IPC 09 2009
$45.77
International Plumbing Code
Published By | Publication Date | Number of Pages |
ICC | 2009 | 264 |
Provides comprehensive minimum regulations for plumbing facilities in terms of both performance and prescriptive objectives, and provides for the acceptance of new and innovative products, materials and systems.
Included is the 2009 International Private Sewage Disposal Code. This companion to the IPC includes provisions for design, installation, and inspection of private sewage disposal systems, and provides flexibility in the development of safe and sanitary systems.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2009 IPC® INTERNATIONAL PLUMBING CODE® 2009 IPC® INTERNATIONAL PLUMBING CODE® |
2 | INTERNATIONAL PLUMBING CODE® INTERNATIONAL PLUMBING CODE® |
3 | COPYRIGHT COPYRIGHT |
4 | PREFACE PREFACE |
6 | EFFECTIVE USE OF THE INTERNATIONAL PLUMBING CODE EFFECTIVE USE OF THE INTERNATIONAL PLUMBING CODE |
10 | ORDINANCE ORDINANCE |
12 | TABLE OF CONTENTS TABLE OF CONTENTS |
16 | CHAPTER 1 SCOPE AND ADMINISTRATION CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 101 GENERAL SECTION 102 APPLICABILITY SECTION 102 APPLICABILITY |
17 | PART 2—ADMINISTRATION AND ENFORCEMENT PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 APPROVAL SECTION 105 APPROVAL |
18 | SECTION 106 PERMITS SECTION 106 PERMITS |
20 | SECTION 107 INSPECTIONS AND TESTING SECTION 107 INSPECTIONS AND TESTING |
21 | SECTION 108 VIOLATIONS SECTION 108 VIOLATIONS |
22 | SECTION 109 MEANS OF APPEAL SECTION 109 MEANS OF APPEAL |
23 | SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
24 | CHAPTER 2 DEFINITIONS CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS SECTION 202 GENERAL DEFINITIONS |
32 | CHAPTER 3 GENERAL REGULATIONS CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS SECTION 303 MATERIALS SECTION 304 RODENTPROOFING SECTION 304 RODENTPROOFING SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
33 | TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION SECTION 306 TRENCHING, EXCAVATION AND BACKFILL SECTION 306 TRENCHING, EXCAVATION AND BACKFILL |
34 | SECTION 307 STRUCTURAL SAFETY SECTION 307 STRUCTURAL SAFETY SECTION 308 PIPING SUPPORT SECTION 308 PIPING SUPPORT |
35 | TABLE 308.5 HANGER SPACING TABLE 308.5 HANGER SPACING SECTION 309 FLOOD HAZARD RESISTANCE SECTION 309 FLOOD HAZARD RESISTANCE SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS |
36 | SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS SECTION 312 TESTS AND INSPECTIONS |
37 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL SECTION 314 CONDENSATE DISPOSAL TABLE [M] 314.2.2 CONDENSATE DRAIN SIZING TABLE [M] 314.2.2 CONDENSATE DRAIN SIZING |
40 | CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
41 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
42 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
43 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 405 INSTALLATION OF FIXTURES SECTION 405 INSTALLATION OF FIXTURES |
44 | FIGURE 405.3.1 FIXTURE CLEARANCE FIGURE 405.3.1 FIXTURE CLEARANCE SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 406 AUTOMATIC CLOTHES WASHERS |
45 | SECTION 407 BATHTUBS SECTION 407 BATHTUBS SECTION 408 BIDETS SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS SECTION 410 DRINKING FOUNTAINS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FLOOR AND TRENCH DRAINS SECTION 412 FLOOR AND TRENCH DRAINS SECTION 413 FOOD WASTE GRINDER UNITS SECTION 413 FOOD WASTE GRINDER UNITS SECTION 414 GARBAGE CAN WASHERS SECTION 414 GARBAGE CAN WASHERS |
