Shopping Cart

No products in the cart.

BSI 23/30475690 DC 2023

$13.70

BS EN IEC 61935-4. Specification for the testing of balanced and coxial information technology cabling – Part 4. Installed balanced single pair cabling as specified in ISO/IEC 11801-1 and related standards

Published By Publication Date Number of Pages
BSI 2023 61
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
8 FOREWORD
10 INTRODUCTION
11 1. Scope
13 3. Terms, definitions and abbreviations
3.1 Acronyms
4. Reference measurement procedures for electrical properties
4.1 General
4.2 Common measurement considerations
4.2.1 Test equipment consideration
4.2.2 Network analyser test requirements
14 4.2.3 Test set-up
4.2.4 Termination of conductor pairs
15 4.2.5 Reference loads for calibration
4.2.6 Test configurations
4.2.7 Coaxial cables and test leads for network analysers
4.2.8 Balanced test leads
4.2.9 Balun requirements
16 4.2.10 Balunless
4.2.11 Network analyser measurement precautions
4.2.12 Data reporting and accuracy
17 4.2.13 Frequency step size
4.2.14 Mixed Mode S-parameters measurements
4.3 DC loop resistance
4.4 Direct current (DC) resistance unbalance
18 4.4.1 Objective
4.4.2 Test method
4.4.3 Test equipment and set-up
4.4.4 Procedure
4.5 Direct current (DC) resistance unbalance between pairs
4.6 Insertion loss
4.6.1 Temperature correction
4.6.2 Uncertainty
4.7 Propagation delay
4.7.1 Objective
4.7.2 Test method
19 4.7.3 Test equipment and set-up
4.7.4 Procedure
4.7.4.1 Calibration
4.7.4.2 Measurement
4.7.4.3 Calculation
4.7.5 Test report
4.7.6 Uncertainty
4.8 Near-end cross-talk (NEXT) and power sum NEXT
4.9 Attenuation to crosstalk ratio, near end (ACR-N) and power sum ACR-N
20 4.10 Far-end cross-talk (FEXT) and power sum FEXT
4.11 Attenuation to crosstalk ratio, far end (ACR-F)
4.12 PS alien near end crosstalk (PS ANEXT – Exogenous crosstalk)
4.12.1 Objective
4.12.2 Test method
4.12.3 Test equipment and set-up
21 4.12.4 Procedure
4.12.4.1 Calibration
22 4.12.4.2 Measurement
4.12.4.3 Calculation
4.12.4.4 Test report
4.12.4.5 Uncertainty
23 4.13 PS attenuation to alien crosstalk ratio, far end crosstalk (PS AACR-F – Exogenous crosstalk)
4.13.1 Objective
4.13.2 Test method
4.13.3 Test equipment and set-up
25 4.13.4 Procedure
4.13.4.1 Calibration
4.13.4.2 Measurement
4.13.4.3 Calculation of PS AACR-F from AFEXT and insertion loss measurements
26 4.13.4.4 Test report
4.13.4.5 Uncertainty
27 4.14 Unbalance attenuation, near end
4.14.1 Uncertainty
4.15 Unbalance attenuation, far end
4.15.1 Uncertainty
4.16 Coupling attenuation
5. Field test measurement requirements for electrical properties
5.1 Introductory remark
28 5.2 Cabling configurations tested
5.3 Field test parameters
5.3.1 General
5.3.2 Optional field test parameters
29 5.3.3 Inspection of workmanship and connectivity testing
5.3.3.1 Visual inspection
5.3.3.2 Wire map
30 5.3.4 Propagation delay
5.3.5 Length
5.3.6 Insertion loss
31 5.3.7 NEXT, power sum NEXT
5.3.8 ACR-N and power sum ACR-N
5.3.9 Return loss
5.3.10 Direct current (DC) loop resistance
5.3.11 Direct current (DC) resistance unbalance between pairs
5.3.12 Alien crosstalk parameters
5.4 Data reporting and accuracy
5.4.1 General
5.4.2 Detailed results
32 5.4.3 Summary results
33 5.4.4 Reporting requirements for power sum alien crosstalk
5.4.5 General
5.4.6 Consistency checks for field testers
5.4.6.1 General
5.4.6.2 Repeatability of tests on a reference link
5.4.6.3 Repeatability of tests by testing the same link in opposite directions
5.4.7 Evaluation of consistency tests
34 5.4.8 Administration system applicability
5.4.9 Test equipment adapter cords for link testing
5.4.10 User cords and channel testing
6. Field tester measurement accuracy requirements
6.1 General
36 6.2 Measurement accuracy specifications common to level SP-I, SP-II, and level SP-III field testers
37 6.3 Accuracy performance requirements for Level SP-I field testers
39 6.4 Accuracy performance requirements for level SP-II field testers
41 6.5 Accuracy performance requirements for level SP-III field testers
43 6.6 Field tester requirements applicable to alien crosstalk measurements
6.7 Accuracy performance requirements for level V field testers
6.8 Accuracy performance requirements for level VI field testers
44 6.9 Field tester requirements applicable to alien crosstalk measurements
6.10 Procedures for determining field tester parameters
6.11 Measurement error models
6.12 Network analyser measurement comparisons
45 Annex A (informative) Uncertainty and variability of field test results
A.1 General
A.2 Marginal results reporting
A.3 Nominal accuracy
46 A.4 Variability in link measurements not included in the measurement accuracy
A.5 Variability in channel measurements
A.6 Field tester accuracy checks
A.6.1 General
A.6.2 Manipulating cords of link adapter
47 A.6.3 Exchanging adapters to main and remote field tester units
A.6.4 Location of main and remote field tester units
A.6.5 Use of previously characterized links
A.6.6 Use separately characterized links using laboratory equipment
A.6.7 Guidelines for correct installation testing
48 Annex B (informative) Reference laboratory test configuration for alien crosstalk testing
B.1 General
B.2 Test parameters
B.3 Link and channel construction
49 B.4 Determination of number of disturbing links or channels
50 B.5 Computation of results
B.5.1 General
B.5.2 Computation of Class I and Class II results
B.5.2.1 Class I and Class II PSANEXT calculation procedure
B.5.2.2 Class I and Class II PSAACRF calculation procedure
51 B.6 Test report
52 Annex C (informative) General information on power sum alien crosstalk performance of installations
53 Annex D (informative) Baluns
D.1 General
54 Annex E (normative) Requirements for field testing of alien crosstalk
E.1 Power sum alien crosstalk
E.1.1 Objective
E.1.2 Test method
E.1.3 Test equipment and set-up
E.1.4 Measuring ANEXT loss
55 E.1.5 Measuring AFEXT loss
56 E.1.6 Procedure
E.1.6.1 Calibration
E.1.6.2 Calculation of PS ANEXT and PS AACR-F from measured data
E.1.6.3 Significance condition testing
E.1.6.4 Length normalization
E.1.6.5 Computing the PS ANEXT or PS AFEXT results between a disturbed and disturbing links
58 E.1.6.6 Applying the correction for the measurement floor
E.1.7 Selection of test ports
E.1.7.1 Selection of disturbed links
59 E.1.7.2 Selection of disturbing links
E.1.7.2.1 General
E.1.7.2.2 Procedure
60 E.1.8 Test report
E.1.9 Uncertainty of PS alien crosstalk measurements
61 Bibliography
BSI 23/30475690 DC 2023
$13.70