td>\n<\/tr>\n
387<\/td>\nFIGURE R602.10.4.4(1) TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS SHEATHING
FIGURE R602.10.4.4(1) TYPICAL EXTERIOR CORNER FRAMING FOR CONTINUOUS SHEATHING <\/td>\n<\/tr>\n
388<\/td>\nFIGURE R602.10.4.4(2) BRACED WALL LINE WITH CONTINUOUS SHEATHING WITH CORNER RETURN PANEL
FIGURE R602.10.4.4(2) BRACED WALL LINE WITH CONTINUOUS SHEATHING WITH CORNER RETURN PANEL
FIGURE R602.10.4.4(3) BRACED WALL LINE WITH CONTINUOUS SHEATING WITHOUT CORNER RETURN PANEL
FIGURE R602.10.4.4(3) BRACED WALL LINE WITH CONTINUOUS SHEATING WITHOUT CORNER RETURN PANEL <\/td>\n<\/tr>\n
389<\/td>\nFIGURE R602.10.4.4(4) BRACED WALL LINE WITH CONTINUOUS SHEATHING FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITHOUT TIE DOWN
FIGURE R602.10.4.4(4) BRACED WALL LINE WITH CONTINUOUS SHEATHING FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITHOUT TIE DOWN
FIGURE R602.10.4.4(5) BRACED WALL LINE WITH CONTINUOUS SHEATHING\u2014FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITH HOLD-DOWN
FIGURE R602.10.4.4(5) BRACED WALL LINE WITH CONTINUOUS SHEATHING\u2014FIRST BRACED WALL PANEL AWAY FROM END OF WALL LINE WITH HOLD-DOWN <\/td>\n<\/tr>\n
390<\/td>\nTABLE R602.10.5.2 MINIMUM LENGTH REQUIREMENTS FOR STRUCTURAL FIBERBOARD BRACED WALL PANELS IN A CONTINUOUSLY-SHEATHED WALLa
TABLE R602.10.5.2 MINIMUM LENGTH REQUIREMENTS FOR STRUCTURAL FIBERBOARD BRACED WALL PANELS IN A CONTINUOUSLY-SHEATHED WALLa <\/td>\n<\/tr>\n
392<\/td>\nFIGURE R602.10.6(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR\/CEILING FRAMING
FIGURE R602.10.6(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR\/CEILING FRAMING
FIGURE R602.10.6(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR\/CEILING FRAMING
FIGURE R602.10.6(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR\/CEILING FRAMING <\/td>\n<\/tr>\n
393<\/td>\nFIGURE R602.10.6.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.6.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.6.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
FIGURE R602.10.6.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES <\/td>\n<\/tr>\n
394<\/td>\nFIGURE R602.10.6.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
FIGURE R602.10.6.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
TABLE R602.10.6.2 CONNECTION AND BLOCKING REQUIREMENTS BETWEEN BRACED WALL PANELS AND ROOF FRAMING
TABLE R602.10.6.2 CONNECTION AND BLOCKING REQUIREMENTS BETWEEN BRACED WALL PANELS AND ROOF FRAMING <\/td>\n<\/tr>\n
395<\/td>\nFIGURE R602.10.6.2 DISTANCE FROM TOP PLATE TO BOTTOM OF ROOF SHEATHING FOR PROVIDING CONNECTION REQUIREMENTS AND BLOCKING PER TABLE R602.10.6.2
FIGURE R602.10.6.2 DISTANCE FROM TOP PLATE TO BOTTOM OF ROOF SHEATHING FOR PROVIDING CONNECTION REQUIREMENTS AND BLOCKING PER TABLE R602.10.6.2 <\/td>\n<\/tr>\n
396<\/td>\nFIGURE R602.10.7 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
FIGURE R602.10.7 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS <\/td>\n<\/tr>\n
397<\/td>\nFIGURE R602.10.7.1(1) SEISMIC DESIGN CATEGORY D2 INTERIOR BRACED WALL SUPPORT
FIGURE R602.10.7.1(1) SEISMIC DESIGN CATEGORY D2 INTERIOR BRACED WALL SUPPORT <\/td>\n<\/tr>\n
398<\/td>\nFIGURE R602.10.7.1(2) SEISMIC DESIGN CATEGORY D2 INTERIOR BRACED WALL SUPPORT
FIGURE R602.10.7.1(2) SEISMIC DESIGN CATEGORY D2 INTERIOR BRACED WALL SUPPORT <\/td>\n<\/tr>\n
400<\/td>\nFIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION <\/td>\n<\/tr>\n
401<\/td>\nFIGURE R602.11.2(1) CRIPPLE WALL TOP PLATE EXTENDED 4 FEET OVER THE FOUNDATION
FIGURE R602.11.2(1) CRIPPLE WALL TOP PLATE EXTENDED 4 FEET OVER THE FOUNDATION <\/td>\n<\/tr>\n
402<\/td>\nTABLE R602.12(1) STONE OR MASONRY VENEER WALL BRACING REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B and C
TABLE R602.12(1) STONE OR MASONRY VENEER WALL BRACING REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B and C
TABLE R602.12(2) STONE OR MASONRY VENEER WALL BRACING REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 and D
TABLE R602.12(2) STONE OR MASONRY VENEER WALL BRACING REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 and D <\/td>\n<\/tr>\n
403<\/td>\nFIGURE R602.12 HOLD DOWNS AT EXTERIOR AND INTERIOR BRACED WALL PANELS
FIGURE R602.12 HOLD DOWNS AT EXTERIOR AND INTERIOR BRACED WALL PANELS <\/td>\n<\/tr>\n
404<\/td>\nSECTION R603 – STEEL WALL FRAMING
SECTION R603 – STEEL WALL FRAMING <\/td>\n<\/tr>\n
405<\/td>\nFIGURE R603.1.2 IN-LINE FRAMING
FIGURE R603.1.2 IN-LINE FRAMING <\/td>\n<\/tr>\n
406<\/td>\nTABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE R603.2(1) LOAD-BEARING COLD-FORMED STEEL STUD SIZES
TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
TABLE R603.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS <\/td>\n<\/tr>\n
407<\/td>\nFIGURE R603.2(1) C-SHAPED SECTION
FIGURE R603.2(1) C-SHAPED SECTION
FIGURE R603.2(2) TRACK SECTION
FIGURE R603.2(2) TRACK SECTION
TABLE R603.2.4 SCREW SUBSTITUTION FACTOR
TABLE R603.2.4 SCREW SUBSTITUTION FACTOR <\/td>\n<\/tr>\n
408<\/td>\nFIGURE R603.2.5.1 WEB HOLES
FIGURE R603.2.5.1 WEB HOLES <\/td>\n<\/tr>\n
409<\/td>\nFIGURE R603.2.5.3 STUD WEB HOLE PATCH
FIGURE R603.2.5.3 STUD WEB HOLE PATCH <\/td>\n<\/tr>\n
410<\/td>\nTABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b
TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa,b <\/td>\n<\/tr>\n
411<\/td>\nFIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION <\/td>\n<\/tr>\n
412<\/td>\nFIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTSa,b,c
TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTSa,b,c <\/td>\n<\/tr>\n
413<\/td>\nTABLE R603.3.1.1(2) GABLE END WALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTSa,b,c
TABLE R603.3.1.1(2) GABLE END WALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTSa,b,c
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa <\/td>\n<\/tr>\n
414<\/td>\nFIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL <\/td>\n<\/tr>\n
415<\/td>\nFIGURE R603.3.5 TRACK SPLICE
FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
FIGURE R603.4 CORNER FRAMING <\/td>\n<\/tr>\n
416<\/td>\nTABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 ksi STEEL
TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
417<\/td>\nTABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
TABLE R603.3.2(3) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
418<\/td>\nTABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
TABLE R603.3.2(4) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
419<\/td>\nTABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
TABLE R603.3.2(5) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
420<\/td>\nTABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
TABLE R603.3.2(6) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
421<\/td>\nTABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STE
TABLE R603.3.2(7) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STE <\/td>\n<\/tr>\n
422<\/td>\nTABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
TABLE R603.3.2(8) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
423<\/td>\nTABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
TABLE R603.3.2(9) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
424<\/td>\nTABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL
TABLE R603.3.2(10) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
425<\/td>\nTABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL
TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
426<\/td>\nTABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
427<\/td>\nTABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(13) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
428<\/td>\nTABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(14) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
429<\/td>\nTABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(15) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
430<\/td>\nTABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(16) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
431<\/td>\nTABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(17) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
432<\/td>\nTABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(18) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
433<\/td>\nTABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(19) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
434<\/td>\nTABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(20) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
435<\/td>\nTABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(21) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
436<\/td>\nTABLE R603.3.2(22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(22) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
437<\/td>\nTABLE R603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(23) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
438<\/td>\nTABLE R603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(24) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
439<\/td>\nTABLE R603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(25) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
440<\/td>\nTABLE R603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(26) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
441<\/td>\nTABLE R603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(27) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
442<\/td>\nTABLE R603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(28) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
443<\/td>\nTABLE R603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(29) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
444<\/td>\nTABLE R603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL
TABLE R603.3.2(30) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
445<\/td>\nTABLE R603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL
TABLE R603.3.2(31) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
446<\/td>\nTABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 33 ksi STEEL
TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
447<\/td>\nTABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 50 ksi STEEL
TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
448<\/td>\nTABLE R603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 33 ksi STEEL
TABLE R603.3.2.1(3) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 33 ksi STEEL <\/td>\n<\/tr>\n
449<\/td>\nTABLE R603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 50 ksi STEEL
TABLE R603.3.2.1(4) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa,b,c 50 ksi STEEL <\/td>\n<\/tr>\n
451<\/td>\nFIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(1) BOX BEAM HEADER
FIGURE 603.6(2) BACK-TO-BACK HEADER
FIGURE 603.6(2) BACK-TO-BACK HEADER <\/td>\n<\/tr>\n
452<\/td>\nFIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL <\/td>\n<\/tr>\n
453<\/td>\nTABLE R603.6(1) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
TABLE R603.6(1) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b <\/td>\n<\/tr>\n
454<\/td>\nTABLE R603.6(2) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
TABLE R603.6(2) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b <\/td>\n<\/tr>\n
455<\/td>\nTABLE R603.6(3) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
TABLE R603.6(3) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b <\/td>\n<\/tr>\n
456<\/td>\nTABLE R603.6(4) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
TABLE R603.6(4) BOX-BEAM HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b <\/td>\n<\/tr>\n
457<\/td>\nTABLE R603.6(5) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(5) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
458<\/td>\nTABLE R603.6(6) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(6) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
459<\/td>\nTABLE R603.6(7) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(7) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
460<\/td>\nTABLE R603.6(8) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a,
TABLE R603.6(8) BOX-BEAM HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, <\/td>\n<\/tr>\n
461<\/td>\nTABLE R603.6(9) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a
TABLE R603.6(9) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a <\/td>\n<\/tr>\n
462<\/td>\nTABLE R603.6(10) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(10) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
463<\/td>\nTABLE R603.6(11) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(11) BOX-BEAM HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
464<\/td>\nTABLE R603.6(12) BOX-BEAM HEADER SPANSa,b,cHeaders Supporting Two Floors, Roof and Ceiling (50 ksi steel)a,b
TABLE R603.6(12) BOX-BEAM HEADER SPANSa,b,cHeaders Supporting Two Floors, Roof and Ceiling (50 ksi steel)a,b <\/td>\n<\/tr>\n
465<\/td>\nTABLE R603.6(13) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a,b
TABLE R603.6(13) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a,b <\/td>\n<\/tr>\n
466<\/td>\nTABLE R603.6(14) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a,b
TABLE R603.6(14) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a,b <\/td>\n<\/tr>\n
467<\/td>\nTABLE R603.6(15) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b
TABLE R603.6(15) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (33 ksi steel)a, b <\/td>\n<\/tr>\n
468<\/td>\nTABLE R603.6(16) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b
TABLE R603.6(16) BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Only (50 ksi steel)a, b <\/td>\n<\/tr>\n
469<\/td>\nTABLE R603.6(17) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(17) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
470<\/td>\nTABLE R603.6(18) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(18) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
471<\/td>\nTABLE R603.6(19) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(19) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
472<\/td>\nTABLE R603.6(20) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(20) BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
473<\/td>\nTABLE R603.6(21) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b
TABLE R603.6(21) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
474<\/td>\nTABLE R603.6(22) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(22) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
475<\/td>\nTABLE R603.6(23) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and ceiling (33 ksi steel)a, b
TABLE R603.6(23) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and ceiling (33 ksi steel)a, b <\/td>\n<\/tr>\n
476<\/td>\nTABLE R603.6(24) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b
TABLE R603.6(24) BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceiling (50 ksi steel)a, b <\/td>\n<\/tr>\n
477<\/td>\nTABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d <\/td>\n<\/tr>\n
478<\/td>\nTABLE R603.8 HEAD AND SILL TRACK SPAN
TABLE R603.8 HEAD AND SILL TRACK SPAN
FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN <\/td>\n<\/tr>\n
479<\/td>\nFIGURE R603.9.2 CORNER STUD HOLD-DOWN DETAIL
FIGURE R603.9.2 CORNER STUD HOLD-DOWN DETAIL <\/td>\n<\/tr>\n
480<\/td>\nTABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b
TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa,b
TABLE R603.9.2(2)FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
TABLE R603.9.2(2)FULL HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS <\/td>\n<\/tr>\n
481<\/td>\nSECTION R604 – WOOD STRUCTURAL PANELS
SECTION R604 – WOOD STRUCTURAL PANELS
SECTION R605 – PARTICLEBOARD
SECTION R605 – PARTICLEBOARD <\/td>\n<\/tr>\n
482<\/td>\nSECTION R606 – GENERAL MASONRY CONSTRUCTION
SECTION R606 – GENERAL MASONRY CONSTRUCTION
FIGURE R606.2.1 MINIMUM THICKNESS\u2014MASONRY BEARING AND EXTERIOR WALLS FOR A ONE-STORY DWELLING
FIGURE R606.2.1 MINIMUM THICKNESS\u2014MASONRY BEARING AND EXTERIOR WALLS FOR A ONE-STORY DWELLING <\/td>\n<\/tr>\n
483<\/td>\nFIGURE R606.3(1) MASONRY CORBELING LIMITATIONS PER COURSE
FIGURE R606.3(1) MASONRY CORBELING LIMITATIONS PER COURSE <\/td>\n<\/tr>\n
484<\/td>\nFIGURE R606.3(2) MASONRY CORBELING LIMITATIONS PER COURSE
FIGURE R606.3(2) MASONRY CORBELING LIMITATIONS PER COURSE
FIGURE R606.4(2) MASONRY CORBELING LIMITATIONS PER COURSE
FIGURE R606.4(2) MASONRY CORBELING LIMITATIONS PER COURSE <\/td>\n<\/tr>\n
485<\/td>\nTABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOREMPIRICAL DESIGN OF MASONRY
TABLE R606.5 ALLOWABLE COMPRESSIVE STRESSES FOREMPIRICAL DESIGN OF MASONRY <\/td>\n<\/tr>\n
486<\/td>\nFIGURE R606.8(1) MINIMUM HORIZONTAL JOINT REINFORCEMENT FOR STACK-BOND MASONRY
FIGURE R606.8(1) MINIMUM HORIZONTAL JOINT REINFORCEMENT FOR STACK-BOND MASONRY <\/td>\n<\/tr>\n
487<\/td>\nFIGURE R606.8(2) HORIZONTAL JOINT REINFORCEMENT-LADDER AND TRUSS TYPES
FIGURE R606.8(2) HORIZONTAL JOINT REINFORCEMENT-LADDER AND TRUSS TYPES
TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
TABLE R606.9 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS <\/td>\n<\/tr>\n
488<\/td>\nFIGURE R606.9 BUILDING ELEMENTS PROVIDING LATERAL SUPPORT TO WALLS
FIGURE R606.9 BUILDING ELEMENTS PROVIDING LATERAL SUPPORT TO WALLS
FIGURE R606.9.1.2 INTERSECTING MASONRY WALLS
FIGURE R606.9.1.2 INTERSECTING MASONRY WALLS <\/td>\n<\/tr>\n
489<\/td>\nFIGURE R606.9.2.1(1) ANCHORAGE OF ROOF STRUCTURES
FIGURE R606.9.2.1(1) ANCHORAGE OF ROOF STRUCTURES
FIGURE R606.9.2.1(2) ANCHORAGE OF ROOF STRUCTURES
FIGURE R606.9.2.1(2) ANCHORAGE OF ROOF STRUCTURES <\/td>\n<\/tr>\n
491<\/td>\nFIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF <\/td>\n<\/tr>\n
492<\/td>\nFIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C <\/td>\n<\/tr>\n
493<\/td>\nFIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D2
FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1, OR D2 <\/td>\n<\/tr>\n
494<\/td>\nTABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES <\/td>\n<\/tr>\n
495<\/td>\nTABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDING ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1 <\/td>\n<\/tr>\n
496<\/td>\nTABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS INSEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS INSEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2 <\/td>\n<\/tr>\n
497<\/td>\nFIGURE R606.13 REINFORCING STEEL CLEARANCES
FIGURE R606.13 REINFORCING STEEL CLEARANCES
FIGURE R606.14 BEAM OR GIRDER BEARING ON MASONRY
FIGURE R606.14 BEAM OR GIRDER BEARING ON MASONRY <\/td>\n<\/tr>\n
498<\/td>\nFIGURE R606.14.1 JOIST-BEARING MINIMUMS
FIGURE R606.14.1 JOIST-BEARING MINIMUMS
TABLE R606.15.1 MINIMUM CORROSION PROTECTION
TABLE R606.15.1 MINIMUM CORROSION PROTECTION <\/td>\n<\/tr>\n
499<\/td>\nSECTION R607 – UNIT MASONRY
SECTION R607 – UNIT MASONRY
TABLE R607.1 MORTAR PROPORTIONSa, b
TABLE R607.1 MORTAR PROPORTIONSa, b <\/td>\n<\/tr>\n
501<\/td>\nSECTION R608 – MULTIPLE WYTHE MASONRY
SECTION R608 – MULTIPLE WYTHE MASONRY
FIGURE R608.1.1.1 BONDING WITH SOLID UNIT MASONRY
FIGURE R608.1.1.1 BONDING WITH SOLID UNIT MASONRY
FIGURE R608.1.1.2 BONDING WITH HOLLOW UNIT MASONRY
FIGURE R608.1.1.2 BONDING WITH HOLLOW UNIT MASONRY <\/td>\n<\/tr>\n
502<\/td>\nFIGURE R608.1.2.1(1) MASONRY BONDING\u2014METAL TIES
FIGURE R608.1.2.1(1) MASONRY BONDING\u2014METAL TIES
FIGURE R608.1.2.1(2) BONDING AROUND OPENING IN MASONRY WALLS
FIGURE R608.1.2.1(2) BONDING AROUND OPENING IN MASONRY WALLS <\/td>\n<\/tr>\n
503<\/td>\nFIGURE R608.1.2.2 BONDING WITH ADJUSTABLE WALL TIES
FIGURE R608.1.2.2 BONDING WITH ADJUSTABLE WALL TIES <\/td>\n<\/tr>\n
504<\/td>\nFIGURE R608.1.2.3 BONDING WITH PREFABRICATED JOINT REINFORCEMENT
FIGURE R608.1.2.3 BONDING WITH PREFABRICATED JOINT REINFORCEMENT
SECTION R609 – GROUTED MASONRY
SECTION R609 – GROUTED MASONRY <\/td>\n<\/tr>\n
505<\/td>\nFIGURE R609.1 GROUTED MULTIPLE-WYTHE MASONRY
FIGURE R609.1 GROUTED MULTIPLE-WYTHE MASONRY
FIGURE R609.1.2 GROUTED MULTIPLE-WYTHE MASONRY
FIGURE R609.1.2 GROUTED MULTIPLE-WYTHE MASONRY <\/td>\n<\/tr>\n
506<\/td>\nTABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS <\/td>\n<\/tr>\n
507<\/td>\nFIGURE R609.3.1 REINFORCEMENT PLACEMENT LIMITATIONS
FIGURE R609.3.1 REINFORCEMENT PLACEMENT LIMITATIONS <\/td>\n<\/tr>\n
508<\/td>\nFIGURE R609.4.1(1) REINFORCEMENT PLACEMENT LIMITATIONS
FIGURE R609.4.1(1) REINFORCEMENT PLACEMENT LIMITATIONS
FIGURE R609.4.1(2) REINFORCED HOLLOW UNIT MASONRY VERTICAL CELL ALIGNMENT
FIGURE R609.4.1(2) REINFORCED HOLLOW UNIT MASONRY VERTICAL CELL ALIGNMENT <\/td>\n<\/tr>\n
509<\/td>\nFIGURE R609.4.1(3) MASONRY REINFORCING STEEL ALIGNMENT
FIGURE R609.4.1(3) MASONRY REINFORCING STEEL ALIGNMENT
FIGURE R609.4.1(4) REINFORCED HOLLOW UNIT MASONRY CLEANOUTS
FIGURE R609.4.1(4) REINFORCED HOLLOW UNIT MASONRY CLEANOUTS <\/td>\n<\/tr>\n
510<\/td>\nFIGURE R609.4.1(5) MASONRY REINFORCING STEEL ALIGNMENT
FIGURE R609.4.1(5) MASONRY REINFORCING STEEL ALIGNMENT
SECTION R610 – GLASS UNIT MASONRY
SECTION R610 – GLASS UNIT MASONRY <\/td>\n<\/tr>\n
511<\/td>\nFIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE <\/td>\n<\/tr>\n
512<\/td>\nFIGURE R610.5.2.1 GLASS UNIT MASONRY
FIGURE R610.5.2.1 GLASS UNIT MASONRY <\/td>\n<\/tr>\n
513<\/td>\nSECTION R611 – EXTERIOR CONCRETEWALL CONSTRUCTION
SECTION R611 – EXTERIOR CONCRETEWALL CONSTRUCTION <\/td>\n<\/tr>\n
514<\/td>\nFIGURE R611.2 ICF APPLICABILITY LIMITS
FIGURE R611.2 ICF APPLICABILITY LIMITS <\/td>\n<\/tr>\n
515<\/td>\nTABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLSa,b
TABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLSa,b <\/td>\n<\/tr>\n
516<\/td>\nFIGURE R611.3(1) FLAT WALL SYSTEM
FIGURE R611.3(1) FLAT WALL SYSTEM
FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM
FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM <\/td>\n<\/tr>\n
519<\/td>\nTABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
TABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R611.5.4(1) LAP SPLICES
FIGURE R611.5.4(1) LAP SPLICES <\/td>\n<\/tr>\n
520<\/td>\nFIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE R611.5.4(3) STANDARD HOOKS
FIGURE R611.5.4(3) STANDARD HOOKS <\/td>\n<\/tr>\n
522<\/td>\nTABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c
TABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATE BAR SIZE AND\/OR ALTERNATE GRADE OF STEELa, b, c <\/td>\n<\/tr>\n
523<\/td>\nFIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY
FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY <\/td>\n<\/tr>\n
524<\/td>\nFIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON GROUND FOOTING
FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON GROUND FOOTING <\/td>\n<\/tr>\n
525<\/td>\nTABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e
TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e <\/td>\n<\/tr>\n
526<\/td>\nTABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLSa, b, c, d, e
TABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLSa, b, c, d, e <\/td>\n<\/tr>\n
527<\/td>\nTABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e
TABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e <\/td>\n<\/tr>\n
528<\/td>\nTABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
TABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l <\/td>\n<\/tr>\n
529<\/td>\nTABLE R611.6(4)\u2014continued MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
TABLE R611.6(4)\u2014continued MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l <\/td>\n<\/tr>\n
530<\/td>\nEQUATION R611-1
EQUATION R611-1 <\/td>\n<\/tr>\n
531<\/td>\nEQUATION R611-2
EQUATION R611-2 <\/td>\n<\/tr>\n
532<\/td>\nTABLE R611.7.1.1 VELOCITY PRESSURES
TABLE R611.7.1.1 VELOCITY PRESSURES <\/td>\n<\/tr>\n
533<\/td>\nTABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g
TABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g <\/td>\n<\/tr>\n
534<\/td>\nTABLE R611.7(1A)\u2014continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g
TABLE R611.7(1A)\u2014continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORYa,c,d,e,f,g <\/td>\n<\/tr>\n
