FL ResidentialCode 2010
$62.29
Florida Building Code, Residential
Published By | Publication Date | Number of Pages |
FL | 2010 | 767 |
This is a fully integrated code based on the 2009 IRC.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2010 FLORIDA BUILDING CODE: RESIDENTIAL |
2 | FLORIDA BUILDING CODE 2010 RESIDENTIAL TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
14 | PART I – ADMINISTRATIVE CHAPTER 1 SCOPE AND ADMINISTRATION PART I—SCOPE AND APPLICATION SECTION R101 GENERAL SECTION R102 APPLICABILITY RESERVED PART II—ADMINISTRATION AND ENFORCEMENT SECTION R103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIALRESERVED SECTION R105 PERMITS RESERVED SECTION R106 CONSTRUCTION DOCUMENTS RESERVED SECTION R107 TEMPORARY STRUCTURES AND USES RESERVED SECTION R108 FEES RESERVED SECTION R109 INSPECTIONSRESERVED SECTION R110 CERTIFICATE OF OCCUPANCY RESERVED SECTION R111 SERVICE UTILITIES RESERVED SECTION R112 BOARD OF APPEALS RESERVED SECTION R113 VIOLATIONS RESERVED |
15 | SECTION R114 STOP WORK ORDER RESERVED |
16 | PART II – DEFINITIONS CHAPTER 2 DEFINITIONS SECTION R201 GENERAL SECTION R202 DEFINITIONS |
32 | PART III – BUILDING PLANNING AND CONSTRUCTION CHAPTER 3 BUILDING PLANNING SECTION R301 DESIGN CRITERIA TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA |
33 | FIGURE R301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES ( F) |
34 | TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)a |
35 | TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2) TABLE R301.2(4) GARAGE DOOR LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B |
36 | FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETE |
37 | FIGURE R301.2(4) ULTIMATE DESIGN WIND SPEEDS, Vult |
38 | FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP |
39 | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES |
41 | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULEFOR WOOD STRUCTURAL PANELS TABLE R301.2.1.3 WIND SPEEDS CONVERSIONS |
44 | FIGURE R301.3 DETERMINING NUMBER OF STORIES ABOVE THE FOUNDATION |
45 | TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS |
46 | SECTION R302 FIRE-RESISTANT CONSTRUCTION TABLE R302.1 EXTERIOR WALLS |
48 | TABLE R302.6 DWELLING/GARAGE SEPARATION |
50 | SECTION R303 LIGHT, VENTILATION AND HEATING |
51 | SECTION R304 MINIMUM ROOM AREAS SECTION R305 CEILING HEIGHT |
52 | SECTION R306 SANITATION SECTION R307 TOILET, BATH AND SHOWER SPACES SECTION R308 GLAZING |
53 | FIGURE R307.1 MINIMUM FIXTURE CLEARANCES |
54 | TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201 TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1 |
56 | SECTION R309 GARAGES AND CARPORTS SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS |
57 | SECTION R311 MEANS OF EGRESS |
59 | SECTION R312 GUARDS |
60 | SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS RESERVED SECTION R314 SMOKE ALARMS |
61 | SECTION R315 CARBON MONOXIDE ALARMS SECTION R316 FOAM PLASTIC |
63 | SECTION R317 PROTECTION OF WOOD AND WOOD BASED PRODUCTS AGAINST DECAY |
64 | SECTION R318 PROTECTION AGAINST TERMITES |
65 | SECTION R319 SITE ADDRESS |
66 | SECTION R320 ACCESSIBILITY SECTION R321 ELEVATORS AND PLATFORM LIFTS SECTION R322 FLOOD-RESISTANT CONSTRUCTION |
69 | SECTION R323 STORM SHELTERS SECTION 324 AIRPORT NOISE |
70 | CHAPTER 4 FOUNDATIONS SECTION R401 GENERAL TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALS SECTION R402 MATERIALS |
71 | TABLE R401.1 FOUNDATION UPLIFT LIGHT STEEL AND WOOD FRAME BUILDINGS IN EXPOSURE B |
72 | TABLE R401.1 (continued) FOUNDATION UPLIFT LIGHT STEEL AND WOOD FRAME BUILDINGS IN EXPOSURE C |
73 | TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SECTION R403 FOOTINGS |
74 | TABLE R403.1 MINIMUM WIDTH OF CONCRETE, PRECAST OR MASONRY FOOTINGS |
75 | FIGURE 403.1(1) CONCRETE AND MASONRY FOUNDATION DETAILS |
76 | FIGURE R403.1(1)— continued |
77 | FIGURE R403.1(1)—continued |
78 | FIGURE R403.1(1)—continued |
79 | FIGURE R403.1(1)—continued |
80 | FIGURE R403.1(1)—continued |
81 | FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION |
82 | FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION |
83 | TABLE R403.1.2 FOUNDATION UPLIFT DESIGN DETAILS FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES |
84 | FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING SECTION R404 FOUNDATION AND RETAINING WALLS |
85 | TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS |
86 | TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLS |
87 | TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 5 INCHES |
88 | TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 6.75 INCHES |
89 | TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d > 8.75 INCHES |
90 | TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
91 | TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS |
92 | TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS |
93 | TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS |
94 | TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS |
95 | TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS |
96 | TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLS |
97 | TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
98 | TABLE R404.1.2(9) —continued MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
101 | FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS |
102 | TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION |
103 | SECTION R405 FOUNDATION DRAINAGE |
104 | TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING |
105 | SECTION R407 COLUMNS SECTION R408 UNDER-FLOOR SPACE |
108 | CHAPTER 5 FLOORS SECTION R501 GENERAL SECTION R502 WOOD FLOOR FRAMING |
110 | FIGURE R502.1.5 CUTTING, NOTCHING AND DRILLING |
111 | SECTION R503 FLOOR SHEATHING TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa |
112 | TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT |
113 | SECTION R504 PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND) SECTION R505 STEEL FLOOR FRAMING RESERVED SECTION R506 CONCRETE FLOORS (ON GROUND) |
116 | CHAPTER 6 WALL CONSTRUCTION SECTION R601 GENERAL SECTION R602 WOOD WALL FRAMING |
117 | FIGURE R602.1.4(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS |
118 | FIGURE R602.1.4(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS |
119 | FIGURE R602.1.4.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING |
121 | SECTION R603 STEEL WALL FRAMING RESERVED SECTION R604 WOOD STRUCTURAL PANELS |
122 | SECTION R605 PARTICLEBOARD SECTION R606 GENERAL MASONRY CONSTRUCTION |
123 | TABLE R606.9.2 LAP SPLICE LENGTHS |
124 | FIGURE R606.9.9A CONTINUITY OF REINFORCEMENT ONE STORY MASONRY WALL |
125 | FIGURE R606.9.9B CONTINUITY OF FIRST AND SECOND FLOOR VERTICAL WALL REINFORCEMENT |
126 | TABLE R606.15.1 MINIMUM CORROSION PROTECTION SECTION R607 UNIT MASONRY |
127 | TABLE R607.1 MORTAR PROPORTIONS SECTION R608 MULTIPLE WYTHE MASONRY |
128 | SECTION R609 GROUTED MASONRY |
129 | TABLE R609.1.1 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION TABLE R609.1.2 GROUT SPACE DIMENSIONS AND POUR HEIGHTS |
