Shopping Cart

No products in the cart.

BSI PD CEN/TR 17167:2023:2024 Edition

$215.11

Communication system for meters. Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information

Published By Publication Date Number of Pages
BSI 2024 94
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.

PDF Catalog

PDF Pages PDF Title
2 undefined
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Symbols and abbreviations
4.1 Abbreviations
10 4.2 Symbols
5 Overview
12 Annex A (informative)Examples
A.1 General
A.2 Example for an RSP-UD
A.3 Example baud rate switch
13 A.4 Example application select with subcode
A.5 Writing data to a slave
14 A.6 Configuring M-Bus data output
A.6.1 General
15 A.6.2 Selection of data records with special data field
16 A.6.3 Selection of data records with object action code
A.6.4 Deselection of data records
17 A.7 FCB and selection
A.7.1 FCB-implementation slave
18 A.7.2 FCB-implementation master
19 A.8 Use of the fabrication number
20 Annex B (informative)Secondary search – Instructions for implementation of wildcard search
22 Annex C (informative)Consumer feedback for smart metering applications
C.1 General
C.2 Resolution of required values and accuracy of time information
C.2.1 General
C.2.2 Resolution in case of transmission of extra data points for power/flow rate
23 C.2.3 Resolution in case of non-transmission of extra data points for power/flow rate
C.2.3.1 General
24 C.2.3.2 Assumptions on time information for wireless connections
C.2.4 Transmission on request
25 Annex D (informative)Installation and registration
D.1 General
26 D.2 Registration with meter support
D.2.1 Introduction
D.2.2 RF-Link feedback
D.2.3 Registration feedback
D.3 Registration without meter support
28 Annex E (informative)M-Bus data container
E.1 Explanation
E.2 Definition
29 E.3 Example
30 Annex F (informative)Datagram examples for the M-Bus and the wM-Bus
F.1 Colour coding of the datagram examples
F.2 Security mode 5 example
34 F.3 Security mode 7 example
42 F.4 Security mode 8 example
46 F.5 Security Mode 9 example
F.5.1 General
47 F.5.2 Example input vectors
48 F.5.3 Example Mode 9 on SND-NR datagram
50 F.5.4 Example applying Mode 9 on RSP-UD datagram
53 F.6 Security mode 10 example
59 F.7 Special messages
F.7.1 Installation procedure with a special installation message
65 F.7.2 Send a command with an acknowledge
70 F.7.3 Request of the selected data
74 F.7.4 Reset of the link by a SND-NKE
76 F.7.5 Key transfer according SITP
81 F.7.6 Transfer secured application data according SITP
86 Annex G (informative)Descriptors
G.1 General
G.2 Storage descriptors
G.2.1 Storage interval descriptor
87 G.2.2 Storage range descriptor
G.3 Subunit descriptor
88 G.4 Tariff descriptor
89 G.5 Examples
G.5.1 Example: Storage descriptor
91 G.5.2 Example: Subunit descriptor
G.5.3 Example: Tariff descriptor
BSI PD CEN/TR 17167:2023
$215.11