{"id":243988,"date":"2024-10-19T16:01:14","date_gmt":"2024-10-19T16:01:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-clc-tr-61158-12010\/"},"modified":"2024-10-25T10:59:13","modified_gmt":"2024-10-25T10:59:13","slug":"bsi-pd-clc-tr-61158-12010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-clc-tr-61158-12010\/","title":{"rendered":"BSI PD CLC\/TR 61158-1:2010"},"content":{"rendered":"
This technical report presents an overview and guidance for the IEC 61158 series by:<\/p>\n
explaining the structure and content of the IEC 61158 series;<\/p>\n<\/li>\n
relating the structure of the IEC 61158 series to the ISO\/IEC 7498 OSI Basic Reference Model;<\/p>\n<\/li>\n
showing the logical structure of the IEC 61784 series;<\/p>\n<\/li>\n
showing how to use parts of the IEC 61158 series in combination with the IEC 61784 series;<\/p>\n<\/li>\n
providing explanations of some aspects of the IEC 61158 series that are common to the parts of the IEC 61158-5 series.<\/p>\n<\/li>\n<\/ul>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references 3 Abbreviations 4 Guidelines for implementers and users 4.1 Background and purpose <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.2 Supported options 4.3 Benefits from using a common and formal style <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5 Concept of the IEC\u00a061158 series Figures Figure 1 \u2013 Generic fieldbus network <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6 Mapping onto the OSI Basic Reference Model 6.1 Overview Figure 2 \u2013 Concept of DL\/AL to separate service and protocol parts <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.2 Physical layer service and protocol Figure 3 \u2013 Basic fieldbus reference model Tables Table 1 \u2013 OSI and IEC\u00a061158 layers <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.3 Data-link layer service Figure 4 \u2013 General model of physical layer <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.4 Data-link layer protocol 6.5 Application layer service Figure 5 \u2013 Relationship of the IEC\u00a061158 3 and IEC\u00a061158 4 series to other fieldbus layers and to users of the fieldbus data-link service <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.6 Application layer protocol Figure 6 \u2013 Relationship of the IEC\u00a061158 5 and IEC\u00a061158 6 series to other fieldbus layers and to users of the fieldbus application service <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7 Structure of IEC\u00a061158 and IEC\u00a061784 series 7.1 The IEC\u00a061158 physical layer 7.2 The IEC\u00a061158 data-link layer <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.3 The IEC\u00a061158 application layer 7.4 IEC\u00a061784 1 and IEC\u00a061784 2 fieldbus profiles <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure 7 \u2013 Structure of communication profile families <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Figure 8 \u2013 Example of a CPF structure <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 2 \u2013 CPF, CP, and type relations <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.5 IEC\u00a061784 3 functional safety communication profiles <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 7.6 IEC\u00a061784 5 installation profiles <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 9 \u2013 Document structure of IEC\u00a061918 and the IEC\u00a061784 5 series <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8 Brief summary of the characteristics of each service and protocol for each type of fieldbus 8.1 Summary of the physical layer service and protocol characteristics <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 8.2 Summary of data-link layer service characteristics <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.3 Summary of data-link layer protocol characteristics <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.4 Summary of application layer service characteristics <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8.5 Summary of application layer protocol characteristics <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9 Application layer service description concepts 9.1 Overview <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 9.2 Architectural relationships Figure 10 \u2013 Relationship to the OSI Basic Reference Model <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure 11 \u2013 Architectural positioning of the fieldbus application layer <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 9.3 Fieldbus application layer structure <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Figure 12 \u2013 Client\/server interactions <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Figure 13 \u2013 Pull model interactions <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure 14 \u2013 Push model interactions Table 3 \u2013 Types of timeliness defined for publisher\/subscriber interactions <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure 15 \u2013 APOs services conveyed by the FAL <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figure 16 \u2013 Application entity structure <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure 17 \u2013 Example FAL ASEs Figure 18 \u2013 FAL management of objects <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure 19 \u2013 ASE service conveyance <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 9.4 Fieldbus application layer naming and addressing Figure 20 \u2013 Defined and established AREPs <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 9.5 Architecture summary 9.6 Notional FAL service procedures Figure 21 \u2013 FAL architectural components <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 9.7 Common FAL attributes <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 9.8 Common FAL service parameters <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 9.9 APDU size 10 Data type ASE 10.1 Overview <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Figure 22 \u2013 Data-type class hierarchy example <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 10.2 Formal definition of data type objects <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Annex A (informative) Trade name declarations Table A.1 \u2013 Trade names of CPFs and CPs <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Industrial communication networks. Fieldbus specifications – Overview and guidance for the IEC 61158 and IEC 61784 series<\/b><\/p>\n |