130 | TABLE R609.2.2C BOND BEAM AREA OF STEEL PROVIDED IN2/FT |
131 | FIGURE R609.2.4 CORNER CONTINUITY OF BOND BEAM AND WALL REINFORCEMENT FIGURE R609.2.5 CHANGES IN BOND BEAM HEIGHT |
132 | TABLE R609.2.2A-1 GRADE 60 EXPOSURE B ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN |
133 | TABLE R609.2.2A-2 GRADE 60 ROOF EXPOSURE C ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN |
134 | TABLE R609.2.2A-3 GRADE 40 EXPOSURE B ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN |
135 | TABLE R609.2.2A-4 GRADE 40 EXPOSURE C ROOF DIAPHRAGM CHORD TENSION BOND BEAM STEEL AREA, IN |
136 | TABLE R609.2.2B-1 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN |
137 | TABLE R609.2.2B-2 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN |
138 | TABLE R609.2.2B-3 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN |
139 | TABLE R609.2.2B-4 GRADE 60 AREA OF STEEL REQUIRED IN BOND BEAM FOR UPLIFT BENDING, IN |
140 | TABLE R609.2.2B-5 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
141 | TABLE R609.2.2B-6 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
142 | TABLE R609.2.2B-7 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
143 | TABLE R609.2.2B-8 GRADE 40 AREA BOND BEAM/LINTEL UPLIFT STEEL DESIGN |
144 | TABLE R609.3.3A-1 GRADE 60 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 5 BARS |
145 | TABLE R609.3.3A-2 GRADE 60 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 4 BARS |
146 | TABLE R609.3.3A-3 GRADE 40 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 5 BARS |
147 | TABLE R609.3.3A-4 GRADE 40 SINGLE STORY AND TOP STORY WALLS PARALLEL TO RIDGE VERTICAL REINFORCEMENT SPACING NO. 4 BARS |
148 | TABLE R609.3.3B-1 GRADE 60 MAXIMUM SPACING OF NO. 5 (5/8 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
149 | TABLE R609.3.3B-2 GRADE 60 MAXIMUM SPACING OF NO. 4 (1/2 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
150 | TABLE R609.3.3B-3 GRADE 40 MAXIMUM SPACING OF NO. 5 (5/8 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
151 | TABLE R609.3.3B-4 GRADE 40 MAXIMUM SPACING OF NO. 4 (1/2 IN.) VERTICAL REINFORCEMENT AT CONTINUOUS CONCRETE OR MASONRY LOWER STORIES OF MULTISTORY AND GABLE ENDS SINGLE STORY OR TOP STORY OF MULTISTORY, FEET |
152 | TABLE R609.4 AWOOD GABLE BRACE NAILING TABLE R609.4B WOOD GABLE STUD CONNECTOR LOADS |
153 | TABLE R609.4.4 ANCHOR BOLT SPACING FOR ATTACHING 2 x 4 MINIMUM WOOD NAILER TO RAKE BEAM |
154 | FIGURE R609.4 GABLE END BRACING FOR MASONRY WALLS NOT CONTINUOUS TO THE ROOF DIAPHRAGM SECTION R610 GLASS UNIT MASONRY |
155 | FIGURE R609.4.1 CONTINUOUS GABLE ENDWALL REINFORCEMENT ONE AND MULTISTORY |
156 | FIGURE R609.4.5 GABLE OVERHANG |
157 | TABLE R609.5.1A GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE ≤ 23° |
158 | TABLE R609.5.1B GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE 30° |
159 | TABLE R609.5.1C GRADE 60 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE 45° |
160 | TABLE R609.5.1D GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 23° |
161 | TABLE R609.5.1E GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 30° |
162 | TABLE R609.5.1F GRADE 60 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 45° |
163 | TABLE R609.5.1G GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE ≤ 23° |
164 | TABLE R609.5.1H GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT ROOF ANGLE ≤ 23° |
165 | TABLE R609.5.1I GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE 30° |
166 | TABLE R609.5.1J GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT ROOF ANGLE 30° |
167 | TABLE R609.5.1K GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 4 REINFORCEMENT ROOF ANGLE 45° |
168 | TABLE R609.5.1L GRADE 40 REQUIRED SHEARWALL LENGTH PARALLEL TO RIDGE NO. 5 REINFORCEMENT ROOF ANGLE 45° |
169 | TABLE R609.5.1M GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTHROOF ANGLE ≤ 23° |
170 | TABLE R609.5.1N GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE ≤ 23° |
171 | TABLE R609.5.1O GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 30° |
172 | TABLE R609.5.1P GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 30° |
173 | TABLE R609.5.1Q GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 4 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 45° |
174 | TABLE R609.5.1R GRADE 40 REQUIRED SHEARWALL LENGTH PERPENDICULAR TO RIDGE NO. 5 REINFORCEMENT PER FOOT OF BUILDING LENGTH ROOF ANGLE 45° |
175 | TABLE R609.5.3 ATOTAL SHEAR AT TOP OF TOP STORY WALL1,2 |
176 | TABLE R609.5.3B TRANSVERSE CONNECTOR LOAD (F2)1, 2 FIGURE R609.5.3 TYPICAL ROOF TO WALL CONNECTIONS |
177 | TABLE R609.5.4 END WALL ROOF SHEAR PER FOOT OF BUILDING LENGTH SECTION R611 EXTERIOR CONCRETE WALL CONSTRUCTION |
178 | TABLE R609.6.1.2(1) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY OF 6-INCH- OR 8-INCH-THICK PRE-ENGINEERED ASSEMBLIES SPANNING OPENINGS OF ONE STORY AND TOP STORY OF MULTI-STORY BUILDINGS |
179 | TABLE R609.6.1.2(2) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM |
180 | TABLE R609.6.1.2(3) SUPERIMPOSED LOADS MINIMUM RATED LOAD CAPACITY 8-INCH-THICK PREENGINEERED ASSEMBLIES SPANNING OPENINGS OF BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOW CORE FLOOR SYSTEM |
181 | TABLE R609.6.2.1(1) MAXIMUM CLEAR SPAN CAPACITY OF CONTINUOUS BOND BEAMS ACTING AS LINTELS ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS |
182 | TABLE R609.6.2.1(2) MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING AS LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM |
183 | TABLE R609.6.2.1(3) MAXIMUM CLEAR SPAN OF CONTINUOUS BOND BEAMS ACTING LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOW CORE SECOND FLOOR |
184 | TABLE R609.6.3.2(1) COMBINED BOND BEAM/LINTELS ONE STORY AND TOP STORY OF MULTISTORY BUILDINGS |
185 | TABLE R609.6.3.2(2) COMBINED BOND BEAM/LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—WOOD FLOOR SYSTEM |
186 | TABLE R609.6.3.2(3) COMBINED BOND BEAM/LINTELS BOTTOM STORY OF TWO-STORY BUILDINGS, SECOND AND BOTTOM STORIES OF THREE-STORY BUILDINGS—HOLLOWCORE FLOOR SYSTEM |
187 | FIGURE R610.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE FIGURE R611.3(1) FLAT WALL SYSTEM |
188 | TABLE R611.3 DIMENSIONAL REQUIREMENTS FOR WALLS FIGURE R611.3(2) WAFFLE-GRID WALL SYSTEM FIGURE R611.3(3) SCREEN-GRID WALL SYSTEM |
190 | TABLE R611.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS FIGURE R611.5.4(1) LAP SPLICES |
191 | FIGURE R611.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION FIGURE R611.5.4(3) STANDARD HOOKS |
192 | TABLE R611.5.4(2) MAXIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEEL |
194 | FIGURE R611.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE FIGURE R611.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST-STORY AND LIGHT-FRAMED SECOND-STORY |
195 | FIGURE R611.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY FIGURE R611.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON GROUND FOOTING |