535<\/td>\nTABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g
TABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g <\/td>\n<\/tr>\n
536<\/td>\nTABLE R611.7(1B)\u2014continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g
TABLE R611.7(1B)\u2014continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g <\/td>\n<\/tr>\n
537<\/td>\nTABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa,c,d,e,f,g
TABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa,c,d,e,f,g <\/td>\n<\/tr>\n
538<\/td>\nTABLE R611.7(1C)\u2014continuedUNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g
TABLE R611.7(1C)\u2014continuedUNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORYa,c,d,e,f,g <\/td>\n<\/tr>\n
539<\/td>\nFIGURE R611.7(1) MINIMUM SOLID WALL LENGTH
FIGURE R611.7(1) MINIMUM SOLID WALL LENGTH <\/td>\n<\/tr>\n
540<\/td>\nFIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
FIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL <\/td>\n<\/tr>\n
541<\/td>\nTABLE R611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS <\/td>\n<\/tr>\n
542<\/td>\nTABLE R611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa,b
TABLE R611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa,b <\/td>\n<\/tr>\n
543<\/td>\nTABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa,c
TABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa,c <\/td>\n<\/tr>\n
545<\/td>\nFIGURE R611.8(1) REINFORCEMENT OF OPENINGS
FIGURE R611.8(1) REINFORCEMENT OF OPENINGS <\/td>\n<\/tr>\n
546<\/td>\nFIGURE R611.8(2) LINTEL FOR FLAT WALLS
FIGURE R611.8(2) LINTEL FOR FLAT WALLS
FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS
FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS <\/td>\n<\/tr>\n
547<\/td>\nFIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS
FIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS <\/td>\n<\/tr>\n
548<\/td>\nTABLE R611.8.2 APPLICABLE REQUIREMENTS FOR LINTELS
TABLE R611.8.2 APPLICABLE REQUIREMENTS FOR LINTELS <\/td>\n<\/tr>\n
550<\/td>\nTABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONSa, b, d
TABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONSa, b, d <\/td>\n<\/tr>\n
551<\/td>\nTABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
552<\/td>\nTABLE R611.8(2)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(2)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
553<\/td>\nTABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
554<\/td>\nTABLE R611.8(3)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(3)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
555<\/td>\nTABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
556<\/td>\nTABLE R611.8(4)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(4)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
557<\/td>\nTABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
558<\/td>\nTABLE R611.8(5)\u2014continuedMAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(5)\u2014continuedMAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
559<\/td>\nTABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
TABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET <\/td>\n<\/tr>\n
560<\/td>\nTABLE R611.8(6)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
TABLE R611.8(6)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET <\/td>\n<\/tr>\n
561<\/td>\nTABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
562<\/td>\nTABLE R611.8(7)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(7)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
563<\/td>\nTABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET <\/td>\n<\/tr>\n
564<\/td>\nTABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
TABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h <\/td>\n<\/tr>\n
565<\/td>\nTABLE R611.8(9)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, hROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(9)\u2014continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, hROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g
TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g <\/td>\n<\/tr>\n
567<\/td>\nFIGURE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
FIGURE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
568<\/td>\nTABLE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c
TABLE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c <\/td>\n<\/tr>\n
569<\/td>\nFIGURE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL
FIGURE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL <\/td>\n<\/tr>\n
570<\/td>\nTABLE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b
TABLE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b <\/td>\n<\/tr>\n
571<\/td>\nFIGURE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
FIGURE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
572<\/td>\nTABLE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
TABLE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e <\/td>\n<\/tr>\n
573<\/td>\nFIGURE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL
FIGURE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL <\/td>\n<\/tr>\n
574<\/td>\nTABLE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
TABLE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e <\/td>\n<\/tr>\n
575<\/td>\nFIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
FIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
576<\/td>\nTABLE R611.9(5) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d
TABLE R611.9(5) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d <\/td>\n<\/tr>\n
577<\/td>\nFIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
FIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL <\/td>\n<\/tr>\n
578<\/td>\nTABLE R611.9(6) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b, c, d
TABLE R611.9(6) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b, c, d <\/td>\n<\/tr>\n
579<\/td>\nFIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR
FIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
580<\/td>\nTABLE R611.9(7) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
TABLE R611.9(7) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e <\/td>\n<\/tr>\n
581<\/td>\nFIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
FIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL <\/td>\n<\/tr>\n
582<\/td>\nTABLE R611.9(8) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
TABLE R611.9(8) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e <\/td>\n<\/tr>\n
583<\/td>\nFIGURE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
FIGURE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
584<\/td>\nTABLE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e
TABLE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d, e <\/td>\n<\/tr>\n
585<\/td>\nFIGURE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL
FIGURE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PARALLEL <\/td>\n<\/tr>\n
586<\/td>\nTABLE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
TABLE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e <\/td>\n<\/tr>\n
587<\/td>\nFIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
FIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR <\/td>\n<\/tr>\n
588<\/td>\nTABLE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d
TABLE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa, b, c, d <\/td>\n<\/tr>\n
589<\/td>\nFIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
FIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL <\/td>\n<\/tr>\n
590<\/td>\nTABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e
TABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLELa, b, c, d, e <\/td>\n<\/tr>\n
591<\/td>\nSECTION R612 – EXTERIOR WINDOWS AND DOORS
SECTION R612 – EXTERIOR WINDOWS AND DOORS
FIGURE R612.2 WINDOW SILL HEIGHT
FIGURE R612.2 WINDOW SILL HEIGHT <\/td>\n<\/tr>\n
593<\/td>\nFIGURE R612.8(1) THROUGH THE FRAME
FIGURE R612.8(1) THROUGH THE FRAME
FIGURE R612.8(2) FRAME CLIP
FIGURE R612.8(2) FRAME CLIP
FIGURE R612.8(3) THROUGH THE FRAME
FIGURE R612.8(3) THROUGH THE FRAME
FIGURE R612.8(4) FRAME CLIP
FIGURE R612.8(4) FRAME CLIP <\/td>\n<\/tr>\n
594<\/td>\nFIGURE R612.8(5) THROUGH THE FLANGE
FIGURE R612.8(5) THROUGH THE FLANGE
FIGURE R612.8(6) THROUGH THE FLANGE
FIGURE R612.8(6) THROUGH THE FLANGE
FIGURE R612.8(7) FRAME CLIP
FIGURE R612.8(7) FRAME CLIP
FIGURE R612.8(8) THROUGH THE FLANGE
FIGURE R612.8(8) THROUGH THE FLANGE <\/td>\n<\/tr>\n
595<\/td>\nSECTION R613 – STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
SECTION R613 – STRUCTURAL INSULATED PANEL WALL CONSTRUCTION <\/td>\n<\/tr>\n
596<\/td>\nTABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE
TABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE <\/td>\n<\/tr>\n
597<\/td>\nTABLE R613.3.2 MINIMUM PROPERTIESa FOR WOOD STRUCTURAL PANEL FACING MATERIAL USED IN SIP WALLS
TABLE R613.3.2 MINIMUM PROPERTIESa FOR WOOD STRUCTURAL PANEL FACING MATERIAL USED IN SIP WALLS <\/td>\n<\/tr>\n
598<\/td>\nFIGURE R613.4 SIP WALL PANEL
FIGURE R613.4 SIP WALL PANEL <\/td>\n<\/tr>\n
599<\/td>\nTABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (inches)
TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (inches) <\/td>\n<\/tr>\n
600<\/td>\nTABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches
TABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches <\/td>\n<\/tr>\n
601<\/td>\nFIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS <\/td>\n<\/tr>\n
602<\/td>\nFIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R613.5(4) SIP WALL TO WALL PLATFORM FRAME CONNECTION
FIGURE R613.5(4) SIP WALL TO WALL PLATFORM FRAME CONNECTION <\/td>\n<\/tr>\n
603<\/td>\nFIGURE R613.5(5) SIP WALL TO WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only
FIGURE R613.5(5) SIP WALL TO WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only
FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION
FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION <\/td>\n<\/tr>\n
604<\/td>\nFIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT <\/td>\n<\/tr>\n
605<\/td>\nFIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
FIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
FIGURE R613.9 SIP CORNER FRAMING DETAIL
FIGURE R613.9 SIP CORNER FRAMING DETAIL <\/td>\n<\/tr>\n
606<\/td>\nTABLE R614.10 MAXIMUM SPANS FOR 117\/8 INCH DEEP SIP HEADERS (feet)
TABLE R614.10 MAXIMUM SPANS FOR 117\/8 INCH DEEP SIP HEADERS (feet)
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
609<\/td>\nCHAPTER 7: WALL COVERING
CHAPTER 7: WALL COVERING
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R701 – GENERAL
SECTION R701 – GENERAL
SECTION R702 – INTERIOR COVERING
SECTION R702 – INTERIOR COVERING <\/td>\n<\/tr>\n
610<\/td>\nFIGURE R701.2(1) PLASTER WALL COVERING\u2014APPLICABLE TERMS
FIGURE R701.2(1) PLASTER WALL COVERING\u2014APPLICABLE TERMS
FIGURE R701.2(2) GYPSUM APPLICATION\u2013APPLICABLE TERMS
FIGURE R701.2(2) GYPSUM APPLICATION\u2013APPLICABLE TERMS <\/td>\n<\/tr>\n
611<\/td>\nTABLE R702.1(1) THICKNESS OF PLASTER
TABLE R702.1(1) THICKNESS OF PLASTER
TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa <\/td>\n<\/tr>\n
612<\/td>\nTABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME <\/td>\n<\/tr>\n
613<\/td>\nFIGURE R702.2(1) INTERIOR PLASTERING SYSTEM
FIGURE R702.2(1) INTERIOR PLASTERING SYSTEM
FIGURE R702.2(2) VENEER PLASTER SYSTEM
FIGURE R702.2(2) VENEER PLASTER SYSTEM <\/td>\n<\/tr>\n
614<\/td>\nFIGURE R702.3.2(1) INTERIOR WALL COVERING-DIRECT APPLICATION
FIGURE R702.3.2(1) INTERIOR WALL COVERING-DIRECT APPLICATION <\/td>\n<\/tr>\n
615<\/td>\nFIGURE R702.3.2(2) INTERIOR WALL COVERING\u2014FURRED APPLICATION OVER MASONRY OR CONCRETE
FIGURE R702.3.2(2) INTERIOR WALL COVERING\u2014FURRED APPLICATION OVER MASONRY OR CONCRETE
FIGURE R702.3.2(3) INTERIOR WALL COVERING\u2014FURRED APPLICATION OVER SOLID BACKING OR OVER STUDS
FIGURE R702.3.2(3) INTERIOR WALL COVERING\u2014FURRED APPLICATION OVER SOLID BACKING OR OVER STUDS <\/td>\n<\/tr>\n
617<\/td>\nTABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD
TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD <\/td>\n<\/tr>\n
618<\/td>\nFIGURE R702.3.5(1) GYPSUM BOARD APPLICATION
FIGURE R702.3.5(1) GYPSUM BOARD APPLICATION
FIGURE R702.3.5(2) GYPSUM BOARD\u2014SINGLE-NAILING APPLICATION
FIGURE R702.3.5(2) GYPSUM BOARD\u2014SINGLE-NAILING APPLICATION
FIGURE R702.3.5(3) GYPSUM BOARD\u2014DOUBLE-NAILING APPLICATION
FIGURE R702.3.5(3) GYPSUM BOARD\u2014DOUBLE-NAILING APPLICATION <\/td>\n<\/tr>\n
619<\/td>\nTABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
FIGURE R702.3.7(1) HORIZONTAL GYPSUM BOARD CEILING DIAPHRAGM CONSTRUCTION
FIGURE R702.3.7(1) HORIZONTAL GYPSUM BOARD CEILING DIAPHRAGM CONSTRUCTION <\/td>\n<\/tr>\n
620<\/td>\nFIGURE R702.3.7(2) PERIMETER BLOCKING
FIGURE R702.3.7(2) PERIMETER BLOCKING <\/td>\n<\/tr>\n
621<\/td>\nFIGURE R702.4.1 INTERIOR WALL TILE INSTALLATION
FIGURE R702.4.1 INTERIOR WALL TILE INSTALLATION
FIGURE R702.4.2 EXAMPLE OF WALL TILE INSTALLATION TUB AND SHOWER AREA
FIGURE R702.4.2 EXAMPLE OF WALL TILE INSTALLATION TUB AND SHOWER AREA <\/td>\n<\/tr>\n
622<\/td>\nSECTION R703 – EXTERIOR COVERING
SECTION R703 – EXTERIOR COVERING <\/td>\n<\/tr>\n
624<\/td>\nFIGURE R703.1 TYPICAL WOOD STUD WALL CONSTRUCTION
FIGURE R703.1 TYPICAL WOOD STUD WALL CONSTRUCTION <\/td>\n<\/tr>\n
625<\/td>\nFIGURE R703.3.1(1) VERTICAL JOINT TREATMENT OF PANEL SIDING
FIGURE R703.3.1(1) VERTICAL JOINT TREATMENT OF PANEL SIDING
FIGURE R703.3.1(2) HORIZONTAL JOINT TREATMENT OF PANEL SIDING
FIGURE R703.3.1(2) HORIZONTAL JOINT TREATMENT OF PANEL SIDING <\/td>\n<\/tr>\n
626<\/td>\nTABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c
TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c <\/td>\n<\/tr>\n
627<\/td>\nTABLE R703.4 WEATHER\u2013RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
TABLE R703.4 WEATHER\u2013RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS <\/td>\n<\/tr>\n
628<\/td>\nTABLE R703.4\u2014continued WEATHER\u2013RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS
TABLE R703.4\u2014continued WEATHER\u2013RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS <\/td>\n<\/tr>\n
629<\/td>\nFIGURE R703.6(1) EXTERIOR PLASTERING SYSTEM
FIGURE R703.6(1) EXTERIOR PLASTERING SYSTEM
FIGURE R703.6(2) EXTERIOR PLASTER\u2014WOOD FRAME ON CONCRETE FLOOR SLAB
FIGURE R703.6(2) EXTERIOR PLASTER\u2014WOOD FRAME ON CONCRETE FLOOR SLAB <\/td>\n<\/tr>\n
630<\/td>\nFIGURE R703.6(3) WEEP SCREED FOR EXTERIOR PLASTER ON STUD WALL AT SLAB ON GRADE
FIGURE R703.6(3) WEEP SCREED FOR EXTERIOR PLASTER ON STUD WALL AT SLAB ON GRADE <\/td>\n<\/tr>\n
633<\/td>\nFIGURE R703.7 MASONRY VENEER WALL DETAILS
FIGURE R703.7 MASONRY VENEER WALL DETAILS <\/td>\n<\/tr>\n
634<\/td>\nFIGURE R703.7\u2013continued MASONRY VENEER WALL DETAILS
FIGURE R703.7\u2013continued MASONRY VENEER WALL DETAILS <\/td>\n<\/tr>\n
635<\/td>\nTABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.7(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, WOOD FRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
TABLE R703.7(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, WOOD FRAMING, SEISMIC DESIGN CATEGORIES D0, D1 AND D2 <\/td>\n<\/tr>\n
636<\/td>\nFIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS <\/td>\n<\/tr>\n
637<\/td>\nTABLE R703.7.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
TABLE R703.7.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
TABLE R703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
TABLE R703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d <\/td>\n<\/tr>\n
638<\/td>\nFIGURE R703.7.3.2 MASONRY VENEER OPENING
FIGURE R703.7.3.2 MASONRY VENEER OPENING <\/td>\n<\/tr>\n
640<\/td>\nFIGURE R703.8 FLASHING EXAMPLES
FIGURE R703.8 FLASHING EXAMPLES <\/td>\n<\/tr>\n
642<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
645<\/td>\nCHAPTER 8: ROOF-CEILING CONSTRUCTION
CHAPTER 8: ROOF-CEILING CONSTRUCTION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R801 – GENERAL
SECTION R801 – GENERAL
SECTION R802 – WOOD ROOF FRAMING
SECTION R802 – WOOD ROOF FRAMING <\/td>\n<\/tr>\n
648<\/td>\nFIGURE R802.3(1) RIDGE BOARD
FIGURE R802.3(1) RIDGE BOARD <\/td>\n<\/tr>\n
649<\/td>\nFIGURE R802.3(2) RIDGE ALTERNATIVE\u2014GUSSET PLATE TIE
FIGURE R802.3(2) RIDGE ALTERNATIVE\u2014GUSSET PLATE TIE
FIGURE R802.3.1(1) CEILING JOIST AT SUPPORTS
FIGURE R802.3.1(1) CEILING JOIST AT SUPPORTS <\/td>\n<\/tr>\n
650<\/td>\nFIGURE R802.3.1(2) ROOF FRAMING WITH CEILING JOISTS NOT PARALLEL TO RAFTERS
FIGURE R802.3.1(2) ROOF FRAMING WITH CEILING JOISTS NOT PARALLEL TO RAFTERS
FIGURE R802.3.1(3) ROOF FRAMING WITH CEILING JOISTS PARALLEL TO RAFTERS
FIGURE R802.3.1(3) ROOF FRAMING WITH CEILING JOISTS PARALLEL TO RAFTERS <\/td>\n<\/tr>\n
651<\/td>\nFIGURE R802.3.2(1) LAPPED CEILING JOIST CONNECTION PROVIDING RESISTANCE TO RAFTER THRUST
FIGURE R802.3.2(1) LAPPED CEILING JOIST CONNECTION PROVIDING RESISTANCE TO RAFTER THRUST
FIGURE R802.3.2(2) BUTTED CEILING JOIST CONNECTION PROVIDING RESISTANCE TO RAFTER THRUST
FIGURE R802.3.2(2) BUTTED CEILING JOIST CONNECTION PROVIDING RESISTANCE TO RAFTER THRUST <\/td>\n<\/tr>\n
652<\/td>\nTABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L\/\u00ce\u201d = 240)
TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
653<\/td>\nTABLE R802.4(1)\u2014continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
TABLE R802.4(1)\u2014continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES <\/td>\n<\/tr>\n
654<\/td>\nTABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L\/\u00ce\u201d = 240)
TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
655<\/td>\nTABLE R802.4(2)\u2014continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics with limited storage, live load = 20 psf, L\/\u00ce\u201d = 240)
TABLE R802.4(2)\u2014continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics with limited storage, live load = 20 psf, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
656<\/td>\nTABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
657<\/td>\nTABLE R802.5.1(1)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(1)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
658<\/td>\nTABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
659<\/td>\nTABLE R802.5.1(2)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(2)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load=20 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
660<\/td>\nTABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
661<\/td>\nTABLE R802.5.1(3)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(3)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=30 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
662<\/td>\nTABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
663<\/td>\nTABLE R802.5.1(4)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(4)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
664<\/td>\nTABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
665<\/td>\nTABLE R802.5.1(5)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(5)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
666<\/td>\nTABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
667<\/td>\nTABLE R802.5.1(6)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(6)\u2014continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load=50 psf, ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
668<\/td>\nTABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L\/\u00ce\u201d = 180)
TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L\/\u00ce\u201d = 180) <\/td>\n<\/tr>\n
669<\/td>\nTABLE R802.5.1(7)\u2014continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD
TABLE R802.5.1(7)\u2014continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD <\/td>\n<\/tr>\n
670<\/td>\nTABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L\/\u00ce\u201d = 240)
TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L\/\u00ce\u201d = 240) <\/td>\n<\/tr>\n
671<\/td>\nTABLE R802.5.1(8)\u2014continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOADa
TABLE R802.5.1(8)\u2014continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOADa <\/td>\n<\/tr>\n
672<\/td>\nTABLE R802.5.1(9) RAFTER\/CEILING JOIST HEEL JOINT CONNECTIONS
TABLE R802.5.1(9) RAFTER\/CEILING JOIST HEEL JOINT CONNECTIONS <\/td>\n<\/tr>\n
673<\/td>\nFIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION <\/td>\n<\/tr>\n
674<\/td>\nFIGURE R802.5.1(1) EXAMPLE OF PURLIN INSTALLATION
FIGURE R802.5.1(1) EXAMPLE OF PURLIN INSTALLATION <\/td>\n<\/tr>\n
677<\/td>\nTABLE R802.11 – REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCES
TABLE R802.11 – REQUIRED STRENGTH OF TRUSS OR RAFTER CONNECTIONS TO RESIST WIND UPLIFT FORCES <\/td>\n<\/tr>\n
678<\/td>\nSECTION R803 – ROOF SHEATHING
SECTION R803 – ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 – STEEL ROOF FRAMING
SECTION R804 – STEEL ROOF FRAMING <\/td>\n<\/tr>\n
679<\/td>\nFIGURE R804.1.2 IN-LINE FRAMING
FIGURE R804.1.2 IN-LINE FRAMING <\/td>\n<\/tr>\n
680<\/td>\nTABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE R804.2(1) LOAD-BEARING COLD-FORMED STEEL MEMBER SIZES
TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
TABLE R804.2(2) MINIMUM THICKNESS OF COLD-FORMED STEEL MEMBERS
FIGURE R804.2(1) C-SHAPED SECTION
FIGURE R804.2(1) C-SHAPED SECTION
FIGURE R804.2(2) TRACK SECTION
FIGURE R804.2(2) TRACK SECTION <\/td>\n<\/tr>\n
681<\/td>\nTABLE R804.2.4 SCREW SUBSTITUTION FACTOR
TABLE R804.2.4 SCREW SUBSTITUTION FACTOR <\/td>\n<\/tr>\n
682<\/td>\nFIGURE R804.2.5.1 WEB HOLES
FIGURE R804.2.5.1 WEB HOLES
FIGURE R804.2.5.3 WEB HOLE PATCH
FIGURE R804.2.5.3 WEB HOLE PATCH <\/td>\n<\/tr>\n
683<\/td>\nFIGURE R804.3 STEEL ROOF CONSTRUCTION
FIGURE R804.3 STEEL ROOF CONSTRUCTION <\/td>\n<\/tr>\n
684<\/td>\nTABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa, b
TABLE R804.3 ROOF FRAMING FASTENING SCHEDULEa, b <\/td>\n<\/tr>\n
685<\/td>\nTABLE R804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
TABLE R804.3.1.1(1) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
686<\/td>\nTABLE R804.3.1.1(2) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL
TABLE R804.3.1.1(2) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
687<\/td>\nTABLE R804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
TABLE R804.3.1.1(3) CEILING JOIST SPANS SINGLE SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
688<\/td>\nTABLE R804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL
TABLE R804.3.1.1(4) CEILING JOIST SPANS TWO EQUAL SPANS WITH BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
689<\/td>\nTABLE R804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
TABLE R804.3.1.1(5) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL <\/td>\n<\/tr>\n
690<\/td>\nTABLE R804.3.1.1(6) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL
TABLE R804.3.1.1(6) CEILING JOIST SPANSTWO EQUAL SPANS WITHOUT BEARING STIFFENERS 10 lb per sq ft LIVE LOAD (NO ATTIC STORAGE)a, b 33 ksi STEEL <\/td>\n<\/tr>\n
691<\/td>\nTABLE R804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
TABLE R804.3.1.1(7) CEILING JOIST SPANS SINGLE SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL <\/td>\n<\/tr>\n
692<\/td>\nTABLE R804.3.1.1(8) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL
TABLE R804.3.1.1(8) CEILING JOIST SPANS TWO EQUAL SPANS WITHOUT BEARING STIFFENERS 20 lb per sq ft LIVE LOAD (LIMITED ATTIC STORAGE)a, b 33 ksi STEEL <\/td>\n<\/tr>\n
693<\/td>\nTABLE R804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
TABLE R804.3.1.1(9) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
FIGURE R804.3.1.1(1) JOIST TO RAFTER CONNECTION
FIGURE R804.3.1.1(1) JOIST TO RAFTER CONNECTION <\/td>\n<\/tr>\n
694<\/td>\nFIGURE R804.3.1.1(2) BEARING STIFFENER
FIGURE R804.3.1.1(2) BEARING STIFFENER <\/td>\n<\/tr>\n
695<\/td>\nFIGURE R804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL
FIGURE R804.3.1.4(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPE, TRACK OR COLD-ROLLED CHANNEL
FIGURE R804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE R804.3.1.4(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING <\/td>\n<\/tr>\n
696<\/td>\nFIGURE R804.3.1.5 SPLICED CEILING JOISTS
