{"id":419651,"date":"2024-10-20T06:26:56","date_gmt":"2024-10-20T06:26:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-625232010\/"},"modified":"2024-10-26T12:02:50","modified_gmt":"2024-10-26T12:02:50","slug":"bs-iec-625232010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-625232010\/","title":{"rendered":"BS IEC 62523:2010"},"content":{"rendered":"
This International Standard applies to radiographic inspection systems with photon radiation energy of at least 500 keV for inspection of cargo, vehicles and cargo containers.<\/p>\n
Such inspection systems generally consist of radiation source(s), detectors, control system, image processing system, radiation safety system and other auxiliary devices\/facilities.<\/p>\n
The object of this standard is to define the tests and the relevant testing methods for determining the performance characteristics of the radiographic inspection systems.<\/p>\n
This standard is not applicable to those cargo\/vehicle inspection systems using neutron source radiography, computed tomography or backscatter technology.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope and object 2 Normative references <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 General characteristics of cargo\/vehicle radiographic inspection system 4.1 General 4.2 Emergency stop devices 4.3 Software 4.4 Markings 4.5 Ambient dose equivalent rate isodose contour <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.6 Radioactive sources 4.7 Safety interlocks 4.8 Status indicators 4.9 Monitoring system 5 Inspection system classification 6 General test procedures 6.1 Nature of tests 6.2 Reference conditions and standard test conditions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6.3 Other conditions of the test 7 Imaging performance tests 7.1 Steel penetration Tables Table 1 \u2013 Reference conditions and standard test conditions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 7.2 Wire detection Figures Figure 1 \u2013 Steel penetration testing apparatus <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 7.3 Contrast sensitivity Figure 2 \u2013 Wire detection testing apparatus <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7.4 Spatial resolution Figure 3 \u2013 Contrast indicator test apparatus <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.5 Material discrimination capability Figure 4 \u2013 Spatial resolution test apparatus Table 2 \u2013 Thicknesses for each material <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 8 Radiological safety tests 8.1 General 8.2 Ambient dose equivalent rate isodose contour Figure 5 \u2013 A test sample for material discrimination capability test <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8.3 Ambient dose equivalent rate on the system boundary Figure 6 \u2013 Layout of an example ambient dose equivalent rate isodose contour <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.4 Ambient dose equivalent rate at the operating positions 8.5 Ambient dose equivalent to the driver <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 8.6 Ambient dose equivalent to the object being inspected 9 Electrical safety tests 9.1 Equipment ground protection 9.2 Insulation resistance 9.3 Voltage test <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.4 Electric shock protection 10 Electromagnetic compatibility 10.1 Requirements 10.2 Test method Table 3 \u2013 Test voltage <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 11 Environmental requirements 11.1 Requirements 11.2 Test method 12 Documentation <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Radiation protection instrumentation. Cargo\/vehicle radiographic inspection system<\/b><\/p>\n |