196 | TABLE R611.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS EQUATION R611.1 |
197 | TABLE R611.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS |
198 | TABLE R611.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS |
199 | TABLE R611.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS |
200 | TABLE R611.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORY |
201 | TABLE R611.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO-STORY |
202 | TABLE R611.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORY |
203 | TABLE R611.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORY |
204 | TABLE R611.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE |
205 | TABLE R611.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO-STORY |
206 | FIGURE R611.7(1) MINIMUM SOLID WALL LENGTH |
207 | FIGURE R611.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL |
208 | TABLE R611.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa FIGURE R611.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS |
209 | TABLE R611.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEET |
210 | TABLE R611.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLS |
211 | EQUATION R611-2 |
212 | FIGURE R611.8(1) REINFORCEMENT OF OPENINGS |
213 | FIGURE R611.8(2) LINTEL FOR FLAT WALLS FIGURE R611.8(3) LINTELS FOR WAFFLE-GRID WALLS |
214 | FIGURE R611.8(4) LINTELS FOR SCREEN-GRID WALLS |
215 | TABLE R611.8(1) LINTEL DESIGN LOADING CONDITIONS |
216 | TABLE R611.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
217 | TABLE R611.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
218 | TABLE R611.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS a, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
219 | TABLE R611.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
220 | TABLE R611.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
221 | TABLE R611.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
222 | TABLE R611.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLS a, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
223 | TABLE R611.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
224 | TABLE R611.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET |
225 | TABLE R611.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET |
226 | TABLE R611.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
227 | TABLE R611.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET |
228 | TABLE R611.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET |
229 | TABLE R611.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS |
230 | TABLE R611.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, hROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET TABLE R611.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS |
232 | FIGURE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
233 | TABLE R611.9(1) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
234 | FIGURE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL FRAMING PARALLEL |
235 | TABLE R611.9(2) WOOD FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
236 | FIGURE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
237 | TABLE R611.9(3) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
238 | FIGURE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING PARALLEL |
239 | TABLE R611.9(4) WOOD FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
240 | FIGURE R611.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
241 | TABLE R611.9(5) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR |
242 | FIGURE R611.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL |
243 | TABLE R611.9(6) COLD-FORMED STEEL FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa |
244 | FIGURE R611.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
245 | TABLE R611.9(7) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
246 | FIGURE R611.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
247 | TABLE R611.9(8) COLD-FORMED STEEL FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
248 | FIGURE R611.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL FRAMING PERPENDICULAR |
249 | TABLE R611.9(9) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
250 | FIGURE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
251 | TABLE R611.9(10) WOOD FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
252 | FIGURE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR |
253 | TABLE R611.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULARa |
254 | FIGURE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
255 | TABLE R611.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL |
256 | SECTION R612 EXTERIOR WINDOWS AND DOORS |
257 | TABLE R612.8 MINIMUM TEST SIZES, INCLUDING FRAMING |
260 | SECTION R613 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION TABLE R613.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE TABLE R613.3.2 MINIMUM PROPERTIESa FOR WOOD STRUCTURAL PANEL FACING MATERIAL USED IN SIP WALLS |
261 | FIGURE R613.4 SIP WALL PANEL |
262 | TABLE R613.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP LIGHT-FRAME ROOF ONLY (inches) TABLE R613.5(2) MINIMUM THICKNESS FOR SIP WALLS SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF (inches) |
263 | FIGURE R613.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS FIGURE R613.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS |
264 | FIGURE R613.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION FIGURE R613.5(4) SIP WALL TO WALL PLATFORM FRAME CONNECTION |
265 | FIGURE R613.5(5) SIP WALL TO WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only) FIGURE R613.5.1 SIP WALL FRAMING CONFIGURATION |
266 | FIGURE R613.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT FIGURE R613.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS |
267 | FIGURE R613.9 SIP CORNER FRAMING DETAIL TABLE R613.10 MAXIMUM SPANS FOR 117/8 INCH DEEP SIP HEADERS (feet) |
268 | SECTION R614 COMBINED CONCRETE, MASONRY, OR ICF AND WOOD EXTERIOR WALL CONSTRUCTION SECTION R615 IMPACT-RESISTANT COVERINGS |
269 | FIGURE R614.3(1) DIRECT TRUSS TO CONCRETE, MASONRY OR ICF WALL CONNECTION FOR GYPSUM BOARD CEILING DIAPHRAGM FIGURE R614.3(2) DIRECT TRUSS TO CONCRETE, MASONRY OR ICF WALL FOR GYPSUM BOARD CEILING DIAPHRAGM |
270 | SECTION R616 SOFFIT |
272 | CHAPTER 7 WALL COVERING SECTION R701 GENERAL TABLE R702.1(1) THICKNESS OF PLASTER TABLE R702.1(2) GYPSUM PLASTER PROPORTIONS |
273 | TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD |
274 | SECTION R702 INTERIOR COVERING |
275 | TABLE R702.3.7 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES SECTION R703 EXTERIOR COVERING |
277 | TABLE R703.3.3(1) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING ATTACHMENT EXPOSURE CATEGORY B |
278 | TABLE R703.3.3(2) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING ATTACHMENT EXPOSURE CATEGORY C |
279 | TABLE R703.3.3(3) SPECIFIC GRAVITIES OF SOLID SAWN LUMBER |
