Shopping Cart

No products in the cart.

ASME PTC 30.1 07:2007 Edition

$98.04

ASME PTC 30.1 Air-Cooled Steam Condensers

Published By Publication Date Number of Pages
ASME 2007 86
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
FIGURES
TABLES
6 NOTICE
7 FOREWORD
8 COMMITTEE ROSTER
9 CORRESPONDENCE WITH THE PTC 30.1 COMMITTEE
10 Section 1 Object and Scope
1-1 OBJECT
1-2 SCOPE
1-3 UNCERTAINTY
12 Section 2 Definitions and Descriptions of Terms
2-1 SYMBOLS
2-2 DEFINITIONS
13 2-1 Symbols
17 Section 3 Guiding Principles
3-1 INTRODUCTION
3-2 AGREEMENT AMONG PARTIES TO THE TEST
3-2.1 Contractual Agreements
18 3-2.2 Pretest Agreements
3-3 UNCERTAINTY ANALYSIS
3-2.2 Noncondensible Gas Load Limits
19 3-3.1 Pretest Uncertainty Analysis
3-3.2 Post-Test Uncertainty Analysis
3-4 TEST PREPARATIONS
3-4.1 Equipment Inspection
3-4.2 Instrument Calibrations
3-5 ARRANGEMENT OF TEST APPARATUS
3-5.1 Required Measurements
20 3-5 Arrangement of Test Apparatus
21 3-6 TEST PERSONNEL
3-7 METHOD OF OPERATION DURING THE TEST
3-8 CONDUCT OF TEST
3-8.1 Test Modes
3-8.2 Starting and Stopping Tests and Test Runs
3-8.2.1 Starting Criteria.
3-8.2.2 Stopping Criteria.
22 3-8.3 Testing Conditions
3-8.3.1 Test Stabilization.
3-8.3.2 Operating Conditions.
3-8.3.3 ACC Operation.
3-8.4 Adjustments Prior to and During Tests
3-8.4.1 Permissible Adjustments During Stabilization Periods or Between Test Runs.
3-8.4.2 Permissible Adjustments During Test Runs.
3-8.4.3 Nonpermissible Adjustments.
3-8.5 Duration of Runs, Number of Test Runs, and Number of Readings
3-8.5.1 Duration of Test Runs.
23 3-8.5.2 Number of Test Runs.
3-8.5.3 Number of Readings.
3-8.5.4 Preliminary Test Runs.
24 Section 4 Instruments and Methods of Measurement
4-1 INTRODUCTION
4-2 MEASUREMENT OF ENVIRONMENTAL EFFECTS
4-3 LOCATION OF TEST POINTS
4-3.1 General
4-3.2 Condenser Pressure
4-3.3 Steam Temperature
4-3.4 Steam Quality
25 4-3.5 Atmospheric Pressure
4-3.6 Inlet Air Temperature
4-3.7 Wind Velocity
4-3.8 Condensate Flow
4-3.9 Condensate and Makeup Temperatures
4-3.10 Fan Motor Input Power
4-3.11 Condensate Oxygen Concentration
26 4-4 INSTRUMENTATION AND METHODS OF MEASUREMENT
4-4.1 Condenser Pressure
4-4.2 Steam Temperature
4-4.3 Steam Quality
4-4.4 Atmospheric Pressure
4-4.5 Inlet Air Temperature
4-4.6 Wind
4-4.1-1 Basket Tip
4-4.1-2 Guide Plate
27 4-4.7 Condensate Mass Flow
4-4.8 Condensate and Makeup Temperatures
4-4.9 Fan Motor Input Power
4-4.10 Condensate Oxygen Concentration
28 Section 5 Computation of Results
5-1 GENERAL
5-2 REVIEW OF TEST DATA AND TEST CONDITIONS
5-3 REDUCTION OF TEST DATA
5-3.1 Air-Side Conditions Data Reduction
5-3.2 Steam Side Data Reduction
5-4 ACC DESIGN DATA
29 5-5 PARTICULAR CALCULATIONS AT THE GUARANTEE POINT
