Fibre optic interconnecting devices and passive components. Fibre optic connector product specifications – LC-PC duplex multimode connectors terminated on IEC 60793-2-10 category A1a fibre
Published By | Publication Date | Number of Pages |
BSI | 2014 | 38 |
IEC 62664-1-1:2013 contains the initial, start-of-life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled multimode resilient alignment sleeve LC-PC duplex connector set (plug/adaptor/plug) should meet in order for it to be categorized as an International Standard product. Key words: multimode resilient alignment sleeve LC-PC duplex connector set
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | English CONTENTS |
10 | 1 Scope 2 Normative references |
11 | 3 Description 3.1 General 3.1.1 Intermateability and interoperation 3.1.2 Operating environment 3.1.3 Reliability |
12 | 3.1.4 Quality assurance 3.2 Plug 3.3 Adaptor 3.4 Materials 3.5 Dimensions 3.6 Colour and marking Tables Table 1 – Preferred colour scheme |
13 | 4 Variants 4.1 Terminated plug 4.2 Adaptor 4.3 Identification of variants 5 Dimensional requirements 5.1 Outline dimensions 5.1.1 Plug variants Table 2 – Plug fibre / cable variants with fibre category IEC 60793-2-10 Type A1a Table 3 – Adaptor variants Table 4 – Identification plug fibre/cable variants with fibre category IEC 60793-2-10 Table 5 – Adaptor variants |
14 | Figures Figure 1 – Outline dimensions – Plug |
15 | 5.1.2 Adaptor variants Figure 2 – Outline dimensions – Adaptor (variant number: A01) |
16 | 5.2 Mating face and other limit dimensions 5.2.1 Plug Figure 3 – Duplex adaptor SC cutout – (variant number: A02) |
17 | Figure 4 – Plug connector interface reference planes Figure 5 – Plug connector interface |
18 | Figure 6 – Duplex plug interface Table 6 – Dimensions of the plug connector interface |
19 | 5.2.2 Ferrule endface geometry after termination Figure 7 – Ferrule endface geometry – After termination |
20 | Figure 8 – Ferrule endface geometry – Allowable undercut BK versus ferrule endface radius BF (after termination) |
21 | 5.2.3 Adaptor Figure 9 – Adaptor interface |
22 | Figure 10 – Junior (Jr) Adaptor interface (optional – Note e) of Table 7) |
23 | Figure 11 – Duplex adaptor interface Table 7 – Dimensions of the adaptor connector interface (1 of 2) |
24 | 5.2.4 Pin gauge for adaptor Figure 12 – Pin gauge for adaptor |
25 | 6 Tests 6.1 Sample size 6.2 Test and measurement methods 6.3 Test sequence 6.4 Pass/fail criteria 7 Test report 8 Performance requirements 8.1 Dimensional and marking requirements 8.2 Performance requirements |
26 | Table 8 – Performance requirements (1 of 6) |
32 | Annex A (informative)Reference connector details Table A.1 – Details for reference connector |
33 | Annex B (normative)Sample size and product sourcing requirements Table B.1 – Sample size and product sourcing requirements |
34 | Annex C (normative)Requirements of the launch modal condition Table C.1 – Normative EF requirements for 50 µm core fibre at 850 nm |
35 | Bibliography |