280 | TABLE R703.3.4(1) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING MINIMUM THICKNESS EXPOSURE CATEGORY B TABLE R703.3.4(2) WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL SIDING MINIMUM THICKNESS EXPOSURE CATEGORY C |
281 | TABLE R703.4 WEATHER–RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS |
282 | TABLE R703.5.2 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c (Dimensions are in inches) |
283 | FIGURE R703.7 MASONRY VENEER WALL DETAILS |
284 | FIGURE R703.7— continued MASONRY VENEER WALL DETAILS |
285 | FIGURE R703.7.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES |
286 | FIGURE R703.7.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS |
287 | TABLE R703.7.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER FIGURE R703.7.3.2 MASONRY VENEER OPENING |
290 | TABLE R703.13 MINIMUM THICKNESS OF WEATHER COVERINGS SECTION R704 INSPECTION FOR TERMITES |
292 | CHAPTER 8 ROOF-CEILING CONSTRUCTION SECTION R801 GENERAL SECTION R802 WOOD ROOF FRAMING |
295 | TABLE R802.1.9 WIND UPLIFT FORCES |
296 | SECTION R803 ROOF SHEATHING TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING |
297 | FIGURE R803.2.3.1 ROOF SHEATHING NAILING ZONES SECTION R804 STEEL ROOF FRAMING RESERVED SECTION R805 CEILING FINISHES SECTION R806 ROOF VENTILATION |
298 | TABLE R806.4 INSULATION FOR CONDENSATION CONTROL SECTION R807 ATTIC ACCESS |
300 | CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL SECTION R902 ROOF CLASSIFICATION SECTION R903 WEATHER PROTECTION TABLE R903.2.1 METAL FLASHING MATERIAL |
301 | SECTION R904 MATERIALS SECTION R905 REQUIREMENTS FOR ROOF COVERINGS |
302 | TABLE R905.2.6.1 WIND RESISTANCE OF ASPHALT SHINGLES |
304 | TABLE 905.4.4 METAL ROOF COVERINGS |
305 | TABLE R905.6.5 SLATE SHINGLE HEADLAP TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE R905.7.5 WOOD SHINGLE AND SHAKE INSTALLATION |
306 | TABLE R905.7.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
307 | TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS TABLE R905.8.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
308 | TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS |
309 | TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS |
310 | SECTION R906 ROOF INSULATION TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION R907 REROOFING |
312 | CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES |
313 | TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS |
314 | FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS |
315 | FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES SECTION R1002 MASONRY HEATERS |
316 | SECTION R1003 MASONRY CHIMNEYS |
317 | TABLE R1003.14(1) NET CROSS–SECTIONAL AREA OF ROUND FLUE SIZES |
318 | TABLE R1003.14(2) NET CROSS–SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES |
319 | FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES |
320 | TABLE R1003.20 CRICKET DIMENSIONS FIGURE R1003.20 CHIMNEY CRICKET SECTION R1004 FACTORY-BUILT FIREPLACES SECTION R1005 FACTORY-BUILT CHIMNEYS |
321 | SECTION R1006 EXTERIOR AIR SUPPLY |
322 | PART IV – ENERGY CONSERVATION CHAPTER 11 ENERGY EFFICIENCY SECTION N1101 GENERAL |
324 | PART V – MECHANICAL CHAPTER 12 MECHANICAL ADMINISTRATION SECTION M1201 GENERAL SECTION M1202 EXISTING MECHANICAL SYSTEMS |
326 | CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL SECTION M1302 APPROVAL SECTION M1303 LABELING OF APPLIANCES SECTION M1304 TYPE OF FUEL SECTION M1305 APPLIANCE ACCESS |
328 | SECTION M1306 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION SECTION M1307 APPLIANCE INSTALLATION |
329 | TABLE M1306.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION |
330 | FIGURE M1306.1 REDUCED CLEARANCE DIAGRAM FIGURE M1306.2 WALL PROTECTOR CLEARANCE REDUCTION SYSTEM |
331 | SECTION M1308 MECHANICAL SYSTEMS INSTALLATION |
332 | CHAPTER 14 HEATING AND COOLING EQUIPMENT SECTION M1401 GENERAL SECTION M1402 CENTRAL FURNACES SECTION M1403 HEAT PUMP EQUIPMENT SECTION M1404 REFRIGERATION COOLING EQUIPMENT SECTION M1405 BASEBOARD CONVECTORS SECTION M1406 RADIANT HEATING SYSTEMS |
333 | SECTION M1407 DUCT HEATERS SECTION M1408 VENTED FLOOR FURNACES SECTION M1409 VENTED WALL FURNACES |
334 | SECTION M1410 VENTED ROOM HEATERS SECTION M1411 HEATING AND COOLING EQUIPMENT |
335 | SECTION M1412 ABSORPTION COOLING EQUIPMENT SECTION M1413 EVAPORATIVE COOLING EQUIPMENT SECTION 1414 FIREPLACE STOVES SECTION M1415 MASONRY HEATERS |
336 | CHAPTER 15 EXHAUST SYSTEMS SECTION M1501 GENERAL SECTION M1502 CLOTHES DRYER EXHAUST TABLE M1502.4.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
337 | SECTION M1503 RANGE HOODS SECTION M1504 INSTALLATION OF MICROWAVE OVENS SECTION M1505 OVERHEAD EXHAUST HOODS SECTION M1506 EXHAUST DUCTS SECTION M1507 MECHANICAL VENTILATION |
338 | TABLE M1507.3 MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS |
340 | CHAPTER 16 DUCT SYSTEMS SECTION M1601 DUCT CONSTRUCTION TABLE M1601.1.1(2) GAGES OF METAL DUCTS AND PLENUMS USED FOR HEATING OR COOLINGa |
341 | TABLE M1601.1.1(1) CLASSIFICATION OF FACTORY-MADE AIR DUCTS |
343 | TABLE M1601.4 DUCT SYSTEM CONSTRUCTION AND SEALING |
344 | TABLE M1601.4—continued DUCT SYSTEM CONSTRUCTION AND SEALING |
345 | TABLE M1601.4—continued DUCT SYSTEM CONSTRUCTION AND SEALING |
347 | SECTION M1602 RETURN AIR |
348 | CHAPTER 17 COMBUSTION AIR SECTION M1701 GENERAL |
350 | CHAPTER 18 CHIMNEYS AND VENTS SECTION M1801 GENERAL SECTION M1802 VENT COMPONENTS |
351 | SECTION M1803 CHIMNEY AND VENT CONNECTORS TABLE M1803.2 THICKNESS FOR SINGLE-WALL METAL PIPE CONNECTORS TABLE M1803.3.4 CHIMNEY AND VENT CONNECTOR CLEARANCES TO COMBUSTIBLE MATERIALS |
352 | SECTION M1804 VENTS TABLE M1804.1 VENT SELECTION CHART SECTION M1805 MASONRY AND FACTORY-BUILT CHIMNEYS |
354 | CHAPTER 19 SPECIAL FUEL-BURNING EQUIPMENT SECTION M1901 RANGES AND OVENS SECTION M1902 SAUNA HEATERS SECTION M1903 STATIONARY FUEL CELL POWER PLANTS SECTION M1904 GASEOUS HYDROGEN SYSTEMS |
356 | CHAPTER 20 BOILERS AND WATER HEATERS SECTION M2001 BOILERS SECTION M2002 OPERATING AND SAFETY CONTROLS SECTION M2003 EXPANSION TANKS SECTION M2004 WATER HEATERS USED FOR SPACE HEATING SECTION M2005 WATER HEATERS |
357 | TABLE M2003.2 EXPANSION TANK MINIMUM CAPACITYa FOR FORCED HOT-WATER SYSTEMS SECTION M2006 POOL HEATERS |
358 | CHAPTER 21 HYDRONIC PIPING SECTION M2101 HYDRONIC PIPING SYSTEMS INSTALLATION SECTION M2102 BASEBOARD CONVECTORS SECTION M2103 FLOOR HEATING SYSTEMS |
359 | TABLE M2101.1 HYDRONIC PIPING MATERIALS |
360 | TABLE M2101.9 HANGER SPACING INTERVALS SECTION M2104 LOW TEMPERATURE PIPING |
361 | SECTION M2105 GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING |
362 | CHAPTER 22 SPECIAL PIPING AND STORAGE SYSTEMS SECTION M2201 OIL TANKS SECTION M2202 OIL PIPING, FITTING AND CONNECTIONS SECTION M2203 INSTALLATION |
363 | SECTION M2204 OIL PUMPS AND VALVES |
364 | CHAPTER 23 SOLAR SYSTEMS SECTION M2301 SOLAR ENERGY SYSTEMS |
366 | PART VI – FUEL GAS CHAPTER 24 FUEL GAS SECTION G2401 (101) GENERAL SECTION G2402 (201) GENERAL SECTION G2403 (202) GENERAL DEFINITIONS |
372 | SECTION G2404 (301) GENERAL |