5-5.1 Computation of LMTD at Guarantee Conditions
5-5.2 Computation of Number of Transfer Units NTU
5-5.3 Computation of Gamma Factor
5-6 ADJUSTMENT OF TEST DATA TO GUARANTEE CONDITIONS
5-6.1 General
5-6.2 ACC Performance Curves
5-6.3 Adjustment for Steam Quality
5-6.4 Adjustment of Atmospheric Pressure
30 5-6.5 Adjustment of Fan Power
5-6.6 Adjustment of ACC Pressure and Inlet Air Temperature
5-6.7 Computation of Capability
5-6.8 Interpretation of Capability in Terms of ACC Pressure
5-6.9 Condensate Temperature Corrections
5-7 CONDENSATE TEMPERATURE
5-8 OXYGEN CONTENT
5-9 TEST UNCERTAINTY
31 5-10 UNCERTAINTY ANALYSIS
33 Section 6 Report of Results
34 NONMANDATORY APPENDICES
A SAMPLE CALCULATIONS OF PERFORMANCE
A-1 DESIGN DATA
A-2 TEST DATA
A-2.1 Test Conditions
A-2.2 Test Results
A-3 CALCULATIONS
A-3.1 Design Point Calculations
A-3.2 ACC Performance Curves Para. 5-6.2
A-4 CORRECTIONS
A-4.1 Correction for Steam Quality Para. 5-6.3
A-4.2 Correction for Atmospheric Pressure Para. 5Ã6.4
35 A-4.3 Correction for Fan Power Para. 5-6.5
A-4.4 Correction for Condenser Pressure and Inlet Air Temperature Para. 5-6.6
A-4.5 Computation of ACC Capability in Terms of Steam Flow Para. 5-6.7
41 B DESCRIPTION OF PERFORMANCE CURVES
B-1 INTRODUCTION
B-1.1 Description of Curves
B-1.2 Format
B-1.2.1 Primary Format.
B-1.2.2 Alternative Formats.
B-1.2.3 Other Representations — Tabular Data.
B-1.2.4 Other Representations — Equation Format.
47 C UNCERTAINTY ANALYSIS EXAMPLE
C-1 SENSITIVITY FACTORS
51 D DERIVATION OF EXPONENTS mk AND n
D-1 INTRODUCTION OF TERMINOLOGY AND DEFINITIONS
D-2 CORRECTION FACTORS
D-2.1 Exponent mk
52 D-2.2 Exponent n
D-2.3 Derivation of Correction Factor for Atmospheric Pressure, fp
53 D-2.4 Correction for Fan Motor Power, ffp
54 E CALCULATION OF THE STEAM QUALITY AT TEST CONDITIONS
56 F TEST CALCULATIONS FOR DISSOLVED OXYGEN DETERMINATION
F-1 INTRODUCTION
F-2 SAMPLING FREQUENCY
F-3 SAMPLE LOCATION
F-4 SAMPLE METHODS
58 G DATA SHEETS
63 H REPORTING FORM OF RESULTS OF ACC PERFORMANCE TEST
H-1 GENERAL INFORMATION NUMBER OF READINGS
H-2 STEAM AND WATER CONDITIONS NUMBER OF READINGS
H-3 POWER AND AIR NUMBER OF READINGS
64 I PERFORMANCE MONITORING
I-1 INTRODUCTION
I-2 PERFORMANCE MONITORING TEST STRUCTURE
I-3 PARAMETERS TO MONITOR
I-4 MONITORING MEASUREMENTS
65 I-5 CALCULATIONS
67 J ROUTINE PERFORMANCE TEST
J-1 OBJECTIVE
J-2 GUIDING PRINCIPLES
J-3 INSTRUMENTS AND METHODS
J-3.1 Inlet Air Temperature
J-3.2 ACC Pressure
68 K ENVIRONMENTAL EFFECTS
K-1 OBJECTIVES
69 K-2 WIND EFFECTS
81 L ELECTRIC POWER LINE LOSSES
L-1 FAN MOTOR POWER
L-2 LINE LOSS CORRECTION
L-3 EXAMPLE CALCULATION TO DETERMINE LINE LOSS
85 How can you reach us? ItŒs easier than ever!
ASME PTC 30.1 07
$98.04