{"id":275275,"date":"2024-10-19T18:30:44","date_gmt":"2024-10-19T18:30:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-16392-22014\/"},"modified":"2024-10-25T14:55:25","modified_gmt":"2024-10-25T14:55:25","slug":"bs-en-16392-22014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-16392-22014\/","title":{"rendered":"BS EN 16392-2:2014"},"content":{"rendered":"

This European Standard covers linear phased array probes used for ultrasonic non-destructive testing in contact technique (with or without a wedge) or in immersion technique, with centre frequencies in the range 0,5 MHz \u2013 10 MHz.<\/p>\n

This European Standard specifies the characterisation tests that have to be done at the end of the fabrication of a phased array probe. It defines both methodology and acceptance criteria.<\/p>\n

This document does not describe methods and acceptance criteria to characterise the performance of an ultrasonic phased array instrument or the performance of a combined system. These are described in prEN ISO 18563-1 and in prEN ISO 18563-3.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nContents Page <\/td>\n<\/tr>\n
5<\/td>\nForeword <\/td>\n<\/tr>\n
6<\/td>\n1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for compliance <\/td>\n<\/tr>\n
7<\/td>\n5 Technical specification for phased array probes <\/td>\n<\/tr>\n
8<\/td>\nTable 1 \u2013 Technical information to be given in the probe data sheet
Table 2 \u2013 Optional technical information to be shown in the probe data sheet <\/td>\n<\/tr>\n
9<\/td>\n6 Test equipment
6.1 Electronic equipment
6.2 Tests block and other equipment
7 Performance tests for phased array probes
7.1 General <\/td>\n<\/tr>\n
10<\/td>\n7.2 Physical aspects
7.2.1 Method
7.2.2 Acceptance criterion
7.3 Frequency, bandwidth and pulse duration
7.3.1 General
7.3.2 Method
7.3.3 Acceptance criteria <\/td>\n<\/tr>\n
11<\/td>\n7.4 Relative pulse-echo sensitivity variation
7.4.1 General
7.4.2 Method
7.4.3 Acceptance criterion
7.5 Probe sensitivity
7.5.1 General
7.5.2 Method
7.5.3 Acceptance criterion <\/td>\n<\/tr>\n
12<\/td>\n7.6 Inter-element cross-talk
7.6.1 General
7.6.2 Method
7.6.3 Acceptance criterion <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Non-destructive testing. Characterisation and verification of ultrasonic phased array equipment – Probes<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2014<\/td>\n14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":275278,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-275275","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/275275","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/275278"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=275275"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=275275"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=275275"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}