373 | SECTION G2405 (302) STRUCTURAL SAFETY SECTION G2406 (303) APPLIANCE LOCATION SECTION G2407 (304) COMBUSTION, VENTILATION AND DILUTION AIR |
374 | FIGURE G2407.5.3 (304.5.3) ALL AIR FROM INSIDE THE BUILDING EQUATION 24-1 FIGURE G2407.6.2 (304.6.2 )SINGLE COMBUSTION AIR OPENING,ALL AIR FROM OUTDOORS (see Section G2407.6.2) EQUATION 24-2 |
375 | FIGURE G2407.6.1(1) [304.6.1(1)] ALL AIR FROM OUTDOOR-INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC FIGURE G2407.6.1(2) [304.6.1(2)] ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC |
376 | FIGURE G2407.6.1(3) [304.6.1(3)] ALL AIR FROM OUTDOORS |
377 | SECTION G2408 (305) INSTALLATION |
378 | FIGURE G2409.2(1) [308.2(1)] EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTORS FIGURE G2409.2(2) [308.2(2)] WALL PROTECTOR CLEARANCE REDUCTION SYSTEM |
379 | FIGURE G2409.2(3) [308.2(3)] MASONRY CLEARANCE REDUCTION SYSTEM SECTION G2409 (308) CLEARANCE REDUCTION |
380 | TABLE G2409.2 (308.2)a through k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION |
381 | SECTION G2410 (309) ELECTRICAL SECTION G2411 (310) ELECTRICAL BONDING SECTION G2412 (401) GENERAL |
382 | SECTION G2413 (402) PIPE SIZING TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES |
383 | TABLE G2413.4 (1) [402.4(2)] SCHEDULE 40 METALLIC PIPE |
384 | TABLE G2413.4(2) [402.4(3)] SCHEDULE 40 METALLIC PIPE |
385 | TABLE G2413.4(3) [402.4(7)] SEMIRIGID COPPER TUBING |
386 | TABLE G2413.4(4) [402.4(10)] SEMIRIGID COPPER TUBING |
387 | TABLE G2413.4(5) [402.4(13)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
388 | TABLE G2413.4(6) [402.4(16)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
389 | TABLE G2413.4(7) [402.4(19)] POLYETHYLENE PLASTIC PIPE |
390 | TABLE G2413.4(8) [402.4(20)] POLYETHYLENE PLASTIC PIPE |
391 | TABLE G2413.4(9) [402.4(23)] SCHEDULE 40 METALLIC PIPE |
392 | TABLE G2413.4(10) [402.4(24)] SCHEDULE 40 METALLIC PIPE |
393 | TABLE G2413.4 (11) [402.4(25)] SCHEDULE 40 METALLIC PIPE |
394 | TABLE G2413.4(12) [402.4(26)] SCHEDULE 40 METALLIC PIPE |
395 | TABLE G2413.4(13) [402.4(27)] SEMIRIGID COPPER TUBING |
396 | TABLE G2413.4(14) [402.4(28)] SEMIRIGID COPPER TUBING |
397 | TABLE G2413.4(15) [402.4(29)] SEMIRIGID COPPER TUBING |
398 | TABLE G2413.4(16) [402.4(30)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
399 | TABLE G2413.4(17) [402.4(31)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
400 | TABLE G2413.4(18) [402.4(32)] CORRUGATED STAINLESS STEEL TUBING (CSST) |
401 | TABLE G2413.4(19) [402.4(33)] POLYETHYLENE PLASTIC PIPE |
402 | TABLE G2413.4(20) [402.4(34)] POLYETHYLENE PLASTIC PIPE |
403 | TABLE G2413.4(21) [402.4(35)] POLYETHYLENE PLASTIC TUBING EQUATION 24-3 EQUATION 24-4 TABLE G2413.4 (402.4) Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS |
404 | SECTION G2414 (403) PIPING MATERIALS |
405 | TABLE G2414.9.2 (403.9.2) SPECIFICATIONS FOR THREADING METALLIC PIPE SECTION G2415 (404) PIPING SYSTEM INSTALLATION |
407 | SECTION G2416 (405) PIPING BENDS AND CHANGES IN DIRECTION |
408 | SECTION G2417 (406) INSPECTION, TESTING AND PURGING |
409 | SECTION G2418 (407) PIPING SUPPORT SECTION G2419 (408) DRIPS AND SLOPED PIPING TABLE G2420.1.1 MANUAL GAS VALVE STANDARDS |
410 | SECTION G2420 (409) GAS SHUTOFF VALVES SECTION G2421 (410) FLOW CONTROLS |
411 | SECTION G2422 (411) APPLIANCE CONNECTIONS SECTION G2423 (413) CNG GAS-DISPENSING SYSTEMS |
412 | SECTION G2424 (415) PIPING SUPPORT INTERVALS TABLE G2424.1 SUPPORT OF PIPING SECTION G2425 (501) GENERAL |
413 | SECTION G2426 (502) VENTS |
414 | SECTION G2427 (503) VENTING OF APPLIANCES TABLE G2427.4 TYPE OF VENTING SYSTEM TO BE USED |
415 | FIGURE G2427.5.3 (503.5.4) TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT APPLIANCES |
417 | FIGURE G2427.6.3 (503.6.4) GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL |
420 | TABLE G2427.10.5 (503.10.5)a CLEARANCES FOR CONNECTORS |
421 | TABLE G2427.10.2.4 (503.10.2.4) MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES |
423 | TABLE G2428.2(1) [504.2(1)] TYPE B DOUBLE-WALL GAS VENT |
424 | TABLE G2428.2(1) [504.2(1)]—continued TYPE B DOUBLE-WALL GAS VENT |
425 | TABLE G2428.2(2) [504.2(2)] TYPE B DOUBLE-WALL GAS VENT |
426 | TABLE G2428.2(2) [504.2(2)]—continued TYPE B DOUBLE-WALL GAS VENT |
427 | SECTION G2428 (504) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
428 | TABLE G2428.3(1) [504.3(1)] TYPE B DOUBLE-WALL VENT |
429 | TABLE G2428.3(2) [504.3(2)] TYPE B DOUBLE-WALL VENT |
430 | TABLE G2428.3(3) [504.3(3)] MASONRY CHIMNEY |
431 | TABLE G2428.3(4) [504.3(4)] MASONRY CHIMNEY |
432 | TABLE G2428.3.2 (504.3.2) MAXIMUM VENT CONNECTOR LENGTH |
435 | SECTION G2429 (505) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUSTHOOD VENTING SECTION G2430 (506) FACTORY-BUILT CHIMNEYS SECTION G2431 (601) GENERAL SECTION G2432 (602) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION G2433 (603) LOG LIGHTERS SECTION G2434 (604) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) SECTION G2435 (605) VENTED GAS FIREPLACE HEATERS SECTION G2436 (608) VENTED WALL FURNACES |
436 | SECTION G2437 (609) FLOOR FURNACES SECTION G2438 (613) CLOTHES DRYERS SECTION G2439 (614) CLOTHES DRYER EXHAUST TABLE G2439.5.5.1 (TABLE 614.6.5.1) DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
437 | SECTION G2440 (615) SAUNA HEATERS |
438 | SECTION G2441 (617) POOL AND SPA HEATERS SECTION G2442 (618) FORCED-AIR WARM-AIR FURNACES |
439 | SECTION G2443 (619) CONVERSION BURNERS SECTION G2444 (620) UNIT HEATERS SECTION G2445 (621) UNVENTED ROOM HEATERS SECTION G2446 (622) VENTED ROOM HEATERS |
440 | SECTION G2447 (623) COOKING APPLIANCES TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES |
441 | SECTION G2448 (624) WATER HEATERS SECTION G2449 (627) AIR CONDITIONING APPLIANCES SECTION G2450 (628) ILLUMINATING APPLIANCES SECTION G2451 (630) INFRARED RADIANT HEATERS SECTION G2452 (631) BOILERS SECTION G2453 (634) CHIMNEY DAMPER OPENING AREA |
442 | PART VII – PLUMBING CHAPTER 25 PLUMBING ADMINISTRATION SECTION P2501 GENERAL SECTION P2502 EXISTING PLUMBING SYSTEMS SECTION P2503 INSPECTION AND TESTS |
444 | CHAPTER 26 GENERAL PLUMBING REQUIREMENTS SECTION P2601 GENERAL SECTION P2602 INDIVIDUAL WATER SUPPLYAND SEWAGE DISPOSAL SECTION P2603 STRUCTURAL AND PIPING PROTECTION |
445 | SECTION P2604 TRENCHING AND BACKFILLING FIGURE P2604.4 PIPE LOCATION WITH RESPECT TO FOOTINGS SECTION P2605 SUPPORT |
446 | TABLE P2605.1 PIPING SUPPORT SECTION P2606 WATERPROOFING OF OPENINGS SECTION P2607 WORKMANSHIP SECTION P2608 MATERIALS EVALUATION AND LISTING |
447 | TABLE P2608.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION |
448 | CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION P2702 FIXTURE ACCESSORIES SECTION P2703 TAIL PIECES SECTION P2704 ACCESS TO CONNECTIONS SECTION P2705 INSTALLATION SECTION P2706 WASTE RECEPTORS |
449 | TABLE P2701.1 PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS |
450 | SECTION P2707 DIRECTIONAL FITTINGS SECTION P2708 SHOWERS SECTION P2709 SHOWER RECEPTORS |
