{"id":245413,"date":"2024-10-19T16:08:26","date_gmt":"2024-10-19T16:08:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61158-5-232019\/"},"modified":"2024-10-25T11:08:34","modified_gmt":"2024-10-25T11:08:34","slug":"bs-en-iec-61158-5-232019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61158-5-232019\/","title":{"rendered":"BS EN IEC 61158-5-23:2019"},"content":{"rendered":"
IEC 61158-5-23:2019 defines the services provided to the FAL user at the boundary between the user and the application layer of the fieldbus reference model, and Systems Management at the boundary between the application layer and Systems Management of the fieldbus reference model. This standard specifies the structure and services of the IEC fieldbus application layer, in conformance with the OSI Basic Reference Model (ISO\/IEC 7498-1) and the OSI application layer structure (ISO\/IEC 9545). lt;br \/gt;This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. lt;br \/gt;This edition includes the following significant technical changes with respect to the previous edition:\u2022addition of an attribute for Master ID (see 3.2.10, 6.4.3, 6.4.4 and 6.4.5)<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1 Scope 1.1 General <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 1.2 Specifications 1.3 Conformance 2 Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Referenced terms and definitions 3.1.1 ISO\/IEC\u00a074981 terms 3.1.2 ISO\/IEC\u00a08822 terms 3.1.3 ISO\/IEC\u00a09545 terms <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 3.1.4 ISO\/IEC\u00a088241 terms 3.1.5 IEC\u00a0611581 terms 3.2 Additional Type 23 terms and definitions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 3.3 Symbols and abbreviated terms <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 3.4 Conventions 3.4.1 General conventions <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 3.4.2 Conventions for class definitions <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 3.4.3 Conventions for service definitions <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4 Concept 5 Data type ASE 5.1 Overview <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.2 Fixed length types 5.2.1 Bitstring types <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.2.2 Numeric types <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6 Communication model specification 6.1 Communication model 6.1.1 General 6.1.2 Cyclic model n:n <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.1.3 Cyclic model 1:n 6.1.4 Transient model Figures Figure 1\u00a0\u2013\u00a0Cyclic model (n:n type distributed shared memory, unconfirmed push model) Figure 2\u00a0\u2013\u00a0Cyclic model (1:n type distributed shared memory, unconfirmed push model) Figure 3\u00a0\u2013\u00a0Transient model (Client server model) <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.2 ASE 6.2.1 Overview type C 6.2.2 Overview type F 6.2.3 Cyclic data ASE type C Figure 4\u00a0\u2013\u00a0Transient model (Push model) Figure 5\u00a0\u2013\u00a0Structure of ASE type C of FAL type 23 Figure 6\u00a0\u2013\u00a0Structure of ASE type F of FAL Type 23 <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Tables Table 1\u00a0\u2013\u00a0Ld service parameters Table 2\u00a0\u2013\u00a0Set service parameters Table 3\u00a0\u2013\u00a0Reset service parameters <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table 4\u00a0\u2013\u00a0Read service parameters Table 5\u00a0\u2013\u00a0Write service parameters <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Table 6\u00a0\u2013\u00a0Ld service parameters <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Table 7\u00a0\u2013\u00a0Set service parameters Table 8\u00a0\u2013\u00a0Reset service parameters <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Table 9\u00a0\u2013\u00a0Read service parameters Table 10\u00a0\u2013\u00a0Write service parameters <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 6.2.4 Cyclic data ASE type F <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Table 11\u00a0\u2013\u00a0Ld service parameters <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Table 12\u00a0\u2013\u00a0Set service parameters Table 13\u00a0\u2013\u00a0Reset service parameters <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Table 14\u00a0\u2013\u00a0Read service parameters Table 15\u00a0\u2013\u00a0Write service parameters <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 6.2.5 Acyclic data ASE type C <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Table 16\u00a0\u2013\u00a0Get memory access info service parameters <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Table 17\u00a0\u2013\u00a0Run service parameters <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Table 18\u00a0\u2013\u00a0Stop service parameters <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Table 19\u00a0\u2013\u00a0Read memory service parameters <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Table 20\u00a0\u2013\u00a0Write memory service parameters <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 6.2.6 Acyclic data ASE type F <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Table 21\u00a0\u2013\u00a0Get memory access info service parameters <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Table 22\u00a0\u2013\u00a0Run service parameters <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Table 23\u00a0\u2013\u00a0Stop service parameters <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Table 24\u00a0\u2013\u00a0Read memory service parameters <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Table 25\u00a0\u2013\u00a0Write memory service parameters <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Table 26\u00a0\u2013\u00a0Vendor command service parameters <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Table 27\u00a0\u2013\u00a0Distribute node info service parameters <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Table 28\u00a0\u2013\u00a0Get statistics service parameters <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Table 29\u00a0\u2013\u00a0Get node info detail service parameters <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Table 30\u00a0\u2013\u00a0AC data service parameters <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 6.2.7 Management ASE Table 31\u00a0\u2013\u00a0AC data ND service parameters <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | Table 32\u00a0\u2013\u00a0Get attribute service parameters <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Table 33\u00a0\u2013\u00a0Set attribute service parameters <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 6.2.8 Synchronization ASE Table 34\u00a0\u2013\u00a0Synchronization trigger service parameters <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 6.2.9 Measurement ASE Table 35\u00a0\u2013\u00a0Start measurement service parameters <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 6.3 AR type C 6.3.1 Overview Table 36\u00a0\u2013\u00a0Get offset service parameters <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 6.3.2 Connection Control Figure 7\u00a0\u2013\u00a0Structure of AR type C <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 6.3.3 Cyclic transmission type C Table 37\u00a0\u2013\u00a0Control cyclic service parameters <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Table 38\u00a0\u2013\u00a0CT Update service parameters <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 6.3.4 Acyclic transmission type C Table 39\u00a0\u2013\u00a0AC Send service parameters <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | 6.3.5 Common parameter dist Table 40\u00a0\u2013\u00a0AC Param send service parameters <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Table 41\u00a0\u2013\u00a0CPD Set service parameters <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 6.4 AR type F 6.4.1 Overview 6.4.2 Channel control Figure 8\u00a0\u2013\u00a0Structure of AR type F <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 6.4.3 Cyclic transmission type F Table 42\u00a0\u2013\u00a0Control cyclic service parameters <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Table 43\u00a0\u2013\u00a0CT Update service parameters <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 6.4.4 Acyclic transmission type F Table 44\u00a0\u2013\u00a0AC Send service parameters <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | Table 45\u00a0\u2013\u00a0AC Send ND service parameters <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 6.4.5 Parameter dist <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 6.4.6 Synchronous trigger Table 46\u00a0\u2013\u00a0Synchronous trigger internal service parameters <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 6.4.7 Measurement transmission Table 47\u00a0\u2013\u00a0Measure send service parameters <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Table 48\u00a0\u2013\u00a0MeasureAck send service parameters Table 49\u00a0\u2013\u00a0Offset send service parameters <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | Table 50\u00a0\u2013\u00a0Update send service parameters <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Industrial communication networks. Fieldbus specifications – Application layer service definition. Type 23 elements<\/b><\/p>\n |