{"id":51799,"date":"2024-10-17T08:53:01","date_gmt":"2024-10-17T08:53:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d2196-2\/"},"modified":"2024-10-24T16:42:08","modified_gmt":"2024-10-24T16:42:08","slug":"astm-d2196-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d2196-2\/","title":{"rendered":"ASTM-D2196"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 These test methods cover the determination of the apparent viscosity and the shear thinning and thixotropic properties of non-Newtonian materials in the shear rate range from 0.1 to 50 s1<\/sup>.<\/p>\n 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.<\/p>\n 1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/p>\n Keywords<\/strong><\/p>\n Brookfield viscometer; non-Newtonian; rheological properties; rheology; rotational; shear thinning; thixotropic; thixotropy; viscometer; viscosity<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 17.060 (Measurement of volume, mass, density, viscosity)<\/p>\n DOI:<\/strong> 10.1520\/D2196-05<\/p>\n<\/div>\n Significance and Use D2196-05 Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield type) Viscometer<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents <\/p>\n
Apparatus
Materials
Calibration of Apparatus <\/td>\n<\/tr>\n\n 2<\/td>\n Preparation of Specimen
Procedure
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n\n 3<\/td>\n Calculation (Dial Reading Viscometer)
Report
Precision and Bias
Procedure
Calculations and Interpretation of Results
Report <\/td>\n<\/tr>\n\n 4<\/td>\n Precision and Bias
Apparatus
Preparation of Specimen
Procedure
Calculations and Interpretation of Results
Report
Precision and Bias
Summary of Precision <\/td>\n<\/tr>\n\n 5<\/td>\n Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2005<\/td>\n 5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":51800,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-51799","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/51799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/51800"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=51799"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=51799"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=51799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}