FIGURE R804.3.1.5 SPLICED CEILING JOISTS <\/td>\n<\/tr>\n
697<\/td>\nTABLE R804.3.2.1(1) ROOF RAFTER SPANSa, b, c 33 ksi STEEL
TABLE R804.3.2.1(1) ROOF RAFTER SPANSa, b, c 33 ksi STEEL <\/td>\n<\/tr>\n
698<\/td>\nTABLE R804.3.2.1(2) ROOF RAFTER SPANSa, b, c 50 ksi STEEL
TABLE R804.3.2.1(2) ROOF RAFTER SPANSa, b, c 50 ksi STEEL <\/td>\n<\/tr>\n
699<\/td>\nTABLE R804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
TABLE R804.3.2.1(3) BASIC WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION <\/td>\n<\/tr>\n
700<\/td>\nFIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS <\/td>\n<\/tr>\n
701<\/td>\nTABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTERTO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR HIP RAFTERTO HIP MEMBER OR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
FIGURE R804.3.2.4 HIP MEMBER OF RIDGE MEMBER CONNECTION
FIGURE R804.3.2.4 HIP MEMBER OF RIDGE MEMBER CONNECTION <\/td>\n<\/tr>\n
702<\/td>\nTABLE R804.3.3.2 HIP MEMBER SIZES, 33 ksi STEEL
TABLE R804.3.3.2 HIP MEMBER SIZES, 33 ksi STEEL <\/td>\n<\/tr>\n
703<\/td>\nTABLE R804.3.3.3 HIP SUPPORT COLUMN SIZES
TABLE R804.3.3.3 HIP SUPPORT COLUMN SIZES <\/td>\n<\/tr>\n
704<\/td>\nTABLE R804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE
TABLE R804.3.3.4(1) UPLIFT STRAP CONNECTION REQUIREMENTS HIP SUPPORT COLUMN AT CEILING LINE
FIGURE R804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE
FIGURE R804.3.3.4(1) JACK RAFTER CONNECTION AT EAVE <\/td>\n<\/tr>\n
705<\/td>\nTABLE R804.3.3.4(2) CONNECTION REQUIREMENTS HIP MEMBER TO HIP SUPPORT COLUMN
TABLE R804.3.3.4(2) CONNECTION REQUIREMENTS HIP MEMBER TO HIP SUPPORT COLUMN
FIGURE R804.3.3.4(2) HIP SUPPORT COLUMN
FIGURE R804.3.3.4(2) HIP SUPPORT COLUMN <\/td>\n<\/tr>\n
706<\/td>\nTABLE R804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL
TABLE R804.3.3.4(3) UPLIFT STRAP CONNECTION REQUIREMENTS HIP MEMBER TO WALL
FIGURE R804.3.3.4(3) HIP CONNECTIONS AT RIDGE
FIGURE R804.3.3.4(3) HIP CONNECTIONS AT RIDGE <\/td>\n<\/tr>\n
707<\/td>\nFIGURE R804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND COX COLUMN
FIGURE R804.3.3.4(4) HIP CONNECTIONS AT RIDGE AND COX COLUMN <\/td>\n<\/tr>\n
708<\/td>\nFIGURE R804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER
FIGURE R804.3.3.4(5) HIP MEMBER CONNECTION AT WALL CORNER
FIGURE R804.3.6(1) ROOF OR CEILING OPENING
FIGURE R804.3.6(1) ROOF OR CEILING OPENING <\/td>\n<\/tr>\n
709<\/td>\nFIGURE R804.3.6(2) HEADER TO TRIMMER CONNECTION
FIGURE R804.3.6(2) HEADER TO TRIMMER CONNECTION <\/td>\n<\/tr>\n
710<\/td>\nTABLE R804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FT a, b, c, d, e, f
TABLE R804.3.8(1) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FT a, b, c, d, e, f
FIGURE R804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
FIGURE R804.3.8(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL <\/td>\n<\/tr>\n
711<\/td>\nTABLE R804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FTa, b, c, d, e, f
TABLE R804.3.8(2) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED CEILING HEIGHT = 9 OR 10 FTa, b, c, d, e, f
FIGURE R804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
FIGURE R804.3.8(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL <\/td>\n<\/tr>\n
712<\/td>\nTABLE R804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FTa, b, c, d
TABLE R804.3.8(3) REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS WOOD STRUCTURAL PANEL SHEATHED CEILING HEIGHT = 8, 9 OR 10 FTa, b, c, d <\/td>\n<\/tr>\n
713<\/td>\nFIGURE R804.3.8(3) ROOF LOCKING DETAIL
FIGURE R804.3.8(3) ROOF LOCKING DETAIL
SECTION R805 – CEILING FINISHES
SECTION R805 – CEILING FINISHES
SECTION R806 – ROOF VENTILATION
SECTION R806 – ROOF VENTILATION <\/td>\n<\/tr>\n
715<\/td>\nTABLE R806.4 INSULATION FOR CONDENSATION CONTROL
TABLE R806.4 INSULATION FOR CONDENSATION CONTROL <\/td>\n<\/tr>\n
716<\/td>\nSECTION R807 – ATTIC ACCESS
SECTION R807 – ATTIC ACCESS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
717<\/td>\nCHAPTER 9: ROOF ASSEMBLIES
CHAPTER 9: ROOF ASSEMBLIES
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R901 – GENERAL
SECTION R901 – GENERAL
SECTION R902 – ROOF CLASSIFICATION
SECTION R902 – ROOF CLASSIFICATION <\/td>\n<\/tr>\n
718<\/td>\nSECTION R903 – WEATHER PROTECTION
SECTION R903 – WEATHER PROTECTION <\/td>\n<\/tr>\n
720<\/td>\nFIGURE R903.5 HAIL EXPOSURE MAP
FIGURE R903.5 HAIL EXPOSURE MAP <\/td>\n<\/tr>\n
721<\/td>\nSECTION R904 – MATERIALS
SECTION R904 – MATERIALS
SECTION R905 – REQUIREMENTS FOR ROOF COVERINGS
SECTION R905 – REQUIREMENTS FOR ROOF COVERINGS <\/td>\n<\/tr>\n
722<\/td>\nFIGURE R905.2.2(1) ASPHALT ROOFING SHINGLES APPLICATION HIGH SLOPE (4:12 MINIMUM)
FIGURE R905.2.2(1) ASPHALT ROOFING SHINGLES APPLICATION HIGH SLOPE (4:12 MINIMUM)
FIGURE R905.2.2(2) APPLICATION OF ASPHALT SHINGLE SLOPES BETWEEN 2:12 AND 4:12
FIGURE R905.2.2(2) APPLICATION OF ASPHALT SHINGLE SLOPES BETWEEN 2:12 AND 4:12 <\/td>\n<\/tr>\n
723<\/td>\nTABLE R905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158
TABLE R905.2.4.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158
TABLE R905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
TABLE R905.2.4.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 <\/td>\n<\/tr>\n
725<\/td>\nFIGURE R905.2.7 LOW-SLOPE DOUBLE-PLY UNDERLAYMENT APPLICATION
FIGURE R905.2.7 LOW-SLOPE DOUBLE-PLY UNDERLAYMENT APPLICATION <\/td>\n<\/tr>\n
726<\/td>\nFIGURE R905.2.7.1(1) POSSIBLE WATER DAMAGE FROM AN ICE DAM
FIGURE R905.2.7.1(1) POSSIBLE WATER DAMAGE FROM AN ICE DAM
FIGURE R905.2.7.1(2) PROTECTIVE ICE BARRIER
FIGURE R905.2.7.1(2) PROTECTIVE ICE BARRIER <\/td>\n<\/tr>\n
727<\/td>\nTABLE R905.2.8.2 VALLEY LINING MATERIAL
TABLE R905.2.8.2 VALLEY LINING MATERIAL
FIGURE R905.2.8.2(1) FLASHING FOR OPEN ROOF VALLEY
FIGURE R905.2.8.2(1) FLASHING FOR OPEN ROOF VALLEY
FIGURE R905.2.8.2(2) FLASHING FOR WOVEN VALLEY
FIGURE R905.2.8.2(2) FLASHING FOR WOVEN VALLEY <\/td>\n<\/tr>\n
728<\/td>\nFIGURE R905.2.8.3 FLASHING AT SIDE WALL
FIGURE R905.2.8.3 FLASHING AT SIDE WALL
FIGURE R905.2.8.4 CHIMNEY FLASHING DETAIL
FIGURE R905.2.8.4 CHIMNEY FLASHING DETAIL <\/td>\n<\/tr>\n
729<\/td>\nFIGURE R905.3 ROLL AND FLAT TILE EXAMPLES
FIGURE R905.3 ROLL AND FLAT TILE EXAMPLES <\/td>\n<\/tr>\n
730<\/td>\nTABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT <\/td>\n<\/tr>\n
731<\/td>\nFIGURE R905.3.7(1) APPLICATION OF ROLL TILE
FIGURE R905.3.7(1) APPLICATION OF ROLL TILE
FIGURE R905.3.7(2) TILE ROOF GABLE RAKE SECTION
FIGURE R905.3.7(2) TILE ROOF GABLE RAKE SECTION <\/td>\n<\/tr>\n
732<\/td>\nFIGURE R905.2.7(3) TILE ROOF EAVE SECTION
FIGURE R905.2.7(3) TILE ROOF EAVE SECTION
FIGURE R905.3.7(4) TILE ROOF RIDGE SECTION
FIGURE R905.3.7(4) TILE ROOF RIDGE SECTION <\/td>\n<\/tr>\n
733<\/td>\nFIGURE R905.3.8(1) TILE ROOF FLASHING AT VALLEY
FIGURE R905.3.8(1) TILE ROOF FLASHING AT VALLEY
FIGURE R905.3.8(2) TILE ROOF FLASHING AT ROOF ABUTTING CHIMNEY\/WALL
FIGURE R905.3.8(2) TILE ROOF FLASHING AT ROOF ABUTTING CHIMNEY\/WALL
FIGURE R905.3.8(3) TILE ROOF CHIMNEY FLASHING DETAIL
FIGURE R905.3.8(3) TILE ROOF CHIMNEY FLASHING DETAIL
FIGURE R905.3.8(4) TILE ROOF FLASHING FOR A VENT PIPE
FIGURE R905.3.8(4) TILE ROOF FLASHING FOR A VENT PIPE <\/td>\n<\/tr>\n
736<\/td>\nTABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.6.5 SLATE SHINGLE HEADLAP <\/td>\n<\/tr>\n
737<\/td>\nTABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
FIGURE R905.7.4 WOOD SHINGLE GRADE DESCRIPTION AND EXAMPLE LABEL
FIGURE R905.7.4 WOOD SHINGLE GRADE DESCRIPTION AND EXAMPLE LABEL <\/td>\n<\/tr>\n
738<\/td>\nFIGURE R905.7.5(1) WOOD SHINGLE APPLICATION
FIGURE R905.7.5(1) WOOD SHINGLE APPLICATION
FIGURE R905.7.5(2) FASTENER PENETRATION
FIGURE R905.7.5(2) FASTENER PENETRATION <\/td>\n<\/tr>\n
739<\/td>\nTABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.7.5 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
FIGURE R905.7.6 WOOD SHINGLE VALLEY FLASHING
FIGURE R905.7.6 WOOD SHINGLE VALLEY FLASHING <\/td>\n<\/tr>\n
740<\/td>\nTABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS <\/td>\n<\/tr>\n
741<\/td>\nTABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE <\/td>\n<\/tr>\n
742<\/td>\nFIGURE R905.8.6 WOOD SHAKE APPLICATION
FIGURE R905.8.6 WOOD SHAKE APPLICATION
FIGURE R905.8.7 WOOD SHAKE APPLICATION ON ROOFS WITH SLOPES NOT LESS THAN 3 IN 12
FIGURE R905.8.7 WOOD SHAKE APPLICATION ON ROOFS WITH SLOPES NOT LESS THAN 3 IN 12 <\/td>\n<\/tr>\n
743<\/td>\nFIGURE R905.8.9 WOOD SHAKE DESCRIPTION AND EXAMPLE LABELS
FIGURE R905.8.9 WOOD SHAKE DESCRIPTION AND EXAMPLE LABELS <\/td>\n<\/tr>\n
744<\/td>\nTABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS <\/td>\n<\/tr>\n
745<\/td>\nFIGURE R905.9.3(1) BUILT-UP ROOF\u2014NAILABLE DECK APPLICATION
FIGURE R905.9.3(1) BUILT-UP ROOF\u2014NAILABLE DECK APPLICATION <\/td>\n<\/tr>\n
746<\/td>\nFIGURE R905.9.3(2) BUILT-UP ROOF-APPLICATION TO NONNAILABLE DECK BY SPOT MOPPING
FIGURE R905.9.3(2) BUILT-UP ROOF-APPLICATION TO NONNAILABLE DECK BY SPOT MOPPING
FIGURE R905.9.3(3) BUILT-UP-APPLICATION TO NONNAILABLE DECK BY SOLID MOPPING
FIGURE R905.9.3(3) BUILT-UP-APPLICATION TO NONNAILABLE DECK BY SOLID MOPPING <\/td>\n<\/tr>\n
747<\/td>\nTABLE R905.10.3(1) METAL ROOF COVERINGS STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERINGS STANDARDS <\/td>\n<\/tr>\n
748<\/td>\nTABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS <\/td>\n<\/tr>\n
750<\/td>\nSECTION R906 – ROOF INSULATION
SECTION R906 – ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION <\/td>\n<\/tr>\n
751<\/td>\nSECTION R907 – REROOFING
SECTION R907 – REROOFING <\/td>\n<\/tr>\n
752<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
757<\/td>\nCHAPTER 10: CHIMNEYS AND FIREPLACES
CHAPTER 10: CHIMNEYS AND FIREPLACES
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION R1001 – MASONRY FIREPLACES
SECTION R1001 – MASONRY FIREPLACES <\/td>\n<\/tr>\n
758<\/td>\nTABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS <\/td>\n<\/tr>\n
759<\/td>\nFIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS <\/td>\n<\/tr>\n
761<\/td>\nFIGURE R1001.6(1) SECTION THROUGH FIREPLACE
FIGURE R1001.6(1) SECTION THROUGH FIREPLACE <\/td>\n<\/tr>\n
762<\/td>\nFIGURE R1001.6(2) RUMFORD FIREPLACE
FIGURE R1001.6(2) RUMFORD FIREPLACE <\/td>\n<\/tr>\n
764<\/td>\nSECTION R1002 – MASONRY HEATERS
SECTION R1002 – MASONRY HEATERS
FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES <\/td>\n<\/tr>\n
765<\/td>\nSECTION R1003 – MASONRY CHIMNEYS
SECTION R1003 – MASONRY CHIMNEYS <\/td>\n<\/tr>\n
766<\/td>\nFIGURE R1003.2 TYPICAL MASONRY CHIMNEY
FIGURE R1003.2 TYPICAL MASONRY CHIMNEY <\/td>\n<\/tr>\n
767<\/td>\nFIGURE R1003.5(1) INDIVIDUAL CORBELS
FIGURE R1003.5(1) INDIVIDUAL CORBELS
FIGURE R1003.5(2) CORBELING FROM FOUNDATION WALL
FIGURE R1003.5(2) CORBELING FROM FOUNDATION WALL <\/td>\n<\/tr>\n
770<\/td>\nFIGURE R1003.12 MULTIPLE FLUES
FIGURE R1003.12 MULTIPLE FLUES <\/td>\n<\/tr>\n
771<\/td>\nTABLE R1003.14(1) NET CROSS\u2013SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(1) NET CROSS\u2013SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS\u2013SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
TABLE R1003.14(2) NET CROSS\u2013SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE R1003.15.1 MULTIPLE FLUES
FIGURE R1003.15.1 MULTIPLE FLUES <\/td>\n<\/tr>\n
772<\/td>\nFIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS <\/td>\n<\/tr>\n
773<\/td>\nFIGURE R1003.16 CHIMNEY WITH INLET\u2013MINIMUM CLEARANCES TO COMBUSTIBLE FIRESTOPPING
FIGURE R1003.16 CHIMNEY WITH INLET\u2013MINIMUM CLEARANCES TO COMBUSTIBLE FIRESTOPPING <\/td>\n<\/tr>\n
774<\/td>\nTABLE R1003.20 CRICKET DIMENSIONS
TABLE R1003.20 CRICKET DIMENSIONS
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES <\/td>\n<\/tr>\n
775<\/td>\nFIGURE R1003.20 CHIMNEY CRICKET
FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1004 – FACTORY-BUILT FIREPLACES
SECTION R1004 – FACTORY-BUILT FIREPLACES
SECTION R1005 – FACTORY-BUILT CHIMNEYS
SECTION R1005 – FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n
776<\/td>\nFIGURE R1005.6 EXAMPLE OF FACTORY-BUILT FIREPLACE AND CHIMNEY
FIGURE R1005.6 EXAMPLE OF FACTORY-BUILT FIREPLACE AND CHIMNEY
SECTION R1006 – EXTERIOR AIR SUPPLY
SECTION R1006 – EXTERIOR AIR SUPPLY <\/td>\n<\/tr>\n
779<\/td>\nPART IV – ENERGY CONSERVATION
PART IV – ENERGY CONSERVATION
CHAPTER 11: ENERGY EFFICIENCY
CHAPTER 11: ENERGY EFFICIENCY
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION N1101 – GENERAL
SECTION N1101 – GENERAL <\/td>\n<\/tr>\n
780<\/td>\nFIGURE N1101.1(1) CONDITIONED ENVELOPE
FIGURE N1101.1(1) CONDITIONED ENVELOPE
FIGURE N1101.1(2) BUILDING ENVELOPE
FIGURE N1101.1(2) BUILDING ENVELOPE <\/td>\n<\/tr>\n
781<\/td>\nFIGURE N1101.2 CLIMATE ZONES
FIGURE N1101.2 CLIMATE ZONES <\/td>\n<\/tr>\n
782<\/td>\nTABLE N1101.2 CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2 CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
783<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
784<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
785<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
786<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
787<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
788<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITO
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITO <\/td>\n<\/tr>\n
789<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
790<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITOR
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITOR <\/td>\n<\/tr>\n
791<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITO
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITO <\/td>\n<\/tr>\n
792<\/td>\nTABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE N1101.2\u2014continued CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY <\/td>\n<\/tr>\n
793<\/td>\nFIGURE N1101.3(1) INSULATION R-VALUE STAMP
FIGURE N1101.3(1) INSULATION R-VALUE STAMP
FIGURE N1101.3(2) NATIONAL FENESTRATION RATING COUNCIL LABEL
FIGURE N1101.3(2) NATIONAL FENESTRATION RATING COUNCIL LABEL <\/td>\n<\/tr>\n
794<\/td>\nTABLE N1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE N1101.5(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE N1101.5(2) DEFAULT DOOR U-FACTORS
TABLE N1101.5(2) DEFAULT DOOR U-FACTORS
TABLE N1101.5(3) DEFAULT GLAZED FENESTRATION SHGC
TABLE N1101.5(3) DEFAULT GLAZED FENESTRATION SHGC <\/td>\n<\/tr>\n
796<\/td>\nFIGURE N1101.9 CERTIFICATE
FIGURE N1101.9 CERTIFICATE <\/td>\n<\/tr>\n
797<\/td>\nSECTION N1102 – BUILDING THERMAL ENVELOPE
SECTION N1102 – BUILDING THERMAL ENVELOPE <\/td>\n<\/tr>\n
798<\/td>\nTABLE N1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE N1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa <\/td>\n<\/tr>\n
799<\/td>\nFIGURE N1102.1.1 EXTERIOR R-VALUES
FIGURE N1102.1.1 EXTERIOR R-VALUES <\/td>\n<\/tr>\n
800<\/td>\nTABLE N1102.1.2 EQUIVALENT U-FACTOR
TABLE N1102.1.2 EQUIVALENT U-FACTOR <\/td>\n<\/tr>\n
802<\/td>\nFIGURE N1102.2.1(1) TYPICAL ROOF ASSEMBLY
FIGURE N1102.2.1(1) TYPICAL ROOF ASSEMBLY <\/td>\n<\/tr>\n
803<\/td>\nFIGURE N1102.2.1(2) RAISED-HEEL TRUSS
FIGURE N1102.2.1(2) RAISED-HEEL TRUSS <\/td>\n<\/tr>\n
804<\/td>\nFIGURE 1102.2.4(1) EXTERIOR INSULATION
FIGURE 1102.2.4(1) EXTERIOR INSULATION
FIGURE 1102.2.4(2) INTERIOR INSULATION
FIGURE 1102.2.4(2) INTERIOR INSULATION <\/td>\n<\/tr>\n
805<\/td>\nTABLE N1102.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
TABLE N1102.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) <\/td>\n<\/tr>\n
806<\/td>\nFIGURE N1102.2.7(1) WALK-OUT BASEMENT
FIGURE N1102.2.7(1) WALK-OUT BASEMENT <\/td>\n<\/tr>\n
807<\/td>\nFIGURE N1102.2.7(2) WALK-OUT BASEMENT
FIGURE N1102.2.7(2) WALK-OUT BASEMENT <\/td>\n<\/tr>\n
808<\/td>\nFIGURE N1102.2.8 SLAB-EDGE INSULATION METHODS
FIGURE N1102.2.8 SLAB-EDGE INSULATION METHODS <\/td>\n<\/tr>\n
809<\/td>\nFIGURE N1102.2.9 CRAWL SPACE WALL INSULATION
FIGURE N1102.2.9 CRAWL SPACE WALL INSULATION <\/td>\n<\/tr>\n
813<\/td>\nFIGURE N1102.4 TYPICAL SOURCES OF AIR LEAKAGE
FIGURE N1102.4 TYPICAL SOURCES OF AIR LEAKAGE <\/td>\n<\/tr>\n
815<\/td>\nTABLE N1102.4.2 AIR BARRIER AND INSULATION INSPECTION
TABLE N1102.4.2 AIR BARRIER AND INSULATION INSPECTION <\/td>\n<\/tr>\n
816<\/td>\nSECTION N1103 – SYSTEMS
SECTION N1103 – SYSTEMS
FIGURE N1102.4.3 IC-RATED RECESSED LIGHT
FIGURE N1102.4.3 IC-RATED RECESSED LIGHT <\/td>\n<\/tr>\n
819<\/td>\nSECTION N1104 LIGHTING SYSTEMS
SECTION N1104 LIGHTING SYSTEMS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
821<\/td>\nINDEX
INDEX <\/td>\n<\/tr>\n
833<\/td>\nICC MEMBERSHIP BENEFITS
ICC MEMBERSHIP BENEFITS <\/td>\n<\/tr>\n
834<\/td>\nMUST HAVE TOOLS FOR YOUR IRC\u00ae
MUST HAVE TOOLS FOR YOUR IRC\u00ae <\/td>\n<\/tr>\n
835<\/td>\nNEW GUIDELINES FOR GOING GREEN
NEW GUIDELINES FOR GOING GREEN <\/td>\n<\/tr>\n
836<\/td>\nGO-TO RESOURCES FOR YOU I-CODE
GO-TO RESOURCES FOR YOU I-CODE <\/td>\n<\/tr>\n
837<\/td>\n2009 INTERNATIONAL RESIDENTIAL CODE\u00ae AND COMMENTARY VOLUME II
2009 INTERNATIONAL RESIDENTIAL CODE\u00ae AND COMMENTARY VOLUME II <\/td>\n<\/tr>\n
838<\/td>\nCOPYRIGHT\u00a92010
COPYRIGHT\u00a92010 <\/td>\n<\/tr>\n
839<\/td>\nPREFACE
PREFACE <\/td>\n<\/tr>\n
841<\/td>\nTABLE OF CONTENTS
TABLE OF CONTENTS <\/td>\n<\/tr>\n
845<\/td>\nPART V – MECHANICAL
PART V – MECHANICAL
CHAPTER 12: MECHANICAL ADMINISTRATION
CHAPTER 12: MECHANICAL ADMINISTRATION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1201 – GENERAL
SECTION M1201 – GENERAL
SECTION M1202 – EXISTING MECHANICAL SYSTEMS
SECTION M1202 – EXISTING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n
846<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
847<\/td>\nCHAPTER 13: GENERAL MECHANICAL SYSTEM REQUIREMENTS
CHAPTER 13: GENERAL MECHANICAL SYSTEM REQUIREMENTS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1301 – GENERAL
SECTION M1301 – GENERAL
SECTION M1302 – APPROVAL
SECTION M1302 – APPROVAL <\/td>\n<\/tr>\n
848<\/td>\nSECTION M1303 – LABELING OF APPLIANCES
SECTION M1303 – LABELING OF APPLIANCES
SECTION M1304 – TYPE OF FUEL
SECTION M1304 – TYPE OF FUEL <\/td>\n<\/tr>\n
849<\/td>\nFIGURE M1303.1 – TYPICAL LABEL FOR A CATEGORY I GAS-FIRED FURNACE(Courtesy of The Trane Company, and American Standard Company)
FIGURE M1303.1 – TYPICAL LABEL FOR A CATEGORY I GAS-FIRED FURNACE(Courtesy of The Trane Company, and American Standard Company)
SECTION M1305 – APPLIANCE ACCESS
SECTION M1305 – APPLIANCE ACCESS <\/td>\n<\/tr>\n
851<\/td>\nFIGURE M1305.1.3 – REMOTE LOCATION REQUIREMENTS (ATTIC INSTALLATION)
FIGURE M1305.1.3 – REMOTE LOCATION REQUIREMENTS (ATTIC INSTALLATION) <\/td>\n<\/tr>\n
852<\/td>\nSECTION M1306 – CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
SECTION M1306 – CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
FIGURE M1306.1 – REDUCED CLEARANCE DIAGRAM
FIGURE M1306.1 – REDUCED CLEARANCE DIAGRAM <\/td>\n<\/tr>\n
853<\/td>\nFIGURE M1306.2 – WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE M1306.2 – WALL PROTECTOR CLEARANCE REDUCTION SYSTEM <\/td>\n<\/tr>\n
854<\/td>\nSECTION M1307 – APPLIANCE INSTALLATION
SECTION M1307 – APPLIANCE INSTALLATION <\/td>\n<\/tr>\n
855<\/td>\nTABLE M1306.2 – REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa, c, d, e, f, g, h, I, j, k, l
TABLE M1306.2 – REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa, c, d, e, f, g, h, I, j, k, l <\/td>\n<\/tr>\n
856<\/td>\nFIGURE M1307.2 – ANCHORAGE OF WATER HEATER
FIGURE M1307.2 – ANCHORAGE OF WATER HEATER <\/td>\n<\/tr>\n
857<\/td>\nFIGURE M1307.3 – OIL-FIRED WATER HEATER INSTALLATION IN A GARAGE
FIGURE M1307.3 – OIL-FIRED WATER HEATER INSTALLATION IN A GARAGE <\/td>\n<\/tr>\n
858<\/td>\nFIGURE M1307.3.1 – TYPICAL MOTOR VEHICLE IMPACT PROTECTION
FIGURE M1307.3.1 – TYPICAL MOTOR VEHICLE IMPACT PROTECTION <\/td>\n<\/tr>\n
859<\/td>\nSECTION M1308 – MECHANICAL SYSTEMS INSTALLATION
SECTION M1308 – MECHANICAL SYSTEMS INSTALLATION <\/td>\n<\/tr>\n
860<\/td>\nFIGURE M1308.2 – PIPE PROTECTION
FIGURE M1308.2 – PIPE PROTECTION
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
863<\/td>\nCHAPTER 14: HEATING AND COOLING EQUIPMENT
CHAPTER 14: HEATING AND COOLING EQUIPMENT
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1401 – GENERAL
SECTION M1401 – GENERAL <\/td>\n<\/tr>\n
864<\/td>\nSECTION M1402 – CENTRAL FURNACES
SECTION M1402 – CENTRAL FURNACES
SECTION M1403 – HEAT PUMP EQUIPMENT
SECTION M1403 – HEAT PUMP EQUIPMENT <\/td>\n<\/tr>\n
865<\/td>\nSECTION M1404 – REFRIGERATION COOLING EQUIPMENT
SECTION M1404 – REFRIGERATION COOLING EQUIPMENT
SECTION M1405 – BASEBOARD CONVECTORS
SECTION M1405 – BASEBOARD CONVECTORS
SECTION M1406 – RADIANT HEATING SYSTEMS
SECTION M1406 – RADIANT HEATING SYSTEMS
FIGURE M1405.1 – TYPICAL ELECTRICAL BASEBOARD CONVECTOR
FIGURE M1405.1 – TYPICAL ELECTRICAL BASEBOARD CONVECTOR <\/td>\n<\/tr>\n
866<\/td>\nSECTION M1407 – DUCT HEATERS
SECTION M1407 – DUCT HEATERS
SECTION M1408 – VENTED FLOOR FURNACES
SECTION M1408 – VENTED FLOOR FURNACES <\/td>\n<\/tr>\n
867<\/td>\nFIGURE M1408.3 FLOOR FURNACE CLEARANCES
FIGURE M1408.3 FLOOR FURNACE CLEARANCES <\/td>\n<\/tr>\n
868<\/td>\nSECTION M1409 – VENTED WALL FURNACES
SECTION M1409 – VENTED WALL FURNACES
SECTION M1410 – VENTED ROOM HEATERS
SECTION M1410 – VENTED ROOM HEATERS <\/td>\n<\/tr>\n
869<\/td>\nSECTION M1411 – HEATING AND COOLING EQUIPMENT
SECTION M1411 – HEATING AND COOLING EQUIPMENT <\/td>\n<\/tr>\n
870<\/td>\nFIGURE M1411.3.1(1) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN A PAN
FIGURE M1411.3.1(1) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN A PAN
FIGURE M1411.3.1(2) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN THE OVERFLOW DRAIN LINE
FIGURE M1411.3.1(2) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN THE OVERFLOW DRAIN LINE <\/td>\n<\/tr>\n
871<\/td>\nFIGURE M1411.3.1(3) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN THE OUTLET OF THE AUXILIARY PAN
FIGURE M1411.3.1(3) – CONDENSATE OVERFLOW SHUTOFF SWITCH INSTALLED IN THE OUTLET OF THE AUXILIARY PAN
FIGURE M1411.3.3(1) – UNACCEPTABLE APPLIANCE AND PAN INSTALLATION
FIGURE M1411.3.3(1) – UNACCEPTABLE APPLIANCE AND PAN INSTALLATION <\/td>\n<\/tr>\n
872<\/td>\nFIGURE M1411.3.3(2) – ACCEPTABLE APPLIANCE AND PAN INSTALLATION
FIGURE M1411.3.3(2) – ACCEPTABLE APPLIANCE AND PAN INSTALLATION
SECTION M1412 – ABSORPTION COOLING EQUIPMENT
SECTION M1412 – ABSORPTION COOLING EQUIPMENT <\/td>\n<\/tr>\n
873<\/td>\nFIGURE M1411.6(1) – INSTALLATION OF LOCKING CAPS FOR REFRIGERANT ACCESS PORT
FIGURE M1411.6(1) – INSTALLATION OF LOCKING CAPS FOR REFRIGERANT ACCESS PORT
FIGURE M1411.6(2) – REFRIGERANT LOCKING CAPS AND TOOLS
FIGURE M1411.6(2) – REFRIGERANT LOCKING CAPS AND TOOLS
FIGURE M1411.6(3) – REFRIGERANT LABELS FOR LOCKING CAPS
FIGURE M1411.6(3) – REFRIGERANT LABELS FOR LOCKING CAPS
FIGURE M1411.6(4) – SPECIAL REMOVAL TOOLS FOR REFRIGERANT LOCKING CAPS
FIGURE M1411.6(4) – SPECIAL REMOVAL TOOLS FOR REFRIGERANT LOCKING CAPS
SECTION M1413 – EVAPORATIVE COOLING EQUIPMENT
SECTION M1413 – EVAPORATIVE COOLING EQUIPMENT <\/td>\n<\/tr>\n
874<\/td>\nSECTION 1414 – FIREPLACE STOVES
SECTION 1414 – FIREPLACE STOVES
SECTION M1415 – MASONRY HEATERS
SECTION M1415 – MASONRY HEATERS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
875<\/td>\nCHAPTER 15: EXHAUST SYSTEMS
CHAPTER 15: EXHAUST SYSTEMS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1501 GENERAL
SECTION M1501 GENERAL <\/td>\n<\/tr>\n
876<\/td>\nSECTION M1502 CLOTHES DRYER EXHAUST
SECTION M1502 CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n
878<\/td>\nTABLE M1502.4.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
TABLE M1502.4.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH <\/td>\n<\/tr>\n
879<\/td>\nSECTION M1503 RANGE HOODS
SECTION M1503 RANGE HOODS
FIGURE M1502.4.5 EXAMPLE OF A DRYER EXHAUST LENGTH LABEL
FIGURE M1502.4.5 EXAMPLE OF A DRYER EXHAUST LENGTH LABEL <\/td>\n<\/tr>\n
880<\/td>\nSECTION M1504 INSTALLATION OF MICROWAVE OVENS
SECTION M1504 INSTALLATION OF MICROWAVE OVENS
SECTION M1505 OVERHEAD EXHAUST HOODS
SECTION M1505 OVERHEAD EXHAUST HOODS <\/td>\n<\/tr>\n
881<\/td>\nSECTION M1506 EXHAUST DUCTS
SECTION M1506 EXHAUST DUCTS
SECTION M1507 MECHANICAL VENTILATION
