Photovoltaic pumping systems. Design qualification and performance measurements
Published By | Publication Date | Number of Pages |
BSI | 2011 | 30 |
This International Standard defines the requirements for design, qualification and performance measurements of photovoltaic pumping systems in stand-alone operation. The outlined measurements are applicable for either indoor tests with PV generator simulator or outdoor tests using a real PV generator. This standard applies to systems with motor pump sets connected to the PV generator directly or via a converter (DC to DC or DC to AC). It does not apply to systems with electrical storage unless this storage is only used for the pump start up (< 100 Wh).
The goal is to establish a PV pumping system design verification procedure according to the specific environmental conditions. This Standard addresses the following pumping system design features:
-
Power vs. flow rate characteristics at constant pumping head
-
Pumping head vs. flow rate characteristics at constant speed
-
System design parameters and requirements
-
System specification
-
Documentation requirements
-
System design verification procedure
The object of this standard is to establish requirements in order to be able to verify the system performance characteristics of the PV pumping system. For this purpose the test set-up is outlined, the measurements and deviations to be taken are defined and a checklist for the data mining is established.
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope and object 2 Normative references |
12 | 3 Terms, definitions, system-types and -parameters 3.1 Terms and definitions |
13 | 3.2 System-types and -parameters Tables Table 1 – Categories of PV pumping systems for the purposes of testing |
14 | Figures Figure 1 – Schematic of system types for the purposes of testing (In case C, Vm and Im may be electronically commutated voltage and current) |
15 | 4 Requirements for system components 4.1 General 4.2 Relations to other standards Table 2 – Definition of the parameters |
16 | 5 Performance measurement 5.1 General 5.2 Test set-up |
18 | 5.3 Pumping system performance tests Figure 2 – Example of PV pump test circuit in the lab |
19 | Figure 3 – Example of a P-Q diagram |
20 | Figure 4 – Example of an H-Q diagram for the same pump at different rotational speeds |
21 | 6 Design qualification for a pumping system 6.1 General 6.2 Customer data |
22 | 6.3 System characteristics Table 3 – Pressure in bars for equivalent heads of water |
23 | 6.4 Dimensioning of hydraulic equipment 6.5 Documentation |
24 | 6.6 Design check of the PV pumping system in respect to the daily water volume 6.7 Recording of the measured parameters |
25 | Table 4 – Core and optional parameters to be measured and recorded |
26 | Annex A (informative) Performance diagram, component characteristics and definitions Figure A.1 – System performance for a centrifugal pumping system |