{"id":363377,"date":"2024-10-20T01:45:18","date_gmt":"2024-10-20T01:45:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-vi-2007\/"},"modified":"2024-10-26T02:45:02","modified_gmt":"2024-10-26T02:45:02","slug":"asme-bpvc-vi-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-vi-2007\/","title":{"rendered":"ASME BPVC VI 2007"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | LIST OF BPVC SECTIONS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | CONTENTS 2. FIGURES <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 3. FIGURES 3. TABLES <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 5. FIGURES <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | STATEMENTS OF POLICY <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | PERSONNEL <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | SUMMARY OF CHANGES <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 1. GENERAL 1.01 SCOPE 1.02 USE OF ILLUSTRATIONS 1.03 MANUFACTURER’S INFORMATION 1.04 REFERENCE TO SECTION IV 1.05 GLOSSARY OF TERMS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 2. TYPES OF BOILERS 2.01 CLASSIFICATION 2.02 STEEL BOILERS 2.03 CAST IRON BOILERS 2.04 MODULAR BOILERS 2.05 VACUUM BOILERS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 2.02A-1 HORIZONTAL RETURN TUBE, BRICK-SET 2.02A-2 GAS FLOW PATTERNS OF SCOTCH-TYPE BOILERS <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 2.02A-3 TYPE C FIREBOX BOILER 2.02A-4 THREE-PASS FIREBOX BOILER <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 2.02A-5 LOCOMOTIVE FIREBOX BOILER 2.02A-6 VERTICAL FIRETUBE BOILER <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 2.03A HORIZONTAL SECTIONAL CAST IRON BOILER 2.03B VERTICAL SECTIONAL CAST IRON BOILER 2.04A MODULES CONNECTED WITH PARALLEL PIPING 2.04B MODULES CONNECTED WITH PRIMARY-SECONDARY PIPING <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 3. ACCESSORIES AND INSTALLATION 3.01 SAFETY AND SAFETY RELIEF VALVES 3.02 LOW- WATER FUEL CUTOFFS AND WATER FEEDERS 3.03 TRAPS 3.04 AIR ELIMINATORS 3.01 OFFICIAL SYMBOL <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 3.05 CONDENSATE RETURN PUMPS AND RETURN LOOP 3.06 VACUUM RETURN PUMP 3.07 CIRCULATORS (CIRCULATING PUMPS) 3.08 EXPANSION TANK 3.01A SAFETY VALVE <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 3.01B SAFETY RELIEF VALVE 3.02A FLOAT TYPE LOW-WATER CUTOFF <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 3.02B ELECTRIC PROBE TYPE LOW-WATER CONTROL <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 3.09 OIL PREHEATERS 3.10 FUEL OIL STORAGE AND SUPPLY SYSTEMS 3.11 PRESSURE GAGE 3.03-1 THERMOSTATIC TRAP 3.03-2 FLOAT TRAP 3.03-3 FLOAT AND THERMOSTATIC TRAP 3.03-4 BUCKET TRAP WITH TRAP CLOSED <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 3.20 PRESSURE RELIEVING VALVE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 3.05 TYPICAL RETURN LOOP <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 3.11 PRESSURE GAGES <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 3.20 MINIMUM POUNDS OF STEAM PER HOUR PER SQUARE FOOT OF HEATING SURFACE (kg\/h\/m2) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 3.20H SAFETY RELIEF VALVE DISCHARGE PIPE <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 3.21 STEAM GAGES 3.22 WATER GAGE GLASSES 3.23 WATER COLUMN AND WATER LEVEL CONTROL PIPES <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 3.24 PRESSURE CONTROL 3.25 PRESSURE OR ALTITUDE GAGES 3.26 THERMOMETERS 3.27 TEMPERATURE CONTROL 3.28 AUTOMATIC LOW- WATER FUEL CUTOFF