SECTION M1507 MECHANICAL VENTILATION
TABLE M1507.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS
TABLE M1507.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
883<\/td>\nCHAPTER 16: DUCT SYSTEMS
CHAPTER 16: DUCT SYSTEMS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1601 – DUCT CONSTRUCTION
SECTION M1601 – DUCT CONSTRUCTION <\/td>\n<\/tr>\n
885<\/td>\nTABLE M1601.1.1(1) – CLASSIFICATION OF FACTORY-MADE AIR DUCTS
TABLE M1601.1.1(1) – CLASSIFICATION OF FACTORY-MADE AIR DUCTS
TABLE M1601.1.1(2) – GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING
TABLE M1601.1.1(2) – GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLING <\/td>\n<\/tr>\n
886<\/td>\nFIGURE M1601.1.1(1) – ACCEPTABLE STUD AND JOIST-SPACE INSTALLATION
FIGURE M1601.1.1(1) – ACCEPTABLE STUD AND JOIST-SPACE INSTALLATION <\/td>\n<\/tr>\n
887<\/td>\nFIGURE M1601.1.1(2) – UNACCEPTABLE STUD AND JOIST-SPACE PLENUM INSTALLATION
FIGURE M1601.1.1(2) – UNACCEPTABLE STUD AND JOIST-SPACE PLENUM INSTALLATION <\/td>\n<\/tr>\n
891<\/td>\nFIGURE M1601.4.1 – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1 – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
892<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
893<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
894<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
895<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
896<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
897<\/td>\nFIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council)
FIGURE M1601.4.1\u2014continued – INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS(Courtesy of Air Diffusion Council) <\/td>\n<\/tr>\n
898<\/td>\nFIGURE M1601.5 – UNDER-FLOOR PLENUM
FIGURE M1601.5 – UNDER-FLOOR PLENUM <\/td>\n<\/tr>\n
899<\/td>\nSECTION M1602 – RETURN AIR
SECTION M1602 – RETURN AIR <\/td>\n<\/tr>\n
900<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
901<\/td>\nCHAPTER 17: COMBUSTION AIR
CHAPTER 17: COMBUSTION AIR
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1701 – GENERAL
SECTION M1701 – GENERAL <\/td>\n<\/tr>\n
902<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
903<\/td>\nCHAPTER 18: CHIMNEYS AND VENTS
CHAPTER 18: CHIMNEYS AND VENTS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1801 – GENERAL
SECTION M1801 – GENERAL <\/td>\n<\/tr>\n
906<\/td>\nFIGURE M1801.7 – VENT SUPPORT
FIGURE M1801.7 – VENT SUPPORT <\/td>\n<\/tr>\n
907<\/td>\nSECTION M1802 – VENT COMPONENTS
SECTION M1802 – VENT COMPONENTS
FIGURE M1802.3 – DRAFT HOODS AND DRAFT REGULATORS
FIGURE M1802.3 – DRAFT HOODS AND DRAFT REGULATORS <\/td>\n<\/tr>\n
908<\/td>\nSECTION M1803 – CHIMNEY AND VENT CONNECTORS
SECTION M1803 – CHIMNEY AND VENT CONNECTORS
TABLE M1803.2 – THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS
TABLE M1803.2 – THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS <\/td>\n<\/tr>\n
909<\/td>\nTABLE M1803.3.4 – CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa
TABLE M1803.3.4 – CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALSa <\/td>\n<\/tr>\n
910<\/td>\nSECTION M1804 – VENTS
SECTION M1804 – VENTS
TABLE M1804.1 – VENT SELECTION CHART
TABLE M1804.1 – VENT SELECTION CHART <\/td>\n<\/tr>\n
911<\/td>\nFIGURE M1804.2.1 – VENT TERMINATION THROUGH A ROOF
FIGURE M1804.2.1 – VENT TERMINATION THROUGH A ROOF <\/td>\n<\/tr>\n
913<\/td>\nSECTION M1805 – MASONRY AND FACTORY-BUILT CHIMNEYS
SECTION M1805 – MASONRY AND FACTORY-BUILT CHIMNEYS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
915<\/td>\nCHAPTER 19: SPECIAL FUEL-BURNING EQUIPMENT
CHAPTER 19: SPECIAL FUEL-BURNING EQUIPMENT
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M1901 – RANGES AND OVENS
SECTION M1901 – RANGES AND OVENS
SECTION M1902 – SAUNA HEATERS
SECTION M1902 – SAUNA HEATERS <\/td>\n<\/tr>\n
916<\/td>\nSECTION M1903 – STATIONARY FUEL CELL POWER PLANTS
SECTION M1903 – STATIONARY FUEL CELL POWER PLANTS
FIGURE M1903.1(1) – TYPICAL FUEL CELL COMPONENTS
FIGURE M1903.1(1) – TYPICAL FUEL CELL COMPONENTS <\/td>\n<\/tr>\n
917<\/td>\nSECTION M1904 – GASEOUS HYDROGEN SYSTEMS
SECTION M1904 – GASEOUS HYDROGEN SYSTEMS
FIGURE M1903.1(2) – TYPICAL FUEL CELL COMPONENTS
FIGURE M1903.1(2) – TYPICAL FUEL CELL COMPONENTS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
919<\/td>\nCHAPTER 20: BOILERS AND WATER HEATERS
CHAPTER 20: BOILERS AND WATER HEATERS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M2001 – BOILERS
SECTION M2001 – BOILERS <\/td>\n<\/tr>\n
920<\/td>\nFIGURE M2001.2 – RESIDENTIAL BOILER AND ASSOCIATED EQUIPMENT
FIGURE M2001.2 – RESIDENTIAL BOILER AND ASSOCIATED EQUIPMENT
SECTION M2002 – OPERATING AND SAFETY CONTROLS
SECTION M2002 – OPERATING AND SAFETY CONTROLS <\/td>\n<\/tr>\n
921<\/td>\nFIGURE M2001.3 – MULTIPLE MODULAR UNITS
FIGURE M2001.3 – MULTIPLE MODULAR UNITS <\/td>\n<\/tr>\n
922<\/td>\nFIGURE M2002.2 – BOILER TEMPERATURE AND PRESSURE GAUGE
FIGURE M2002.2 – BOILER TEMPERATURE AND PRESSURE GAUGE
FIGURE M2002.3 – STEAM BOILER SIGHT GLASS
FIGURE M2002.3 – STEAM BOILER SIGHT GLASS <\/td>\n<\/tr>\n
923<\/td>\nSECTION M2003 – EXPANSION TANKS
SECTION M2003 – EXPANSION TANKS <\/td>\n<\/tr>\n
924<\/td>\nFIGURE M2002.5 – BOILER LOW-WATER CUTOFF CONTROL DEVICE
FIGURE M2002.5 – BOILER LOW-WATER CUTOFF CONTROL DEVICE
SECTION M2004 – WATER HEATERS USED FOR SPACE HEATING
SECTION M2004 – WATER HEATERS USED FOR SPACE HEATING <\/td>\n<\/tr>\n
925<\/td>\nTABLE M2003.2 – EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT-WATER SYSTEMS
TABLE M2003.2 – EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT-WATER SYSTEMS
SECTION M2005 – WATER HEATERS
SECTION M2005 – WATER HEATERS <\/td>\n<\/tr>\n
926<\/td>\nSECTION M2006 POOL HEATERS
SECTION M2006 POOL HEATERS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
929<\/td>\nCHAPTER 21: HYDRONIC PIPING
CHAPTER 21: HYDRONIC PIPING
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M2101 – HYDRONIC PIPING SYSTEMS INSTALLATION
SECTION M2101 – HYDRONIC PIPING SYSTEMS INSTALLATION <\/td>\n<\/tr>\n
930<\/td>\nFIGURE M2101.7 – PROHIBITED BULLHEAD TEE ARRANGEMENT
FIGURE M2101.7 – PROHIBITED BULLHEAD TEE ARRANGEMENT <\/td>\n<\/tr>\n
931<\/td>\nTABLE M2101.1 – HYDRONIC PIPING MATERIALS
TABLE M2101.1 – HYDRONIC PIPING MATERIALS <\/td>\n<\/tr>\n
932<\/td>\nTABLE M2101.9 – HANGER SPACING INTERVALS
TABLE M2101.9 – HANGER SPACING INTERVALS
SECTION M2102 – BASEBOARD CONVECTORS
SECTION M2102 – BASEBOARD CONVECTORS
SECTION M2103 – FLOOR HEATING SYSTEMS
SECTION M2103 – FLOOR HEATING SYSTEMS <\/td>\n<\/tr>\n
933<\/td>\nSECTION M2104 – LOW TEMPERATURE PIPING
SECTION M2104 – LOW TEMPERATURE PIPING <\/td>\n<\/tr>\n
934<\/td>\nFIGURE M2104.2.1.1 – HEAT-FUSED JOINT
FIGURE M2104.2.1.1 – HEAT-FUSED JOINT <\/td>\n<\/tr>\n
935<\/td>\nSECTION M2105 – GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING
SECTION M2105 – GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
937<\/td>\nCHAPTER 22: SPECIAL PIPING AND STORAGE SYSTEMS
CHAPTER 22: SPECIAL PIPING AND STORAGE SYSTEMS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M2201 – OIL TANKS
SECTION M2201 – OIL TANKS <\/td>\n<\/tr>\n
938<\/td>\nSECTION M2202 – OIL PIPING, FITTING AND CONNECTIONS
SECTION M2202 – OIL PIPING, FITTING AND CONNECTIONS <\/td>\n<\/tr>\n
939<\/td>\nSECTION M2203 – INSTALLATION
SECTION M2203 – INSTALLATION <\/td>\n<\/tr>\n
940<\/td>\nSECTION M2204 – OIL PUMPS AND VALVE
SECTION M2204 – OIL PUMPS AND VALVE
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
943<\/td>\nCHAPTER 23: SOLAR SYSTEMS
CHAPTER 23: SOLAR SYSTEMS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION M2301 – SOLAR ENERGY SYSTEMS
SECTION M2301 – SOLAR ENERGY SYSTEMS <\/td>\n<\/tr>\n
944<\/td>\nFIGURE 23(1) – PASSIVE SOLAR SPACE HEATING
FIGURE 23(1) – PASSIVE SOLAR SPACE HEATING
FIGURE 23(2) – PASSIVE SOLAR HEATING AND COOLING APPLICATIONS
FIGURE 23(2) – PASSIVE SOLAR HEATING AND COOLING APPLICATIONS <\/td>\n<\/tr>\n
945<\/td>\nFIGURE 23(3) – ACTIVE SPACE AND DOMESTIC WATER HEATING SYSTEM
FIGURE 23(3) – ACTIVE SPACE AND DOMESTIC WATER HEATING SYSTEM <\/td>\n<\/tr>\n
946<\/td>\nFIGURE 23(4) – PASSIVE COLLECTION WITH MECHANICAL DISTRIBUTION
FIGURE 23(4) – PASSIVE COLLECTION WITH MECHANICAL DISTRIBUTION <\/td>\n<\/tr>\n
948<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
949<\/td>\nPART VI – FUEL GAS
PART VI – FUEL GAS
CHAPTER 24: FUEL GAS
CHAPTER 24: FUEL GAS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION G2401 (101) – GENERAL
SECTION G2401 (101) – GENERAL <\/td>\n<\/tr>\n
950<\/td>\nSECTION G2402 (201) – GENERAL
SECTION G2402 (201) – GENERAL
SECTION G2403 (202) – GENERAL DEFINITIONS
SECTION G2403 (202) – GENERAL DEFINITIONS <\/td>\n<\/tr>\n
951<\/td>\nFIGURE G2403(1) ANODELESS RISERS
FIGURE G2403(1) ANODELESS RISERS <\/td>\n<\/tr>\n
952<\/td>\nFIGURE G2403(2) – BARAMETRIC DRAFT REGULATOR
FIGURE G2403(2) – BARAMETRIC DRAFT REGULATOR <\/td>\n<\/tr>\n
953<\/td>\nFIGURE G2403(3) – LABEL FOR LOW-PRESSURE BOILER
FIGURE G2403(3) – LABEL FOR LOW-PRESSURE BOILER <\/td>\n<\/tr>\n
954<\/td>\nFIGURE G2403(4) – FACTORY-BUILT CHIMNEYS
FIGURE G2403(4) – FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n
955<\/td>\nFIGURE G2403(5) – AIR COOLED FACTORY-BUILT CHIMNEY SECTION
FIGURE G2403(5) – AIR COOLED FACTORY-BUILT CHIMNEY SECTION <\/td>\n<\/tr>\n
957<\/td>\nFIGURE G2403(6) – DIRECT-VENT APPLIANCE
FIGURE G2403(6) – DIRECT-VENT APPLIANCE
FIGURE G2403(7) – DIRECT-VENT APPLIANCE
FIGURE G2403(7) – DIRECT-VENT APPLIANCE <\/td>\n<\/tr>\n
958<\/td>\nFIGURE G2403(8) – DRAFT HOOD EQUIPPED APPLIANCE
FIGURE G2403(8) – DRAFT HOOD EQUIPPED APPLIANCE <\/td>\n<\/tr>\n
960<\/td>\nFIGURE G2403(9) – CHIMNEY FLUE LINER SYSTEM FOR GAS APPLIANCE
FIGURE G2403(9) – CHIMNEY FLUE LINER SYSTEM FOR GAS APPLIANCE <\/td>\n<\/tr>\n
961<\/td>\nFIGURE G2403(10) – GAS CONVENIENCE OUTLET
FIGURE G2403(10) – GAS CONVENIENCE OUTLET <\/td>\n<\/tr>\n
962<\/td>\nFIGURE G2403(11) – GAS CONVENIENCE OUTLET
FIGURE G2403(11) – GAS CONVENIENCE OUTLET <\/td>\n<\/tr>\n
963<\/td>\nFIGURE G2403(12) – TYPICAL RESIDENTIAL GAS METER SETTING
FIGURE G2403(12) – TYPICAL RESIDENTIAL GAS METER SETTING <\/td>\n<\/tr>\n
964<\/td>\nFIGURE G2403(13) – VENT OFFSET
FIGURE G2403(13) – VENT OFFSET
FIGURE G2403.(14) – OXYGEN DEPLETION SAFETY SHUTOFF
FIGURE G2403.(14) – OXYGEN DEPLETION SAFETY SHUTOFF <\/td>\n<\/tr>\n
966<\/td>\nFIGURE G2403(15) – SERVICE REGULATOR
FIGURE G2403(15) – SERVICE REGULATOR <\/td>\n<\/tr>\n
967<\/td>\nFIGURE G2403(16) – UNVENTED ROOM HEATER
FIGURE G2403(16) – UNVENTED ROOM HEATER
FIGURE G2403(17) – TRANSITION FITTINGS
FIGURE G2403(17) – TRANSITION FITTINGS <\/td>\n<\/tr>\n
968<\/td>\nFIGURE G2403(18) – TYPE B VENT
FIGURE G2403(18) – TYPE B VENT <\/td>\n<\/tr>\n
970<\/td>\nSECTION G2404 (301) – GENERAL
SECTION G2404 (301) – GENERAL <\/td>\n<\/tr>\n
972<\/td>\nFIGURE G2404.10 – AUXILIARY DRAIN PAN REQUIRED (WITH OR WITHOUT COOLING COIL)
FIGURE G2404.10 – AUXILIARY DRAIN PAN REQUIRED (WITH OR WITHOUT COOLING COIL) <\/td>\n<\/tr>\n
973<\/td>\nSECTION G2405 (302) – STRUCTURAL SAFETY
SECTION G2405 (302) – STRUCTURAL SAFETY
SECTION G2406 (303) – APPLIANCE LOCATION
SECTION G2406 (303) – APPLIANCE LOCATION <\/td>\n<\/tr>\n
974<\/td>\nFIGURE G2406.2(1) – UNVENTED WALL-MOUNTED ROOM HEATER
FIGURE G2406.2(1) – UNVENTED WALL-MOUNTED ROOM HEATER <\/td>\n<\/tr>\n
975<\/td>\nFIGURE G2406.2(2) – APPLIANCE ENCLOSURE
FIGURE G2406.2(2) – APPLIANCE ENCLOSURE
SECTION G2407 (304) – COMBUSTION, VENTILATION AND DILUTION AIR
SECTION G2407 (304) – COMBUSTION, VENTILATION AND DILUTION AIR <\/td>\n<\/tr>\n
976<\/td>\nFIGURE G2407.1(1) – THE CHEMISTRY OF IDEAL COMBUSTION
FIGURE G2407.1(1) – THE CHEMISTRY OF IDEAL COMBUSTION
FIGURE G2407.1(2) – THE CHEMISTRY OF INCOMPLETE COMBUSTION
FIGURE G2407.1(2) – THE CHEMISTRY OF INCOMPLETE COMBUSTION <\/td>\n<\/tr>\n
977<\/td>\nFIGURE G2407.1(3) – COMBUSTION AIR SUPPLY METHODS
FIGURE G2407.1(3) – COMBUSTION AIR SUPPLY METHODS <\/td>\n<\/tr>\n
978<\/td>\nFIGURE G2407.1(4) – DIRECT-VENT APPLIANCE
FIGURE G2407.1(4) – DIRECT-VENT APPLIANCE
FIGURE G2407.1(5) – DIRECT COMBUSTION AIR CONNECTION TO THE OUTDOORS
FIGURE G2407.1(5) – DIRECT COMBUSTION AIR CONNECTION TO THE OUTDOORS <\/td>\n<\/tr>\n
980<\/td>\nFIGURE G2407.4 – DEPLETION OF COMBUSTION AIR
FIGURE G2407.4 – DEPLETION OF COMBUSTION AIR <\/td>\n<\/tr>\n
981<\/td>\nEQUATION 24-1
EQUATION 24-1
EQUATION 24-2
EQUATION 24-2
FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section G2407.5.3)
FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING (see Section G2407.5.3) <\/td>\n<\/tr>\n
982<\/td>\nTABLE G2407.5.2 – CALCULATED VOLUMES
TABLE G2407.5.2 – CALCULATED VOLUMES <\/td>\n<\/tr>\n
984<\/td>\nFIGURE G2407.6.1(1) [304.6(1)] ALL AIR FROM OUTDOOR-INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section G2407.6.1)
FIGURE G2407.6.1(1) [304.6(1)] ALL AIR FROM OUTDOOR-INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section G2407.6.1)
FIGURE G2407.6.1(2) [304.6.1(2)] ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC(see Section G2407.6.1)
FIGURE G2407.6.1(2) [304.6.1(2)] ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC(see Section G2407.6.1) <\/td>\n<\/tr>\n
985<\/td>\nFIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (see Section G2407.6.1)
FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS (see Section G2407.6.1)
FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING,ALL AIR FROM OUTDOORS (see Section G2407.6.2)
FIGURE G2407.6.2 (304.6.2) SINGLE COMBUSTION AIR OPENING,ALL AIR FROM OUTDOORS (see Section G2407.6.2) <\/td>\n<\/tr>\n
987<\/td>\nFIGURE G2407.7.3 ROOM CONFIGURATION USED IN EXAMPLE 2
FIGURE G2407.7.3 ROOM CONFIGURATION USED IN EXAMPLE 2 <\/td>\n<\/tr>\n
988<\/td>\nFIGURE G2407.8(1) MECHANICAL COMBUSTION AIR\/MAKEUP AIR SUPPLY SYSTEM
FIGURE G2407.8(1) MECHANICAL COMBUSTION AIR\/MAKEUP AIR SUPPLY SYSTEM <\/td>\n<\/tr>\n
989<\/td>\nFIGURE G2407.8(2) MECHANICAL COMBUSTION AIR SUPPLY SYSTEM
FIGURE G2407.8(2) MECHANICAL COMBUSTION AIR SUPPLY SYSTEM
FIGURE G2407.8(3) MECHANICAL COMBUSTION AIR\/MAKEUP AIR SUPPLY SYSTEM
FIGURE G2407.8(3) MECHANICAL COMBUSTION AIR\/MAKEUP AIR SUPPLY SYSTEM <\/td>\n<\/tr>\n
990<\/td>\nFIGURE G2407.9 MECHANICALLY SUPPLIED COMBUSTION AIR
FIGURE G2407.9 MECHANICALLY SUPPLIED COMBUSTION AIR <\/td>\n<\/tr>\n
991<\/td>\nFIGURE G2407.9.2 SIMPLIFIED EXAMPLE SCHEMATIC OF INTERLOCKBETWEEN APPLIANCE AND POWER COMBUSTION AIR UNIT(Shown for Illustrative Purpose only)
FIGURE G2407.9.2 SIMPLIFIED EXAMPLE SCHEMATIC OF INTERLOCKBETWEEN APPLIANCE AND POWER COMBUSTION AIR UNIT(Shown for Illustrative Purpose only) <\/td>\n<\/tr>\n
992<\/td>\nFIGURE G2407.10 SIMPLIFIED EXAMPLE SCHEMATIC OF COMBUSTION AIR DAMPER\/APPLIANCE INTERLOCK(Shown for Illustrative Purpose Only)
FIGURE G2407.10 SIMPLIFIED EXAMPLE SCHEMATIC OF COMBUSTION AIR DAMPER\/APPLIANCE INTERLOCK(Shown for Illustrative Purpose Only) <\/td>\n<\/tr>\n
993<\/td>\nFIGURE G2407.11 COMMON DUCT PROHIBITED
FIGURE G2407.11 COMMON DUCT PROHIBITED <\/td>\n<\/tr>\n
994<\/td>\nSECTION G2408 (305) INSTALLATION
SECTION G2408 (305) INSTALLATION <\/td>\n<\/tr>\n
995<\/td>\nFIGURE G2408.2(1) GAS-FIRED WATER HEATER INSTALLATION IN A GARAGE
FIGURE G2408.2(1) GAS-FIRED WATER HEATER INSTALLATION IN A GARAGE
FIGURE G2408.2(2) SOURCES OF IGNITIONELEVATED IN PRIVATE GARAGE
FIGURE G2408.2(2) SOURCES OF IGNITIONELEVATED IN PRIVATE GARAGE <\/td>\n<\/tr>\n
996<\/td>\nFIGURE G2408.2(3) GARAGE SPACE VS. LIVING SPACE
FIGURE G2408.2(3) GARAGE SPACE VS. LIVING SPACE
FIGURE G2408.2(4) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE G2408.2(4) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY <\/td>\n<\/tr>\n
997<\/td>\nFIGURE G2408.2(5) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE G2408.2(5) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE G2048l.2(6) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE G2048l.2(6) EXAMPLE OF FLAMMABLE VAPOR IGNITION RESISTANT WATER HEATER TECHNOLOGY
FIGURE G2408.2.1 ELEVATION OF APPLIANCES NOT REQUIRED
FIGURE G2408.2.1 ELEVATION OF APPLIANCES NOT REQUIRED <\/td>\n<\/tr>\n
998<\/td>\nFIGURE G2408.3(1) SUSPENDED UNIT HEATER
FIGURE G2408.3(1) SUSPENDED UNIT HEATER
FIGURE G2408.3(2) PROTECTED BY WALLS
FIGURE G2408.3(2) PROTECTED BY WALLS <\/td>\n<\/tr>\n
999<\/td>\nFIGURE G2408.3(3) PROTECTED BY GUARDS
FIGURE G2408.3(3) PROTECTED BY GUARDS
FIGURE G2408.3(4) PROTECTED BY A PLATFORM
FIGURE G2408.3(4) PROTECTED BY A PLATFORM <\/td>\n<\/tr>\n
1000<\/td>\nFIGURE G2408.3(5) PROTECTED BY A CURB STOP
FIGURE G2408.3(5) PROTECTED BY A CURB STOP
SECTION G2409 (308) CLEARANCE REDUCTION
SECTION G2409 (308) CLEARANCE REDUCTION <\/td>\n<\/tr>\n
1001<\/td>\nFIGURE G2409.1 CLEARANCE TO COMBUSTIBLES\u2014EXAMPLES OF HOW TO MEASURE
FIGURE G2409.1 CLEARANCE TO COMBUSTIBLES\u2014EXAMPLES OF HOW TO MEASURE <\/td>\n<\/tr>\n
1003<\/td>\nTABLE G2409.2 (308.2)a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
TABLE G2409.2 (308.2)a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION <\/td>\n<\/tr>\n
1004<\/td>\nFIGURE G2409.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTIONS
FIGURE G2409.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTIONS
FIGURE G2409.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE G2409.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM <\/td>\n<\/tr>\n
1005<\/td>\nFIGURE G2409.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
FIGURE G2409.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
FIGURE G2409.2 REDUCED CLEARANCE TO COMBUSTIBLES
FIGURE G2409.2 REDUCED CLEARANCE TO COMBUSTIBLES <\/td>\n<\/tr>\n
1007<\/td>\nSECTION G2410 (309) ELECTRICAL
SECTION G2410 (309) ELECTRICAL
SECTION G2411 (310) ELECTRICAL BONDING
SECTION G2411 (310) ELECTRICAL BONDING <\/td>\n<\/tr>\n
1008<\/td>\nFIGURE G2411.1 GAS PIPE BONDING BY APPLIANCE BRANCH CIRCUIT
FIGURE G2411.1 GAS PIPE BONDING BY APPLIANCE BRANCH CIRCUIT <\/td>\n<\/tr>\n
1009<\/td>\nFIGURE G2411.1(1) CSST BONDING
FIGURE G2411.1(1) CSST BONDING <\/td>\n<\/tr>\n
1010<\/td>\nFIGURE G2411.1(2) ALTERNATIVE LOCATION FOR BONDING CLAMP
FIGURE G2411.1(2) ALTERNATIVE LOCATION FOR BONDING CLAMP
SECTION G2412 (401) GENERAL
SECTION G2412 (401) GENERAL <\/td>\n<\/tr>\n
1011<\/td>\nFIGURE G2412.1(1) SCOPE OF CODES
FIGURE G2412.1(1) SCOPE OF CODES <\/td>\n<\/tr>\n
1012<\/td>\nFIGURE G2412.1(2) TYPICAL POINT OF DELIVERY FOR NATURAL GAS SERVICE
FIGURE G2412.1(2) TYPICAL POINT OF DELIVERY FOR NATURAL GAS SERVICE <\/td>\n<\/tr>\n
1013<\/td>\nSECTION G2413 (402) PIPE SIZING
SECTION G2413 (402) PIPE SIZING <\/td>\n<\/tr>\n
1014<\/td>\nTABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES
TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES <\/td>\n<\/tr>\n
1015<\/td>\nEQUATION 24-3
EQUATION 24-3
EQUATION 24-4
EQUATION 24-4 <\/td>\n<\/tr>\n
1016<\/td>\nTABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
FIGURE G2413.4 GAS PIPING LAYOUT
FIGURE G2413.4 GAS PIPING LAYOUT <\/td>\n<\/tr>\n
1017<\/td>\nTABLE G2413.4(1) [402.4(2)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(1) [402.4(2)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1018<\/td>\nTABLE G2413.4(2) [402.4(3)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(2) [402.4(3)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1019<\/td>\nTABLE G2413.4(3) [402.4(7)] SEMIRIGID COPPER TUBING
TABLE G2413.4(3) [402.4(7)] SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
1020<\/td>\nTABLE G2413.4(4) [402.4(10)] SEMIRIGID COPPER TUBING
TABLE G2413.4(4) [402.4(10)] SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
1021<\/td>\nTABLE G2413.4(5) [402.4(13)] CORRUGATED STAINLESS STEEL TUBING (CSST)
TABLE G2413.4(5) [402.4(13)] CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
1022<\/td>\nTABLE G2413.4(6) [402.4(16)] CORRUGATED STAINLESS STEEL TUBING (CSST)
TABLE G2413.4(6) [402.4(16)] CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
1023<\/td>\nTABLE G2413.4(7) [402.4(19)] POLYETHYLENE PLASTIC PIPE
TABLE G2413.4(7) [402.4(19)] POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
1024<\/td>\nTABLE G2413.4(8) [402.4(20)] POLYETHYLENE PLASTIC PIPE
TABLE G2413.4(8) [402.4(20)] POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
1025<\/td>\nTABLE G2413.4(9) [402.4(23)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(9) [402.4(23)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1026<\/td>\nTABLE G2413.4(10) [402.4(24)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(10) [402.4(24)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1027<\/td>\nTABLE G2413.4(11) [402.4(25)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(11) [402.4(25)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1028<\/td>\nTABLE G2413.4(12) [402.4(26)] SCHEDULE 40 METALLIC PIPE
TABLE G2413.4(12) [402.4(26)] SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
1029<\/td>\nTABLE G2413.4(13) [402.4(27)] SEMIRIGID COPPER TUBING
TABLE G2413.4(13) [402.4(27)] SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
1030<\/td>\nTABLE G2413.4(14) [402.4(28)] SEMIRIGID COPPER TUBING
TABLE G2413.4(14) [402.4(28)] SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
1031<\/td>\nTABLE G2413.4(15) [402.4(29)] SEMIRIGID COPPER TUBING
TABLE G2413.4(15) [402.4(29)] SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
1032<\/td>\nTABLE G2413.4(16) [402.4(30)] CORRUGATED STAINLESS STEEL TUBING (CSST)
TABLE G2413.4(16) [402.4(30)] CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
1033<\/td>\nTABLE G2413.4(17) [402.4(31)] CORRUGATED STAINLESS STEEL TUBING (CSST)
TABLE G2413.4(17) [402.4(31)] CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
1034<\/td>\nTABLE G2413.4(18) [402.4(32)] CORRUGATED STAINLESS STEEL TUBING (CSST)
TABLE G2413.4(18) [402.4(32)] CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
1035<\/td>\nTABLE G2413.4(19) [402.4(33)] POLYETHYLENE PLASTIC PIPE
TABLE G2413.4(19) [402.4(33)] POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
1036<\/td>\nTABLE G2413.4(20) [402.4(34)] POLYETHYLENE PLASTIC PIPE
TABLE G2413.4(20) [402.4(34)] POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
1037<\/td>\nTABLE G2413.4(21) [402.4(35)] POLYETHYLENE PLASTIC TUBING
TABLE G2413.4(21) [402.4(35)] POLYETHYLENE PLASTIC TUBING <\/td>\n<\/tr>\n
1038<\/td>\nFIGURE G2413.4.1 STEEL PIPE BRANCH SYSTEM FOR ROOF TOP UNITS
FIGURE G2413.4.1 STEEL PIPE BRANCH SYSTEM FOR ROOF TOP UNITS <\/td>\n<\/tr>\n
1039<\/td>\nFIGURE G2413.4.2(1) BRANCH PIPING SYSTEM WITH SCHEDULE 40 STEEL PIPE TUNKLINE AND CSST BRANCHES
FIGURE G2413.4.2(1) BRANCH PIPING SYSTEM WITH SCHEDULE 40 STEEL PIPE TUNKLINE AND CSST BRANCHES <\/td>\n<\/tr>\n
1040<\/td>\nFIGURE G2413.4.2(2) SINGLE PRESSURE CSST MANIFOLD SYSTEM
FIGURE G2413.4.2(2) SINGLE PRESSURE CSST MANIFOLD SYSTEM <\/td>\n<\/tr>\n
1041<\/td>\nFIGURE G2413.4.3(1) HYBRID PRESSURE BRANCH SYSTEM FOR ROOF TOP UNITS
FIGURE G2413.4.3(1) HYBRID PRESSURE BRANCH SYSTEM FOR ROOF TOP UNITS <\/td>\n<\/tr>\n
1042<\/td>\nFIGURE G2413.4.3(2) HYBRID PRESSURE PARALLEL DISTRIBUTION SYSTEM
FIGURE G2413.4.3(2) HYBRID PRESSURE PARALLEL DISTRIBUTION SYSTEM <\/td>\n<\/tr>\n
1044<\/td>\nSECTION G2414 (403) PIPING MATERIALS
SECTION G2414 (403) PIPING MATERIALS
FIGURE G2414.5 PLASTIC-SHEATHED COPPER TUBING
FIGURE G2414.5 PLASTIC-SHEATHED COPPER TUBING <\/td>\n<\/tr>\n
1045<\/td>\nFIGURE G2414.5.3(1) CSST AND SYSTEM COMPONENTS
FIGURE G2414.5.3(1) CSST AND SYSTEM COMPONENTS
FIGURE G2414.5.3(2) CSST FITTING
FIGURE G2414.5.3(2) CSST FITTING
FIGURE G2414.5.3(3) CSST FITTING
FIGURE G2414.5.3(3) CSST FITTING <\/td>\n<\/tr>\n
1046<\/td>\nFIGURE G2414.5.3(4) CSST FITTING
FIGURE G2414.5.3(4) CSST FITTING
FIGURE G2414.5.3(5) MULTIPORT MANIFOLD INSTALLATION USING CSST
FIGURE G2414.5.3(5) MULTIPORT MANIFOLD INSTALLATION USING CSST
FIGURE G2414.5.3(6) TOP PLATE TUBING PROTECTION SHIELD
FIGURE G2414.5.3(6) TOP PLATE TUBING PROTECTION SHIELD <\/td>\n<\/tr>\n
1047<\/td>\nFIGURE G2414.5.3(7) LOW-PRESSURE GAS PIPING SYSTEM USING CSST
FIGURE G2414.5.3(7) LOW-PRESSURE GAS PIPING SYSTEM USING CSST
FIGURE G2414.5.3(8) MEDIUM-PRESSURE GAS PIPING SYSTEM USING CSST
FIGURE G2414.5.3(8) MEDIUM-PRESSURE GAS PIPING SYSTEM USING CSST <\/td>\n<\/tr>\n
1048<\/td>\nFIGURE G2414.5.3(9) CSST MANUFACTURED FOR UNDERGROUND INSTALLATION