451 | SECTION P2710 SHOWER WALLS SECTION P2711 LAVATORIES SECTION P2712 WATER CLOSETS |
452 | SECTION P2713 BATHTUBS SECTION P2714 SINKS SECTION P2715 LAUNDRY TUBS SECTION P2716 FOOD WASTE GRINDER SECTION P2717 DISHWASHING MACHINES SECTION P2718 CLOTHES WASHING MACHINE SECTION P2719 FLOOR DRAINS SECTION P2720 WHIRLPOOL BATHTUBS |
453 | SECTION P2721 BIDET INSTALLATIONS SECTION P2722 FIXTURE FITTING SECTION P2723 MACERATING TOILET SYSTEMS SECTION P2724 SPECIALTY TEMPERATURE CONTROL DEVICES AND VALVES |
454 | CHAPTER 28 WATER HEATERS SECTION P2801 GENERAL SECTION P2802 WATER HEATERS USED FOR SPACE HEATING SECTION P2803 RELIEF VALVES |
456 | CHAPTER 29 WATER SUPPLY AND DISTRIBUTION SECTION P2901 GENERAL SECTION P2902 PROTECTION OF POTABLE WATER SUPPLY |
457 | TABLE P2902.3 APPLICATION FOR BACKFLOW PREVENTERS |
458 | TABLE P2902.3.1 MINIMUM AIR GAPS |
459 | SECTION P2903 WATER-SUPPLY SYSTEM TABLE P2903.1 REQUIRED CAPACITIES AT POINT OF OUTLET DISCHARGE TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE P2903.2b MINIMUM WATER SERVICE SIZE |
460 | TABLE P2903.6 WATER-SUPPLY FIXTURE-UNIT VALUES FOR VARIOUS PLUMBING FIXTURES AND FIXTURE GROUPS |
461 | TABLE P2903.6(1) CONVERSIONS FROM WATER SUPPLY FIXTURE UNIT TO GALLON PER MINUTE FLOW RATES TABLE P2903.8.1 MANIFOLD SIZING |
462 | FIGURE P2903.10 TYPICAL FROSTPROOF HOSE BIBB INSTALLATION NOT REQUIRING SEPARATE VALUE SECTION P2904 DWELLING UNIT FIRE SPRINKLER SYSTEMS |
463 | TABLE P2904.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED |
465 | EQUATION 29-1 |
466 | TABLE P2904.6.2(1) WATER SERVICE PRESSURE LOSS |
467 | TABLE P2904.6.2(2) MINIMUM WATER METER PRESSURE LOSS TABLE P2904.6.2(3) ELEVATION LOSS |
468 | TABLE P2904.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING |
469 | TABLE P2904.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING |
470 | TABLE P2904.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE |
471 | TABLE P2904.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE |
472 | TABLE P2904.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX TUBING |
473 | TABLE P2904.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX TUBING |
474 | SECTION P2905 MATERIALS, JOINTS AND CONNECTIONS |
475 | TABLE P2905.4 WATER SERVICE PIPE |
476 | TABLE P2905.5 WATER DISTRIBUTION PIPE TABLE P2905.6 PIPE FITTINGS |
477 | SECTION P2906 CHANGES IN DIRECTION SECTION P2907 SUPPORT |
478 | SECTION P2908 DRINKING WATER TREATMENT UNITS |
480 | CHAPTER 30 SANITARY DRAINAGE SECTION P3001 GENERAL SECTION P3002 MATERIALS SECTION P3003 JOINTS AND CONNECTIONS |
481 | TABLE P3002.1(1) ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE P3002.1(2) UNDERGROUND BUILDING DRAINAGE AND VENT PIPE |
482 | TABLE P3002.2 BUILDING SEWER PIPE TABLE P3002.3 PIPE FITTINGS |
485 | SECTION P3004 DETERMINING DRAINAGE FIXTURE UNITS TABLE P3004.1 DRAINAGE FIXTURE UNIT (d.f.u.) VALUES FOR VARIOUS PLUMBING FIXTURES |
486 | SECTION P3005 DRAINAGE SYSTEM TABLE P3005.1 FITTINGS FOR CHANGE IN DIRECTION |
487 | TABLE P3005.4.1 MAXIMUM FIXTURE UNITS ALLOWED TO BE CONNECTED TO BRANCHES AND STACKS TABLE P3005.4.2 MAXIMUM NUMBER OF FIXTURE UNITS ALLOWED TO BE CONNECTED TO THE BUILDING DRAIN, BUILDING DRAIN BRANCHES OR THE BUILDING SEWER |
488 | SECTION P3006 SIZING OF DRAIN PIPE OFFSETS SECTION P3007 SUMPS AND EJECTORS |
489 | TABLE 3007.6 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION P3008 BACKWATER VALVES |
490 | CHAPTER 31 VENTS SECTION P3101 VENT SYSTEMS SECTION P3102 VENT STACKS AND STACK VENTS SECTION P3103 VENT TERMINALS SECTION P3104 VENT CONNECTIONS AND GRADES |
491 | SECTION P3105 FIXTURE VENTS TABLE P3105.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION P3106 INDIVIDUAL VENT SECTION P3107 COMMON VENT TABLE P3107.3 COMMON VENT SIZES SECTION P3108 WET VENTING |
492 | TABLE P3108.3 WET VENT SIZE SECTION P3109 WASTE STACK VENT TABLE P3109.4 WASTE STACK VENT SIZE SECTION P3110 CIRCUIT VENTING SECTION P3111 COMBINATION WASTE AND VENT SYSTEM |
493 | TABLE P3111.3 SIZE OF COMBINATION WASTE AND VENT PIPE SECTION P3112 ISLAND FIXTURE VENTING SECTION P3113 VENT PIPE SIZING SECTION P3114 AIR ADMITTANCE VALVES |
494 | TABLE P3113.4.1 SIZE AND LENGTH OF SUMP VENTS |
496 | CHAPTER 32 TRAPS SECTION P3201 FIXTURE TRAPS TABLE P3201.7 SIZE OF TRAPS AND TRAP ARMS FOR PLUMBING FIXTURES |
498 | CHAPTER 33 STORM DRAINAGE SECTION P3301 GENERAL SECTION P3302 SUBSOIL DRAINS TABLE P3302.1 SUBSOIL DRAIN PIPE SECTION P3303 SUMPS AND PUMPING SYSTEMS |
500 | PART VIII – ELECTRICAL CHAPTER 34 GENERAL REQUIREMENTS SECTION E3401 GENERAL SECTION E3402 BUILDING STRUCTURE PROTECTION SECTION E3403 CROSS REFERENCES TABLE E3403 CROSS REFERENCES DEFINING ELECTRICAL REQUIREMENTS OF THE FLORIDA BUILDING CODE |
501 | TABLE E3303—continued FLORIDA BUILDING CODE |
502 | TABLE E3403—continued FLORIDA BUILDING CODE |
503 | TABLE E3403—continued FLORIDA BUILDING CODE |
504 | SECTION E3404 GENERAL EQUIPMENT REQUIREMENTS RESERVED SECTION E3405 EQUIPMENT LOCATION AND CLEARANCES RESERVED SECTION E3406 ELECTRICAL CONDUCTORS AND CONNECTIONS RESERVED SECTIONS E3407 CONDUCTOR AND TERMINAL IDENTIFICATION RESERVED |
506 | CHAPTER 35 ELECTRICAL DEFINITIONS RESERVED |
508 | CHAPTER 36 SERVICES RESERVED |
510 | CHAPTER 37 BRANCH CIRCUIT AND FEEDER REQUIREMENTS RESERVED |
512 | CHAPTER 38 WIRING METHODS RESERVED |
514 | CHAPTER 39 POWER AND LIGHTING DISTRIBUTION RESERVED |
516 | CHAPTER 40 DEVICES AND LUMINAIRES RESERVED |
518 | CHAPTER 41 SWIMMING POOLS SECTION R4101 PRIVATE SWIMMING POOLS |
526 | CHAPTER 42 SWIMMING POOLS RESERVED (See Chapter 41) |
528 | PART IX – REFERENCED STANDARDS CHAPTER 43 REFERENCED STANDARDS AA AAF AAMA |
529 | ACCA ACI ADC |
530 | AFPA AHA AISC AISI |
531 | AITC ANSI |
532 | APA |
533 | APSP ASCE/SEI ASHRAE ASME |
535 | ASSE ASTM |
545 | AWPA AWS AWWA CGSB |
546 | CISPI CPA CPSC CSA |
547 | CSSB DASMA |
548 | DHS/FEMA DOC/NIST DOL/OSHA DOT FLORIDA CODES |
550 | FM FRSA FS GA HPVA |
551 | ICC ISO MAF MSS NAAMM NAIMA |
552 | NCMA NFPA NRCA NSF |
553 | PCA RMI/SMA RCSC SDI |
554 | SDI SJI SMACNA SPRI SSPC STI |
555 | TECO TMS TPI UL |
556 | ULC WDMA |
557 | WPPC WQA |
558 | CHAPTER 44 HIGH-VELOCITY HURRICANE ZONES SECTION R4401 HIGH-VELOCITY HURRICANE ZONES —EXTERIOR WALL COVERING SECTION R4402 HIGH-VELOCITY HURRICANE ZONES — ROOF ASSEMBLIES AND ROOFTOP STRUCTURES |
559 | SECTION R4402.2 HIGH-VELOCITY HURRICANE ZONES —DEFINITIONS |
561 | SECTION R4402.3 HIGH-VELOCITY HURRICANE ZONES —WEATHER PROTECTION |
562 | SECTION R4402.4 HIGH-VELOCITY HURRICANE ZONES —PERFORMANCE REQUIREMENTS |
563 | TABLE R4402.4.2 MINIMUM SLOPE SECTION R4402.5 HIGH-VELOCITY HURRICANE ZONES —FIRE CLASSIFICATION |
564 | SECTION R4402.6 HIGH-VELOCITY HURRICANE ZONES —MATERIALS SECTION R4402.7 HIGH-VELOCITY HURRICANE ZONES —ROOF COVERINGS WITH SLOPES 2:12 OR GREATER |
567 | SECTION R4402.8 HIGH-VELOCITY HURRICANE ZONES — ROOF COVERINGS WITH SLOPES LESS THAN 2:12 TABLE R4402.8.3A SLOPE AND APPLICATION TEMPERATURE CRITERIA TABLE R4402.8.3B SLOPE AND APPLICATION TEMPERATURE CRITERIA |