AND\/ OR WATER FEEDING DEVICE (STEAM) <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 3.29 LOW- WATER FUEL CUTOFF (HOT WATER) 3.30 PIPING <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 3.31 PROVISIONS FOR THERMAL EXPANSION IN HOT WATER SYSTEMS 3.32 STOP VALVES <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 3.30-1 SINGLE HOT WATER HEATING BOILER \u2014 ACCEPTABLE PIPING INSTALLATION <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 3.30-2 HOT WATER HEATING BOILERS IN BATTERY \u2014 ACCEPTABLE PIPING INSTALLATION <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 3.30-3 SINGLE STEAM BOILERS — ACCEPTABLE PIPING INSTALLATION <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | 3.30-4A STEAM BOILERS IN BATTERY — PUMPED RETURN — ACCEPTABLE PIPING INSTALLATION <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 3.30-4B STEAM BOILERS IN BATTERY — GRAVITY RETURN — ACCEPTABLE PIPING INSTALLATION <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | 3.33 BOTTOM BLOWOFF AND DRAIN VALVES 3.34 OIL HEATERS 3.35 SHUTDOWN SWITCHES AND CIRCUIT BREAKERS 3.31C-1 EXPANSION TANK CAPACITIES FOR GRAVITY HOT WATER SYSTEMS 3.31C-2 EXPANSION TANK CAPACITIES FOR FORCED HOT WATER SYSTEMS 3.33 SIZE OF BOTTOM BLOWOFF PIPING, VALVES, AND COCKS <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 3.36 MODULAR BOILERS 3.37 VACUUM BOILERS 3.38 STORAGE TANKS FOR HOT WATER SUPPLY SYSTEMS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 4. FUELS 4.01 GAS \u2014 NATURAL, MANUFACTURED, MIXED 4.02 LIQUEFIED PETROLEUM GAS (LPG) 4.03 FUEL OILS <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | 4.04 COAL 4.05 ELECTRICITY <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | 5. FUEL BURNING EQUIPMENT AND FUEL BURNING CONTROLS 5.01 GAS BURNING EQUIPMENT 5.02 OIL BURNING EQUIPMENT 5.01A ATMOSPHERIC GAS BURNER <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | 5.01C COMBINATION FUEL BURNERS 5.02A HIGH-PRESSURE ATOMIZING BURNER <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | 5.03 COAL BURNING EQUIPMENT 5.04 CONTROLS 5.02D HORIZONTAL ROTARY CUP FUEL OIL BURNER <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 5.03-1 UNDERFEED SINGLE-RETORT STOKER 5.03-2 OVERTHROW RECIPROCATING PLATE-FEED TYPE SPREADER STOKER <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | 5.03-3 CHAIN GRATE STOKER WITH SECTION SHOWING LINKS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | 6. BOILER ROOM FACILITIES 6.01 GENERAL 6.02 SAFETY 6.03 LIGHTING 6.04 VENTILATION 6.05 WATER AND DRAIN CONNECTIONS 6.06 FIRE PROTECTION 6.07 HOUSEKEEPING <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | 6.08 POSTING OF CERTIFICATES AND\/ OR LICENSES 6.09 RECORDKEEPING, LOGS, ETC. <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 7. OPERATION, MAINTENANCE, AND REPAIR \u2014 STEAM BOILERS 7.01 STARTING A NEW BOILER AND HEATING SYSTEM <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 7.02 STARTING A BOILER AFTER LAYUP (SINGLE BOILER INSTALLATION) 7.03 CONDENSATION 7.04 CUTTING IN AN ADDITIONAL BOILER 7.05 OPERATION <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 7.06 REMOVAL OF BOILER FROM SERVICE 7.07 MAINTENANCE <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 7.08 BOILER REPAIRS 7.09 TESTS AND INSPECTIONS OF STEAM HEATING BOILERS <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 8. OPERATION, MAINTENANCE, AND REPAIR \u2014 HOT WATER BOILERS AND HOT WATER HEATING BOILERS 8.01 STARTING A NEW BOILER AND HEATING SYSTEM 8.02 STARTING A BOILER AFTER