46 | SECTION 415 LAUNDRY TRAYS SECTION 415 LAUNDRY TRAYS SECTION 416 LAVATORIES SECTION 416 LAVATORIES SECTION 417 SHOWERS SECTION 417 SHOWERS |
47 | SECTION 418 SINKS SECTION 418 SINKS SECTION 419 URINALS SECTION 419 URINALS SECTION 420 WATER CLOSETS SECTION 420 WATER CLOSETS |
48 | SECTION 421 WHIRLPOOL BATHTUBS SECTION 421 WHIRLPOOL BATHTUBS SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT |
49 | SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
50 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 427 FLOOR SINKS SECTION 427 FLOOR SINKS |
52 | CHAPTER 5 WATER HEATERS CHAPTER 5 WATER HEATERS SECTION 501 GENERAL SECTION 501 GENERAL SECTION 502 INSTALLATION SECTION 502 INSTALLATION SECTION 503 CONNECTIONS SECTION 503 CONNECTIONS |
53 | SECTION 504 SAFETY DEVICES SECTION 504 SAFETY DEVICES SECTION 505 INSULATION SECTION 505 INSULATION |
54 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 601 GENERAL SECTION 602 WATER REQUIRED SECTION 602 WATER REQUIRED SECTION 603 WATER SERVICE SECTION 603 WATER SERVICE |
55 | SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS |
56 | TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES TABLE 604.10.1 MANIFOLD SIZING TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
57 | TABLE 605.3 WATER SERVICE PIPE TABLE 605.3 WATER SERVICE PIPE |
58 | TABLE 605.4 WATER DISTRIBUTION PIPE TABLE 605.4 WATER DISTRIBUTION PIPE TABLE 605.5 PIPE FITTINGS TABLE 605.5 PIPE FITTINGS |
59 | TABLE 605.8 MANUFACTURED PIPE NIPPLES TABLE 605.8 MANUFACTURED PIPE NIPPLES |
61 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM |
62 | TABLE 606.5.4 SIZES FOR OVER FLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.4 SIZES FOR OVER FLOW PIPES FOR WATER SUPPLY TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS SECTION 607 HOT WATER SUPPLY SYSTEM SECTION 607 HOT WATER SUPPLY SYSTEM |
63 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
64 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
65 | TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION |
66 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
67 | TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES |
68 | SECTION 609 HEALTH CARE PLUMBING SECTION 609 HEALTH CARE PLUMBING SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM |
69 | SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 612 SOLAR SYSTEMS SECTION 612 SOLAR SYSTEMS SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES |
70 | CHAPTER 7 SANITARY DRAINAGE CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL SECTION 701 GENERAL SECTION 702 MATERIALS SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
71 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.3 BUILDING SEWER PIPE TABLE 702.3 BUILDING SEWER PIPE |
72 | TABLE 702.4 PIPE FITTINGS TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER SECTION 703 BUILDING SEWER SECTION 704 DRAINAGE PIPING INSTALLATION SECTION 704 DRAINAGE PIPING INSTALLATION TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SECTION 705 JOINTS SECTION 705 JOINTS |
75 | TABLE 705.21 CAULKING FERRULE SPECIFICATIONS TABLE 705.21 CAULKING FERRULE SPECIFICATIONS TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
76 | TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS SECTION 708 CLEANOUTS |
77 | SECTION 709 FIXTURE UNITS SECTION 709 FIXTURE UNITS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING SECTION 710 DRAINAGE SYSTEM SIZING SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE |
78 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
79 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa |
