{"id":218049,"date":"2024-10-19T14:08:40","date_gmt":"2024-10-19T14:08:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/na-to-bs-en-1995-1-22004\/"},"modified":"2024-10-25T07:20:34","modified_gmt":"2024-10-25T07:20:34","slug":"na-to-bs-en-1995-1-22004","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/na-to-bs-en-1995-1-22004\/","title":{"rendered":"NA to BS EN 1995-1-2:2004"},"content":{"rendered":"
This National Annex gives:<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | Contents Introduction 1 NA.1 Scope 1 NA.2 Nationally Determined Parameters 1 NA.3 Guidance on using informative annexes 2 NA.4 Reference to non-contradictory complementary information 3 Bibliography 4 <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Introduction NA.1 Scope a) the UK decisions for the Nationally Determined Parameters described in the following subclauses of BS EN 1995-1-2:2004: b) the UK decisions on the status of BS EN 1995-1-2:2004 informative annexes; c) reference to non-contradictory complementary information. NA.2 Nationally Determined Parameters NA.2.1 Maximum temperature rise for separating function in parametric fire exposure [BS EN 1995-1-2:2004, 2.1.3(2)] a) average temperature rise (DQ1) of 200 K; b) maximum temperature rise (DQ2) of 240 K. NA.2.2 Partial factor for material properties in fire [BS EN 1995-1-2:2004, 2.3(1)P] <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | NA.2.3 Partial factor for mechanical resistance of connections in a fire situation [BS EN 1995-1-2:2004, 2.3(2)P] NA.2.4 Reduction factor hfi for combinations of actions [BS EN 1995-1-2:2004, 2.4.2(3)] NA.2.5 Procedure for determining cross-sectional properties [BS EN 1995-1-2:2004, 4.2.1(1)] NA.3 Guidance on using informative annexes NA.3.1 Parametric fire exposure [BS EN 1995-1-2:2004, Annex A] NA.3.2 Advanced calculation methods [BS EN 1995-1-2:2004, Annex B] NA.3.3 Load-bearing floor joists and wall studs in assemblies whose cavities are completely filled with insulation [BS EN 1995-1-2:2004, Annex C] NA.3.4 Charring of members in wall and floor assemblies with void cavities [BS EN 1995-1-2:2004, Annex D] <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | NA.3.5 Analysis of the separating function of wall and floor assemblies [BS EN 1995-1-2:2004, Annex E] NA.3.6 Guidance for users of EN 1995-1-2 [BS EN 1995-1-2:2004, Annex F] NA.4 Reference to non-contradictory complementary information <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" UK National Annex to Eurocode 5. Design of timber structures – General – Structural fire design<\/b><\/p>\n |