LAYUP (SINGLE BOILER INSTALLATION) <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 8.03 CONDENSATION 8.04 CUTTING IN AN ADDITIONAL BOILER 8.05 OPERATION <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | 8.06 REMOVAL OF BOILER FROM SERVICE 8.07 MAINTENANCE <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 8.08 BOILER REPAIRS <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 8.09 TESTS AND INSPECTIONS OF HOT WATER HEATING AND SUPPLY BOILERS <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 9. WATER TREATMENT 9.01 SCOPE 9.02 CONSIDERATIONS 9.03 SERVICES OF WATER TREATMENT SPECIALISTS 9.04 CONFORMITY WITH LOCAL ORDINANCES 9.05 BOILER WATER TROUBLES 9.06 CHEMICALS USED <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 9.07 FUNCTIONS OF CHEMICALS 9.08 TREATMENT ALTERNATIVES 9.09 BLOWDOWN <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 9.10 FEEDERS 9.11 PROCEDURES 9.12 GLOSSARY OF WATER TREATMENT TERMS <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | MANDATORY APPENDICES I EXHIBITS <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | EXHIBIT A MAINTENANCE, TESTING, AND INSPECTION LOG – STEAM HEATING BOILERS <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | EXHIBIT B MAINTENANCE, TESTING, AND INSPECTION LOG – HOT WATER HEATING BOILERS <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | EXHIBIT C TESTS I. FLAME SAFEGUARD DEVICE A. Gas \u2014 Thermal Type B. Oil \u2014 Thermal Type, Stack Switch C. Gas \u2014 Electronic Flame Rod Type With Stand-ing Pilot D. Gas \u2014 Electronic Flame Rod With Interrupted Ignition E. Gas \u2014 Electronic Flame Scanner Type. F. Oil \u2014 Electronic Flame Scanner Type G. Oil or Gas \u2014 Electric Type With Proven Pilot Flame Detection H. Pilot Turndown Test <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | I. Reference to ASME CSD- 1. II. COMBUSTION EFFICIENCY TESTS A. Oil Burners B. Gas Burners <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | C. Draft Measurements at the Boiler Breeching. III. LIMIT CONTROL TESTS A. High- Limit Steam Pressure Control. B. Draft- Limit Control. C. Boiler Room Temperature- Limit Control. D. Electrical Limit Controls. E. Low Gas Pressure Control. F. High Gas Pressure Control. G. Oil Pressure Supervisory Switch. <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | H. Air Pressure Supervisory Switch. I. Emergency Disconnect Switch. IV. SAFETY VALVE TESTS (STEAM BOILERS) A. Try Lever Test. B. Pop Test. <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | C. Capacity Test V. SAFETY RELIEF VALVE TEST (WATER BOILERS) A. Try Lever Test B. Safety Relief Valve Test <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | II SUBMITTAL OF TECHNICAL INQUIRIES TO THE BOILER AND PRESSURE VESSEL COMMITTEE II- 100 INTRODUCTION II- 200 INQUIRY FORMAT II- 300 CODE REVISIONS OR ADDITIONS <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | II- 400 CODE CASES II- 500 CODE INTERPRETATIONS II- 600 SUBMITTALS <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | III STANDARD UNITS FOR USE IN EQUATIONS <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | NONMANDATORY APPENDIX A GUIDANCE FOR THE USE OF U. S. CUSTOMARY AND SI UNITS IN THE ASME BOILER AND PRESSURE VESSEL CODE A-1 USE OF UNITS IN EQUATIONS A-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | A-3 SOFT CONVERSION FACTORS <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – VI -2007 BPVC Section VI, Recommended Rules for the Care and Operation of Heating Boilers<\/b><\/p>\n |