80 | SECTION 712 SUMPS AND EJECTORS SECTION 712 SUMPS AND EJECTORS TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR |
81 | SECTION 713 HEALTH CARE PLUMBING SECTION 713 HEALTH CARE PLUMBING |
82 | TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS SECTION 714 COMPUTERIZED DRAINAGE DESIGN SECTION 714 COMPUTERIZED DRAINAGE DESIGN SECTION 715 BACKWATER VALVES SECTION 715 BACKWATER VALVES |
84 | CHAPTER 8 INDIRECT/SPECIAL WASTE CHAPTER 8 INDIRECT/SPECIAL WASTE SECTION 801 GENERAL SECTION 801 GENERAL SECTION 802 INDIRECT WASTES SECTION 802 INDIRECT WASTES |
85 | SECTION 803 SPECIAL WASTES SECTION 803 SPECIAL WASTES SECTION 804 MATERIALS, JOINTS AND CONNECTIONS SECTION 804 MATERIALS, JOINTS AND CONNECTIONS |
86 | CHAPTER 9 VENTS CHAPTER 9 VENTS SECTION 901 GENERAL SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 902 MATERIALS SECTION 903 OUTDOOR VENT EXTENSION SECTION 903 OUTDOOR VENT EXTENSION SECTION 904 VENT TERMINALS SECTION 904 VENT TERMINALS |
87 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 FIXTURE VENTS SECTION 906 FIXTURE VENTS TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 907 INDIVIDUAL VENT SECTION 907 INDIVIDUAL VENT SECTION 908 COMMON VENT SECTION 908 COMMON VENT TABLE 908.3 COMMON VENT SIZES TABLE 908.3 COMMON VENT SIZES |
88 | SECTION 909 WET VENTING SECTION 909 WET VENTING TABLE 909.3 WET VENT SIZE TABLE 909.3 WET VENT SIZE SECTION 910 WASTE STACK VENT SECTION 910 WASTE STACK VENT TABLE 910.4 WASTE STACK VENT SIZE TABLE 910.4 WASTE STACK VENT SIZE SECTION 911 CIRCUIT VENTING SECTION 911 CIRCUIT VENTING |
89 | SECTION 912 COMBINATION DRAIN AND VENT SYSTEM SECTION 912 COMBINATION DRAIN AND VENT SYSTEM TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE SECTION 913 ISLAND FIXTURE VENTING SECTION 913 ISLAND FIXTURE VENTING |
90 | SECTION 914 RELIEF VENTS—STACKS OF MORE THAN10 BRANCH INTERVALS SECTION 914 RELIEF VENTS—STACKS OF MORE THAN10 BRANCH INTERVALS SECTION 915 VENTS FOR STACK OFFSETS SECTION 915 VENTS FOR STACK OFFSETS SECTION 916 VENT PIPE SIZING SECTION 916 VENT PIPE SIZING TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
91 | TABLE 916.1—continued SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS TABLE 916.1—continued SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS SECTION 917 AIR ADMITTANCE VALVES SECTION 917 AIR ADMITTANCE VALVES |
92 | TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS SECTION 918 ENGINEERED VENT SYSTEMS SECTION 918 ENGINEERED VENT SYSTEMS |
93 | EQUATION 9-1 EQUATION 9-1 TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES SECTION 919 COMPUTERIZED VENT DESIGN SECTION 919 COMPUTERIZED VENT DESIGN |
94 | CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS SECTION 1002 TRAP REQUIREMENTS SECTION 1003 INTERCEPTORS AND SEPARATORS SECTION 1003 INTERCEPTORS AND SEPARATORS |
95 | TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa |
96 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
98 | CHAPTER 11 STORM DRAINAGE CHAPTER 11 STORM DRAINAGE SECTION 1101 GENERAL SECTION 1101 GENERAL SECTION 1102 MATERIALS SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE |
99 | TABLE 1102.7 PIPE FITTINGS TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS SECTION 1103 TRAPS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERSAND STORM DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERSAND STORM DRAINS |
100 | FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
101 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES |
102 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES |
103 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA |
104 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII |
105 | TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS |
106 | TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINGE PIPING TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINGE PIPING SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS |
107 | TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS SECTION 1108 COMBINED SANITARY AND STORM SYSTEM SECTION 1108 COMBINED SANITARY AND STORM SYSTEM SECTION 1109 VALUES FOR CONTINUOUS FLOW SECTION 1109 VALUES FOR CONTINUOUS FLOW |
108 | SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1111 SUBSOIL DRAINS SECTION 1111 SUBSOIL DRAINS SECTION 1112 BUILDING SUBDRAINS SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
110 | CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS SECTION 1201 GENERAL SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1202 MEDICAL GASES SECTION 1203 OXYGEN SYSTEMS SECTION 1203 OXYGEN SYSTEMS |
112 | CHAPTER 13 REFERENCED STANDARDS CHAPTER 13 REFERENCED STANDARDS ANSI ANSI AHRI AHRI ASME ASME |
113 | ASSE ASSE |
115 | ASTM ASTM |
117 | AWS AWS AWWA AWWA |
118 | CISPI CISPI CSA CSA |
119 | ICC ICC ISEA ISEA NFPA NFPA |
120 | NSF NSF PDI PDI UL UL |
122 | APPENDIX A PLUMBING PERMIT FEE SCHEDULE APPENDIX A PLUMBING PERMIT FEE SCHEDULE |
124 | APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES |
126 | APPENDIX C GRAY WATER RECYCLING SYSTEMS APPENDIX C GRAY WATER RECYCLING SYSTEMS SECTION C101 GENERAL SECTION C101 GENERAL SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS |
127 | SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS |
128 | TABLE C103.8 LOCATION OF GRAY WATER SYSTEM TABLE C103.8 LOCATION OF GRAY WATER SYSTEM TABLE C 103.9.1 DESIGN LOADING RATE TABLE C 103.9.1 DESIGN LOADING RATE |
129 | TABLE C103.10 DISTRIBUTION PIPE TABLE C103.10 DISTRIBUTION PIPE |
130 | FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION |
131 | FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS |
132 | APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
133 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
134 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
135 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
136 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
138 | APPENDIX E SIZING OF WATER PIPING SYSTEM APPENDIX E SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED SECTION E102 INFORMATION REQUIRED SECTION E103 SELECTION OF PIPE SIZE SECTION E103 SELECTION OF PIPE SIZE |
142 | TABLE E.1 TABLE E.1 TABLE E.2 TABLE E.2 |
143 | FIGURE E103.3(1) EXAMPLE-SIZING FIGURE E103.3(1) EXAMPLE-SIZING |
144 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
145 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa |
146 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
147 | TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) |
148 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet) |
149 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING) FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING) |
150 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING) FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING) |
151 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING) FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING) |
152 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa |
153 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa |
154 | FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa |
155 | SECTION E201 SELECTION OF PIPE SIZE SECTION E201 SELECTION OF PIPE SIZE SECTION E202 DETERMINATION OF PIPE VOLUMES SECTION E202 DETERMINATION OF PIPE VOLUMES |
156 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
157 | TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
158 | TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
160 | APPENDIX F STRUCTURAL SAFETY APPENDIX F STRUCTURAL SAFETY SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS |
162 | APPENDIX G VACUUM DRAINAGE SYSTEM APPENDIX G VACUUM DRAINAGE SYSTEM SECTION G101 VACUUM DRAINAGE SYSTEM SECTION G101 VACUUM DRAINAGE SYSTEM |
164 | INDEX INDEX |
172 | 2009 IPSDC ® INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® 2009 IPSDC ® INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® |
173 | IPSDC ® INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® 2009 TITLE PAGE IPSDC ® INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® 2009 TITLE PAGE |
174 | COPYRIGHT COPYRIGHT |
175 | PREFACE PREFACE |
177 | EFFECTIVE USE OF THE INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE EFFECTIVE USE OF THE INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE |
181 | ORDINANCE ORDINANCE |
183 | TABLE OF CONTENTS TABLE OF CONTENTS |
185 | CHAPTER 1 SCOPE AND ADMINISTRATION CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 101 GENERAL SECTION 102 APPLICABILITY SECTION 102 APPLICABILITY |
186 | PART 2—ADMINISTRATION AND ENFORCEMENT PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF PRIVATE SEWAGE DISPOSAL INSPECTION SECTION 103 DEPARTMENT OF PRIVATE SEWAGE DISPOSAL INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
187 | SECTION 105 APPROVAL SECTION 105 APPROVAL |
188 | SECTION 106 PERMITS SECTION 106 PERMITS |
189 | SECTION 107 INSPECTIONS SECTION 107 INSPECTIONS |
190 | SECTION 108 VIOLATIONS SECTION 108 VIOLATIONS |
191 | SECTION 109 MEANS OF APPEAL SECTION 109 MEANS OF APPEAL |
192 | SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
193 | CHAPTER 2 DEFINITIONS CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS SECTION 202 GENERAL DEFINITIONS |
195 | CHAPTER 3 GENERAL REGULATIONS CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 301 GENERAL SECTION 302 SPECIFIC LIMITATIONS SECTION 302 SPECIFIC LIMITATIONS SECTION 303 FLOOD HAZARD AREAS SECTION 303 FLOOD HAZARD AREAS |
197 | CHAPTER 4 SITE EVALUATION AND REQUIREMENTS CHAPTER 4 SITE EVALUATION AND REQUIREMENTS SECTION 401 GENERAL SECTION 401 GENERAL SECTION 402 SLOPE SECTION 402 SLOPE SECTION 403 SOIL BORINGS AND EVALUATION SECTION 403 SOIL BORINGS AND EVALUATION |
198 | SECTION 404 PERCOLATION OR PERMEABILITY EVALUATION SECTION 404 PERCOLATION OR PERMEABILITY EVALUATION |
199 | SECTION 405 SOIL VERIFICATION SECTION 405 SOIL VERIFICATION |
200 | SECTION 406 SITE REQUIREMENTS SECTION 406 SITE REQUIREMENTS TABLE 406.1 MINIMUM HORIZONTAL SEPARATION DISTANCES FOR SOIL ABSORPTION SYSTEMS TABLE 406.1 MINIMUM HORIZONTAL SEPARATION DISTANCES FOR SOIL ABSORPTION SYSTEMS |
202 | FIGURE 406.7.3 CONCEPTUAL DESIGN SKETCH FOR ALTERING SLOPES FIGURE 406.7.3 CONCEPTUAL DESIGN SKETCH FOR ALTERING SLOPES |
203 | CHAPTER 5 MATERIALS CHAPTER 5 MATERIALS SECTION 501 GENERAL SECTION 501 GENERAL SECTION 502 IDENTIFICATION SECTION 502 IDENTIFICATION SECTION 503 PERFORMANCE REQUIREMENTS SECTION 503 PERFORMANCE REQUIREMENTS SECTION 504 TANKS SECTION 504 TANKS TABLE 504.3 TANK CAPACITY TABLE 504.3 TANK CAPACITY |
204 | SECTION 505 PIPE, JOINTS AND CONNECTIONS SECTION 505 PIPE, JOINTS AND CONNECTIONS TABLE 505.1 PRIVATE SEWAGE DISPOSAL SYSTEM PIPE TABLE 505.1 PRIVATE SEWAGE DISPOSAL SYSTEM PIPE TABLE 505.1.1 DISTRIBUTION PIPE TABLE 505.1.1 DISTRIBUTION PIPE |