569 | SECTION R4402.9 HIGH-VELOCITY HURRICANE ZONES —ROOF INSULATION |
570 | SECTION R4402.10 HIGH-VELOCITY HURRICANE ZONES —REROOFING |
571 | SECTION R4402.11 HIGH-VELOCITY HURRICANE ZONES — ROOFTOP STRUCTURES AND COMPONENTS |
572 | TABLE R4402.11.3 ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS SECTION R4402.12 HIGH-VELOCITY HURRICANE ZONES — TESTING |
575 | SECTION R4402.13 HIGH-VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS |
577 | SECTION R4402.14 HIGH-VELOCITY HURRICANE ZONES-UNIFORM PERMIT APPLICATION |
582 | SECTION R4403 HIGH-VELOCITY HURRICANE ZONES—GENERAL SECTION R4403.2 HIGH-VELOCITY HURRICANE ZONES—DEFLECTION SECTION R4403.3 HIGH-VELOCITY HURRICANE ZONES—VOLUME CHANGES SECTION R4403.4 HIGH-VELOCITY HURRICANE ZONES—MINIMUM LOADS |
583 | SECTION R4403.5 HIGH-VELOCITY HURRICANE ZONES —ROOF LIVE LOADS SECTION R4403.6 HIGH-VELOCITY HURRICANE ZONES —ROOF DRAINAGE FIGURE R4403.6.3 REQUIRED AREA OF OVERFLOW SCUPPERS SECTION R4403.7 HIGH-VELOCITY HURRICANE ZONES —SPECIAL LOAD CONSIDERATIONS |
585 | SECTION R4403.8 HIGH-VELOCITY HURRICANE ZONES — LIVE LOAD REDUCTIONS SECTION R4403.9 HIGH-VELOCITY HURRICANE ZONES —WIND LOADS SECTION R4403.10 HIGH VELOCITY HURRICANE ZONES —OVERTURNING MOMENT AND UPLIFT |
586 | SECTION R4403.11 HIGH VELOCITY HURRICANE ZONES —SUNROOMS SECTION R4403.12 HIGH-VELOCITY HURRICANE ZONES — SCREEN ENCLOSURES SECTION R4403.13 HIGH VELOCITY HURRICANE ZONES—FLOOD RESISTANCE SECTION R4403.14 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION DESIGN |
587 | SECTION R4403.15 HIGH-VELOCITY HURRICANE ZONES—LOAD TESTS TABLE R4403.15.4 FATIGUE LOADING SEQUENCE SECTION R4403.16 HIGH-VELOCITY HURRICANE ZONES—IMPACT TESTS FOR WIND-BORNE DEBRIS |
589 | TABLE R4403.16 CYCLIC WIND PRESSURE LOADING |
590 | SECTION R4404 HIGH-VELOCITY HURRICANE ZONES—FOUNDATIONS AND RETAINING WALLS SECTION R4404.2 HIGH-VELOCITY HURRICANE ZONES—BEARING CAPACITY OF SOIL SECTION R4404.3 HIGH-VELOCITY HURRICANE ZONES—SOIL BEARING FOUNDATIONS |
592 | TABLE R4404.3.6 ALLOWABLE LATERAL PRESSURE SECTION R4404.4 HIGH-VELOCITY HURRICANE ZONES —CONCRETE SLABS ON FILL |
593 | SECTION R4404.5 HIGH-VELOCITY HURRICANE ZONES —MONOLITHIC FOOTINGS |
594 | SECTION R4404.6 HIGH-VELOCITY HURRICANE ZONES—PILE FOUNDATIONS |
595 | TABLE R4404.7 |
596 | SECTION R4404.7 HIGH-VELOCITY HURRICANE ZONES —WOOD PILES SECTION R4404.8 HIGH-VELOCITY HURRICANE ZONES —PRECAST CONCRETE PILES TABLE R4404.8 |
597 | SECTION R4404.9 HIGH-VELOCITY HURRICANE ZONES—PRESTRESSED PRECAST CONCRETE PILES SECTION R4404.10 HIGH-VELOCITY HURRICANE ZONES—CAST-IN-PLACE SECTION R4404.11 HIGH-VELOCITY HURRICANE ZONES—ROLLED STRUCTURAL SHAPES |
598 | SECTION R4404.12 HIGH-VELOCITY HURRICANE ZONES—SPECIAL PILES OR SPECIAL CONDITIONS SECTION R4404.13 HIGH-VELOCITY HURRICANE ZONES—LOAD TESTS ON PILES SECTION R4404.14 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION WALLS AND GRADE BEAMS SECTION R4404.15 HIGH-VELOCITY HURRICANE ZONES—GRADES UNDER BUILDINGS |
599 | SECTION R4404.16 HIGH-VELOCITY HURRICANE ZONES—RETAINING WALLS SECTION R4404.17 HIGH-VELOCITY HURRICANE ZONES—SEAWALLS AND BULKHEADS SECTION R4404.18 HIGH-VELOCITY HURRICANE ZONES —SOIL IMPROVEMENT |
600 | SECTION R4405 HIGH-VELOCITY HURRICANE ZONES—CONCRETE SECTION R4405.2 HIGH-VELOCITY HURRICANE ZONES—STANDARDS SECTION R4405.3 HIGH-VELOCITY HURRICANE ZONES—DEFINITIONS SECTION R4405.4 HIGH-VELOCITY HURRICANE ZONES—MATERIALS |
602 | SECTION R4405.5 HIGH VELOCITY HURRICANE ZONES—CONCRETE QUALITY |
603 | SECTION R4405.6 HIGH-VELOCITY HURRICANE ZONES—MIXING AND PLACING CONCRETE |
604 | SECTION R4405.7 HIGH-VELOCITY HURRICANE ZONES—FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS |
605 | SECTION R4405.8 HIGH-VELOCITY HURRICANE ZONES—DETAILS OF REINFORCEMENT |
607 | SECTION R4405.9 HIGH-VELOCITY HURRICANE ZONES—PRECAST CONCRETE UNITS |
608 | SECTION R4405.10 HIGH-VELOCITY HURRICANE ZONES—PRESTRESSED CONCRETE |
610 | SECTION R4405.11 HIGH-VELOCITY HURRICANE ZONES—PNEUMATICALLY PLACED CONCRETE (SHOTCRETE) |
611 | SECTION R4405.12 HIGH-VELOCITY HURRICANE ZONES—LIGHTWEIGHT INSULATING CONCRETE FILL |
612 | SECTION 4406 HIGH-VELOCITY HURRICANE ZONES—LIGHT METAL ALLOYS |
614 | SECTION 4407 HIGH-VELOCITY HURRICANE ZONES—MASONRY SECTION R4407.2 HIGH-VELOCITY HURRICANE ZONES—QUALITY, TESTS, AND APPROVALS |
616 | SECTION R4407.3 HIGH-VELOCITY HURRICANE ZONES—ALLOWABLE UNIT STRESSES IN UNIT MASONRY SECTION R4407.4 HIGH-VELOCITY HURRICANE ZONES—CONSTRUCTION DETAILS |
621 | SECTION R4407.5 HIGH-VELOCITY HURRICANE ZONES—REINFORCED UNIT MASONRY |
622 | SECTION R4408 HIGH-VELOCITY HURRICANE ZONES—STEEL |
624 | SECTION R4408.2 HIGH-VELOCITY HURRICANE ZONES—MATERIAL SECTION R4408.3 HIGH-VELOCITY HURRICANE ZONES—DESIGN LOADS SECTION R4408.4 HIGH-VELOCITY HURRICANE ZONES—MINIMUM THICKNESS OF MATERIAL SECTION R4408.5 HIGH-VELOCITY HURRICANE ZONES—CONNECTIONS SECTION R4408.6 HIGH-VELOCITY HURRICANE ZONES—TUBULAR COLUMNS SECTION R4408.7 HIGH-VELOCITY HURRICANE ZONES—PROTECTION OF METAL |
625 | SECTION R4408.8 HIGH-VELOCITY HURRICANE ZONES—OPEN WEB STEEL JOISTS |
626 | SECTION R4408.9 HIGH VELOCITY HURRICANE ZONES—COLD-FORMED STEEL CONSTRUCTION |
627 | SECTION R4408.10 HIGH-VELOCITY HURRICANE ZONES—PREENGINEERED, PREFABRICATED METAL BUILDING SYSTEMS AND COMPONENTS(PREENGINEERED STRUCTURES) |
628 | TABLE R4408.11 CHAIN LINK FENCE MINIMUM REQUIREMENTS |
629 | SECTION R4408.11 HIGH-VELOCITY HURRICANE ZONES—CHAIN LINK FENCES SECTION R4409 HIGH-VELOCITY HURRICANE ZONES—WOOD |
631 | SECTION R4409.2 HIGH-VELOCITY HURRICANE ZONES—QUALITY |
632 | TABLE R4409.2.4.2 MINIMUM GRADE REQUIREMENTS: BOARD GRADES SECTION R4409.3 RESERVED SECTION R4409.4 HIGH-VELOCITY HURRICANE ZONES—UNIT STRESSES SECTION R4409.5 HIGH-VELOCITY HURRICANE ZONES—VERTICAL FRAMING |
634 | SECTION R4409.6 HIGH-VELOCITY HURRICANE ZONES—HORIZONTAL FRAMING |
639 | SECTION R4409.7 HIGH-VELOCITY HURRICANE ZONES —FIRESTOPS |
640 | SECTION R4409.8 HIGH-VELOCITY HURRICANE ZONES—ANCHORAGE SECTION R4409.9 HIGH-VELOCITY HURRICANE ZONES—SHEATHING |
641 | TABLE R4409.9.1.6 PLYWOOD SUBFLOOR1 TABLE R4409.9.1.13 ALLOWABLE SPAN FOR PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENT1 (SINGLE FLOOR PANELS) |
642 | TABLE R4409.9.2.3 ALLOWABLE SPAN FOR PLYWOOD ROOF SHEATHING1 |
643 | SECTION R4409.10 HIGH-VELOCITY HURRICANE ZONES—FURRING SECTION R4409.11 HIGH-VELOCITY HURRICANE ZONES—CONNECTORS SECTION R4409.12 HIGH-VELOCITY HURRICANE ZONES—WOOD SUPPORTING MASONRY |
644 | SECTION R4409.13 HIGH-VELOCITY HURRICANE ZONES—PROTECTION OF WOOD TABLE R4409.13.1 NAIL CONNECTION FOR WOOD MEMBERS |
646 | SECTION R4409.14 HIGH-VELOCITY HURRICANE ZONES—FIRE-RETARDANT WOOD SECTION R4409.15 HIGH-VELOCITY HURRICANE ZONES—WOOD FENCES |
647 | SECTION R4409.16 HIGH-VELOCITY HURRICANE ZONES—FIRE-RETARDANT-TREATED SHAKES ANDSHINGLES SECTION R4409.17 HIGH-VELOCITY HURRICANE ZONES—WOOD BLOCKING SECTION R4410 HIGH-VELOCITY HURRICANE ZONES—GLASS AND GLAZING |
648 | SECTION R4410.2 HIGH-VELOCITY HURRICANE ZONES—WINDOWS, DOORS, GLASS AND GLAZING |