FIGURE G2414.5.3(9) CSST MANUFACTURED FOR UNDERGROUND INSTALLATION
FIGURE G2414.5.3(10) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTIONS
FIGURE G2414.5.3(10) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTIONS <\/td>\n<\/tr>\n
1049<\/td>\nFIGURE G2414.5.3(11) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTION
FIGURE G2414.5.3(11) EXCERPT FROM CSST MANUFACTURER’S INSTALLATION INSTRUCTION
FIGURE G2414.5.3(12) MANIFOLD FOR 2 PSI PARALLEL DISTRIBUTION SYSTEM
FIGURE G2414.5.3(12) MANIFOLD FOR 2 PSI PARALLEL DISTRIBUTION SYSTEM
FIGURE G2414.5.3(13) \u201cSTUB-OUT\u201d\u009d TERMINATION TRANSITION FITTING
FIGURE G2414.5.3(13) \u201cSTUB-OUT\u201d\u009d TERMINATION TRANSITION FITTING
FIGURE G2414.5.3(14) \u201cVALVE BOX\u201d\u009d TERMINATION TRANSITION FITTING
FIGURE G2414.5.3(14) \u201cVALVE BOX\u201d\u009d TERMINATION TRANSITION FITTING
FIGURE G2414.5.3(15) TERMINATION TRANSITION FITTING
FIGURE G2414.5.3(15) TERMINATION TRANSITION FITTING <\/td>\n<\/tr>\n
1050<\/td>\nFIGURE G2414.6.1(1) SERVICE HEAD ADAPTERS
FIGURE G2414.6.1(1) SERVICE HEAD ADAPTERS <\/td>\n<\/tr>\n
1051<\/td>\nFIGURE G2414.6.1(2) SERVICE HEAD ADAPTERS
FIGURE G2414.6.1(2) SERVICE HEAD ADAPTERS
FIGURE G2414.6.1(3) FLEXIBLE ANODELESS RISER
FIGURE G2414.6.1(3) FLEXIBLE ANODELESS RISER <\/td>\n<\/tr>\n
1052<\/td>\nFIGURE G2414.9 (403.9) TAPERED THREAD COUPLING IN CONNECTION TO FURNACE
FIGURE G2414.9 (403.9) TAPERED THREAD COUPLING IN CONNECTION TO FURNACE <\/td>\n<\/tr>\n
1053<\/td>\nTABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE
TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE <\/td>\n<\/tr>\n
1054<\/td>\nFIGURE G2414.10.2 PRESS-CONNECT COPPER FITTING
FIGURE G2414.10.2 PRESS-CONNECT COPPER FITTING <\/td>\n<\/tr>\n
1055<\/td>\nSECTION G2415 (404) PIPING SYSTEM INSTALLATION
SECTION G2415 (404) PIPING SYSTEM INSTALLATION <\/td>\n<\/tr>\n
1056<\/td>\nFIGURE G2414.11(1) MECHANICAL JOINTS
FIGURE G2414.11(1) MECHANICAL JOINTS
FIGURE G2414.11(2) MECHANICAL JOINT
FIGURE G2414.11(2) MECHANICAL JOINT <\/td>\n<\/tr>\n
1057<\/td>\nFIGURE G2414.11(3) PLASTIC PIPE TRANSITION FITTING
FIGURE G2414.11(3) PLASTIC PIPE TRANSITION FITTING
FIGURE G2414.11(4) PLASTIC PIPE TRANSITION FITTING
FIGURE G2414.11(4) PLASTIC PIPE TRANSITION FITTING <\/td>\n<\/tr>\n
1058<\/td>\nFIGURE G2415.1 PROHIBITED TOWNHOUSE INSTALLATION
FIGURE G2415.1 PROHIBITED TOWNHOUSE INSTALLATION <\/td>\n<\/tr>\n
1059<\/td>\nFIGURE G2415.4 ABOVE GRADE ENTRANCE\/EXIT
FIGURE G2415.4 ABOVE GRADE ENTRANCE\/EXIT <\/td>\n<\/tr>\n
1060<\/td>\nFIGURE G2415.5 PIPE PROTECTION
FIGURE G2415.5 PIPE PROTECTION <\/td>\n<\/tr>\n
1061<\/td>\nFIGURE G2415.6 PIPING IN SOLID FLOORS
FIGURE G2415.6 PIPING IN SOLID FLOORS <\/td>\n<\/tr>\n
1062<\/td>\nFIGURE G2415.6.2 PIPE UNDER SLAB BETWEEN INTERIOR POINTS
FIGURE G2415.6.2 PIPE UNDER SLAB BETWEEN INTERIOR POINTS <\/td>\n<\/tr>\n
1063<\/td>\nFIGURE G2415.8 LP-GAS PIPING ISOLATION
FIGURE G2415.8 LP-GAS PIPING ISOLATION <\/td>\n<\/tr>\n
1064<\/td>\nFIGURE G2415.10 MINIMUM BURIAL DEPTH
FIGURE G2415.10 MINIMUM BURIAL DEPTH <\/td>\n<\/tr>\n
1065<\/td>\nFIGURE G2415.12.1 GAS PIPING IN CONDUIT UNDERGROUND BENEATH BUILDING
FIGURE G2415.12.1 GAS PIPING IN CONDUIT UNDERGROUND BENEATH BUILDING <\/td>\n<\/tr>\n
1066<\/td>\nFIGURE G2415.15.1 PIPING UNDER SLABS
FIGURE G2415.15.1 PIPING UNDER SLABS <\/td>\n<\/tr>\n
1067<\/td>\nSECTION G2416 (405) – PIPING BENDS AND CHANGES IN DIRECTION
SECTION G2416 (405) – PIPING BENDS AND CHANGES IN DIRECTION <\/td>\n<\/tr>\n
1068<\/td>\nSECTION G2417 (406) – INSPECTION, TESTING AND PURGI
SECTION G2417 (406) – INSPECTION, TESTING AND PURGI <\/td>\n<\/tr>\n
1069<\/td>\nFIGURE G2417.1.4 PIPING ISOLATION ARRANGEMENT FOR TESTING
FIGURE G2417.1.4 PIPING ISOLATION ARRANGEMENT FOR TESTING <\/td>\n<\/tr>\n
1070<\/td>\nFIGURE G2417.3.3 MANUFACTURER’S WARNING REGARDING PRESSURE TESTING OF GAS PIPING
FIGURE G2417.3.3 MANUFACTURER’S WARNING REGARDING PRESSURE TESTING OF GAS PIPING <\/td>\n<\/tr>\n
1071<\/td>\nFIGURE 2417.4(1) TYPICAL TEST SET-UP FOR AIR PRESSURE TESTING
FIGURE 2417.4(1) TYPICAL TEST SET-UP FOR AIR PRESSURE TESTING
FIGURE 2417.4(2) ELECTRONIC PRESSURE GAUGE
FIGURE 2417.4(2) ELECTRONIC PRESSURE GAUGE <\/td>\n<\/tr>\n
1072<\/td>\nFIGURE 2417.4(3) LEAK DETECTOR INSTRUMENT
FIGURE 2417.4(3) LEAK DETECTOR INSTRUMENT
FIGURE 2417.4(4) ELECTRONIC LEAK DETECTOR INSTRUMENT
FIGURE 2417.4(4) ELECTRONIC LEAK DETECTOR INSTRUMENT <\/td>\n<\/tr>\n
1074<\/td>\nSECTION G2418 (407) – PIPING SUPPORT
SECTION G2418 (407) – PIPING SUPPORT <\/td>\n<\/tr>\n
1075<\/td>\nSECTION G2419 (408) – DRIPS AND SLOPED PIPING
SECTION G2419 (408) – DRIPS AND SLOPED PIPING <\/td>\n<\/tr>\n
1076<\/td>\nFIGURE G2419.4(1) SEDIMENT TRAP
FIGURE G2419.4(1) SEDIMENT TRAP
FIGURE G2419.4(2) RELATIVELY INEFFECTIVE SEDIMENT TRAP CONFIGURATION
FIGURE G2419.4(2) RELATIVELY INEFFECTIVE SEDIMENT TRAP CONFIGURATION <\/td>\n<\/tr>\n
1077<\/td>\nSECTION G2420 (409) GAS SHUTOFF VALVES
SECTION G2420 (409) GAS SHUTOFF VALVES
TABLE G2420.1.1 MANUAL GAS VALVE STANDARDS
TABLE G2420.1.1 MANUAL GAS VALVE STANDARDS
FIGURE G2420.1.1(1) TYPICAL BALL-TYPE GAS SHUTOFF VALVE
FIGURE G2420.1.1(1) TYPICAL BALL-TYPE GAS SHUTOFF VALVE
FIGURE G2420.1.1(2) BALL-TYPE GAS SHUTOFF VALVE DESIGNED TO MATE WITH A CONNECTOR
FIGURE G2420.1.1(2) BALL-TYPE GAS SHUTOFF VALVE DESIGNED TO MATE WITH A CONNECTOR <\/td>\n<\/tr>\n
1079<\/td>\nFIGURE G2420.5.1 SHUTOFF VALVE IN CONTROL COMPARTMENT OF GAS FIREPLACE
FIGURE G2420.5.1 SHUTOFF VALVE IN CONTROL COMPARTMENT OF GAS FIREPLACE <\/td>\n<\/tr>\n
1080<\/td>\nSECTION G2421 (410) – FLOW CONTROLS
SECTION G2421 (410) – FLOW CONTROLS
FIGURE G2421.1(1) – GAS PRESSURE REGULATOR
FIGURE G2421.1(1) – GAS PRESSURE REGULATOR <\/td>\n<\/tr>\n
1081<\/td>\nFIGURE G2421.1(2) – SERVICE REGULATOR
FIGURE G2421.1(2) – SERVICE REGULATOR
FIGURE G2421.1(3) – GAS PRESSURE REGULATOR
FIGURE G2421.1(3) – GAS PRESSURE REGULATOR <\/td>\n<\/tr>\n
1082<\/td>\nFIGURE G2421.1(4) – SYSTEM PRESSURES
FIGURE G2421.1(4) – SYSTEM PRESSURES <\/td>\n<\/tr>\n
1083<\/td>\nFIGURE G2421.2(1) – SYSTEM PRESSURES
FIGURE G2421.2(1) – SYSTEM PRESSURES
FIGURE G2421.2(2) – PRESSURE REGULATOR\/OVERPRESSURE PROTECTION DEVICE ASSEMBLIES
FIGURE G2421.2(2) – PRESSURE REGULATOR\/OVERPRESSURE PROTECTION DEVICE ASSEMBLIES <\/td>\n<\/tr>\n
1084<\/td>\nFIGURE G2421.3(1 ) – REGULATOR WITH VENT PROTECTION
FIGURE G2421.3(1 ) – REGULATOR WITH VENT PROTECTION
FIGURE G2421.3(2) – PRESSURE REGULATOR WITH VENT-LIMITING DEVICE
FIGURE G2421.3(2) – PRESSURE REGULATOR WITH VENT-LIMITING DEVICE
SECTION G2422 (411) – APPLIANCE CONNECTIONS
SECTION G2422 (411) – APPLIANCE CONNECTIONS <\/td>\n<\/tr>\n
1085<\/td>\nFIGURE G2422.1(1) PIPING SYSTEM SIZING AND APPLIANCE CONNECTION AND CONNECTOR SIZING
FIGURE G2422.1(1) PIPING SYSTEM SIZING AND APPLIANCE CONNECTION AND CONNECTOR SIZING
FIGURE G2422.1(2) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS
FIGURE G2422.1(2) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS <\/td>\n<\/tr>\n
1086<\/td>\nFIGURE G2422.1(3) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS
FIGURE G2422.1(3) QUICK-DISCONNECT DEVICE FOR USE WITH COMMERCIAL APPLIANCE CONNECTORS
FIGURE G2422.1(4) CSST DIRECTLY CONNECTED TO NONMOVABLE APPLIANCE
FIGURE G2422.1(4) CSST DIRECTLY CONNECTED TO NONMOVABLE APPLIANCE <\/td>\n<\/tr>\n
1087<\/td>\nFIGURE G2422.1(5) CSST TERMINATED TO APPLIANCE LOCATION
FIGURE G2422.1(5) CSST TERMINATED TO APPLIANCE LOCATION
FIGURE G2422.1(6) SEMI-RIGID (FLEXIBLE) APPLIANCE CONNECTOR
FIGURE G2422.1(6) SEMI-RIGID (FLEXIBLE) APPLIANCE CONNECTOR
FIGURE G2422.1(7) OUTDOOR MOBILE HOME CONNECTOR
FIGURE G2422.1(7) OUTDOOR MOBILE HOME CONNECTOR <\/td>\n<\/tr>\n
1089<\/td>\nFIGURE G2422.1.2.1(1) APPLIANCE FUEL CONNECTOR
FIGURE G2422.1.2.1(1) APPLIANCE FUEL CONNECTOR <\/td>\n<\/tr>\n
1090<\/td>\nFIGURE G2422.1.2.1(2) APPLIANCE FUEL CONNECTO
FIGURE G2422.1.2.1(2) APPLIANCE FUEL CONNECTO
FIGURE G2422.1.2.3 CONNECTOR PIPING DOWNSTREAM OF SHUTOFF VALVE
FIGURE G2422.1.2.3 CONNECTOR PIPING DOWNSTREAM OF SHUTOFF VALVE <\/td>\n<\/tr>\n
1091<\/td>\nSECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS
SECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS
SECTION G2424 (415) PIPING SUPPORT INTERVALS
SECTION G2424 (415) PIPING SUPPORT INTERVALS
TABLE G2424.1 SUPPORT OF PIPING
TABLE G2424.1 SUPPORT OF PIPING <\/td>\n<\/tr>\n
1092<\/td>\nFIGURE G2422.2(1) EXAMPLE OF ONE MANUFACTURER’S INSTALLATION INSTRUCTIONS
FIGURE G2422.2(1) EXAMPLE OF ONE MANUFACTURER’S INSTALLATION INSTRUCTIONS
FIGURE G2422.2(2) END VIEW OF FIGURE G2422.2(1)
FIGURE G2422.2(2) END VIEW OF FIGURE G2422.2(1) <\/td>\n<\/tr>\n
1093<\/td>\nSECTION G2425 (501) – GENERAL
SECTION G2425 (501) – GENERAL <\/td>\n<\/tr>\n
1094<\/td>\nFIGURE G2425.6 VENT DESIGNED FOR CATEGORY III AND IVPOSITIVE PRESSURE) APPLICATIONS
FIGURE G2425.6 VENT DESIGNED FOR CATEGORY III AND IVPOSITIVE PRESSURE) APPLICATIONS <\/td>\n<\/tr>\n
1096<\/td>\nFIGURE G2425.13(1) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.13(1) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.13(2) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.13(2) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.13(3) MASONRY CHIMNEY RELINING BY INSTALLATION OF TYPE B VENT SYSTEM
FIGURE G2425.13(3) MASONRY CHIMNEY RELINING BY INSTALLATION OF TYPE B VENT SYSTEM <\/td>\n<\/tr>\n
1097<\/td>\nFIGURE G2425.13(4) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.13(4) MASONRY CHIMNEY RELINING SYSTEM
FIGURE G2425.14 SPECIAL VENT SYSTEM FOR CATEGORYII, III AND IV APPLIANCES
FIGURE G2425.14 SPECIAL VENT SYSTEM FOR CATEGORYII, III AND IV APPLIANCES <\/td>\n<\/tr>\n
1098<\/td>\nFIGURE G2425.15 APPLIANCE REPLACEMENTS AFFECTING EXISTING APPLIANCES
FIGURE G2425.15 APPLIANCE REPLACEMENTS AFFECTING EXISTING APPLIANCES <\/td>\n<\/tr>\n
1099<\/td>\nSECTION G2426 (502) – VENTS
SECTION G2426 (502) – VENTS <\/td>\n<\/tr>\n
1100<\/td>\nFIGURE G2426.1(1) CATEGORY I FAN-ASSISTED FURNA
FIGURE G2426.1(1) CATEGORY I FAN-ASSISTED FURNA
FIGURE G2426.1(2) CATEGORY IV APPLIANCE (FURNACE
FIGURE G2426.1(2) CATEGORY IV APPLIANCE (FURNACE <\/td>\n<\/tr>\n
1101<\/td>\nFIGURE G2426.1(3) TYPE B GAS VENT SERVING TWO CATEGORY I APPLIANCES
FIGURE G2426.1(3) TYPE B GAS VENT SERVING TWO CATEGORY I APPLIANCES
FIGURE G2426.1(4) TYPE B VENT SECTIONS WITH AIR SPACE BETWEEN PIPE WALLS
FIGURE G2426.1(4) TYPE B VENT SECTIONS WITH AIR SPACE BETWEEN PIPE WALLS <\/td>\n<\/tr>\n
1102<\/td>\nSECTION G2427 (503) VENTING OF APPLIANCES
SECTION G2427 (503) VENTING OF APPLIANCES <\/td>\n<\/tr>\n
1103<\/td>\nFIGURE G2426.7 PLAN VIEW OF STUD WALL
FIGURE G2426.7 PLAN VIEW OF STUD WALL <\/td>\n<\/tr>\n
1104<\/td>\nFIGURE G2427.2.1(1) DIRECT-VENT APPLIANCE
FIGURE G2427.2.1(1) DIRECT-VENT APPLIANCE
FIGURE G2427.2.1(2) DIRECT-VENT(SEPARATED COMBUSTION) UNIT HEATERS
FIGURE G2427.2.1(2) DIRECT-VENT(SEPARATED COMBUSTION) UNIT HEATERS
FIGURE G2427.2.1(3) EXAMPLE OF MANUFACTURER’S DETAIL FORDIRECT-VENT APPLIANCE CONCENTRIC VENT-AIR INTAKE TERMINAL
FIGURE G2427.2.1(3) EXAMPLE OF MANUFACTURER’S DETAIL FORDIRECT-VENT APPLIANCE CONCENTRIC VENT-AIR INTAKE TERMINAL
FIGURE G2427.2.1(4) DIRECT-VENT APPLIANCES
FIGURE G2427.2.1(4) DIRECT-VENT APPLIANCES <\/td>\n<\/tr>\n
1105<\/td>\nFIGURE G2427.2.1(5) GRAVITY DIRECT-VENT WATER HEATER
FIGURE G2427.2.1(5) GRAVITY DIRECT-VENT WATER HEATER
FIGURE G2427.2.1(6) DIRECT-VENT SYSTEM COMPONENTS
FIGURE G2427.2.1(6) DIRECT-VENT SYSTEM COMPONENTS
FIGURE G2427.2.2(1) HOT WATER BOILER WITH INTEGRAL VENT FOR OUTDOOR INSTALLATION
FIGURE G2427.2.2(1) HOT WATER BOILER WITH INTEGRAL VENT FOR OUTDOOR INSTALLATION <\/td>\n<\/tr>\n
1106<\/td>\nFIGURE G2427.2.2(2) OUTDOOR DUCT FURNACE WITH INTEGRAL POWER VENTING
FIGURE G2427.2.2(2) OUTDOOR DUCT FURNACE WITH INTEGRAL POWER VENTING
FIGURE G2427.2.2(3) ROOFTOP HVAC UNIT WITH INTEGRAL POWER VENT
FIGURE G2427.2.2(3) ROOFTOP HVAC UNIT WITH INTEGRAL POWER VENT <\/td>\n<\/tr>\n
1107<\/td>\nFIGURE G2427.3.3(1) VERTICAL DRAFT INDUCER
FIGURE G2427.3.3(1) VERTICAL DRAFT INDUCER
FIGURE G2427.3.3(2) HORIZONTAL POWER EXHAUSTER
FIGURE G2427.3.3(2) HORIZONTAL POWER EXHAUSTER <\/td>\n<\/tr>\n
1108<\/td>\nFIGURE G2427.3.3(3) HORIZONTAL POWER EXHAUSTERS
FIGURE G2427.3.3(3) HORIZONTAL POWER EXHAUSTERS
FIGURE G2427.3.3(4) POWER EXHAUSTER OUTDOOR TERMINAL-TYPE UNIT
FIGURE G2427.3.3(4) POWER EXHAUSTER OUTDOOR TERMINAL-TYPE UNIT <\/td>\n<\/tr>\n
1109<\/td>\nFIGURE G2427.3.3(5) EXHAUSTER AND CONTROL PACKAGE
FIGURE G2427.3.3(5) EXHAUSTER AND CONTROL PACKAGE
FIGURE G2427.3.3(6) TYPICAL POWER EXHAUSTER
FIGURE G2427.3.3(6) TYPICAL POWER EXHAUSTER <\/td>\n<\/tr>\n
1110<\/td>\nFIGURE G2427.3.3(7) TYPICAL EXHAUSTER APPLICATIONS
FIGURE G2427.3.3(7) TYPICAL EXHAUSTER APPLICATIONS
FIGURE G2427.3.3(8) DRAFT INDUCER
FIGURE G2427.3.3(8) DRAFT INDUCER
FIGURE G2427.3.3(9) DRAFT INDUCER
FIGURE G2427.3.3(9) DRAFT INDUCER <\/td>\n<\/tr>\n
1111<\/td>\nFIGURE G2427.3.3(10) POWER VENTED WATER HEATER
FIGURE G2427.3.3(10) POWER VENTED WATER HEATER
FIGURE G2427.3.3(11) SIMPLIFIED SAMPLE INTERLOCK DIAGRAM FOR APPLIANCE S
FIGURE G2427.3.3(11) SIMPLIFIED SAMPLE INTERLOCK DIAGRAM FOR APPLIANCE S <\/td>\n<\/tr>\n
1112<\/td>\nFIGURE G2427.3.5 VENTS THROUGH AIR PLENUMS
FIGURE G2427.3.5 VENTS THROUGH AIR PLENUMS <\/td>\n<\/tr>\n
1113<\/td>\nTABLE G2427.4 TYPE OF VENTING SYSTEM TO BE USED
TABLE G2427.4 TYPE OF VENTING SYSTEM TO BE USED
FIGURE G2427.4 DETERMINING VENT HEIGHT
FIGURE G2427.4 DETERMINING VENT HEIGHT <\/td>\n<\/tr>\n
1115<\/td>\nFIGURE G2427.5.3 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES
FIGURE G2427.5.3 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES <\/td>\n<\/tr>\n
1116<\/td>\nFIGURE G2427.5.3(1) LOW-HEAT CHIMNEY TERMINATIONS
FIGURE G2427.5.3(1) LOW-HEAT CHIMNEY TERMINATIONS <\/td>\n<\/tr>\n
1117<\/td>\nFIGURE G2427.5.3(2) – DECORATIVE SHROUDS
FIGURE G2427.5.3(2) – DECORATIVE SHROUDS
FIGURE G2427.5.5.1(1) CHIMNEY LINING SYSTEM FOR GAS APPLIANCES
FIGURE G2427.5.5.1(1) CHIMNEY LINING SYSTEM FOR GAS APPLIANCES <\/td>\n<\/tr>\n
1118<\/td>\nFIGURE G2427.5.5.1(2) DIRECT-VENT GAS APPLIANCE FOR INSTALLATION IN SOLID FUEL FIREPLACE
FIGURE G2427.5.5.1(2) DIRECT-VENT GAS APPLIANCE FOR INSTALLATION IN SOLID FUEL FIREPLACE <\/td>\n<\/tr>\n
1120<\/td>\nFIGURE G2427.6.3 (503.6.4) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
FIGURE G2427.6.3 (503.6.4) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL <\/td>\n<\/tr>\n
1121<\/td>\nFIGURE G2427.6.3 TOP LOCATION RULES
FIGURE G2427.6.3 TOP LOCATION RULES <\/td>\n<\/tr>\n
1122<\/td>\nFIGURE G2427.6.3.1 DECORATIVE SHROUDS
FIGURE G2427.6.3.1 DECORATIVE SHROUDS <\/td>\n<\/tr>\n
1123<\/td>\nFIGURE G2427.6.6 GAS VENT TERMINATIONS WITH RESPECT TO FORCED AIR INTAKES
FIGURE G2427.6.6 GAS VENT TERMINATIONS WITH RESPECT TO FORCED AIR INTAKES <\/td>\n<\/tr>\n
1125<\/td>\nFIGURE G2427.6.11 FASTENER PENETRATIO
FIGURE G2427.6.11 FASTENER PENETRATIO <\/td>\n<\/tr>\n
1128<\/td>\nFIGURE G2427.8(1) MECHANICAL DRAFT VENTING SYSTEM EXHAUSTER TERMINATIONS
FIGURE G2427.8(1) MECHANICAL DRAFT VENTING SYSTEM EXHAUSTER TERMINATIONS <\/td>\n<\/tr>\n
1129<\/td>\nFIGURE G2427.8(2) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE TERMINAL
FIGURE G2427.8(2) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE TERMINAL
FIGURE G2427.8(3) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE TERMINAL
FIGURE G2427.8(3) EXAMPLE OF MANUFACTURER’S DETAIL FOR DIRECT-VENT APPLIANCE TERMINAL <\/td>\n<\/tr>\n
1130<\/td>\nFIGURE G2427.8(4) DIRECT-VENT HOT WATER BOILER
FIGURE G2427.8(4) DIRECT-VENT HOT WATER BOILER <\/td>\n<\/tr>\n
1131<\/td>\nFIGURE G2427.10.2.2 LISTED BENDABLE DOUBLE-WALL CONNECTOR
FIGURE G2427.10.2.2 LISTED BENDABLE DOUBLE-WALL CONNECTOR
TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES <\/td>\n<\/tr>\n
1133<\/td>\nFIGURE G2427.10.3.4(1) MANIFOLD SIZING
FIGURE G2427.10.3.4(1) MANIFOLD SIZING
FIGURE G2427.10.3.4(2) COMMON VENT OFFSET AND MANIFOLD
FIGURE G2427.10.3.4(2) COMMON VENT OFFSET AND MANIFOLD <\/td>\n<\/tr>\n
1134<\/td>\nFIGURE G2427.10.4.1 OPPOSING OPENINGS IN CHIMNEY
FIGURE G2427.10.4.1 OPPOSING OPENINGS IN CHIMNEY
TABLE G2427.10.5 (503.10.5)a CLEARANCES FOR CONNECTORS
TABLE G2427.10.5 (503.10.5)a CLEARANCES FOR CONNECTORS <\/td>\n<\/tr>\n
1135<\/td>\nFIGURE G2427.10.9 VENT HEIGHT
FIGURE G2427.10.9 VENT HEIGHT <\/td>\n<\/tr>\n
1137<\/td>\nFIGURE G2427.10.14 TYPE B VENT CONNECTOR PENETRATIONS
FIGURE G2427.10.14 TYPE B VENT CONNECTOR PENETRATIONS <\/td>\n<\/tr>\n
1138<\/td>\nFIGURE G2427.12.1 DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE G2427.12.1 DRAFT-HOOD-EQUIPPED APPLIANCE <\/td>\n<\/tr>\n
1140<\/td>\nFIGURE G2427.14 AUTOMATIC VENT DAMPERS
FIGURE G2427.14 AUTOMATIC VENT DAMPERS <\/td>\n<\/tr>\n
1141<\/td>\nSECTION G2428 (504) – SIZING OF CATEGORY I APPLIANC EVENTING SYS
SECTION G2428 (504) – SIZING OF CATEGORY I APPLIANC EVENTING SYS <\/td>\n<\/tr>\n
1142<\/td>\nFIGURE G2428.1(1) COMBUSTION PROCESS FOR NATURAL GAS
FIGURE G2428.1(1) COMBUSTION PROCESS FOR NATURAL GAS
FIGURE G2428.1(2) FUEL GAS COMPOSITION
FIGURE G2428.1(2) FUEL GAS COMPOSITION
FIGURE G2428.1(3) DRAFT-HOOD APPLIANCE COMPARED TO FAN-ASSISTED APPLIANCE
FIGURE G2428.1(3) DRAFT-HOOD APPLIANCE COMPARED TO FAN-ASSISTED APPLIANCE
FIGURE G2428.1(4) ILLUSTRATION OF THE BASIC PRINCIPLE OF FAN-ASSISTED COMBUSTIO
FIGURE G2428.1(4) ILLUSTRATION OF THE BASIC PRINCIPLE OF FAN-ASSISTED COMBUSTIO <\/td>\n<\/tr>\n
1144<\/td>\nFIGURE G2428.1(5) FAN-ASSISTED HOT WATER BOILER
FIGURE G2428.1(5) FAN-ASSISTED HOT WATER BOILER
FIGURE G2428.2(1) EXAMPLE OF INDIVIDUAL VENT DIMENSIONS
FIGURE G2428.2(1) EXAMPLE OF INDIVIDUAL VENT DIMENSIONS <\/td>\n<\/tr>\n
1145<\/td>\nFIGURE G2428.2(2) INDIVIDUAL VENT\u2014LATERAL AND HEIGHT
FIGURE G2428.2(2) INDIVIDUAL VENT\u2014LATERAL AND HEIGHT <\/td>\n<\/tr>\n
1146<\/td>\nFIGURE 2428.2.1 CATEGORY I NATURAL DRAFT HOT WATER BOILER WITH DRAFT HOOD AND AUTOMATIC VENT DAMPER
FIGURE 2428.2.1 CATEGORY I NATURAL DRAFT HOT WATER BOILER WITH DRAFT HOOD AND AUTOMATIC VENT DAMPER <\/td>\n<\/tr>\n
1148<\/td>\nTABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT
TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
1149<\/td>\nTABLE G2428.2(1) [504.2(1)]\u2014continued TYPE B DOUBLE-WALL GAS VENT
TABLE G2428.2(1) [504.2(1)]\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
1150<\/td>\nTABLE G2428.2(2) [504.2(2)]TYPE B DOUBLE-WALL GAS VENT
TABLE G2428.2(2) [504.2(2)]TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
1151<\/td>\nTABLE G2428.2(2) [504.2(2)]\u2014continued TYPE B DOUBLE-WALL GAS VENT
TABLE G2428.2(2) [504.2(2)]\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
1152<\/td>\nFIGURE G2428.2.9(1) MASONRY CHIMNEY COMPARED TO TYPE B VENT
FIGURE G2428.2.9(1) MASONRY CHIMNEY COMPARED TO TYPE B VENT <\/td>\n<\/tr>\n
1155<\/td>\nFIGURE G2428.3(1) COMBINED VENT DIMENSIONS
FIGURE G2428.3(1) COMBINED VENT DIMENSIONS <\/td>\n<\/tr>\n
1157<\/td>\nFIGURE G2428.3(2) FAN AND NAT VENT SIZING EXAMPLE
FIGURE G2428.3(2) FAN AND NAT VENT SIZING EXAMPLE <\/td>\n<\/tr>\n
1159<\/td>\nTABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH
TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH <\/td>\n<\/tr>\n
1160<\/td>\nFIGURE G2428.3.5 COMMON VENT OFFSET IN ATTIC FOR THE PURPOSE OF AVOIDING A STREET-SIDE ROOF PENETRATION
FIGURE G2428.3.5 COMMON VENT OFFSET IN ATTIC FOR THE PURPOSE OF AVOIDING A STREET-SIDE ROOF PENETRATION <\/td>\n<\/tr>\n
1161<\/td>\nFIGURE G2428.3.6(1) OFFSET IN COMMON VENT AND CONNECTORS
FIGURE G2428.3.6(1) OFFSET IN COMMON VENT AND CONNECTORS <\/td>\n<\/tr>\n
1162<\/td>\nFIGURE G2428.3.6(2) TYPE B VENT ADJUSTABLE 45-DEGREE ELBOW FITTING
FIGURE G2428.3.6(2) TYPE B VENT ADJUSTABLE 45-DEGREE ELBOW FITTING
FIGURE G2428.3.6(3) TYPE B VENT ADJUSTABLE 90-DEGREE ELBOW FITTING
FIGURE G2428.3.6(3) TYPE B VENT ADJUSTABLE 90-DEGREE ELBOW FITTING <\/td>\n<\/tr>\n
1163<\/td>\nFIGURE G2428.3.9(1) TYPE B VENT REDUCING TEE
FIGURE G2428.3.9(1) TYPE B VENT REDUCING TEE
FIGURE G2428.3.9(2) TYPE B VENT REDUCING WYE
FIGURE G2428.3.9(2) TYPE B VENT REDUCING WYE
FIGURE G2428.3.9.1 SINGLE-WALL TEES AND WYES PROHIBITED IN TYPE B COMMON VENT SYSTEMS
FIGURE G2428.3.9.1 SINGLE-WALL TEES AND WYES PROHIBITED IN TYPE B COMMON VENT SYSTEMS <\/td>\n<\/tr>\n
1164<\/td>\nFIGURE G2428.3.11 CONNECTOR RISE
FIGURE G2428.3.11 CONNECTOR RISE <\/td>\n<\/tr>\n
1166<\/td>\nTABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT
TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT <\/td>\n<\/tr>\n
1167<\/td>\nTABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL
TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL <\/td>\n<\/tr>\n
1168<\/td>\nTABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY
TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY <\/td>\n<\/tr>\n
1169<\/td>\nTABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY
TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY <\/td>\n<\/tr>\n
1170<\/td>\nSECTION G2429 (505) – DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION\/EXHAUSTHOOD VENTING
SECTION G2429 (505) – DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION\/EXHAUSTHOOD VENTING
SECTION G2430 (506) – FACTORY-BUILT CHIMNEYS
SECTION G2430 (506) – FACTORY-BUILT CHIMNEYS
FIGURE G2430.1(1) FACTORY-BUILT CHIMNEY
FIGURE G2430.1(1) FACTORY-BUILT CHIMNEY
FIGURE G2430.1(2) FACTORY BUILT AIR-COOLED CHIMNEY SYSTEM
FIGURE G2430.1(2) FACTORY BUILT AIR-COOLED CHIMNEY SYSTEM
SECTION G2431 (601) – GENERAL
SECTION G2431 (601) – GENERAL <\/td>\n<\/tr>\n
1171<\/td>\nSECTION G2432 (602) – DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION G2432 (602) – DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
FIGURE G2432.1 VENTED GAS LOG SET
FIGURE G2432.1 VENTED GAS LOG SET <\/td>\n<\/tr>\n
1172<\/td>\nSECTION G2433 (603) – LOG LIGHTERS
SECTION G2433 (603) – LOG LIGHTERS <\/td>\n<\/tr>\n
1173<\/td>\nFIGURE G2432.2(1) COMBINATION GAS CONTROL
FIGURE G2432.2(1) COMBINATION GAS CONTROL
FIGURE G2432.2(2) COMBINATION GAS CONTROL FOR APPLIANCES
FIGURE G2432.2(2) COMBINATION GAS CONTROL FOR APPLIANCES
SECTION G2434 (604) – VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION G2434 (604) – VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) <\/td>\n<\/tr>\n
1174<\/td>\nFIGURE G2434.1(1) VENTED DECORATIVE APPLIANCE
FIGURE G2434.1(1) VENTED DECORATIVE APPLIANCE
FIGURE G2434.1(2) DIRECT-VENT DECORATIVE APPLIANCE
FIGURE G2434.1(2) DIRECT-VENT DECORATIVE APPLIANCE
FIGURE G2434.1(3) DIRECT-VENT DECORATIVE APPLIANCE
FIGURE G2434.1(3) DIRECT-VENT DECORATIVE APPLIANCE
SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS
SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS <\/td>\n<\/tr>\n
1175<\/td>\nFIGURE G2435.1 VENTED GAS FIREPLACE HEATER
FIGURE G2435.1 VENTED GAS FIREPLACE HEATER
SECTION G2436 (608) – VENTED WALL FURNACES
SECTION G2436 (608) – VENTED WALL FURNACES
SECTION G2437 (609) – FLOOR FURNACES
SECTION G2437 (609) – FLOOR FURNACES <\/td>\n<\/tr>\n
1176<\/td>\nFIGURE G2437.1 FLOOR FURNACE
FIGURE G2437.1 FLOOR FURNACE <\/td>\n<\/tr>\n
1177<\/td>\nSECTION G2438 (613) – CLOTHES DRYERS
SECTION G2438 (613) – CLOTHES DRYERS
FIGURE G2438.1 TYPE I CLOTHES DRYER LABEL
FIGURE G2438.1 TYPE I CLOTHES DRYER LABEL
SECTION G2439 (614) – CLOTHES DRYER EXHAUST
SECTION G2439 (614) – CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n
1180<\/td>\nFIGURE G2439.5.3 DRYER EXHAUST DUCT PROTECTION
FIGURE G2439.5.3 DRYER EXHAUST DUCT PROTECTION <\/td>\n<\/tr>\n
1181<\/td>\nFIGURE G2439.5.6 LENGTH LABEL
FIGURE G2439.5.6 LENGTH LABEL
TABLE G2439.5.5.1 (TABLE 614.6.5.1) DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
TABLE G2439.5.5.1 (TABLE 614.6.5.1) DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
SECTION G2440 (615) – SAUNA HEATERS
SECTION G2440 (615) – SAUNA HEATERS <\/td>\n<\/tr>\n
1182<\/td>\nSECTION G2441 (617) – POOL AND SPA HEATERS
SECTION G2441 (617) – POOL AND SPA HEATERS
SECTION G2442 (618) – FORCED-AIR WARM-AIR FURNACES
SECTION G2442 (618) – FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n
1184<\/td>\nSECTION G2443 (619) – CONVERSION BURNERS
SECTION G2443 (619) – CONVERSION BURNERS
SECTION G2444 (620) – UNIT HEATERS
SECTION G2444 (620) – UNIT HEATERS <\/td>\n<\/tr>\n
