{"id":72554,"date":"2024-10-17T16:20:17","date_gmt":"2024-10-17T16:20:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d4637-2012-2\/"},"modified":"2024-10-24T19:07:02","modified_gmt":"2024-10-24T19:07:02","slug":"astm-d4637-2012-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d4637-2012-2\/","title":{"rendered":"ASTM-D4637 2012"},"content":{"rendered":"<\/p>\n

1.1 This specification covers flexible sheet made from ethylene-propylene-diene terpolymer (EPDM) intended for use in single-ply roofing membranes exposed to the weather. The tests and property limits used to characterize the sheet are values to ensure minimum quality for the intended use. The sheet may be non-reinforced, fabric- or scrim-reinforced, or fabric-backed vulcanized rubber sheet.<\/p>\n

1.2 In-place roof system design criteria, such as fire resistance, field seaming strength, material compatibility, and uplift resistance, among others, are factors that must be considered but are beyond the scope of this specification.<\/p>\n

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.<\/p>\n

1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Classification
Materials and Manufacture <\/td>\n<\/tr>\n
2<\/td>\nPhysical Properties and Tolerances
Dimensions
Workmanship, Finish, and Appearance
Test Methods
TABLE 1 <\/td>\n<\/tr>\n
3<\/td>\nInspection and Special Testing
Rejection and Resubmittal
Product Marking
Packaging and Package Marking <\/td>\n<\/tr>\n
4<\/td>\nKeywords
A1. PROCEDURE TO MEASURE THE GLASS TRANSITION TEMPERATURE (Tg) BY DYNAMIC MECHANICAL ANALYSIS
A1.1
A1.2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D4637\/D4637M-12 Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2012<\/td>\n4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":72555,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1260,2637],"product_tag":[],"class_list":{"0":"post-72554","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-50","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/72554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/72555"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=72554"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=72554"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=72554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}