{"id":389542,"date":"2024-10-20T03:50:30","date_gmt":"2024-10-20T03:50:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-6344-32021\/"},"modified":"2024-10-26T07:03:26","modified_gmt":"2024-10-26T07:03:26","slug":"bs-iso-6344-32021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-6344-32021\/","title":{"rendered":"BS ISO 6344-3:2021"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 Grain size distribution of microgrit sizes P240 to P1200 <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5 Test method of microgrit sizes P240 to P1200 5.1 Materials 5.1.1 Sedimentation medium 5.1.2 Dispersing agent <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5.1.3 Checking minerals <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.2 Apparatus <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.3 Preparation 5.3.1 Preparation of the apparatus <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.3.2 Preparation of the test portion 5.4 Procedure 5.4.1 Filling of sedimentation tube 5.4.2 Dispersion of the test portion <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.4.3 Transfer to sedimentation tube 5.4.4 Start of measurement 5.4.5 Determination of the maximum grain size 5.4.6 Recording measurement values 5.5 Evaluation 5.5.1 General <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.5.2 Determination of the grain diameter, d <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.5.3 Determination of the volume fraction <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.5.4 Representation of the grain size distribution curve <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.5.5 Evaluation of the grain size distribution 5.5.6 Example of measuring a test portion of fused aluminium oxide 5.5.7 Permissible deviations <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6 Grain size distribution of microgrit sizes P1500 to P5000 7 Test method of microgrit sizes P1500 to P5000 7.1 Materials 7.1.1 Micro-P-Mastergrits <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.1.2 Dispersing medium 7.2 Apparatus 7.3 Preparation 7.3.1 Preparation of the test portion <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 7.3.2 Calibration of the Apparatus 7.4 Procedure for the determination of the grain size distribution 7.5 Evaluation 7.5.1 Evaluation of the grain size distribution 7.5.2 Permissible deviations <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8 Test report 9 Designation 10 Marking <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Annex A (informative) Theoretical equivalent grain diameters, d, for grits of fused aluminium oxide and for grits of silicon carbide <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex B (informative) Template for recording results of a sedimentation analysis of microgrit P sizes using the US sedimentometer <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex C (informative) Example of recording results of a sedimentation analysis of microgrit P sizes using the US sedimentometer <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Coated abrasives. Determination and designation of grain size distribution – Microgrit sizes P240 to P5000<\/b><\/p>\n |