1185<\/td>\nFIGURE G2444.1(1) DIRECT-VENT UNIT HEATER
FIGURE G2444.1(1) DIRECT-VENT UNIT HEATER
FIGURE G2444.1(2) POWER-VENTED UNIT HEATER
FIGURE G2444.1(2) POWER-VENTED UNIT HEATER <\/td>\n<\/tr>\n
1186<\/td>\nFIGURE G2444.1(3) UNIT HEATER VENTING (TYPICAL)
FIGURE G2444.1(3) UNIT HEATER VENTING (TYPICAL)
FIGURE G2444.1(4) DRAFT-HOOD-EQUIPPED UNIT HEATER
FIGURE G2444.1(4) DRAFT-HOOD-EQUIPPED UNIT HEATER
FIGURE G2444.1(5) FUNDAMENTAL COMPONENTS OF UNIT HEATER
FIGURE G2444.1(5) FUNDAMENTAL COMPONENTS OF UNIT HEATER <\/td>\n<\/tr>\n
1187<\/td>\nSECTION G2445 (621) – UNVENTED ROOM HEATERS
SECTION G2445 (621) – UNVENTED ROOM HEATERS
FIGURE G2445.1(1) UNVENTED ROOM HEATER
FIGURE G2445.1(1) UNVENTED ROOM HEATER
FIGURE G2445.1(2) UNVENTED ROOM HEATER
FIGURE G2445.1(2) UNVENTED ROOM HEATER <\/td>\n<\/tr>\n
1188<\/td>\nFIGURE G2445.7.1 FIREBOX FOR UNVENTED ROOM HEATER
FIGURE G2445.7.1 FIREBOX FOR UNVENTED ROOM HEATER <\/td>\n<\/tr>\n
1189<\/td>\nSECTION G2446 (622) VENTED ROOM HEATERS
SECTION G2446 (622) VENTED ROOM HEATERS
FIGURE G2446.1 VENTED ROOM HEATER
FIGURE G2446.1 VENTED ROOM HEATER
SECTION G2447 (623) COOKING APPLIANCES
SECTION G2447 (623) COOKING APPLIANCES <\/td>\n<\/tr>\n
1190<\/td>\nFIGURE G2447.3(1) DOMESTIC (HOUSEHOLD) RANGE
FIGURE G2447.3(1) DOMESTIC (HOUSEHOLD) RANGE
FIGURE G2447.3(2) HOUSEHOLD-TYPE COOKING APPLIANCE LABEL
FIGURE G2447.3(2) HOUSEHOLD-TYPE COOKING APPLIANCE LABEL
SECTION G2448 (624) – WATER HEATERS
SECTION G2448 (624) – WATER HEATERS <\/td>\n<\/tr>\n
1191<\/td>\nFIGURE G2448.2(1) DIRECT-VENT WATER HEATER DESIGNED FOR BOTH POTABLE WATER HEATING AND SPACE HEATING APPLICATIONS
FIGURE G2448.2(1) DIRECT-VENT WATER HEATER DESIGNED FOR BOTH POTABLE WATER HEATING AND SPACE HEATING APPLICATIONS
FIGURE G2448.2(2) WATER HEATER LABEL INDICATING SUITABILITY FOR BOTH POTABLE WATER HEATING AND SPACE HEATING
FIGURE G2448.2(2) WATER HEATER LABEL INDICATING SUITABILITY FOR BOTH POTABLE WATER HEATING AND SPACE HEATING <\/td>\n<\/tr>\n
1192<\/td>\nSECTION G2449 (627) – AIR CONDITIONING APPLIANCES
SECTION G2449 (627) – AIR CONDITIONING APPLIANCES
SECTION G2450 (628) – ILLUMINATING APPLIANCES
SECTION G2450 (628) – ILLUMINATING APPLIANCES <\/td>\n<\/tr>\n
1193<\/td>\nSECTION G2451 (630) – INFRARED RADIANT HEATERS
SECTION G2451 (630) – INFRARED RADIANT HEATERS
FIGURE G2451.1(1) CERAMIC BURNER INFRARED RADIANT HEATER
FIGURE G2451.1(1) CERAMIC BURNER INFRARED RADIANT HEATER
FIGURE G2451.1(2) CERAMIC BURNER INFRARED RADIANT HEATER
FIGURE G2451.1(2) CERAMIC BURNER INFRARED RADIANT HEATER <\/td>\n<\/tr>\n
1194<\/td>\nFIGURE G2451.1(3) TUBE-TYPE INFRARED RADIANT HEATER
FIGURE G2451.1(3) TUBE-TYPE INFRARED RADIANT HEATER
FIGURE G2451.1(4) SAMPLE LABEL INFRARED RADIANT TUBE HEATER
FIGURE G2451.1(4) SAMPLE LABEL INFRARED RADIANT TUBE HEATER <\/td>\n<\/tr>\n
1195<\/td>\nSECTION G2452 (631) – BOILERS
SECTION G2452 (631) – BOILERS
FIGURE G2452.1 STEAM HEATING BOILER WITH GAUGE-GLASS,LOW WATER CUTOFF CONTROL, PRESSURE GAUGE, PRESSURE LIMIT CONTROL AND AUTOMATIC VENT DAMPER
FIGURE G2452.1 STEAM HEATING BOILER WITH GAUGE-GLASS,LOW WATER CUTOFF CONTROL, PRESSURE GAUGE, PRESSURE LIMIT CONTROL AND AUTOMATIC VENT DAMPER
FIGURE G2452.2(1) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL WITH GAUGE GLASS AND TRI-COCKS FOR STEAM BOILER APPLICATION
FIGURE G2452.2(1) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL WITH GAUGE GLASS AND TRI-COCKS FOR STEAM BOILER APPLICATION <\/td>\n<\/tr>\n
1196<\/td>\nFIGURE G2452.2(2) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATIO
FIGURE G2452.2(2) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATIO
FIGURE G2452.2(3) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
FIGURE G2452.2(3) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES <\/td>\n<\/tr>\n
1197<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1199<\/td>\nPART VII – PLUMBING
PART VII – PLUMBING
CHAPTER 25: PLUMBING ADMINISTRATION
CHAPTER 25: PLUMBING ADMINISTRATION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P2501 – GENERAL
SECTION P2501 – GENERAL
SECTION P2502 – EXISTING PLUMBING SYSTEMS
SECTION P2502 – EXISTING PLUMBING SYSTEMS <\/td>\n<\/tr>\n
1200<\/td>\nSECTION P2503 – INSPECTION AND TESTS
SECTION P2503 – INSPECTION AND TESTS <\/td>\n<\/tr>\n
1202<\/td>\nFIGURE P2503.6(1) TESTING OF FIELD-FABRICATED SHOWER LINER
FIGURE P2503.6(1) TESTING OF FIELD-FABRICATED SHOWER LINER
FIGURE P2503.6(2) INSTALLED SHOWER LINER READY FOR TESTING
FIGURE P2503.6(2) INSTALLED SHOWER LINER READY FOR TESTING <\/td>\n<\/tr>\n
1203<\/td>\nFIGURE P2503.9 – IMPROPER GAUGE FOR TEST(DIAL INCREMENTS TOO LARGE)
FIGURE P2503.9 – IMPROPER GAUGE FOR TEST(DIAL INCREMENTS TOO LARGE) <\/td>\n<\/tr>\n
1204<\/td>\nBIBIOGRAPHY
BIBIOGRAPHY <\/td>\n<\/tr>\n
1205<\/td>\nCHAPTER 26: GENERAL PLUMBING REQUIRMENTS
CHAPTER 26: GENERAL PLUMBING REQUIRMENTS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P2601 – GENERAL
SECTION P2601 – GENERAL
SECTION P2602 – INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL
SECTION P2602 – INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL <\/td>\n<\/tr>\n
1206<\/td>\nSECTION P2603 – STRUCTURAL AND PIPING PROTECTION
SECTION P2603 – STRUCTURAL AND PIPING PROTECTION <\/td>\n<\/tr>\n
1207<\/td>\nFIGURE P2603.2(1) NOTCHING AND BORING IN A WOOD STUD WALL
FIGURE P2603.2(1) NOTCHING AND BORING IN A WOOD STUD WALL <\/td>\n<\/tr>\n
1208<\/td>\nFIGURE P2603.2(2) VIOLATION: NOTCHES TOO DEEP IN STUD
FIGURE P2603.2(2) VIOLATION: NOTCHES TOO DEEP IN STUD
FIGURE P2603.2(3) VIOLATION: EXTERIOR STUD NOTCHED TOO DEEP
FIGURE P2603.2(3) VIOLATION: EXTERIOR STUD NOTCHED TOO DEEP <\/td>\n<\/tr>\n
1209<\/td>\nFIGURE P2603.2(4) VIOLATION: EXTERIOR STUD COMPLETELY SEVERED
FIGURE P2603.2(4) VIOLATION: EXTERIOR STUD COMPLETELY SEVERED
FIGURE P2603.2(5) VIOLATION: WALL TOP PLATE NOT REINFORCED
FIGURE P2603.2(5) VIOLATION: WALL TOP PLATE NOT REINFORCED <\/td>\n<\/tr>\n
1210<\/td>\nFIGURE P2603.2(6) VIOLATION: WALL TOP PLATE NOT REINFORCED
FIGURE P2603.2(6) VIOLATION: WALL TOP PLATE NOT REINFORCED <\/td>\n<\/tr>\n
1211<\/td>\nFIGURE P2603.2(7) LAMINATED VENEER LUMBER BEAM
FIGURE P2603.2(7) LAMINATED VENEER LUMBER BEAM
FIGURE P2603.2(8) VIOLATION: TOP CHORD OF TRUSS NOTCHED
FIGURE P2603.2(8) VIOLATION: TOP CHORD OF TRUSS NOTCHED <\/td>\n<\/tr>\n
1212<\/td>\nFIGURE P2603.2(9) VIOLATION: HOLE IN BOTTOM CHORD OF ROOF TRUSS
FIGURE P2603.2(9) VIOLATION: HOLE IN BOTTOM CHORD OF ROOF TRUSS
FIGURE P2603.2(10) VIOLATION: TOP CHORD OF I-JOIST COMPLETELY SEVERED
FIGURE P2603.2(10) VIOLATION: TOP CHORD OF I-JOIST COMPLETELY SEVERED <\/td>\n<\/tr>\n
1213<\/td>\nFIGURE P2603.2(11) VIOLATION: I-JOIST WEB HOLES IRREGULAR SHAPE, TOO LARGE, TOO CLOSE TOGETHER
FIGURE P2603.2(11) VIOLATION: I-JOIST WEB HOLES IRREGULAR SHAPE, TOO LARGE, TOO CLOSE TOGETHER <\/td>\n<\/tr>\n
1214<\/td>\nFIGURE P2603.2.1(1) REQUIRED SHIELD PLATES
FIGURE P2603.2.1(1) REQUIRED SHIELD PLATES
FIGURE P2603.2.1(2) PIPE PROTECTION VIOLATION
FIGURE P2603.2.1(2) PIPE PROTECTION VIOLATION <\/td>\n<\/tr>\n
1215<\/td>\nFIGURE P2603.4(1) PIPE PROTECTION
FIGURE P2603.4(1) PIPE PROTECTION
FIGURE P2603.4(2) ANNULAR SPACE PROTECTION
FIGURE P2603.4(2) ANNULAR SPACE PROTECTION <\/td>\n<\/tr>\n
1216<\/td>\nFIGURE P2603.5 PIPE PROTECTION
FIGURE P2603.5 PIPE PROTECTION
SECTION P2604 – TRENCHING AND BACKFILLING
SECTION P2604 – TRENCHING AND BACKFILLING <\/td>\n<\/tr>\n
1217<\/td>\nFIGURE P2603.6 PROTECTION AGAINST FREEZING
FIGURE P2603.6 PROTECTION AGAINST FREEZING
SECTION P2605 – SUPPORT
SECTION P2605 – SUPPORT <\/td>\n<\/tr>\n
1218<\/td>\nFIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS
FIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS
SECTION P2606 – WATERPROOFING OF OPENINGS
SECTION P2606 – WATERPROOFING OF OPENINGS
FIGURE P2606.1 ROOF PENETRATIONS
FIGURE P2606.1 ROOF PENETRATIONS <\/td>\n<\/tr>\n
1219<\/td>\nTABLE P2605.1 PIPING SUPPORT
TABLE P2605.1 PIPING SUPPORT <\/td>\n<\/tr>\n
1220<\/td>\nFIGURE P2605.1(1) SWAY BRACING
FIGURE P2605.1(1) SWAY BRACING
FIGURE P2605.1(2) POINT OF SAG BETWEEN HANGERS
FIGURE P2605.1(2) POINT OF SAG BETWEEN HANGERS
FIGURE P2605.1(3) LOCATION OF HANGERS
FIGURE P2605.1(3) LOCATION OF HANGERS <\/td>\n<\/tr>\n
1221<\/td>\nSECTION P2607 – WORKMANSHIP
SECTION P2607 – WORKMANSHIP
FIGURE P2607.1 PREPARATION OF PIPE END
FIGURE P2607.1 PREPARATION OF PIPE END
SECTION P2608 – MATERIALS EVALUATION AND LISTING
SECTION P2608 – MATERIALS EVALUATION AND LISTING <\/td>\n<\/tr>\n
1222<\/td>\nTABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
TABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
FIGURE P2608.4 SAMPLE MARKING OF PVC PRESSURE PIPE
FIGURE P2608.4 SAMPLE MARKING OF PVC PRESSURE PIPE <\/td>\n<\/tr>\n
1223<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1225<\/td>\nCHAPTER 27: PLUMBING FIXTURES
\n
CHAPTER 27: PLUMBING FIXTURES
\n
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P2701 – FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION P2701 – FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION P2702 – FIXTURE ACCESSORIES
SECTION P2702 – FIXTURE ACCESSORIES <\/td>\n<\/tr>\n
1226<\/td>\nTABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS
TABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS <\/td>\n<\/tr>\n
1227<\/td>\nFIGURE P2702.4 WALL-MOUNTED WATER CLOSET
FIGURE P2702.4 WALL-MOUNTED WATER CLOSET
SECTION P2703 – TAIL PIECES
SECTION P2703 – TAIL PIECES
SECTION P2704 – ACCESS TO CONNECTIONS
SECTION P2704 – ACCESS TO CONNECTIONS <\/td>\n<\/tr>\n
1228<\/td>\nSECTION P2705 – INSTALLATION
SECTION P2705 – INSTALLATION
FIGURE P2705.1 FIXTURES CLEARANCES
FIGURE P2705.1 FIXTURES CLEARANCES <\/td>\n<\/tr>\n
1229<\/td>\nSECTION P2706 – WASTE RECEPTORS
SECTION P2706 – WASTE RECEPTORS
FIGURE P2706.1 WASTE RECEPTOR
FIGURE P2706.1 WASTE RECEPTOR <\/td>\n<\/tr>\n
1230<\/td>\nFIGURE P2706.2 STANDPIPES
FIGURE P2706.2 STANDPIPES
FIGURE P2706.2.1 LAUNDRY TUB CONNECTION TO STANDPIPE
FIGURE P2706.2.1 LAUNDRY TUB CONNECTION TO STANDPIPE <\/td>\n<\/tr>\n
1231<\/td>\nSECTION P2707 – DIRECTIONAL FITTINGS
SECTION P2707 – DIRECTIONAL FITTINGS
SECTION P2708 – SHOWERS
SECTION P2708 – SHOWERS <\/td>\n<\/tr>\n
1232<\/td>\nFIGURE P2708.1 SHOWER COMPARTMENT
FIGURE P2708.1 SHOWER COMPARTMENT
FIGURE P2708.2(1) SECURING SHOWER RISER
FIGURE P2708.2(1) SECURING SHOWER RISER <\/td>\n<\/tr>\n
1233<\/td>\nFIGURE P2708.2(2) SPECIAL BRACKET FOR SHOWER RISER (Photo courtesy of Holdrite-Hubbard Enterprises)
FIGURE P2708.2(2) SPECIAL BRACKET FOR SHOWER RISER (Photo courtesy of Holdrite-Hubbard Enterprises)
FIGURE P2708.3 TEMPERATURE BURN CHART
FIGURE P2708.3 TEMPERATURE BURN CHART <\/td>\n<\/tr>\n
1234<\/td>\nSECTION P2709 – SHOWER RECEPTORS
SECTION P2709 – SHOWER RECEPTORS
FIGURE P2709.1 SHOWER DRAIN AND PAN CONNECTION
FIGURE P2709.1 SHOWER DRAIN AND PAN CONNECTION <\/td>\n<\/tr>\n
1235<\/td>\nSECTION P2710 – SHOWER WALLS
SECTION P2710 – SHOWER WALLS
SECTION P2711 – LAVATORIES
SECTION P2711 – LAVATORIES <\/td>\n<\/tr>\n
1236<\/td>\nSECTION P2712 – WATER CLOSETS
SECTION P2712 – WATER CLOSETS <\/td>\n<\/tr>\n
1237<\/td>\nSECTION P2713 – BATHTUBS
SECTION P2713 – BATHTUBS <\/td>\n<\/tr>\n
1238<\/td>\nFIGURE P2713 3 HOT WATER TEMPERATURE LIMITS
FIGURE P2713 3 HOT WATER TEMPERATURE LIMITS
SECTION P2714 – SINKS
SECTION P2714 – SINKS
SECTION P2715 – LAUNDRY TUBS
SECTION P2715 – LAUNDRY TUBS
SECTION P2716 – FOOD WASTE GRINDER
SECTION P2716 – FOOD WASTE GRINDER <\/td>\n<\/tr>\n
1239<\/td>\nSECTION P2717 – DISHWASHING MACHINES
SECTION P2717 – DISHWASHING MACHINES
FIGURE P2717.2 DISHWASHER WASTE CONNECTIONS
FIGURE P2717.2 DISHWASHER WASTE CONNECTIONS
SECTION P2718 – CLOTHES WASHING MACHINE
SECTION P2718 – CLOTHES WASHING MACHINE <\/td>\n<\/tr>\n
1240<\/td>\nSECTION P2719 – FLOOR DRAINS
SECTION P2719 – FLOOR DRAINS
SECTION P2720 – WHIRLPOOL BATHTUBS
SECTION P2720 – WHIRLPOOL BATHTUBS
FIGURE P2720.1(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS
FIGURE P2720.1(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS <\/td>\n<\/tr>\n
1241<\/td>\nFIGURE P2720.1(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS
FIGURE P2720.1(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS
SECTION P2721 – BIDET INSTALLATIONS
SECTION P2721 – BIDET INSTALLATIONS
SECTION P2722 – FIXTURE FITTING
SECTION P2722 – FIXTURE FITTING <\/td>\n<\/tr>\n
1242<\/td>\nSECTION P2723 – MACERATING TOILET SYSTEMS
SECTION P2723 – MACERATING TOILET SYSTEMS
SECTION P2724 – SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES
SECTION P2724 – SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES <\/td>\n<\/tr>\n
1243<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1245<\/td>\nCHAPTER 28: WATER HEATERS
CHAPTER 28: WATER HEATERS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P2801 – GENERAL
SECTION P2801 – GENERAL <\/td>\n<\/tr>\n
1246<\/td>\nFIGURE P2801.5 WATER HEATER IN DRAIN PAN
FIGURE P2801.5 WATER HEATER IN DRAIN PAN <\/td>\n<\/tr>\n
1248<\/td>\nSECTION P2802 – WATER HEATERS USED FOR SPACE HEATING
SECTION P2802 – WATER HEATERS USED FOR SPACE HEATING
SECTION P2803 – RELIEF VALVES
SECTION P2803 – RELIEF VALVES <\/td>\n<\/tr>\n
1249<\/td>\nFIGURE P2801.7 EXAMPLE OF SEISMIC RESTRAINT FOR SMALL WATER HEATERS
FIGURE P2801.7 EXAMPLE OF SEISMIC RESTRAINT FOR SMALL WATER HEATERS <\/td>\n<\/tr>\n
1250<\/td>\nFIGURE P2803.4 TEMPERATURE AND PRESSURE RELIEF VALVE INSTALLATION
FIGURE P2803.4 TEMPERATURE AND PRESSURE RELIEF VALVE INSTALLATION <\/td>\n<\/tr>\n
1252<\/td>\nFIGURE P2803.7 BOTTOM FED WATER HEATER
FIGURE P2803.7 BOTTOM FED WATER HEATER
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1255<\/td>\nCHAPTER 29: WATER SUPPLY AND DISTRIBUTION
CHAPTER 29: WATER SUPPLY AND DISTRIBUTION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P2901 – GENERAL
SECTION P2901 – GENERAL
SECTION P2902 – PROTECTION OF POTABLE WATER SUPPLY
SECTION P2902 – PROTECTION OF POTABLE WATER SUPPLY <\/td>\n<\/tr>\n
1256<\/td>\nFIGURE P2902.1(1) EXAMPLE OF A SIMPLE SIPHON
FIGURE P2902.1(1) EXAMPLE OF A SIMPLE SIPHON <\/td>\n<\/tr>\n
1257<\/td>\nFIGURE P2902.1(2) EXAMPLE OF ASPIRATION OR VENTURI PRINCIPLE
FIGURE P2902.1(2) EXAMPLE OF ASPIRATION OR VENTURI PRINCIPLE
FIGURE P2902.1(3) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE
FIGURE P2902.1(3) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE <\/td>\n<\/tr>\n
1258<\/td>\nTABLE P2902.3 APPLICATION FOR BACKFLOW PREVENTERS
TABLE P2902.3 APPLICATION FOR BACKFLOW PREVENTERS <\/td>\n<\/tr>\n
1259<\/td>\nTABLE P2902.3.1 MINIMUM AIR GAPS
TABLE P2902.3.1 MINIMUM AIR GAPS
FIGURE P2902.3.1(1) AIR GAP FOR A LAVATORY FAUCET
FIGURE P2902.3.1(1) AIR GAP FOR A LAVATORY FAUCET <\/td>\n<\/tr>\n
1260<\/td>\nFIGURE P2902.3.1(2) AIR GAPS\u2014LOCATED NEAR SINGLE WALL
FIGURE P2902.3.1(2) AIR GAPS\u2014LOCATED NEAR SINGLE WALL
FIGURE P2902.3.1(3) AIR GAPS\u2014LOCATED NEAR INTERSECTING WALLS
FIGURE P2902.3.1(3) AIR GAPS\u2014LOCATED NEAR INTERSECTING WALLS <\/td>\n<\/tr>\n
1262<\/td>\nFIGURE P2902.3.4 PRESSURE VACUUM BREAKER
FIGURE P2902.3.4 PRESSURE VACUUM BREAKER <\/td>\n<\/tr>\n
1263<\/td>\nFIGURE P2902.3.5 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER
FIGURE P2902.3.5 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER <\/td>\n<\/tr>\n
1264<\/td>\nFIGURE P2902.4.3 HOSE CONNECTION VACUUM BREAKER
FIGURE P2902.4.3 HOSE CONNECTION VACUUM BREAKER <\/td>\n<\/tr>\n
1266<\/td>\nSECTION P2903 – WATER-SUPPLY SYSTEM
SECTION P2903 – WATER-SUPPLY SYSTEM <\/td>\n<\/tr>\n
1267<\/td>\nTABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE
TABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE
TABLEP2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGSb
TABLEP2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGSb <\/td>\n<\/tr>\n
1268<\/td>\nFIGURE P2903.4 EXAMPLE METHOD OF THERMAL EXPANSION
FIGURE P2903.4 EXAMPLE METHOD OF THERMAL EXPANSION <\/td>\n<\/tr>\n
1269<\/td>\nFIGURE 2903.5 EXAMPLE OF MECHANICAL WATER HAMMER ARRESTORS
FIGURE 2903.5 EXAMPLE OF MECHANICAL WATER HAMMER ARRESTORS <\/td>\n<\/tr>\n
1270<\/td>\nTABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS
TABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS <\/td>\n<\/tr>\n
1271<\/td>\nTABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES
TABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES <\/td>\n<\/tr>\n
1272<\/td>\nFIGURE P2903.8 SIMPLIFIED SCHEMATIC OF PARALLEL WATER DISTRIBUTION
FIGURE P2903.8 SIMPLIFIED SCHEMATIC OF PARALLEL WATER DISTRIBUTION
TABLE P2903.8.1 MANIFOLD SIZING
TABLE P2903.8.1 MANIFOLD SIZING <\/td>\n<\/tr>\n
1273<\/td>\nFIGURE P2903.9.1(1) CURB VALVE ON WATER SUPPLY
FIGURE P2903.9.1(1) CURB VALVE ON WATER SUPPLY <\/td>\n<\/tr>\n
1274<\/td>\nFIGURE P2903.9.1(2) VALVE AT ENTRANCE TO THE BUILDING AND ON THE DISCHARGE SIDE OF THE METER
FIGURE P2903.9.1(2) VALVE AT ENTRANCE TO THE BUILDING AND ON THE DISCHARGE SIDE OF THE METER
FIGURE P2903.9.1(3) DWELLING UNIT VALVE
FIGURE P2903.9.1(3) DWELLING UNIT VALVE <\/td>\n<\/tr>\n
1275<\/td>\nFIGURE P2903.9.5(1) FROST-PROOF YARD HYDRANT WITH STOP-AND-WASTE VALVE BELOW GRADE
FIGURE P2903.9.5(1) FROST-PROOF YARD HYDRANT WITH STOP-AND-WASTE VALVE BELOW GRADE <\/td>\n<\/tr>\n
1276<\/td>\nFIGURE P2903.9.5(2) VIOLATION: FROSTPROOF YARD HYDRANT CONNECTED TO WATER SERVICE LINE
FIGURE P2903.9.5(2) VIOLATION: FROSTPROOF YARD HYDRANT CONNECTED TO WATER SERVICE LINE
FIGURE P2903.9.5(3) SANITARY FROSTPROOF YARD HYDRANT
FIGURE P2903.9.5(3) SANITARY FROSTPROOF YARD HYDRANT <\/td>\n<\/tr>\n
1277<\/td>\nFIGURE P2903.9.5(4) PROPER INSTALLATION OF FROSTPROOF YARD HYDRANT WITH STOP-AND-WASTE VALVE BELOW GRADE
FIGURE P2903.9.5(4) PROPER INSTALLATION OF FROSTPROOF YARD HYDRANT WITH STOP-AND-WASTE VALVE BELOW GRADE
FIGURE P2903.10 TYPICAL FREEZE-PROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALVE
FIGURE P2903.10 TYPICAL FREEZE-PROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALVE <\/td>\n<\/tr>\n
1278<\/td>\nSECTION P2904 – DWELLING UNIT FIRE SPRINKLER SYSTEMS
SECTION P2904 – DWELLING UNIT FIRE SPRINKLER SYSTEMS <\/td>\n<\/tr>\n
1279<\/td>\nFIGURE P2904.2(1) PENDANT SPRINKLER
FIGURE P2904.2(1) PENDANT SPRINKLER
FIGURE P2904.2(2) HORIZONTAL SIDEWALL SPRINKLER
FIGURE P2904.2(2) HORIZONTAL SIDEWALL SPRINKLER <\/td>\n<\/tr>\n
1280<\/td>\nFIGURE P2904.2.2 SPRINKLER PLACEMENT NEAR CEILING-MOUNTED WARM AIR REGISTER
FIGURE P2904.2.2 SPRINKLER PLACEMENT NEAR CEILING-MOUNTED WARM AIR REGISTER
TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED <\/td>\n<\/tr>\n
1283<\/td>\nTABLE SPRINKLER MODE A, PENDENT, K = 3.1
TABLE SPRINKLER MODE A, PENDENT, K = 3.1
TABLE SPRINKLER MODEL B, PENDENT, K = 4.3
TABLE SPRINKLER MODEL B, PENDENT, K = 4.3
TABLE SPRINKLER MODEL C, HORIZONTAL SIDEWALL, DEFLECTOR, 4-6 INCHES FROM CEILING, K = 4.0
TABLE SPRINKLER MODEL C, HORIZONTAL SIDEWALL, DEFLECTOR, 4-6 INCHES FROM CEILING, K = 4.0
TABLE SPRINKLER MODEL D, HORIZONTAL SIDEWALL, DEFLECTOR 4-6 INCHES FROM CEILING, K = 4.3
TABLE SPRINKLER MODEL D, HORIZONTAL SIDEWALL, DEFLECTOR 4-6 INCHES FROM CEILING, K = 4.3 <\/td>\n<\/tr>\n
1285<\/td>\nEQUATION 29-1
EQUATION 29-1 <\/td>\n<\/tr>\n
1286<\/td>\nTABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS
TABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS <\/td>\n<\/tr>\n
1287<\/td>\nTABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)
TABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm) <\/td>\n<\/tr>\n
1288<\/td>\nTABLE P2904.6.2(3) ELEVATION LOSS (PLe)
TABLE P2904.6.2(3) ELEVATION LOSS (PLe) <\/td>\n<\/tr>\n
1290<\/td>\nTABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH TYPE M COPPER WATER TUBING
TABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH TYPE M COPPER WATER TUBING <\/td>\n<\/tr>\n
1291<\/td>\nTABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
TABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING <\/td>\n<\/tr>\n
1292<\/td>\nTABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH CPVC PIPE
TABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH CPVC PIPE <\/td>\n<\/tr>\n
1293<\/td>\nTABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
TABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE <\/td>\n<\/tr>\n
1294<\/td>\nTABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH PEX TUBING
TABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3\/4-INCH PEX TUBING <\/td>\n<\/tr>\n
1295<\/td>\nTABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX TUBING
TABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX TUBING <\/td>\n<\/tr>\n
1296<\/td>\nFIGURE P2904.6.2.2(1) BUILDING PLAN
FIGURE P2904.6.2.2(1) BUILDING PLAN
FIGURE P2904.6.2.2(2) LOCATIONS OF SPRINKLER
FIGURE P2904.6.2.2(2) LOCATIONS OF SPRINKLER <\/td>\n<\/tr>\n
1297<\/td>\nFIGURE P2904.6.2.2(3) PIPING TO SPRINKLER
FIGURE P2904.6.2.2(3) PIPING TO SPRINKLER <\/td>\n<\/tr>\n
1298<\/td>\nFIGURE P2904.8.1(1) SPRINKLER SYSTEM ROUGH-IN
FIGURE P2904.8.1(1) SPRINKLER SYSTEM ROUGH-IN
SECTION P2905 MATERIALS, JOINTS AND CONNECTIONS
SECTION P2905 MATERIALS, JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
1299<\/td>\nFIGURE P2904.8.1(2) SPRINKLER SHOWN WITHOUT TEMPORARY PROTECTIVE COVER INSTALLED
FIGURE P2904.8.1(2) SPRINKLER SHOWN WITHOUT TEMPORARY PROTECTIVE COVER INSTALLED <\/td>\n<\/tr>\n
1300<\/td>\nFIGURE P2905.3 BENDING
FIGURE P2905.3 BENDING <\/td>\n<\/tr>\n
1301<\/td>\nTABLE P2905.4 WATER SERVICE PIPE
TABLE P2905.4 WATER SERVICE PIPE
FIGURE P2905.4(1) WATER SERVICE MATERIAL TRANSITIONS
FIGURE P2905.4(1) WATER SERVICE MATERIAL TRANSITIONS <\/td>\n<\/tr>\n
1303<\/td>\nFIGURE P2905.4(2) SAMPLE MARKING OF PEX TUBING
FIGURE P2905.4(2) SAMPLE MARKING OF PEX TUBING <\/td>\n<\/tr>\n
1305<\/td>\nFIGURE P2905.4.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER
FIGURE P2905.4.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER
FIGURE P2905.4.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER
FIGURE P2905.4.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER <\/td>\n<\/tr>\n
1306<\/td>\nTABLE P2905.5 WATER DISTRIBUTION PIPE
TABLE P2905.5 WATER DISTRIBUTION PIPE <\/td>\n<\/tr>\n
1307<\/td>\nTABLE P2905.6 PIPE FITTINGS
TABLE P2905.6 PIPE FITTINGS <\/td>\n<\/tr>\n
1310<\/td>\nFIGURE P2905.14 PREPARATION OF PIPE END
FIGURE P2905.14 PREPARATION OF PIPE END
FIGURE P2905.15 TYPICAL FLARED JOINT
FIGURE P2905.15 TYPICAL FLARED JOINT <\/td>\n<\/tr>\n
1311<\/td>\nFIGURE P2905.15 HEAT APPLICATION OF BRAZED JOINT
FIGURE P2905.15 HEAT APPLICATION OF BRAZED JOINT
FIGURE P2905.17.1 DIELECTRIC UNION
FIGURE P2905.17.1 DIELECTRIC UNION <\/td>\n<\/tr>\n
1312<\/td>\nSECTION P2906 – CHANGES IN DIRECTION
SECTION P2906 – CHANGES IN DIRECTION
SECTION P2907 – SUPPORT
SECTION P2907 – SUPPORT
SECTION P2908 – DRINKING WATER TREATMENT UNITS
SECTION P2908 – DRINKING WATER TREATMENT UNITS <\/td>\n<\/tr>\n
1313<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1315<\/td>\nCHAPTER 30: SANITARY DRAINAGE
CHAPTER 30: SANITARY DRAINAGE
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P3001 – GENERAL
SECTION P3001 – GENERAL <\/td>\n<\/tr>\n
1316<\/td>\nSECTION P3002 – MATERIALS
SECTION P3002 – MATERIALS <\/td>\n<\/tr>\n
1317<\/td>\nTABLE P3002.1(1) ABOVE-GROUND DRAINAGE AND VENT PIPE
TABLE P3002.1(1) ABOVE-GROUND DRAINAGE AND VENT PIPE
TABLE P3002.1(2) UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE P3002.1(2) UNDERGROUND BUILDING DRAINAGE AND VENT PIPE <\/td>\n<\/tr>\n
1318<\/td>\nTABLE P3002.2 BUILDING SEWER PIPE
TABLE P3002.2 BUILDING SEWER PIPE <\/td>\n<\/tr>\n
1319<\/td>\nTABLE P3002.3 PIPE FITTINGS
TABLE P3002.3 PIPE FITTINGS
SECTION P3003 – JOINTS AND CONNECTIONS
SECTION P3003 – JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
1327<\/td>\nSECTION P3004 – DETERMINING DRAINAGE FIXTURE UNITS
SECTION P3004 – DETERMINING DRAINAGE FIXTURE UNITS
SECTION P3005 – DRAINAGE SYSTEM
SECTION P3005 – DRAINAGE SYSTEM
TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION
TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION <\/td>\n<\/tr>\n
1328<\/td>\nTABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES
TABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES <\/td>\n<\/tr>\n
1329<\/td>\nFIGURE P3005.1(1) COMPARISON OF DIFFERENT 11\/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS
FIGURE P3005.1(1) COMPARISON OF DIFFERENT 11\/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIALS
FIGURE P3005.1(2) COMPARISON FOR 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIA
FIGURE P3005.1(2) COMPARISON FOR 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIA <\/td>\n<\/tr>\n
1330<\/td>\nFIGURE P3005.1(3) DRAINAGE PATTERN FITTINGS
FIGURE P3005.1(3) DRAINAGE PATTERN FITTINGS
FIGURE P3005.1(4) DRAINAGE PATTERN FITTINGS
FIGURE P3005.1(4) DRAINAGE PATTERN FITTINGS <\/td>\n<\/tr>\n
1331<\/td>\nFIGURE P3005.1(5) DIFFERENCE BETWEEN PVC PLASTIC 1\/4-BEND SHORT SWEEP AND 1\/4-BEND VENT ELBOW
FIGURE P3005.1(5) DIFFERENCE BETWEEN PVC PLASTIC 1\/4-BEND SHORT SWEEP AND 1\/4-BEND VENT ELBOW
FIGURE P3005.1(6) COMBINATION TEES
FIGURE P3005.1(6) COMBINATION TEES
FIGURE P3005.1(7) FITTING USES
FIGURE P3005.1(7) FITTING USES <\/td>\n<\/tr>\n
1332<\/td>\nFIGURE P3005.1.1 DOUBLE SANITARY TEE APPLICATION WITH WATER CLOSETS
FIGURE P3005.1.1 DOUBLE SANITARY TEE APPLICATION WITH WATER CLOSETS <\/td>\n<\/tr>\n
1333<\/td>\nFIGURE P3005.1.2(1) HEEL-INLET FITTINGS
FIGURE P3005.1.2(1) HEEL-INLET FITTINGS
FIGURE P3005.1.2(2) IMPROPER PIPING INSTALLATION
FIGURE P3005.1.2(2) IMPROPER PIPING INSTALLATION <\/td>\n<\/tr>\n
1335<\/td>\nFIGURE P3005.2.3(1) CLEANOUT LOCATIONS
FIGURE P3005.2.3(1) CLEANOUT LOCATIONS
FIGURE P3005.2.2 CLEANOUT LOCATIONS
FIGURE P3005.2.2 CLEANOUT LOCATIONS <\/td>\n<\/tr>\n
1336<\/td>\nFIGURE P3005.2.3(2) CLEANOUTS ON CONCEALED PIPING
FIGURE P3005.2.3(2) CLEANOUTS ON CONCEALED PIPING
FIGURE P3005.2.4 CLEANOUTS AT CHANGE OF DIRECTION
FIGURE P3005.2.4 CLEANOUTS AT CHANGE OF DIRECTION <\/td>\n<\/tr>\n
1337<\/td>\nFIGURE P3005.2.5 CLEARANCE FOR CLEANOUTS
FIGURE P3005.2.5 CLEARANCE FOR CLEANOUTS
FIGURE P3005.2.6 CLEANOUT AT BASE OF STACK
FIGURE P3005.2.6 CLEANOUT AT BASE OF STACK <\/td>\n<\/tr>\n
1338<\/td>\nFIGURE P3005.2.7 CLEANOUTS AT SEWER JUNCTION
FIGURE P3005.2.7 CLEANOUTS AT SEWER JUNCTION <\/td>\n<\/tr>\n
1340<\/td>\nFIGURE P3005.4 DRAIN LINE LAYOUT
FIGURE P3005.4 DRAIN LINE LAYOUT
TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWEDTO BE CONNECTED TO BRANCHES AND STACKS
TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWEDTO BE CONNECTED TO BRANCHES AND STACKS <\/td>\n<\/tr>\n
1341<\/td>\nTABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN,BUILDING DRAIN BRANCHES OR THE BUILDING SEWER
TABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN,BUILDING DRAIN BRANCHES OR THE BUILDING SEWER
SECTION P3006 – SIZING OF DRAIN PIPE OFFSETS
SECTION P3006 – SIZING OF DRAIN PIPE OFFSETS <\/td>\n<\/tr>\n
1342<\/td>\nSECTION P3007 – SUMPS AND EJECTORS
SECTION P3007 – SUMPS AND EJECTORS
FIGURE P3007.1 SUBMERSIBLE SEWAGE PUMP
FIGURE P3007.1 SUBMERSIBLE SEWAGE PUMP <\/td>\n<\/tr>\n
1343<\/td>\nFIGURE P3007.2 VERTICAL SUSPENDED WET-PIT SEWAGE PUMP
FIGURE P3007.2 VERTICAL SUSPENDED WET-PIT SEWAGE PUMP <\/td>\n<\/tr>\n
1345<\/td>\nFIGURE P3007.5(1) MACERATING TOILET SYSTEMS
FIGURE P3007.5(1) MACERATING TOILET SYSTEMS <\/td>\n<\/tr>\n
1346<\/td>\nSECTION P3008 – BACKWATER VALVES
SECTION P3008 – BACKWATER VALVES
FIGURE P3007.5(2) MACERATING TOILET SYSTEMS
FIGURE P3007.5(2) MACERATING TOILET SYSTEMS
TABLE 3007.6 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
TABLE 3007.6 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR <\/td>\n<\/tr>\n
1347<\/td>\nFIGURE P3008.1(1) BACKWATER VALVE LOCATION
FIGURE P3008.1(1) BACKWATER VALVE LOCATION <\/td>\n<\/tr>\n
1348<\/td>\nFIGURE P3008.1(2) BACKWATER VALVES
FIGURE P3008.1(2) BACKWATER VALVES
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1351<\/td>\nCHAPTER 31: VENTS
CHAPTER 31: VENTS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P3101 – VENT SYSTEMS
SECTION P3101 – VENT SYSTEMS <\/td>\n<\/tr>\n
1352<\/td>\nSECTION P3102 – VENT STACKS AND STACK VENTS
SECTION P3102 – VENT STACKS AND STACK VENTS
FIGURE P3102.2 AT LEAST ONE VENT TO THE OUTDOORS
FIGURE P3102.2 AT LEAST ONE VENT TO THE OUTDOORS <\/td>\n<\/tr>\n
1353<\/td>\nSECTION P3103 – VENT TERMINALS
SECTION P3103 – VENT TERMINALS
FIGURE P3103.1 VENT TERMINAL
FIGURE P3103.1 VENT TERMINAL <\/td>\n<\/tr>\n
1354<\/td>\nFIGURE P3103.5 VENT TERMINAL CLEARANCES
FIGURE P3103.5 VENT TERMINAL CLEARANCES <\/td>\n<\/tr>\n
1355<\/td>\nFIGURE P3103.6 VENT TERMINATION THROUGH EXTERIOR WALL
FIGURE P3103.6 VENT TERMINATION THROUGH EXTERIOR WALL
SECTION P3104 – VENT CONNECTIONS AND GRADES
SECTION P3104 – VENT CONNECTIONS AND GRADES <\/td>\n<\/tr>\n
1356<\/td>\nFIGURE P3104.2 GRADE OF VENTS
FIGURE P3104.2 GRADE OF VENTS
FIGURE P3104.3 VENT CONNECTIONS
FIGURE P3104.3 VENT CONNECTIONS <\/td>\n<\/tr>\n
1357<\/td>\nFIGURE P3104.4 PROHIBITED HORIZONTAL VENT PIPING
FIGURE P3104.4 PROHIBITED HORIZONTAL VENT PIPING <\/td>\n<\/tr>\n
1358<\/td>\nFIGURE P3104.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN
FIGURE P3104.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN
FIGURE P3104.5(2) HORIZONTAL OFFSET OF BRANCH VENT
FIGURE P3104.5(2) HORIZONTAL OFFSET OF BRANCH VENT
SECTION P3105 – FIXTURE VENTS
SECTION P3105 – FIXTURE VENTS <\/td>\n<\/tr>\n
1359<\/td>\nTABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
TABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
FIGURE P3105.1(1) TRAP TO VENT DISTANCE FOR WET VENT BRANCH
FIGURE P3105.1(1) TRAP TO VENT DISTANCE FOR WET VENT BRANCH <\/td>\n<\/tr>\n
1360<\/td>\nFIGURE P3105.1(2) TRAP TO VENT DISTANCE FOR WATER CLOSETS
FIGURE P3105.1(2) TRAP TO VENT DISTANCE FOR WATER CLOSETS
FIGURE P3105.2 MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT
FIGURE P3105.2 MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT <\/td>\n<\/tr>\n
1361<\/td>\nFIGURE P3105.3(1) CROWN VENTING
FIGURE P3105.3(1) CROWN VENTING
FIGURE P3105.3(2) CROWN VENTING
FIGURE P3105.3(2) CROWN VENTING
SECTION P3106 – INDIVIDUAL VENT
SECTION P3106 – INDIVIDUAL VENT
FIGURE P3106.1(1) INDIVIDUAL VENTS
FIGURE P3106.1(1) INDIVIDUAL VENTS
FIGURE P3106.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS
FIGURE P3106.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS
SECTION P3107 – COMMON VENT
SECTION P3107 – COMMON VENT <\/td>\n<\/tr>\n
1362<\/td>\nTABLE P3107.3 COMMON VENT SIZES
TABLE P3107.3 COMMON VENT SIZES
FIGURE P3107.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL
FIGURE P3107.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL <\/td>\n<\/tr>\n
1363<\/td>\nFIGURE P3107.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS
FIGURE P3107.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS
SECTION P3108 – WET VENTING
SECTION P3108 – WET VENTING <\/td>\n<\/tr>\n
1364<\/td>\nFIGURE 3108.1(1) ACCEPTABLE FIXTURE CONNECTIONS TO WET VENTS
FIGURE 3108.1(1) ACCEPTABLE FIXTURE CONNECTIONS TO WET VENTS <\/td>\n<\/tr>\n
1365<\/td>\nFIGURE P3108.1(2) PROHIBITED FIXTURE CONNECTIONS TO WET VENTS
FIGURE P3108.1(2) PROHIBITED FIXTURE CONNECTIONS TO WET VENTS <\/td>\n<\/tr>\n
1366<\/td>\nFIGURE P3108.2.1(1) HORIZONTAL WET VENT WITH INDIVIDUAL VENT
FIGURE P3108.2.1(1) HORIZONTAL WET VENT WITH INDIVIDUAL VENT
FIGURE P3108.1(2) DRY VENT FOR COMMON VENTED BATHTUBS SERVES AS DRY VENT FOR HORIZONTAL WET VENT
FIGURE P3108.1(2) DRY VENT FOR COMMON VENTED BATHTUBS SERVES AS DRY VENT FOR HORIZONTAL WET VENT
FIGURE P3108.2.1(3) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION
FIGURE P3108.2.1(3) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION
FIGURE P3108.2.1(4) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION
FIGURE P3108.2.1(4) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION <\/td>\n<\/tr>\n
1367<\/td>\nTABLE P3108.3 WET VENT SIZE
TABLE P3108.3 WET VENT SIZE
SECTION P3109 – WASTE STACK VENT
SECTION P3109 – WASTE STACK VENT <\/td>\n<\/tr>\n
1368<\/td>\nFIGURE P3109.2 WASTE STACK VENT SYSTEM
FIGURE P3109.2 WASTE STACK VENT SYSTEM
TABLE P3109.4 WASTE STACK VENT SIZE
TABLE P3109.4 WASTE STACK VENT SIZE
SECTION P3110 – CIRCUIT VENTING
SECTION P3110 – CIRCUIT VENTING <\/td>\n<\/tr>\n
1369<\/td>\nSECTION P3111 – COMBINATION WASTE AND VENT SYSTEM
SECTION P3111 – COMBINATION WASTE AND VENT SYSTEM <\/td>\n<\/tr>\n
1370<\/td>\nFIGURE P3111.2(1) COMBINATION DRAIN AND VENT
FIGURE P3111.2(1) COMBINATION DRAIN AND VENT
FIGURE P3111.2(2) COMBINATION DRAIN AND VENT
FIGURE P3111.2(2) COMBINATION DRAIN AND VENT <\/td>\n<\/tr>\n
1371<\/td>\nFIGURE P3111.2.2 COMBINATION DRAIN AND VENT
FIGURE P3111.2.2 COMBINATION DRAIN AND VENT
TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE
TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE
SECTION P3112 – ISLAND FIXTURE VENTING
SECTION P3112 – ISLAND FIXTURE VENTING <\/td>\n<\/tr>\n
1372<\/td>\nFIGURE P3112.2 ISLAND FIXTURE VENT
FIGURE P3112.2 ISLAND FIXTURE VENT
SECTION P3113 – VENT PIPE SIZING
SECTION P3113 – VENT PIPE SIZING <\/td>\n<\/tr>\n
1373<\/td>\nFIGURE P3113.2 DEVELOPED LENGTH OF VENTS
FIGURE P3113.2 DEVELOPED LENGTH OF VENTS <\/td>\n<\/tr>\n
1374<\/td>\nSECTION P3114 – AIR ADMITTANCE VALVES
SECTION P3114 – AIR ADMITTANCE VALVES
TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS
TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS <\/td>\n<\/tr>\n
1375<\/td>\nFIGURE P3114.3(1) AIR ADMITTANCE VALVES\u2014INDIVIDUAL VENT
FIGURE P3114.3(1) AIR ADMITTANCE VALVES\u2014INDIVIDUAL VENT
FIGURE P3114.3(2) COMMON VENT
FIGURE P3114.3(2) COMMON VENT
FIGURE P3114.3(3) WET VENT
FIGURE P3114.3(3) WET VENT
FIGURE P3114.3(4) CIRCUIT VENT
FIGURE P3114.3(4) CIRCUIT VENT <\/td>\n<\/tr>\n
1376<\/td>\nFIGURE P3114.3(5) VENT CONNECTION NOT PERMITTED
FIGURE P3114.3(5) VENT CONNECTION NOT PERMITTED
FIGURE P3114.4 DISTANCE ABOVE DRAIN
FIGURE P3114.4 DISTANCE ABOVE DRAIN <\/td>\n<\/tr>\n
1377<\/td>\nFIGURE P3114.8 PROHIBITED USE OF AIR ADMITTANCE VALVE
FIGURE P3114.8 PROHIBITED USE OF AIR ADMITTANCE VALVE
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1379<\/td>\nCHAPTER 32: TRAPS
CHAPTER 32: TRAPS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P3201 – FIXTURE TRAPS
SECTION P3201 – FIXTURE TRAPS
FIGURE P3201.1(1) SLIP JOINTS IN TRAPS
FIGURE P3201.1(1) SLIP JOINTS IN TRAPS <\/td>\n<\/tr>\n
1380<\/td>\nFIGURE P3201.1(2) TRAP REQUIREMENTS
FIGURE P3201.1(2) TRAP REQUIREMENTS
FIGURE P3201.2 TRAP SUBJECT TO EVAPORATION
FIGURE P3201.2 TRAP SUBJECT TO EVAPORATION <\/td>\n<\/tr>\n
1381<\/td>\nFIGURE P3201.3 INSTALLATION OF TRAP
FIGURE P3201.3 INSTALLATION OF TRAP <\/td>\n<\/tr>\n
1382<\/td>\nTABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES
TABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES <\/td>\n<\/tr>\n
1383<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1385<\/td>\nCHAPTER 33: STORM DRAINAGE
CHAPTER 33: STORM DRAINAGE
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION P3301 – GENERAL
SECTION P3301 – GENERAL
SECTION P3302 – SUBSOIL DRAINS
SECTION P3302 – SUBSOIL DRAINS
SECTION P3303 – SUMPS AND PUMPING SYSTEMS
SECTION P3303 – SUMPS AND PUMPING SYSTEMS <\/td>\n<\/tr>\n
1386<\/td>\nFIGURE P3302.1 SUBSOIL DRAIN SUBJECT TO BACKFLOW
FIGURE P3302.1 SUBSOIL DRAIN SUBJECT TO BACKFLOW <\/td>\n<\/tr>\n
1387<\/td>\nTABLE P3302.1 SUBSOIL DRAIN PIPE
TABLE P3302.1 SUBSOIL DRAIN PIPE <\/td>\n<\/tr>\n
1389<\/td>\nPART VIII – ELECTRICAL
PART VIII – ELECTRICAL
CHAPTER 34: GENERAL REQUIREMENTS
CHAPTER 34: GENERAL REQUIREMENTS
GENERAL COMMENTS
GENERAL COMMENTS <\/td>\n<\/tr>\n
1390<\/td>\nPURPOSE
PURPOSE
SECTION E3401 – GENERAL
SECTION E3401 – GENERAL <\/td>\n<\/tr>\n
1391<\/td>\nSECTION E3402 – BUILDING STRUCTURE PROTECTION
SECTION E3402 – BUILDING STRUCTURE PROTECTION <\/td>\n<\/tr>\n
1392<\/td>\nSECTION E3403 – INSPECTION AND APPROVAL
SECTION E3403 – INSPECTION AND APPROVAL
SECTION E3404 – GENERAL EQUIPMENT REQUIREMENTS
SECTION E3404 – GENERAL EQUIPMENT REQUIREMENTS <\/td>\n<\/tr>\n
1394<\/td>\nTABLE E3404.4 ENCLOSURE SELECTION
TABLE E3404.4 ENCLOSURE SELECTION <\/td>\n<\/tr>\n
1396<\/td>\nSECTION E3405 – EQUIPMENT LOCATION AND CLEARANCES
SECTION E3405 – EQUIPMENT LOCATION AND CLEARANCES <\/td>\n<\/tr>\n
1397<\/td>\nFIGURE E3405.1 WORKING SPACE AND CLEARANCES
FIGURE E3405.1 WORKING SPACE AND CLEARANCES <\/td>\n<\/tr>\n
1399<\/td>\nSECTION E3406 – ELECTRICAL CONDUCTORS AND CONNECTIONS
SECTION E3406 – ELECTRICAL CONDUCTORS AND CONNECTIONS <\/td>\n<\/tr>\n
1402<\/td>\nFIGURE E3406.10.2 MULTIWIRE BRANCH CIRCUITS WITH SHARED NEUTRAL
FIGURE E3406.10.2 MULTIWIRE BRANCH CIRCUITS WITH SHARED NEUTRAL <\/td>\n<\/tr>\n
1403<\/td>\nFIGURE E3406.10.3 MEASURING CONDUCTOR LENGTH AT OUTLET BOX
FIGURE E3406.10.3 MEASURING CONDUCTOR LENGTH AT OUTLET BOX <\/td>\n<\/tr>\n
1404<\/td>\nSECTION E3407 – CONDUCTOR AND TERMINAL IDENTIFICATION
SECTION E3407 – CONDUCTOR AND TERMINAL IDENTIFICATION <\/td>\n<\/tr>\n
1406<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1407<\/td>\nCHAPTER 35: ELECTRICAL DEFINITIONS
CHAPTER 35: ELECTRICAL DEFINITIONS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E3501 – GENERAL
SECTION E3501 – GENERAL <\/td>\n<\/tr>\n
1412<\/td>\nFIGURE E3501(1) CONDUCTOR TERMINOLOGY
FIGURE E3501(1) CONDUCTOR TERMINOLOGY <\/td>\n<\/tr>\n
1423<\/td>\nFIGURE E3401(2) POWER SUPPLY VOLTAGES
FIGURE E3401(2) POWER SUPPLY VOLTAGES
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1425<\/td>\nCHAPTER 36: SERVICES
CHAPTER 36: SERVICES
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E3601 – GENERAL SERVICES
SECTION E3601 – GENERAL SERVICES <\/td>\n<\/tr>\n
1426<\/td>\nFIGURE E3601.3 ONE BUILDING NOT TO BE SUPPLIED THROUGH ANOTHER
FIGURE E3601.3 ONE BUILDING NOT TO BE SUPPLIED THROUGH ANOTHER <\/td>\n<\/tr>\n
1428<\/td>\nFIGURE E3601.6.2(1) METER AND MAIN DISCONNECT ON OUTSIDE OF HOUSE
FIGURE E3601.6.2(1) METER AND MAIN DISCONNECT ON OUTSIDE OF HOUSE
FIGURE E3601.6.2(2) METER ON OUTSIDE OF HOUSE; MAIN DISCONNECT ON INSIDE OF HOUSE
FIGURE E3601.6.2(2) METER ON OUTSIDE OF HOUSE; MAIN DISCONNECT ON INSIDE OF HOUSE <\/td>\n<\/tr>\n
1429<\/td>\nFIGURE E3601.7 SERVICE DISCONNECTING MEANS CONSISTING OF SIX OR FEWER SWITCHES OR CIRCUIT BREAKERS
FIGURE E3601.7 SERVICE DISCONNECTING MEANS CONSISTING OF SIX OR FEWER SWITCHES OR CIRCUIT BREAKERS
SECTION E3602 – SERVICE SIZE AND RATING
SECTION E3602 – SERVICE SIZE AND RATING <\/td>\n<\/tr>\n
1430<\/td>\nTABLE E3602.2 MINIMUM SERVICE LOAD CALCULATION
TABLE E3602.2 MINIMUM SERVICE LOAD CALCULATION <\/td>\n<\/tr>\n
1433<\/td>\nSECTION E3603 – SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING
SECTION E3603 – SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING <\/td>\n<\/tr>\n
1434<\/td>\nTABLE E3603.1 SERVICE CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR SIZING
TABLE E3603.1 SERVICE CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR SIZING <\/td>\n<\/tr>\n
1436<\/td>\nFIGURE E3603.3.3 SERVICE OVERCURRENT DEVICE INTEGRAL WITH SERVICE DISCONNECTING
FIGURE E3603.3.3 SERVICE OVERCURRENT DEVICE INTEGRAL WITH SERVICE DISCONNECTING
SECTION E3604 – OVERHEAD SERVICE-DROP AND SERVICE CONDUCTOR INSTALLATION
SECTION E3604 – OVERHEAD SERVICE-DROP AND SERVICE CONDUCTOR INSTALLATION <\/td>\n<\/tr>\n
1437<\/td>\nFIGURE E3604.1 CLEARANCES FROM BUILDING OPENINGS
FIGURE E3604.1 CLEARANCES FROM BUILDING OPENINGS <\/td>\n<\/tr>\n
1438<\/td>\nFIGURE E3604.1 CLEARANCES FROM BUILDING OPENINGS
FIGURE E3604.1 CLEARANCES FROM BUILDING OPENINGS
FIGURE E3604.2.1 CLEARANCES FROM ROOFS
FIGURE E3604.2.1 CLEARANCES FROM ROOFS <\/td>\n<\/tr>\n
1439<\/td>\nSECTION E3605 – SERVICE-ENTRANCE CONDUCTORS
SECTION E3605 – SERVICE-ENTRANCE CONDUCTORS <\/td>\n<\/tr>\n
1440<\/td>\nSECTION E3606 – SERVICE EQUIPMENT\u2014GENERAL
SECTION E3606 – SERVICE EQUIPMENT\u2014GENERAL <\/td>\n<\/tr>\n
1441<\/td>\nSECTION E3607 – SYSTEM GROUNDING
SECTION E3607 – SYSTEM GROUNDING <\/td>\n<\/tr>\n
1442<\/td>\nFIGURE E3607.2 SERVICE EQUIPMENT AND EQUIPMENT ON THE LOAD SIDE OF THE DISCONNECTING MEANS
FIGURE E3607.2 SERVICE EQUIPMENT AND EQUIPMENT ON THE LOAD SIDE OF THE DISCONNECTING MEANS <\/td>\n<\/tr>\n
1443<\/td>\nFIGURE E3607.3.1 TWO BUILDINGS SUPPLIED FROM A COMMON SERVICE
FIGURE E3607.3.1 TWO BUILDINGS SUPPLIED FROM A COMMON SERVICE <\/td>\n<\/tr>\n
1444<\/td>\nFIGURE E3607.3.2 TWO BUILDINGS SUPPLIED FROM A COMMON SERVICE
FIGURE E3607.3.2 TWO BUILDINGS SUPPLIED FROM A COMMON SERVICE <\/td>\n<\/tr>\n
1445<\/td>\nSECTION E3608 – GROUNDING ELECTRODE SYSTEM
SECTION E3608 – GROUNDING ELECTRODE SYSTEM <\/td>\n<\/tr>\n
1446<\/td>\nFIGURE E3608.1 GROUNDING ELECTRODE SYSTEM
FIGURE E3608.1 GROUNDING ELECTRODE SYSTEM <\/td>\n<\/tr>\n
1449<\/td>\nFIGURE E3608.4(1) FALL OF POTENTIAL EARTH RESISTANCE TEST SETUP
FIGURE E3608.4(1) FALL OF POTENTIAL EARTH RESISTANCE TEST SETUP <\/td>\n<\/tr>\n
1450<\/td>\nFIGURE E3608.4(2) TYPICAL GRAPH FOR FALL-OF-POTENTIAL EARTH RESISTANCE TEST
FIGURE E3608.4(2) TYPICAL GRAPH FOR FALL-OF-POTENTIAL EARTH RESISTANCE TEST
SECTION E3609 – BONDING
SECTION E3609 – BONDING <\/td>\n<\/tr>\n
1453<\/td>\nSECTION E3610 – GROUNDING ELECTRODE CONDUCTORS
SECTION E3610 – GROUNDING ELECTRODE CONDUCTORS <\/td>\n<\/tr>\n
1454<\/td>\nSECTION E3611 – GROUNDING ELECTRODE CONDUCTOR CONNECTION TO THE GROUNDING ELECTRODES
SECTION E3611 – GROUNDING ELECTRODE CONDUCTOR CONNECTION TO THE GROUNDING ELECTRODES
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1455<\/td>\nCHAPTER 37: BRANCH CIRCUIT AND FEEDER REQUIREMENTS
CHAPTER 37: BRANCH CIRCUIT AND FEEDER REQUIREMENTS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E3701 – GENERAL
SECTION E3701 – GENERAL <\/td>\n<\/tr>\n
1457<\/td>\nSECTION E3702 – BRANCH CIRCUIT RATINGS
SECTION E3702 – BRANCH CIRCUIT RATINGS <\/td>\n<\/tr>\n
1460<\/td>\nTABLE E3702.13 BRANCH-CIRCUIT REQUIREMENTS\u2014SUMMARY
TABLE E3702.13 BRANCH-CIRCUIT REQUIREMENTS\u2014SUMMARY
SECTION E3703 – REQUIRED BRANCH CIRCUITS
SECTION E3703 – REQUIRED BRANCH CIRCUITS <\/td>\n<\/tr>\n
1464<\/td>\nSECTION E3704 – FEEDER REQUIREMENTS
SECTION E3704 – FEEDER REQUIREMENTS <\/td>\n<\/tr>\n
1465<\/td>\nTABLE E3704.2(1) FEEDER LOAD CALCULATION
TABLE E3704.2(1) FEEDER LOAD CALCULATION <\/td>\n<\/tr>\n
1466<\/td>\nTABLE E3704.2(2) DEMAND LOADS FOR ELECTRIC RANGES, WALL-MOUNTED OVENS, COUNTER-MOUNTED COOKING UNITS AND OTHER COOKING APPLIANCES OVER 13\/4 kVA RATINGa
TABLE E3704.2(2) DEMAND LOADS FOR ELECTRIC RANGES, WALL-MOUNTED OVENS, COUNTER-MOUNTED COOKING UNITS AND OTHER COOKING APPLIANCES OVER 13\/4 kVA RATINGa <\/td>\n<\/tr>\n
1467<\/td>\nSECTION E3705 – CONDUCTOR SIZING AND OVERCURRENT PROTECTION
SECTION E3705 – CONDUCTOR SIZING AND OVERCURRENT PROTECTION <\/td>\n<\/tr>\n
1468<\/td>\nTABLE E3705.1 ALLOWABLE AMPACITIES
TABLE E3705.1 ALLOWABLE AMPACITIES <\/td>\n<\/tr>\n
1469<\/td>\nTABLE E3705.2 AMBIENT TEMPERATURE CORRECTION FACTORS
TABLE E3705.2 AMBIENT TEMPERATURE CORRECTION FACTORS <\/td>\n<\/tr>\n
1470<\/td>\nFIGURE E3705.3 MULTICONDUCTOR CABLES BUNDLED TOGETHER
FIGURE E3705.3 MULTICONDUCTOR CABLES BUNDLED TOGETHER <\/td>\n<\/tr>\n
1471<\/td>\nTABLE E3705.3 CONDUCTOR PROXIMITY ADJUSTMENT FACTORS
TABLE E3705.3 CONDUCTOR PROXIMITY ADJUSTMENT FACTORS <\/td>\n<\/tr>\n
1473<\/td>\nTABLE E3705.5.3 OVERCURRENT-PROTECTION RATING
TABLE E3705.5.3 OVERCURRENT-PROTECTION RATING
SECTION E3706 – PANELBOARDS
SECTION E3706 – PANELBOARDS <\/td>\n<\/tr>\n
1474<\/td>\nFIGURE E3706.2 PANELBOARD CIRCUIT IDENTIFICATION
FIGURE E3706.2 PANELBOARD CIRCUIT IDENTIFICATION <\/td>\n<\/tr>\n
1475<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1477<\/td>\nCHAPTER 38: WIRING METHODS
CHAPTER 38: WIRING METHODS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E3801 – GENERAL REQUIREMENTS
SECTION E3801 – GENERAL REQUIREMENTS
TABLE E3801.2 ALLOWABLE WIRING METHODS
TABLE E3801.2 ALLOWABLE WIRING METHODS <\/td>\n<\/tr>\n
1478<\/td>\nTABLE E3801.4 ALLOWABLE APPLICATIONS FOR WIRING METHODS
TABLE E3801.4 ALLOWABLE APPLICATIONS FOR WIRING METHODS <\/td>\n<\/tr>\n
1479<\/td>\nSECTION E3802 – ABOVE-GROUND INSTALLATION REQUIREMENTS
SECTION E3802 – ABOVE-GROUND INSTALLATION REQUIREMENTS <\/td>\n<\/tr>\n
1480<\/td>\nTABLE E3802.1 GENERAL INSTALLATION AND SUPPORT REQUIREMENTS FOR WIRING METHODS
TABLE E3802.1 GENERAL INSTALLATION AND SUPPORT REQUIREMENTS FOR WIRING METHODS <\/td>\n<\/tr>\n
1481<\/td>\nFIGURE E3802.1 CABLES HELD 1 1\/4 INCHES BACK FROM EDGE OF FRAMING MEMBER
FIGURE E3802.1 CABLES HELD 1 1\/4 INCHES BACK FROM EDGE OF FRAMING MEMBER <\/td>\n<\/tr>\n
1482<\/td>\nFIGURE E3802.3.1(1) PROHIBITED APPLICATION OF TYPE NM CABLE
FIGURE E3802.3.1(1) PROHIBITED APPLICATION OF TYPE NM CABLE <\/td>\n<\/tr>\n
1483<\/td>\nFIGURE E3802.3.1(2) PROHIBITED APPLICATION OF TYPE NM CABLE
FIGURE E3802.3.1(2) PROHIBITED APPLICATION OF TYPE NM CABLE
FIGURE E3802.4 PROHIBITED INSTALLATION OF TYPE MM CABLE ACROSS THE BOTTOM OF FLOOR JOISTS
FIGURE E3802.4 PROHIBITED INSTALLATION OF TYPE MM CABLE ACROSS THE BOTTOM OF FLOOR JOISTS <\/td>\n<\/tr>\n
1484<\/td>\nSECTION E3803 – UNDERGROUND INSTALLATION REQUIREMENTS
SECTION E3803 – UNDERGROUND INSTALLATION REQUIREMENTS <\/td>\n<\/tr>\n
1485<\/td>\nTABLE E3803.1 MINIMUM COVER REQUIREMENTS, BURIAL IN INCHES
TABLE E3803.1 MINIMUM COVER REQUIREMENTS, BURIAL IN INCHES <\/td>\n<\/tr>\n
1486<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1487<\/td>\nCHAPTER 39: POWER AND LIGHTING DISTRIBUTION
CHAPTER 39: POWER AND LIGHTING DISTRIBUTION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E3901 – RECEPTACLE OUTLETS
SECTION E3901 – RECEPTACLE OUTLETS <\/td>\n<\/tr>\n
1488<\/td>\nFIGURE E3901.2 GENERAL USE RECEPTACLE DISTRIBUTION
FIGURE E3901.2 GENERAL USE RECEPTACLE DISTRIBUTION <\/td>\n<\/tr>\n
1489<\/td>\nFIGURE E3901.4 COUNTERTOP RECEPTACLES
FIGURE E3901.4 COUNTERTOP RECEPTACLES <\/td>\n<\/tr>\n
1490<\/td>\nFIGURE E3901.4.1 DETERMINATION OF AREA BEHIND SINK OR RANGE
FIGURE E3901.4.1 DETERMINATION OF AREA BEHIND SINK OR RANGE <\/td>\n<\/tr>\n
1491<\/td>\nFIGURE E3901.4.2 ISLAND WITH TWO COUNTER SPACES
FIGURE E3901.4.2 ISLAND WITH TWO COUNTER SPACES <\/td>\n<\/tr>\n
1493<\/td>\nSECTION E3902 – GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
SECTION E3902 – GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
FIGURE E3902.1 BASIC PRINCIPLES OF OPERATION OF GFCI RECEPTACLE DEVICE AND DEVICE TESTER
FIGURE E3902.1 BASIC PRINCIPLES OF OPERATION OF GFCI RECEPTACLE DEVICE AND DEVICE TESTER <\/td>\n<\/tr>\n
1495<\/td>\nFIGURE E3902.12 AFCI TYPE CIRCUIT BREAKER
FIGURE E3902.12 AFCI TYPE CIRCUIT BREAKER <\/td>\n<\/tr>\n
1496<\/td>\nSECTION E3903 – LIGHTING OUTLETS
SECTION E3903 – LIGHTING OUTLETS
SECTION E3904 – GENERAL INSTALLATION REQUIREMENTS
SECTION E3904 – GENERAL INSTALLATION REQUIREMENTS <\/td>\n<\/tr>\n
1498<\/td>\nTABLE E3904.6(1) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT)
TABLE E3904.6(1) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METALLIC TUBING (EMT) <\/td>\n<\/tr>\n
1499<\/td>\nTABLE E3904.6(2) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL NONMETALLIC TUBING (ENT)a
TABLE E3904.6(2) MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL NONMETALLIC TUBING (ENT)a <\/td>\n<\/tr>\n
1500<\/td>\nTABLE E3904.6(3) MAXIMUM NUMBER OF CONDUCTORS IN FLEXIBLE METALLIC CONDUIT (FMC)a
TABLE E3904.6(3) MAXIMUM NUMBER OF CONDUCTORS IN FLEXIBLE METALLIC CONDUIT (FMC)a <\/td>\n<\/tr>\n
1501<\/td>\nTABLE E3904.6(4) MAXIMUM NUMBER OF CONDUCTORS IN INTERMEDIATE METALLIC CONDUIT (IMC)a
TABLE E3904.6(4) MAXIMUM NUMBER OF CONDUCTORS IN INTERMEDIATE METALLIC CONDUIT (IMC)a <\/td>\n<\/tr>\n
1502<\/td>\nTABLE E3904.6(5) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-B)a
TABLE E3904.6(5) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-B)a <\/td>\n<\/tr>\n
1503<\/td>\nTABLE E3904.6(6) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-A)a
TABLE E3904.6(6) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE NONMETALLIC CONDUIT (FNMC-A)a <\/td>\n<\/tr>\n
1504<\/td>\nTABLE E3904.6(7) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC)a
TABLE E3904.6(7) MAXIMUM NUMBER OF CONDUCTORS IN LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC)a <\/td>\n<\/tr>\n
1505<\/td>\nTABLE E3904.6(8) MAXIMUM NUMBER OF CONDUCTORS IN RIGID METAL CONDUIT (RMC)a
TABLE E3904.6(8) MAXIMUM NUMBER OF CONDUCTORS IN RIGID METAL CONDUIT (RMC)a <\/td>\n<\/tr>\n
1506<\/td>\nTABLE E3904.6(9) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a
TABLE E3904.6(9) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT, SCHEDULE 80 (PVC-80)a <\/td>\n<\/tr>\n
