{"id":227142,"date":"2024-10-19T14:45:54","date_gmt":"2024-10-19T14:45:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-clc-ts-507072020\/"},"modified":"2024-10-25T08:45:25","modified_gmt":"2024-10-25T08:45:25","slug":"bsi-pd-clc-ts-507072020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-clc-ts-507072020\/","title":{"rendered":"BSI PD CLC\/TS 50707:2020"},"content":{"rendered":"
This document provides a measurement and evaluation method for the determination of the representative maximum temperature reached inside the base load during the washing cycle of a washing machine or washer-dryer. The mean maximum temperature within the base load is measured with three temperature sensors, which are attached to towels and\/or pillowcases placed in different, representative locations inside the drum. This document does not provide a method for measuring a temperature for the evaluation of hygiene performance.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative References 3 Terms, definitions and symbols 3.1 Terms and definitions 3.2 Symbols <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4 Test conditions, materials, equipment and instrumentation 5 Preparation for testing 5.1 Preparation of equipment 5.1.1 General 5.1.2 Attaching a data logger to a towel or a pillowcase <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.2 Procedure 5.2.1 Number of data loggers 5.2.2 Placement of data loggers in the base load 5.2.3 Position and orientation of data loggers in full load and quarter load <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5.2.4 Position and orientation of data logger in half load 5.2.5 Schematic representation of data loggers\u2019 position and orientation <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 6 General test requirements 7 Temperature test 7.1 Data acquisition 7.2 Validity of temperature data and test runs <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7.3 Expression of results 8 Assessment of temperature 8.1 Evaluation method to define the maximum temperature reached for 5 minutes inside the base load 8.1.1 General 8.1.2 The maximum temperature for each data logger in each test run \u03d1max,z,i,k shall be expressed in degrees Celsius and calculated as follows: <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 8.1.3 The average maximum temperature for each test run \u03d1max,z,i shall be expressed in degrees Celsius and calculated as follows: 8.1.4 The total average maximum temperature for each treatment (max,z, shall be expressed in degrees Celsius, rounded to one decimal place and calculated as follows: 9 Data to be reported <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Annex A (normative)Test report \u2013 Data to be recorded A.1 General A.2 Data for test washing machine or washer-dryer A.3 Data, parameters and results for the test series <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Clothes washing machines and washer-dryers for household and similar use. Method for the determination of temperature inside the laundry load<\/b><\/p>\n |