652 | SECTION R4410.3 HIGH-VELOCITY HURRICANE ZONES—GLASS VENEER SECTION R4410.4 HIGH-VELOCITY HURRICANE ZONES—STORM SHUTTERS/EXTERNAL PROTECTIVE DEVICES |
653 | SECTION R4410.5 HIGH-VELOCITY HURRICANE ZONES—CURTAIN WALLS SECTION R4410.6 HIGH-VELOCITY HURRICANE ZONES—STRUCTURAL GLAZING SYSTEMS |
654 | SECTION R4411 HIGH-VELOCITY HURRICANE ZONES —GYPSUM BOARD AND PLASTER |
655 | TABLE R4411.1.3.2 WEIGHTS OF METAL AND WIRE LATH |
656 | TABLE R4411.1.5.2 SPANS AND SPACING OF MAIN RUNNERS TABLE R4411.1.5.3 SIZES OF CROSS FURRING IN SUSPENDED AND FURRED CEILINGS TABLE R4411.1.5.4 HANGERS SUPPORTING SUSPENDED CEILINGS SECTION R4411.2 HIGH VELOCITY HURRICANE ZONES–PLASTER TABLE R4411.2.1.5 REQUIRED THICKNESS OF INTERIOR PLASTER |
657 | TABLE R4411.2.3.1.1 GYPSUM AND HARDWALL PLASTER |
658 | SECTION R4411.3 HIGH-VELOCITY HURRICANE ZONES — STUCCO |
659 | SECTION R4411.4 HIGH-VELOCITY HURRICANE ZONES—GYPSUM BOARD PRODUCTS AND ACCESSORY ITEMS |
660 | SECTION R4411.5 HIGH-VELOCITY HURRICANE ZONES—SUSPENDED AND FURRED CEILINGS SECTION R4411.6 HIGH-VELOCITY HURRICANE ZONES—ASBESTOS SECTION R4411.7 HIGH-VELOCITY HURRICANE ZONES—TILE |
661 | SECTION R4412 HIGH-VELOCITY HURRICANE ZONES—PLASTICS |
663 | TABLE R4412.1.4.3.1.3 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR PLASTIC WALL PANELS IN NONFIRE-RATED WALLS |
664 | TABLE R4412.1.4.4.4 AREA LIMITATIONS FOR ROOF PANELS |
665 | SECTION R4413 HIGH-VELOCITY HURRICANE ZONES—STORM DRAINAGE |
666 | TABLE R4413.1.6 FITTINGS FOR CHANGE IN DIRECTION SECTION R4413.2 HIGH VELOCITY HURRICANE ZONES—MATERIALS TABLE R4413.2.2 ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE R4413.2.3 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE |
667 | TABLE R4413.2.4 BUILDING STORM SEWER PIPE TABLE R4413.2.5 SUBSOIL DRAIN PIPE TABLE R4413.2.7 PIPE FITTINGS SECTION R4413.3 RESERVED SECTION R4413.4 HIGH-VELOCITY HURRICANE ZONES—CONDUCTORS AND CONNECTIONS SECTION R4413.5 HIGH-VELOCITY HURRICANE ZONES—ROOF DRAINS |
668 | SECTION R4413.6 HIGH VELOCITY HURRICANE ZONES—SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS SECTION R4413.7 HIGH-VELOCITY HURRICANE ZONES—SECONDARY (EMERGENCY) ROOF DRAINS |
669 | FIGURE R4413.6.1 100-YEAR, 1-HOUR RAINFALL (inches)EASTERN UNITED STATES |
670 | TABLE R4413.6.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS TABLE R4413.6.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING |
671 | TABLE R4416.6.6 SIZE OF SEMICIRCULAR ROOF GUTTERS TABLE R4413.7 SIZING SCUPPERS FOR A 5 INCHES PER HOUR RATE OF RAINFALL |
672 | APPENDIX A SIZING AND CAPACITIES OF GAS PIPING A.1 GENERAL PIPING CONSIDERATIONS A.2 DESCRIPTION OF TABLES |
673 | TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
674 | TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
675 | TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES G2413.4(1) THROUGH G2413.4(8) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 A.3 USE OF CAPACITY TABLES |
677 | TABLE A.3.4 THOUSANDS OF Btu/h (MBH) OF NATURAL GAS PER 100 FEET OF PIPE ATVARIOUS PRESSURE DROPS AND PIPE DIAMETERS A.4 USE OF SIZING EQUATIONS A.5 PIPE AND TUBE DIAMETERS |
678 | TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES TABLE A.5.2 COPPER TUBE STANDARD SIZES A.6 USE OF SIZING CHARTS |
679 | FIGURE A.6(a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) FIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above) |
680 | A.7 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING FIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM |
681 | FIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM |
682 | FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM |
684 | APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS EXAMPLES USING SINGLE APPLIANCE VENTING TABLES FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVINGA SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR |
685 | FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALLMETAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCESWITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
686 | FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES |
687 | FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B-12 USE OF OFFSET COMMON VENT FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM FIGURE B-14 MULTISTORY VENT SYSTEMS |
688 | FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE |
689 | EXAMPLES USING COMMON VENTING TABLES FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
691 | TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa |
692 | FIGURE B-19 |
694 | APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFTAND DIRECT-VENT VENTING SYSTEMS FIGURE C-1 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS |
696 | APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION RESERVED |
698 | APPENDIX E CHAPTER 9B-53 FLORIDA STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS |
699 | INTRODUCTION PRINCIPAL APPROACHES FOR RADON MITIGATION IN EXISTING BUILDINGS FOREWORD |
700 | CHAPTER E1 ADMINISTRATION CHAPTER E2 DEFINITIONS |
701 | CHAPTER E3 TESTING CHAPTER E4 STRUCTURAL SEALING AND HVAC SYSTEM BALANCING |
702 | CHAPTER E5 ENGINEERED SYSTEMS |
703 | CHAPTER E6 SOIL DEPRESSURIZATION SYSTEMS |
706 | APPENDIX F CHAPTER 9B-52 FLORIDA STANDARD FOR PASSIVE RADON-RESISTANT NEW RESIDENTIAL BUILDING CONSTRUCTION |
707 | CHAPTER F1 GENERAL CHAPTER F2 DEFINITIONS |
708 | CHAPTER F3 CONSTRUCTION REQUIREMENTS FOR PASSIVE RADON CONTROL |
714 | APPENDIX G SWIMMING POOLS, SPAS AND HOT TUBSRESERVED |
716 | APPENDIX H PATIO COVERS RESERVED |
718 | APPENDIX I PRIVATE SEWAGE DISPOSAL RESERVED |
720 | APPENDIX J EXISTING BUILDINGS AND STRUCTURES RESERVED |
722 | APPENDIX K SOUND TRANSMISSIONRESERVED |
724 | APPENDIX L PERMIT FEES RESERVED |
726 | APPENDIX M HOME DAY CARE—R-3 OCCUPANCY RESERVED |
728 | APPENDIX N VENTING METHODS RESERVED |
730 | APPENDIX O GRAY WATER RECYCLING SYSTEMS SECTION AO101 GENERAL |
731 | FIGURE AO101.1(1) GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION SECTION AO102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS SECTION AO103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS RESERVED |
732 | APPENDIX P SIZING OF WATER PIPING SYSTEM RESERVED |
734 | APPENDIX Q ICC INTERNATIONAL RESIDENTIAL CODE ELECTRICAL PROVISIONS/NATIONAL ELECTRICAL CODE CROSS-REFERENCERESERVED |
736 | INDEX |
748 | FLORIDA BUILDING CODE 2010 BUILDING CHAPTER 1 |
750 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
752 | PART 2— ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
753 | SECTION 105 PERMITS |
756 | SECTION 106 FLOOR AND ROOF DESIGN LOADS SECTION 107 SUBMITTAL DOCUMENTS |
760 | SECTION 108 TEMPORARY STRUCTURES AND USES SECTION 109 FEES SECTION 110 INSPECTIONS |
763 | SECTION 111 CERTIFICATE OF OCCUPANCY |
764 | SECTION 112 SERVICE UTILITIES SECTION 113 BOARD OF APPEALS RESERVED SECTION 114 VIOLATIONS RESERVED SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT RESERVED |
766 | HELPFUL CODE TOOLS FROM ICC |