205 | SECTION 506 PROHIBITED JOINTS AND CONNECTIONS SECTION 506 PROHIBITED JOINTS AND CONNECTIONS |
207 | CHAPTER 6 SOIL ABSORPTION SYSTEMS CHAPTER 6 SOIL ABSORPTION SYSTEMS SECTION 601 GENERAL SECTION 601 GENERAL SECTION 602 SIZING SOIL ABSORPTION SYSTEMS SECTION 602 SIZING SOIL ABSORPTION SYSTEMS SECTION 603 RESIDENTIAL SIZING SECTION 603 RESIDENTIAL SIZING TABLE 603.1 MINIMUM ABSORPTION AREA FOR ONE- AND TWO-FAMILY DWELLINGS TABLE 603.1 MINIMUM ABSORPTION AREA FOR ONE- AND TWO-FAMILY DWELLINGS SECTION 604 OTHER BUILDING SIZING SECTION 604 OTHER BUILDING SIZING EQUATION 6-1 EQUATION 6-1 TABLE 604.1(1) MINIMUM ABSORPTION AREA FOR OTHER THAN ONE- AND TWO-FAMILY DWELLINGS TABLE 604.1(1) MINIMUM ABSORPTION AREA FOR OTHER THAN ONE- AND TWO-FAMILY DWELLINGS SECTION 605 INSTALLATION OF CONVENTIONAL SOIL ABSORPTION SYSTEMS SECTION 605 INSTALLATION OF CONVENTIONAL SOIL ABSORPTION SYSTEMS |
208 | TABLE 605.3 EFFECTIVE SQUARE-FOOT ABSORPTION AREA FOR SEEPAGE PITS TABLE 605.3 EFFECTIVE SQUARE-FOOT ABSORPTION AREA FOR SEEPAGE PITS |
209 | TABLE 604.1(2) CONVERSION FACTOR TABLE 604.1(2) CONVERSION FACTOR |
210 | TABLE 604.1(2)—continued CONVERSION FACTOR TABLE 604.1(2)—continued CONVERSION FACTOR |
211 | CHAPTER 7 PRESSURE DISTRIBUTION SYSTEMS CHAPTER 7 PRESSURE DISTRIBUTION SYSTEMS SECTION 701 GENERAL SECTION 701 GENERAL SECTION 702 DESIGN LOADING RATE SECTION 702 DESIGN LOADING RATE TABLE 702.1 SOIL REQUIRED TABLE 702.1 SOIL REQUIRED TABLE 702.2 DESIGN LOADING RATE TABLE 702.2 DESIGN LOADING RATE SECTION 703 SYSTEM DESIGN SECTION 703 SYSTEM DESIGN FORMULA 7-1 FORMULA 7-1 |
212 | TABLE 703.3 HAZEN-WILLIAMS FRICTION FACTOR TABLE 703.3 HAZEN-WILLIAMS FRICTION FACTOR EQUATION 7-1 EQUATION 7-1 EQUATION 7-2 EQUATION 7-2 EQUATION 7-3 EQUATION 7-3 SECTION 704 BED AND TRENCH CONSTRUCTION SECTION 704 BED AND TRENCH CONSTRUCTION SECTION 705 PUMPS SECTION 705 PUMPS SECTION 706 DOSING SECTION 706 DOSING |
213 | TABLE 706.1 ESTIMATED VOLUME FOR VARIOUS DIAMETER PIPES TABLE 706.1 ESTIMATED VOLUME FOR VARIOUS DIAMETER PIPES |
215 | CHAPTER 8 TANKS CHAPTER 8 TANKS SECTION 801 GENERAL SECTION 801 GENERAL SECTION 802 SEPTIC TANKS AND OTHER TREATMENT TANKS SECTION 802 SEPTIC TANKS AND OTHER TREATMENT TANKS TABLE 802.7.1 SEPTIC TANK CAPACITY FOR ONE- AND TWO-FAMILY DWELLINGS TABLE 802.7.1 SEPTIC TANK CAPACITY FOR ONE- AND TWO-FAMILY DWELLINGS |
216 | TABLE 802.8 MINIMUM HORIZONTAL SEPARATION DISTANCES FOR TREATMENT TANKS TABLE 802.8 MINIMUM HORIZONTAL SEPARATION DISTANCES FOR TREATMENT TANKS TABLE 802.11.1 PUMP CHAMBER SIZES TABLE 802.11.1 PUMP CHAMBER SIZES SECTION 803 MAINTENANCE AND SLUDGE DISPOSAL SECTION 803 MAINTENANCE AND SLUDGE DISPOSAL SECTION 804 CHEMICAL RESTORATION SECTION 804 CHEMICAL RESTORATION |
217 | TABLE 802.7.2 ADDITIONAL CAPACITY FOR OTHER BUILDINGS TABLE 802.7.2 ADDITIONAL CAPACITY FOR OTHER BUILDINGS |
218 | TABLE 802.7.2—continued ADDITIONAL CAPACITY FOR OTHER BUILDINGS TABLE 802.7.2—continued ADDITIONAL CAPACITY FOR OTHER BUILDINGS SECTION 805 HOLDING TANKS SECTION 805 HOLDING TANKS TABLE 805.2 MINIMUM LIQUID CAPACITY OF HOLDING TANKS TABLE 805.2 MINIMUM LIQUID CAPACITY OF HOLDING TANKS |
219 | CHAPTER 9 MOUND SYSTEMS CHAPTER 9 MOUND SYSTEMS SECTION 901 GENERAL SECTION 901 GENERAL SECTION 902 SOIL AND SITE REQUIREMENTS SECTION 902 SOIL AND SITE REQUIREMENTS TABLE 902.2 MINIMUM SOIL DEPTHS FOR MOUND SYSTEM INSTALLATION TABLE 902.2 MINIMUM SOIL DEPTHS FOR MOUND SYSTEM INSTALLATION SECTION 903 SYSTEM DESIGN SECTION 903 SYSTEM DESIGN |
