{"id":239097,"date":"2024-10-19T15:38:03","date_gmt":"2024-10-19T15:38:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62282-6-3002013\/"},"modified":"2024-10-25T10:19:48","modified_gmt":"2024-10-25T10:19:48","slug":"bs-en-62282-6-3002013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62282-6-3002013\/","title":{"rendered":"BS EN 62282-6-300:2013"},"content":{"rendered":"
IEC 62282-6-300:2012 covers interchangeability of micro fuel cell (MFC) fuel cartridges to provide the cartridge compatibility for a variety of MFC power units while maintaining the safety and performance of MFC power systems. For this purpose, the standard covers fuel cartridges and their connector designs. Fuel type, fuel concentration and fuel quality are also covered. This standard also provides for the means to avoid the miss-connection of an improper fuel cartridge. Test methods for verifying the compliance with the interchangeability requirements for fuel and fuel cartridges are also provided in this standard. The main changes with respect to the previous edition are listed below: – updates to Type A to D interchangeable connectors, addition of Type E; – updates of the procedures, criteria and figures of the type tests for interchangeable connectors to ensure accurate and consistent results.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 2 Normative references 3 Terms and definitions Figures Figure 1 \u2013 MFC power system block diagram <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Figure 2 \u2013 Fuel cartridge types <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4 Fuel connectors 4.1 Basic requirements 4.1.1 Safety <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.1.2 Safety of connectors during connecting, fueling and removing <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.2 Construction and actuation requirements 4.2.1 General 4.2.2 Connector sealing 4.2.3 Connector sequence 4.2.4 Mechanical keys 4.2.5 Material requirement 4.3 Interchangeable fuel connectors 4.3.1 General <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.3.2 Type A Figure 3 \u2013 MFC power unit side connector design(cross-sectional view) Figure 4 \u2013 MFC power unit side connector design (front-elevational view) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 5 \u2013 Seal surface area design for MFC power unit side connector (cross-sectional view) Tables Table 1 \u2013 Dimension and tolerance for MFC power unit side connector <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure 6 \u2013 Cartridge space for satellite cartridge(cross-sectional view) Table 2 \u2013 Dimension of space for satellite cartridgein MFC power unit <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Figure 7 \u2013 Cartridge space for insert cartridge (cross-sectional view) Table 3 \u2013 Dimension for insert cartridge space in MFC power unit <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure 8 \u2013 Mechanical key(wide and 2-key type) Figure 9 \u2013 Mechanical key(narrow and 3-key type) Figure 10 \u2013 Mechanical key variation with key number (front-elevational view) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 4 \u2013 Key location and dimension with tolerance for mechanical key <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 11 \u2013 Connector retainer(unlocked) Figure 12 \u2013 Connector retainer(maximum set-back: locked) Table 5 \u2013 Dimension and tolerance for connector retaineron the MFC power unit side <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4.3.3 Type B <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure 13 \u2013 MFC power unit side connector design (cross-sectional view) Figure 14 \u2013 MFC power unitside connector design (front-elevational view) Table 6 \u2013 Dimension and tolerance for MFC power unit side connector <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Figure 15 \u2013 Cartridge space (cross-sectional view) Table 7 \u2013 Dimension and tolerance <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure 16 \u2013 Mechanical keys Table 8 \u2013 Key location and dimension with tolerance for mechanical key <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Figure 17 \u2013 Connector retainer(cross-sectional view before connection) Figure 18 \u2013 Connector retainer (front-elevational view before connection) Figure 19 \u2013 Connector retainer (cross-sectional view when retained) Figure 20 \u2013 Connector retainer (front-elevational view when retained) <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure 21 \u2013 Connector retainer engaged (cross-sectional view) Table 9 \u2013 Dimension and tolerance for connector retainer on the MFC power unit <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 4.3.4 Type C <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure 22 \u2013 MFC power unit sideconnector design (cross-sectional view) Figure 23 \u2013 MFC power unit sideconnector design (front-elevational view) Table 10 \u2013 Dimension and tolerance for MFC power unit side connector <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure 24 \u2013 Cartridge space (cross-sectional view) Table 11 \u2013 Dimension and tolerance for cartridge space within MFC power unit <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Figure 25 \u2013 Mechanical key (cross-sectional view) Figure 26 \u2013 Mechanical key (front-elevational view) Figure 27 \u2013 Mechanical key variation with key number <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure 28 \u2013 Connector retainer (cross-sectional view) Table 12 \u2013 Key location and dimension with tolerance for mechanical key <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Table 13 \u2013 Dimension and tolerance for the MFC power unit sideconnector retainer <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 4.3.5 Type D Figure 29 \u2013 MFC power unit sideconnector design (cross-sectional view) Figure 30 \u2013 MFC power unit side connector design (front-elevational view) <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Figure 31 \u2013 Cartridge space for insert cartridge (cross-sectional view) Table 14 \u2013 Dimension and tolerance for MFC power unit side connector <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure 32 \u2013 Mechanical key (cross-sectional view) Figure 33 \u2013 Mechanical key (front-elevational view) Table 15 \u2013 Dimension and tolerance for the cartridge space in MFC power unit Table 16 \u2013 Dimension and tolerance for mechanical key <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure 34 \u2013 Mechanical key variation with key number Table 17 \u2013 Key location for mechanical key <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Figure 35 \u2013 Connector retainer (cross-sectional view) Figure 36 \u2013 Connector retainer (front-elevational view) <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Table 18 \u2013 Dimension and tolerance for the MFC power unit side retainer <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 4.3.6 Type E Figure 37 \u2013 MFC power unit side connector design <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure 38 \u2013 Seal surface area design for MFC power unit side connector(cross-sectional