{"id":425463,"date":"2024-10-20T06:56:59","date_gmt":"2024-10-20T06:56:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61300-2-12023\/"},"modified":"2024-10-26T13:06:18","modified_gmt":"2024-10-26T13:06:18","slug":"bs-en-iec-61300-2-12023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61300-2-12023\/","title":{"rendered":"BS EN IEC 61300-2-1:2023"},"content":{"rendered":"
This part of IEC 61300 evaluates the effects of vibration on fibre optic devices at the predominant frequency ranges and magnitudes that are encountered during field service on attenuation. NOTE Most vibrations encountered in service are not of a simple harmonic nature. However, it has been shown that tests based on vibrations of this type are satisfactory to simulating actual service.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 General description <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5 Apparatus 5.1 General 5.2 Vibration generator 5.3 Mounting fixture 5.4 Acceleration monitoring device 5.5 Measuring equipment 6 Procedure 6.1 Preparation of DUT 6.2 Preconditioning 6.3 Initial examination and measurement <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 6.4 Mounting and test procedure 6.5 Monitoring 6.6 Recovery 6.7 Final examination and measurement Figure 1 \u2013 Example of vibration apparatus <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7 Severity Table 1 \u2013 Recommended values of the test parameters for connectors and passive components Table 2 \u2013 Recommended values of the test parameters for fibre management systems Table 3 \u2013 Recommended values of the test parameters for mechanical splices and field mountable connectors <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Table 4 \u2013 Recommended values of the test parameters for wall outlets and optical distribution frame modules Table 5 \u2013 Recommended values of the test parameters for hardened optical connectors Table 6 \u2013 Recommended values of the test parameters for boxes and closures Table 7 \u2013 Recommended values of the test parameters for street cabinets <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 8 Details to be specified and reported <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Tests. Vibration (sinusoidal)<\/b><\/p>\n |