220 | EQUATION 9-1 EQUATION 9-1 EQUATION 9-2 EQUATION 9-2 EQUATION 9-3 EQUATION 9-3 EQUATION 9-4 EQUATION 9-4 EQUATION 9-5 EQUATION 9-5 |
221 | TABLE 903.1(1) DESIGN CRITERIA FOR A MOUND FOR A ONE-BEDROOM HOME ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 150 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL TABLE 903.1(1) DESIGN CRITERIA FOR A MOUND FOR A ONE-BEDROOM HOME ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 150 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL TABLE 903.1(2) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL TABLE 903.1(2) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL |
222 | TABLE 903.1(3) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL TABLE 903.1(3) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL |
223 | TABLE 903.1(4) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL TABLE 903.1(4) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 6-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR SLOWLY PERMEABLE SOIL |
224 | TABLE 903.1(5) DESIGN CRITERIA FOR A ONE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPEWITH LOADING RATES OF 150 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK TABLE 903.1(5) DESIGN CRITERIA FOR A ONE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPEWITH LOADING RATES OF 150 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK |
225 | TABLE 903.1(6) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK TABLE 903.1(6) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK |
226 | TABLE 903.1(7) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK TABLE 903.1(7) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK |
227 | TABLE 903.1(8) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK TABLE 903.1(8) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR SHALLOW PERMEABLE SOIL OVER CREVICED BEDROCK |
228 | TABLE 903.1(9) DESIGN CRITERIA FOR A ONE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 150 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE TABLE 903.1(9) DESIGN CRITERIA FOR A ONE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 150 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE |
229 | TABLE 903.1(10) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE TABLE 903.1(10) DESIGN CRITERIA FOR A TWO-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 300 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE |
230 | TABLE 903.1(11) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE TABLE 903.1(11) DESIGN CRITERIA FOR A THREE-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 450 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE |
231 | TABLE 903.1(12) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE TABLE 903.1(12) DESIGN CRITERIA FOR A FOUR-BEDROOM HOME FOR A MOUND ON A 0- TO 12-PERCENT SLOPE WITH LOADING RATES OF 600 GALLONS PER DAY FOR PERMEABLE SOIL WITH A HIGH WATER TABLE |
232 | EQUATON 9-6 EQUATON 9-6 EQUATION 9-7 EQUATION 9-7 TABLE 903.5.5 DOWNSLOPE AND UPSLOPE WIDTH CORRECTIONS FOR MOUNDS ON SLOPING SITES TABLE 903.5.5 DOWNSLOPE AND UPSLOPE WIDTH CORRECTIONS FOR MOUNDS ON SLOPING SITES EQUATION 9-8 EQUATION 9-8 TABLE 903.6 INFILTRATIVE CAPACITY OF NATURAL SOIL TABLE 903.6 INFILTRATIVE CAPACITY OF NATURAL SOIL EQUATION 9-9 EQUATION 9-9 EQUATION 9-10 EQUATION 9-10 EQUATION 9-11 EQUATION 9-11 EQUATION 9-12 EQUATION 9-12 SECTION 904 CONSTRUCTION TECHNIQUES SECTION 904 CONSTRUCTION TECHNIQUES |
235 | CHAPTER 10 CESSPOOLS CHAPTER 10 CESSPOOLS SECTION 1001 GENERAL SECTION 1001 GENERAL |