1507<\/td>\nTABLE E3904.6(10) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT SCHEDULE 40 (PVC-40)a
TABLE E3904.6(10) MAXIMUM NUMBER OF CONDUCTORS IN RIGID PVC CONDUIT SCHEDULE 40 (PVC-40)a <\/td>\n<\/tr>\n
1508<\/td>\nSECTION E3905 – BOXES, CONDUIT BODIES AND FITTINGS
SECTION E3905 – BOXES, CONDUIT BODIES AND FITTINGS <\/td>\n<\/tr>\n
1513<\/td>\nTABLE E3905.13.1 MAXIMUM NUMBER OF CONDUCTORS IN METAL BOXE
TABLE E3905.13.1 MAXIMUM NUMBER OF CONDUCTORS IN METAL BOXE <\/td>\n<\/tr>\n
1514<\/td>\nTABLE E3905.13.2.1 VOLUME ALLOWANCE REQUIRED PER CONDUCTOR
TABLE E3905.13.2.1 VOLUME ALLOWANCE REQUIRED PER CONDUCTOR
SECTION E3906 – INSTALLATION OF BOXES, CONDUIT BODIES AND FITTINGS
SECTION E3906 – INSTALLATION OF BOXES, CONDUIT BODIES AND FITTINGS <\/td>\n<\/tr>\n
1517<\/td>\nSECTION E3907 – CABINETS AND PANELBOARDS
SECTION E3907 – CABINETS AND PANELBOARDS <\/td>\n<\/tr>\n
1519<\/td>\nTABLE E3907.8 PERCENT OF CROSS SECTION OF CONDUIT AND TUBING FOR CONDUCTORS
TABLE E3907.8 PERCENT OF CROSS SECTION OF CONDUIT AND TUBING FOR CONDUCTORS
FIGURE E3907.8 CABLES SECURED TO PANELBOARD ENCLOSURES
FIGURE E3907.8 CABLES SECURED TO PANELBOARD ENCLOSURES
SECTION E3908 – GROUNDING
SECTION E3908 – GROUNDING <\/td>\n<\/tr>\n
1521<\/td>\nFIGURE E3908.7 PROHIBITED USE OF GROUNDED CIRCUIT CONDUCTOR
FIGURE E3908.7 PROHIBITED USE OF GROUNDED CIRCUIT CONDUCTOR <\/td>\n<\/tr>\n
1523<\/td>\nTABLE E3908.12 EQUIPMENT GROUNDING CONDUCTOR SIZING
TABLE E3908.12 EQUIPMENT GROUNDING CONDUCTOR SIZING <\/td>\n<\/tr>\n
1524<\/td>\nSECTION E3909 – FLEXIBLE CORDS
SECTION E3909 – FLEXIBLE CORDS <\/td>\n<\/tr>\n
1525<\/td>\nTABLE E3909.2 MAXIMUM AMPERE LOAD FOR FLEXIBLE CORDS
TABLE E3909.2 MAXIMUM AMPERE LOAD FOR FLEXIBLE CORDS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1527<\/td>\nCHAPTER 40: DEVICES AND LUMINAIRES
CHAPTER 40: DEVICES AND LUMINAIRES
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E4001 – SWITCHES
SECTION E4001 – SWITCHES <\/td>\n<\/tr>\n
1529<\/td>\nSECTION E4002 – RECEPTACLES
SECTION E4002 – RECEPTACLES <\/td>\n<\/tr>\n
1530<\/td>\nTABLE E4002.1.2 RECEPTACLE RATINGS FOR VARIOUS SIZE MULTI-OUTLET CIRCUITS
TABLE E4002.1.2 RECEPTACLE RATINGS FOR VARIOUS SIZE MULTI-OUTLET CIRCUITS <\/td>\n<\/tr>\n
1532<\/td>\nFIGURE E4002.14 TYPICAL TAMPER-RESISTANT RECEPTACLE
FIGURE E4002.14 TYPICAL TAMPER-RESISTANT RECEPTACLE
SECTION E4003 – FIXTURES
SECTION E4003 – FIXTURES <\/td>\n<\/tr>\n
1534<\/td>\nFIGURE E4003.12 CLOSET STORAGE SPACE
FIGURE E4003.12 CLOSET STORAGE SPACE <\/td>\n<\/tr>\n
1535<\/td>\nSECTION E4004 – LUMINAIRE INSTALLATION
SECTION E4004 – LUMINAIRE INSTALLATION <\/td>\n<\/tr>\n
1536<\/td>\nSECTION E4005 – TRACK LIGHTING
SECTION E4005 – TRACK LIGHTING <\/td>\n<\/tr>\n
1537<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1539<\/td>\nCHAPTER 41: APPLIANCE INSTALLATION
CHAPTER 41: APPLIANCE INSTALLATION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E4101 – GENERAL
SECTION E4101 – GENERAL
TABLE E4101.3 FLEXIBLE CORD LENGTH
TABLE E4101.3 FLEXIBLE CORD LENGTH <\/td>\n<\/tr>\n
1540<\/td>\nFIGURE E4101.5 TYPICAL APPLIANCE DISCONNECTING MEANS
FIGURE E4101.5 TYPICAL APPLIANCE DISCONNECTING MEANS <\/td>\n<\/tr>\n
1541<\/td>\nTABLE E4101.5 DISCONNECTING MEANS
TABLE E4101.5 DISCONNECTING MEANS <\/td>\n<\/tr>\n
1542<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1543<\/td>\nCHAPTER 42: SWIMMING POOLS
CHAPTER 42: SWIMMING POOLS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E4201 – GENERAL
SECTION E4201 – GENERAL <\/td>\n<\/tr>\n
1545<\/td>\nSECTION E4202 – WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS
SECTION E4202 – WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS
TABLE E4202.1 ALLOWABLE APPLICATIONS FOR WIRING METHODS
TABLE E4202.1 ALLOWABLE APPLICATIONS FOR WIRING METHODS <\/td>\n<\/tr>\n
1546<\/td>\nSECTION E4203 – EQUIPMENT LOCATION AND CLEARANCES
SECTION E4203 – EQUIPMENT LOCATION AND CLEARANCES <\/td>\n<\/tr>\n
1549<\/td>\nTABLE E4203.5 OVERHEAD CONDUCTOR CLEARANCES
TABLE E4203.5 OVERHEAD CONDUCTOR CLEARANCES
SECTION E4204 – BONDING
SECTION E4204 – BONDING <\/td>\n<\/tr>\n
1550<\/td>\nTABLE E4203.7 MINIMUM BURIAL DEPTHS
TABLE E4203.7 MINIMUM BURIAL DEPTHS <\/td>\n<\/tr>\n
1552<\/td>\nSECTION E4205 – GROUNDING
SECTION E4205 – GROUNDING <\/td>\n<\/tr>\n
1554<\/td>\nSECTION E4206 – EQUIPMENT INSTALLATION
SECTION E4206 – EQUIPMENT INSTALLATION <\/td>\n<\/tr>\n
1557<\/td>\nSECTION E4207 – STORABLE SWIMMING POOLS
SECTION E4207 – STORABLE SWIMMING POOLS <\/td>\n<\/tr>\n
1558<\/td>\nSECTION E4208 – SPAS AND HOT TUBS
SECTION E4208 – SPAS AND HOT TUBS <\/td>\n<\/tr>\n
1559<\/td>\nSECTION E4209 – HYDROMASSAGE BATHTUBS
SECTION E4209 – HYDROMASSAGE BATHTUBS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1561<\/td>\nCHAPTER 43: CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS
CHAPTER 43: CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION E4301 – GENERAL
SECTION E4301 – GENERAL
SECTION E4302 – POWER SOURCES
SECTION E4302 – POWER SOURCES <\/td>\n<\/tr>\n
1562<\/td>\nSECTION E4303 – WIRING METHODS
SECTION E4303 – WIRING METHODS
TABLE E4303.2 CABLE USES AND PERMITTED SUBSTITUTI
TABLE E4303.2 CABLE USES AND PERMITTED SUBSTITUTI <\/td>\n<\/tr>\n
1563<\/td>\nSECTION E4304 – INSTALLATION REQUIREMENTS
SECTION E4304 – INSTALLATION REQUIREMENTS <\/td>\n<\/tr>\n
1564<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1565<\/td>\nPART IX – REFERENCED STANDARDS
PART IX – REFERENCED STANDARDS
CHAPTER 44: REFERENCED STANDARDS
CHAPTER 44: REFERENCED STANDARDS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE <\/td>\n<\/tr>\n
1566<\/td>\nFIGURE 44 REFERENCE STANDARDS
FIGURE 44 REFERENCE STANDARDS <\/td>\n<\/tr>\n
1567<\/td>\nAAMA
AAMA
ACI
ACI
ACCA
ACCA
AFPA
AFPA
AISI
AISI <\/td>\n<\/tr>\n
1568<\/td>\nAITC
AITC
ANSI
ANSI <\/td>\n<\/tr>\n
1569<\/td>\nAPA
APA
APSP
APSP
ASCE\/SEI
ASCE\/SEI <\/td>\n<\/tr>\n
1570<\/td>\nASHRAE
ASHRAE
ASME
ASME <\/td>\n<\/tr>\n
1571<\/td>\nASSE
ASSE <\/td>\n<\/tr>\n
1572<\/td>\nASTM
ASTM <\/td>\n<\/tr>\n
1579<\/td>\nAWPA
AWPA
AWS
AWS <\/td>\n<\/tr>\n
1580<\/td>\nAWWA
AWWA
CGSB
CGSB
CISPI
CISPI
CPA
CPA
CPSC
CPSC <\/td>\n<\/tr>\n
1581<\/td>\nCSA
CSA <\/td>\n<\/tr>\n
1582<\/td>\nCSSB
CSSB
DASMA
DASMA
DOC
DOC
DOTn
DOTn
FEMA
FEMA <\/td>\n<\/tr>\n
1583<\/td>\nFM
FM
GA
GA
HPVA
HPVA
ICC
ICC
ISO
ISO <\/td>\n<\/tr>\n
1584<\/td>\nMSS
MSS
NAIMA
NAIMA
NCMA
NCMA
NFPA
NFPA
NFRC
NFRC <\/td>\n<\/tr>\n
1585<\/td>\nNSF
NSF
PCA
PCA
SMACNA
SMACNA
TMS
TMS
TPI
TPI <\/td>\n<\/tr>\n
1586<\/td>\nUL
UL <\/td>\n<\/tr>\n
1587<\/td>\nULC
ULC
US-FTC
US-FTC
WDMA
WDMA <\/td>\n<\/tr>\n
1589<\/td>\nAPPENDIX A – SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A – SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
A.2 DESCRIPTION OF TABLES <\/td>\n<\/tr>\n
1590<\/td>\nTABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES <\/td>\n<\/tr>\n
1591<\/td>\nTABLE A.2.2\u2014continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
TABLE A.2.2\u2014continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES <\/td>\n<\/tr>\n
1592<\/td>\nTABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES G2413.4(1)THROUGH G2413.4(8) WHERE THE SPECIFIC GRAVITYOF THE GAS IS OTHER THAN 0.60
TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES G2413.4(1)THROUGH G2413.4(8) WHERE THE SPECIFIC GRAVITYOF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
A.3 USE OF CAPACITY TABLES <\/td>\n<\/tr>\n
1594<\/td>\nTABLE A.3.4 THOUSANDS OF Btu\/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
TABLE A.3.4 THOUSANDS OF Btu\/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
A.4 USE OF SIZING EQUATIONS
A.5 PIPE AND TUBE DIAMETERS
A.5 PIPE AND TUBE DIAMETERS <\/td>\n<\/tr>\n
1595<\/td>\nTABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 USE OF SIZING CHARTS
A.6 USE OF SIZING CHARTS <\/td>\n<\/tr>\n
1596<\/td>\nFIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
FIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC)
FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above)
FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above) <\/td>\n<\/tr>\n
1597<\/td>\nA.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
A.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM
FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM <\/td>\n<\/tr>\n
1598<\/td>\nFIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM <\/td>\n<\/tr>\n
1599<\/td>\nFIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYST
FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYST <\/td>\n<\/tr>\n
1601<\/td>\nAPPENDIX B – SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
APPENDIX B – SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR <\/td>\n<\/tr>\n
1602<\/td>\nFIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE BDOUBLE-WALL VENT CONNECTOR
FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE BDOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR <\/td>\n<\/tr>\n
1603<\/td>\nFIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES <\/td>\n<\/tr>\n
1604<\/td>\nFIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
FIGURE B-14 MULTISTORY VENT SYSTEMS <\/td>\n<\/tr>\n
1605<\/td>\nFIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE <\/td>\n<\/tr>\n
1606<\/td>\nEXAMPLES USING COMMON VENTING TABLES
EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT <\/td>\n<\/tr>\n
1608<\/td>\nTABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa <\/td>\n<\/tr>\n
1609<\/td>\nFIGURE B-19
FIGURE B-19 <\/td>\n<\/tr>\n
1611<\/td>\nAPPENDIX C – EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C – EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
FIGURE C-1 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
FIGURE C-1 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS <\/td>\n<\/tr>\n
1613<\/td>\nAPPENDIX D – RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
APPENDIX D – RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION <\/td>\n<\/tr>\n
1615<\/td>\nAPPENDIX E – MANUFACTURED HOUSING USED AS DWELLINGS
APPENDIX E – MANUFACTURED HOUSING USED AS DWELLINGS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AE101 – SCOPE
SECTION AE101 – SCOPE <\/td>\n<\/tr>\n
1616<\/td>\nSECTION AE102 – APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT
SECTION AE102 – APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT <\/td>\n<\/tr>\n
1617<\/td>\nSECTION AE201 – DEFINITIONS
SECTION AE201 – DEFINITIONS
SECTION AE301 – PERMITS
SECTION AE301 – PERMITS <\/td>\n<\/tr>\n
1618<\/td>\nSECTION AE302 – APPLICATION FOR PERMIT
SECTION AE302 – APPLICATION FOR PERMIT
SECTION AE303 – PERMITS ISSUANCE
SECTION AE303 – PERMITS ISSUANCE <\/td>\n<\/tr>\n
1619<\/td>\nSECTION AE304 – FEES
SECTION AE304 – FEES <\/td>\n<\/tr>\n
1620<\/td>\nSECTION AE305 – INSPECTIONS
SECTION AE305 – INSPECTIONS <\/td>\n<\/tr>\n
1622<\/td>\nSECTION AE306 – SPECIAL INSPECTIONS
SECTION AE306 – SPECIAL INSPECTIONS
SECTION AE307 – UTILITY SERVICE
SECTION AE307 – UTILITY SERVICE
SECTION AE401 – OCCUPANCY CLASSIFICATION
SECTION AE401 – OCCUPANCY CLASSIFICATION
SECTION AE40 2LOCATION ON PROPERTY
SECTION AE40 2LOCATION ON PROPERTY
SECTION AE501 – DESIGN
SECTION AE501 – DESIGN <\/td>\n<\/tr>\n
1623<\/td>\nSECTION AE502 – FOUNDATION SYSTEMS
SECTION AE502 – FOUNDATION SYSTEMS
SECTION AE503 – SKIRTING AND PERIMETER ENCLOSURES
SECTION AE503 – SKIRTING AND PERIMETER ENCLOSURES <\/td>\n<\/tr>\n
1624<\/td>\nSECTION AE504 – STRUCTURAL ADDITIONS
SECTION AE504 – STRUCTURAL ADDITIONS
SECTION AE505 – BUILDING SERVICE EQUIPMENT
SECTION AE505 – BUILDING SERVICE EQUIPMENT
SECTION AE506 – EXITS
SECTION AE506 – EXITS
SECTION AE507 – OCCUPANCY, FIRE SAFETY AND ENERGY CONSERVATION STANDARDS
SECTION AE507 – OCCUPANCY, FIRE SAFETY AND ENERGY CONSERVATION STANDARDS
SECTION AE600 – SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS
SECTION AE600 – SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS
SECTION AE601 – FOOTINGS AND FOUNDATIONS
SECTION AE601 – FOOTINGS AND FOUNDATIONS <\/td>\n<\/tr>\n
1625<\/td>\nSECTION AE602 – PIER CONSTRUCTION
SECTION AE602 – PIER CONSTRUCTION
SECTION AE603 – HEIGHT OF PIERS
SECTION AE603 – HEIGHT OF PIERS
SECTION AE604 – ANCHORAGE INSTALLATIONS
SECTION AE604 – ANCHORAGE INSTALLATIONS <\/td>\n<\/tr>\n
1626<\/td>\nSECTION AE605 – TIES, MATERIALS AND INSTALLATION
SECTION AE605 – TIES, MATERIALS AND INSTALLATION
SECTION AE606 – REFERENCED STANDARDS
SECTION AE606 – REFERENCED STANDARDS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1629<\/td>\nAPPENDIX F – RADON CONTROL METHODS
APPENDIX F – RADON CONTROL METHODS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AF101 – SCOPE
SECTION AF101 – SCOPE
SECTION AF102 – DEFINITIONS
SECTION AF102 – DEFINITIONS <\/td>\n<\/tr>\n
1630<\/td>\nSECTION AF103 – REQUIREMENTS
SECTION AF103 – REQUIREMENTS <\/td>\n<\/tr>\n
1634<\/td>\nFIGURE AF101 – EPA MAP OF RADON ZONES
FIGURE AF101 – EPA MAP OF RADON ZONES <\/td>\n<\/tr>\n
1635<\/td>\nTABLE AF101(1) HIGH RADON POTENTIAL (ZONE 1) COUNTIESa
TABLE AF101(1) HIGH RADON POTENTIAL (ZONE 1) COUNTIESa <\/td>\n<\/tr>\n
1636<\/td>\nTABLE AF101(1)\u2014continued HIGH RADON POTENTIAL (ZONE 1) COUNTIESa
TABLE AF101(1)\u2014continued HIGH RADON POTENTIAL (ZONE 1) COUNTIESa <\/td>\n<\/tr>\n
1637<\/td>\nFIGURE AF102 -RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES
FIGURE AF102 -RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES <\/td>\n<\/tr>\n
1639<\/td>\nAPPENDIX G – SWIMMING POOLS, SPAS AND HOT TUBS
APPENDIX G – SWIMMING POOLS, SPAS AND HOT TUBS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AG101 – GENERAL
SECTION AG101 – GENERAL <\/td>\n<\/tr>\n
1640<\/td>\nSECTION AG102 – DEFINITIONS
SECTION AG102 – DEFINITIONS <\/td>\n<\/tr>\n
1641<\/td>\nSECTION AG103 – SWIMMING POOLS
SECTION AG103 – SWIMMING POOLS
SECTION AG104 – SPAS AND HOT TUBS
SECTION AG104 – SPAS AND HOT TUBS
SECTION AG105 – BARRIER REQUIREMENTS
SECTION AG105 – BARRIER REQUIREMENTS <\/td>\n<\/tr>\n
1642<\/td>\nFIGURE AG105.2(1) OPENING LIMITATIONS
FIGURE AG105.2(1) OPENING LIMITATIONS <\/td>\n<\/tr>\n
1643<\/td>\nFIGURE AG105.2(2) PRIVATE SWIMMING POOL BARRIER CONSTRUCTION
FIGURE AG105.2(2) PRIVATE SWIMMING POOL BARRIER CONSTRUCTION <\/td>\n<\/tr>\n
1644<\/td>\nFIGURE AG105.2(3) CHAIN-LINK FENCE MESH FOR PRIVATE SWIMMING POOLS
FIGURE AG105.2(3) CHAIN-LINK FENCE MESH FOR PRIVATE SWIMMING POOLS <\/td>\n<\/tr>\n
1645<\/td>\nSECTION AG106 – ENTRAPMENT PROTECTION FOR SWIMMING POOL AND SPA SUCTION OUTLETS
SECTION AG106 – ENTRAPMENT PROTECTION FOR SWIMMING POOL AND SPA SUCTION OUTLETS
SECTION AG107 – ABBREVIATIONS
SECTION AG107 – ABBREVIATIONS
SECTION AG108 – STANDARDS
SECTION AG108 – STANDARDS <\/td>\n<\/tr>\n
1647<\/td>\nAPPENDIX H – PATIO COVERS
APPENDIX H – PATIO COVERS
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AH101 – GENERAL
SECTION AH101 – GENERAL
SECTION AH102 – DEFINITION
SECTION AH102 – DEFINITION
SECTION AH103 – PERMITTED USES
SECTION AH103 – PERMITTED USES
SECTION AH104 – DESIGN LOADS
SECTION AH104 – DESIGN LOADS <\/td>\n<\/tr>\n
1648<\/td>\nSECTION AH105 – LIGHT AND VENTILATION\/EMERGENCY EGRESS
SECTION AH105 – LIGHT AND VENTILATION\/EMERGENCY EGRESS
SECTION AH106 – FOOTINGS
SECTION AH106 – FOOTINGS
SECTION AH107 – SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
SECTION AH107 – SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS <\/td>\n<\/tr>\n
1649<\/td>\nTABLE AH107.4(1) DESIGN WIND PRESSURES FOR ALUMINUM SCREEN ENCLOSURE FRAMING WITH AN IMPORTANCE FACTOR OF
TABLE AH107.4(1) DESIGN WIND PRESSURES FOR ALUMINUM SCREEN ENCLOSURE FRAMING WITH AN IMPORTANCE FACTOR OF <\/td>\n<\/tr>\n
1650<\/td>\nTABLE AH107.4(2) HEIGHT ADJUSTMENT FACTORS
TABLE AH107.4(2) HEIGHT ADJUSTMENT FACTORS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1651<\/td>\nAPPENDIX I – PRIVATE SEWAGE DISPOSAL
APPENDIX I – PRIVATE SEWAGE DISPOSAL
SECTION AI101 – GENERAL
SECTION AI101 – GENERAL <\/td>\n<\/tr>\n
1653<\/td>\nAPPENDIX J – EXISTING BUILDINGS AND STRUCTURES
APPENDIX J – EXISTING BUILDINGS AND STRUCTURES
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AJ101 – PURPOSE AND INTENT
SECTION AJ101 – PURPOSE AND INTENT <\/td>\n<\/tr>\n
1654<\/td>\nSECTION AJ102 – COMPLIANCE
SECTION AJ102 – COMPLIANCE <\/td>\n<\/tr>\n
1655<\/td>\nSECTION AJ103 – PRELIMINARY MEETING
SECTION AJ103 – PRELIMINARY MEETING
SECTION AJ104 – EVALUATION OF AN EXISTING BUILDING
SECTION AJ104 – EVALUATION OF AN EXISTING BUILDING <\/td>\n<\/tr>\n
1656<\/td>\nSECTION AJ105 – PERMIT
SECTION AJ105 – PERMIT
SECTION AJ201 – DEFINITIONS
SECTION AJ201 – DEFINITIONS <\/td>\n<\/tr>\n
1657<\/td>\nSECTION AJ301 – REPAIRS
SECTION AJ301 – REPAIRS <\/td>\n<\/tr>\n
1658<\/td>\nSECTION AJ401 – RENOVATIONS
SECTION AJ401 – RENOVATIONS <\/td>\n<\/tr>\n
1659<\/td>\nSECTION AJ501 – ALTERATIONS
SECTION AJ501 – ALTERATIONS <\/td>\n<\/tr>\n
1661<\/td>\nSECTION AJ601 – RECONSTRUCTION
SECTION AJ601 – RECONSTRUCTION <\/td>\n<\/tr>\n
1662<\/td>\nBIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1663<\/td>\nAPPENDIX K – SOUND TRANSMISSION
APPENDIX K – SOUND TRANSMISSION
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AK101 – GENERAL
SECTION AK101 – GENERAL
SECTION AK102 – AIR-BORNE SOUND
SECTION AK102 – AIR-BORNE SOUND <\/td>\n<\/tr>\n
1664<\/td>\nSECTION AK103 – STRUCTURAL-BORNE SOUND
SECTION AK103 – STRUCTURAL-BORNE SOUND
SECTION AK104 – REFERENCED STANDARDS
SECTION AK104 – REFERENCED STANDARDS
BIBLIOGRAPHY
BIBLIOGRAPHY <\/td>\n<\/tr>\n
1665<\/td>\nAPPENDIX L – PERMIT FEES
APPENDIX L – PERMIT FEES <\/td>\n<\/tr>\n
1667<\/td>\nAPPENDIX M – HOME DAY CARE\u2014R-3 OCCUPANCY
APPENDIX M – HOME DAY CARE\u2014R-3 OCCUPANCY
GENERAL COMMENTS
GENERAL COMMENTS
PURPOSE
PURPOSE
SECTION AM101 – GENERAL
SECTION AM101 – GENERAL
SECTION AM102 – DEFINITIONS
SECTION AM102 – DEFINITIONS
SECTION AM103 – MEANS OF EGRESS
SECTION AM103 – MEANS OF EGRESS <\/td>\n<\/tr>\n
1668<\/td>\nSECTION AM104 – SMOKE DETECTION
SECTION AM104 – SMOKE DETECTION <\/td>\n<\/tr>\n
1669<\/td>\nAPPENDIX N – VENTING METHODS
APPENDIX N – VENTING METHODS
FIGURE N1 TYPICAL SINGLE-BATH WET-VENT ARRANGEMENTS
FIGURE N1 TYPICAL SINGLE-BATH WET-VENT ARRANGEMENTS <\/td>\n<\/tr>\n
1670<\/td>\nFIGURE N2 TYPICAL DOUBLE-BATH WET-VENT ARRANGEMENTS
FIGURE N2 TYPICAL DOUBLE-BATH WET-VENT ARRANGEMENTS <\/td>\n<\/tr>\n
1671<\/td>\nFIGURE N3 TYPICAL HORIZONTAL WET VENTING
FIGURE N3 TYPICAL HORIZONTAL WET VENTING <\/td>\n<\/tr>\n
1672<\/td>\nFIGURE N4 TYPICAL METHODS OF WET VENTING
FIGURE N4 TYPICAL METHODS OF WET VENTING <\/td>\n<\/tr>\n
1673<\/td>\nFIGURE N5 SINGLE STACK SYSTEM FOR A TWO-STORY DWELLING
FIGURE N5 SINGLE STACK SYSTEM FOR A TWO-STORY DWELLING <\/td>\n<\/tr>\n
1674<\/td>\nFIGURE N6 WASTE STACK VENTING
FIGURE N6 WASTE STACK VENTING <\/td>\n<\/tr>\n
1675<\/td>\nFIGURE N7 CIRCUIT VENT WITH ADDITIONAL NONCIRCUIT VENTED BRANCH
FIGURE N7 CIRCUIT VENT WITH ADDITIONAL NONCIRCUIT VENTED BRANCH <\/td>\n<\/tr>\n
1677<\/td>\nAPPENDIX O – GRAY WATER RECYCLING SYSTEMS
APPENDIX O – GRAY WATER RECYCLING SYSTEMS
SECTION AO101 – GENERAL
SECTION AO101 – GENERAL
SECTION AO102 – SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS
SECTION AO102 – SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS <\/td>\n<\/tr>\n
1678<\/td>\nFIGURE AO101.1(1) GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS
FIGURE AO101.1(1) GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS
FIGURE AO101.1(2) GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION
FIGURE AO101.1(2) GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION <\/td>\n<\/tr>\n
1679<\/td>\nSECTION AO103 – SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
SECTION AO103 – SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
EQUATION AO-1
EQUATION AO-1 <\/td>\n<\/tr>\n
1680<\/td>\nTABLE AO103.8 LOCATION OF GRAY WATER SYSTEM
TABLE AO103.8 LOCATION OF GRAY WATER SYSTEM
TABLE AO103.9.1 DESIGN LOADING RATE
TABLE AO103.9.1 DESIGN LOADING RATE <\/td>\n<\/tr>\n
1681<\/td>\nTABLE AO103.10 DISTRIBUTION PIPE
TABLE AO103.10 DISTRIBUTION PIPE <\/td>\n<\/tr>\n
1683<\/td>\nAPPENDIX P – SIZING OF WATER PIPING SYSTEM
APPENDIX P – SIZING OF WATER PIPING SYSTEM
SECTION AP101 – GENERAL
SECTION AP101 – GENERAL
SECTION AP102 – INFORMATION REQUIRED
SECTION AP102 – INFORMATION REQUIRED
SECTION AP103 – SELECTION OF PIPE SIZE
SECTION AP103 – SELECTION OF PIPE SIZE <\/td>\n<\/tr>\n
1687<\/td>\nTABLE AP.1
TABLE AP.1
TABLE AP.2
TABLE AP.2 <\/td>\n<\/tr>\n
1688<\/td>\nFIGURE AP103.3(1) EXAMPLE-SIZING
FIGURE AP103.3(1) EXAMPLE-SIZING <\/td>\n<\/tr>\n
1689<\/td>\nTABLE AP103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBL
TABLE AP103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBL <\/td>\n<\/tr>\n
1690<\/td>\nTABLE AP103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
TABLE AP103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa <\/td>\n<\/tr>\n
1691<\/td>\nTABLE AP103.3(3) TABLE FOR ESTIMATING DEMAND
TABLE AP103.3(3) TABLE FOR ESTIMATING DEMAND <\/td>\n<\/tr>\n
1692<\/td>\nTABLE AP103.3(3)\u2014continued TABLE FOR ESTIMATING DEMAND
TABLE AP103.3(3)\u2014continued TABLE FOR ESTIMATING DEMAND
TABLE AP103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
TABLE AP103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) <\/td>\n<\/tr>\n
1693<\/td>\nTABLE AP103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE AP103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE AP103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
TABLE AP103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet) <\/td>\n<\/tr>\n
1694<\/td>\nFIGURE AP103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
FIGURE AP103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING) <\/td>\n<\/tr>\n
1695<\/td>\nFIGURE AP103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
FIGURE AP103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING) <\/td>\n<\/tr>\n
1696<\/td>\nFIGURE AP103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING)
FIGURE AP103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING) <\/td>\n<\/tr>\n
1697<\/td>\nFIGURE AP103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
FIGURE AP103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa <\/td>\n<\/tr>\n
1698<\/td>\nFIGURE AP103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
FIGURE AP103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa <\/td>\n<\/tr>\n
1699<\/td>\nFIGURE AP103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa
FIGURE AP103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa <\/td>\n<\/tr>\n
1700<\/td>\nSECTION AP201 – SELECTION OF PIPE SIZE
SECTION AP201 – SELECTION OF PIPE SIZE <\/td>\n<\/tr>\n
1701<\/td>\nTABLE AP201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
TABLE AP201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) <\/td>\n<\/tr>\n
1702<\/td>\nTABLE AP201.1\u2014continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.
TABLE AP201.1\u2014continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u. <\/td>\n<\/tr>\n
1703<\/td>\nAPPENDIX Q – ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS\/NATIONAL ELECTRICAL CODE CROSS-REFEREN
APPENDIX Q – ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS\/NATIONAL ELECTRICAL CODE CROSS-REFEREN <\/td>\n<\/tr>\n
1717<\/td>\nINDEX
INDEX <\/td>\n<\/tr>\n
1729<\/td>\nMEMBERSHIP BENEFITS
MEMBERSHIP BENEFITS <\/td>\n<\/tr>\n
1730<\/td>\nMUST HAVE TOOLS FOR YOUR IRC\u00ae
MUST HAVE TOOLS FOR YOUR IRC\u00ae <\/td>\n<\/tr>\n
1731<\/td>\nNEW GUIDELINES FOR GOING GREEN
NEW GUIDELINES FOR GOING GREEN <\/td>\n<\/tr>\n
1732<\/td>\nGO-TO RESOURCES FOR YOUR I-CODE
GO-TO RESOURCES FOR YOUR I-CODE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

International Residential Code and Commentary<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2009<\/td>\n1732<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":15987,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-15986","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/15986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/15987"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=15986"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=15986"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=15986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}