view) Table 19 \u2013 Dimension and tolerance for MFC power unit side connector <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure 39 \u2013 Cartridge space for satellite cartridge(cross-sectional view) Table 20 \u2013 Dimension of space for satellite cartridge in MFC power unit <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure 40 \u2013 Cartridge space for insert cartridge (cross-sectional view) Table 21 \u2013 Dimensions for insert cartridge space in MFC power unit <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Figure 41 \u2013 Connector retainer Table 22 \u2013 Dimension and tolerance for connector retaineron the MFC power unit side <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 4.4 Type tests for interchangeable fuel connectors 4.4.1 Test types <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 4.4.2 Mechanical strength requirement for interchangeable fuel connectors 4.4.3 Test parameters <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 4.4.4 Classification of cartridge size and connector strength 4.4.5 Test fixtures Table 23 \u2013 Interchangeable fuel connector type tests Table 24 \u2013 Classification of cartridge size and connector strength <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 4.4.6 Forces expected in normal operation and in foreseeable misuse (f1 and f2) Table 25 \u2013 Device test fixture for cartridge testing Table 26 \u2013 Cartridge test fixture for device testing <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 4.4.7 Number of samples Table 27 \u2013 External forces expected in normal operation and foreseeable misuse <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 4.4.8 Laboratory conditions 4.4.9 Type tests <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Figure 42 \u2013 Flow chart for connector type tests \u2013 Compression test for proper combination and correct orientation in normal operation on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Figure 43 \u2013 Flow chart for connector type tests \u2013 Compression test for proper combination and incorrect orientation in normal operation on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Figure 44 \u2013 Flow chart for connector type tests \u2013 Compression test for proper combination and incorrect orientation in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Figure 45 \u2013 Flow chart for connector type tests \u2013 Compression test for improper mechanical key combination in normal operations on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Figure 46 \u2013 Flow chart for connector type tests \u2013 Compression test for improper mechanical key combination in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Figure 47 \u2013 Flow chart for connector type tests \u2013 Tensile test in normal operations on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Figure 48 \u2013 Flow chart for connector type tests \u2013 Tensile test in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | Figure 49 \u2013 Flow chart for connector type tests \u2013 Torsion test in normal operations on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Figure 50 \u2013 Flow chart for connector type tests \u2013 Torsion test in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Figure 51 \u2013 Flow chart for connector type tests \u2013 Bending test in normal operations on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Figure 52 \u2013 Flow chart for connector type tests \u2013 Bending test in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Figure 53 \u2013 Flow chart for connector type tests \u2013 Drop test in foreseeable misuse on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Figure 54 \u2013 Flow chart for connector type tests \u2013 Vibration test in normal operations on a manufacturer\u2019s cartridge or a manufacturer\u2019s end use MFC device <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 5 Fuel cartridge 5.1 Fuel concentrations 5.2 Cartridge pressure 5.3 Cartridge capacity, size and shape 5.3.1 Cartridge size and shape Figure 55 \u2013 Prismatic cartridge <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Table 28 \u2013 Size and type of prismatic cartridge <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Figure 56 \u2013 Cylindrical cartridge Table 29 \u2013 Size and type of cylindrical cartridge <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 5.3.2 Cartridge capacity and usable fuel determination Table 30 \u2013 Test parameters for usable fuel determination <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Figure 57 \u2013 Test diagram \u2013 Usable fuel measurement for pump-assisted discharging cartridge (option 1) Figure 58 \u2013 Test diagram \u2013 Usable fuel measurement for pump-assisted discharging cartridge (option 2) <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 5.4 Maximum discharge pressure Figure 59 \u2013 Test diagram \u2013 Usable fuel measurement for non-pump assisted discharging cartridge Figure 60 \u2013 Test diagram \u2013 Usable fuel measurement for pressurized cartridge <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Figure 61 \u2013 Flow chart for maximum discharge pressure test <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 5.5 Fuel quality 5.5.1 General requirements 5.5.2 Fuel quality requirements <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 5.5.3 Test sample 5.5.4 Test procedure to measure the residue <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 5.5.5 Impurities test <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 5.5.6 Test set-up for impurities test with fuel cell operation <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | Figure 62 \u2013 Test apparatus Figure 63 \u2013 Test cell construction drawing <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | Figure 64 \u2013 Exploded view of test cell Figure 65 \u2013 Endplate and its flow channel design <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 6 Marking 6.1 Cartridge marking <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | 6.2 MFC power unit or electronic device marking Figure 66 \u2013 Types of fuel cartridges <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 6.3 User information required in the manual or on the packaging <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | Annex A (informative) Calculations of f1, f2, and maximum discharge pressure Table A.1 \u2013 Weight and size of typical cartridge Table A.2 \u2013 Ergonomics data \u2013 Force by human hand or finger <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | Table A.3 \u2013 Forces f1 and f2 for type tests <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | Annex B (informative) Test fixtures Figure B.1 \u2013 Device test fixture for cartridge testing of 4.4.9 <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | Figure B.2 \u2013 Device test fixture for cartridge testing of 5.3.2 and 5.4 <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | Figure B.3 \u2013 Cartridge test fixture for device testing of 4.4.9 <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fuel cell technologies – Micro fuel cell power systems. Fuel cartridge interchangeability<\/b><\/p>\n |