237 | CHAPTER 11 RESIDENTIAL WASTE WATER SYSTEMS CHAPTER 11 RESIDENTIAL WASTE WATER SYSTEMS SECTION 1101 GENERAL SECTION 1101 GENERAL |
239 | CHAPTER 12 INSPECTIONS CHAPTER 12 INSPECTIONS SECTION 1201 GENERAL SECTION 1201 GENERAL SECTION 1202 INSPECTIONS SECTION 1202 INSPECTIONS |
241 | CHAPTER 13 NONLIQUID SATURATED TREATMENT SYSTEMS CHAPTER 13 NONLIQUID SATURATED TREATMENT SYSTEMS SECTION 1301 GENERAL SECTION 1301 GENERAL |
243 | CHAPTER 14 REFERENCED STANDARDS CHAPTER 14 REFERENCED STANDARDS ASTM ASTM |
244 | CSA CSA CISPI CISPI ICC ICC NSF NSF UL UL |
245 | APPENDIX A SYSTEM LAYOUT ILLUSTRATIONS APPENDIX A SYSTEM LAYOUT ILLUSTRATIONS FIGURE A-1 (SECTION 403.1.1) EXAMPLE OF SOIL-BORING LOCATIONS FOR TWO CONTIGUOUS ABSORPTION AREAS FIGURE A-1 (SECTION 403.1.1) EXAMPLE OF SOIL-BORING LOCATIONS FOR TWO CONTIGUOUS ABSORPTION AREAS FIGURE A-2 (SECTION 405.2.4) MONITORING WELL DESIGN FIGURE A-2 (SECTION 405.2.4) MONITORING WELL DESIGN |
246 | FIGURE A-3 (SECTION 406.6.7) DESIGN OF FILLED AREA SYSTEM FIGURE A-3 (SECTION 406.6.7) DESIGN OF FILLED AREA SYSTEM FIGURE A-4 (SECTION 605.7)OBSERVATION PIPE FIGURE A-4 (SECTION 605.7)OBSERVATION PIPE |
247 | FIGURE A-5 (SECTION 703.1) PRESSURE DISTRIBUTION SYSTEM DESIGN FIGURE A-5 (SECTION 703.1) PRESSURE DISTRIBUTION SYSTEM DESIGN FIGURE A-6 (SECTION 903.1) MOUND USING THREE TRENCHES FOR ABSORPTION AREA FIGURE A-6 (SECTION 903.1) MOUND USING THREE TRENCHES FOR ABSORPTION AREA |
248 | FIGURE A-7 (SECTION 903.1) PLAN VIEW OF MOUND USING A BED FOR THE ABSORPTION AREA FIGURE A-7 (SECTION 903.1) PLAN VIEW OF MOUND USING A BED FOR THE ABSORPTION AREA FIGURE A-8 (SECTION 903.1) CROSS SECTION OF A MOUND SYSTEM USING THREE TRENCHES FOR THE ABSORPTION AREA FIGURE A-8 (SECTION 903.1) CROSS SECTION OF A MOUND SYSTEM USING THREE TRENCHES FOR THE ABSORPTION AREA |
249 | FIGURE A-9 (SECTION 903.1) CROSS SECTION OF A MOUND SYSTEM USING A BED FOR THE ABSORPTION AREA FIGURE A-9 (SECTION 903.1) CROSS SECTION OF A MOUND SYSTEM USING A BED FOR THE ABSORPTION AREA FIGURE A-10 (SECTION 903.1) DISTRIBUTION PIPE LAYOUT FIGURE A-10 (SECTION 903.1) DISTRIBUTION PIPE LAYOUT |
251 | APPENDIX B TABLES FOR PRESSURE DISTRIBUTION SYSTEMS APPENDIX B TABLES FOR PRESSURE DISTRIBUTION SYSTEMS TABLE B-1 REQUIRED DISTRIBUTION PIPE DIAMETERS FOR VARIOUS HOLE DIAMETERS,HOLE SPACINGS AND DISTRIBUTION PIPE LENGTHS (SCHEDULE 40 PLASTIC PIPE) TABLE B-1 REQUIRED DISTRIBUTION PIPE DIAMETERS FOR VARIOUS HOLE DIAMETERS,HOLE SPACINGS AND DISTRIBUTION PIPE LENGTHS (SCHEDULE 40 PLASTIC PIPE) TABLE B-2a DISTRIBUTION PIPE DISCHARGE RATE TABLE B-2a DISTRIBUTION PIPE DISCHARGE RATE |
252 | TABLE B-3 RECOMMENDED MANIFOLD DIAMETERS FOR VARIOUS MANIFOLD LENGTHS, NUMBER OF DISTRIBUTION PIPES AND DISTRIBUTION PIPE DISCHARGE RATES (SCHEDULE 40 PLASTIC PIPE) TABLE B-3 RECOMMENDED MANIFOLD DIAMETERS FOR VARIOUS MANIFOLD LENGTHS, NUMBER OF DISTRIBUTION PIPES AND DISTRIBUTION PIPE DISCHARGE RATES (SCHEDULE 40 PLASTIC PIPE) TABLE B-4a PUMP DOSING RATE TABLE B-4a PUMP DOSING RATE |
253 | TABLE B-5 FRICTION LOSSa IN SCHEDULE 40 PLASTIC PIPE (C = 150) TABLE B-5 FRICTION LOSSa IN SCHEDULE 40 PLASTIC PIPE (C = 150) |
254 | TABLE B-6a MINIMUM DOSE VOLUME BASED ON PIPE SIZE, LENGTH AND NUMBER TABLE B-6a MINIMUM DOSE VOLUME BASED ON PIPE SIZE, LENGTH AND NUMBER |
255 | INDEX INDEX |
261 | ICC-ES PMG LISTING PROGRAM ICC-ES PMG LISTING PROGRAM |
262 | ICC MEMBERSHIP INFORMATION ICC MEMBERSHIP INFORMATION |
263 | ICC TRAINING INFORMATION ICC TRAINING INFORMATION |
264 | 2009 I-CODES SIGNIFICANT CHANGES SERIES 2009 I-CODES SIGNIFICANT CHANGES SERIES ECODES.BIZ ECODES.BIZ |