BS EN 60143-4:2010:2011 Edition
$198.66
Series capacitors for power systems – Thyristors controlled series capacitors
Published By | Publication Date | Number of Pages |
BSI | 2011 | 58 |
IEC 60143-4:2010 specifies testing of thyristor controlled series capacitor (TCSC) installations used in series with transmission lines. This standard also addresses issues that consider ratings for TCSC thyristor valve assemblies, capacitors, and reactors as well as TCSC control characteristics, protective features, cooling system and system operation. This part of IEC 60143 is to be used in conjonction with the following standards: IEC 60143-1:2004, IEC 60143-2:1994 and IEC 60143-3:1998.
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | 1 Scope 2 Normative references |
10 | 3 Terms, definitions and abbreviations 3.1 Abbreviations 3.2 Terms and definitions |
14 | 4 Operating and rating considerations 4.1 General |
15 | Figure 1 – Typical nomenclature of a TCSC installation |
16 | Figure 2 – TCSC subsegment Table 1 – Peak and RMS voltage relationships |
17 | 4.2 TCSC characteristics Figure 3 – TCSC steady state waveforms for control angle α and conduction interval σ |
18 | 4.3 Operating range Figure 4 – TCSC power frequency steady state reactance characteristicsaccording to Equation (1), with λ = 2,5 Figure 5 – Example of TCSC operating range for POD (left) and SSR mitigation (right) |
19 | 4.4 Reactive power rating 4.5 Power oscillation damping (POD) 4.6 SSR mitigation |
20 | 4.7 Harmonics 4.8 Control interactions between TCSCs in parallel lines 4.9 Operating range, overvoltages and duty cycles |
21 | 5 Valve control 5.1 Triggering system Figure 6 – Valve base electronics (VBE) |
22 | 5.2 System aspects 5.3 Normal operating conditions Figure 7 – Valve electronics (VE) |
23 | 5.4 Valve firing during system faults 5.5 Actions at low line current 5.6 Monitoring 6 Ratings 6.1 Capacitor rating |
24 | 6.2 Reactor rating 6.3 Thyristor valve rating |
26 | Figure 8 – Thyristor valve voltage in a TCSC |
27 | 6.4 Varistor rating 6.5 Insulation level and creepage distance 7 Tests |
28 | 7.1 Test of the capacitor |
29 | 7.2 Tests of the TCSC reactor |
30 | 7.3 Tests of thyristor valves |
41 | 7.4 Tests of protection and control system |
43 | 8 Guidance for selection of rating and operation 8.1 General Figure 9 – Typical block diagram of a real time TCSC protection- and control system simulation environment |
44 | 8.2 Thyristor controlled series capacitor |
46 | Figure 10 – Example of operating range diagram for TCSC |
47 | 8.3 Thyristor valves 8.4 Capacitors and reactors |
48 | 8.5 Fault duty cycles for varistor rating Table 2 – Typical external fault duty cycle with unsuccessful high speed auto-reclosing Table 3 – Typical duty cycle for internal fault with successful high speed auto-reclosing |
49 | 8.6 Valve cooling system 8.7 TCSC control and protection Table 4 – Typical duty cycle for internal fault with unsuccessful high speed auto-reclosing |
53 | 8.8 Precommissioning and commissioning tests |
56 | Bibliography |