IEEE C37.011-2019
$91.54
IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V
Published By | Publication Date | Number of Pages |
IEEE | 2019 | 127 |
Revision Standard – Active. The procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.011™-2019 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
10 | Contents |
11 | List of Figures |
14 | List of Tables |
15 | IMPORTANT NOTICE 1. Overview 1.1 Scope 1.2 Purpose 2. Normative references |
16 | 3. Transient recovery voltage 3.1 General |
17 | 3.2 Arc-circuit interaction |
18 | 3.3 Method of rating and application |
29 | 4. Application considerations 4.1 General |
32 | 4.2 Circuit breaker capability |
62 | 4.3 Exponential (overdamped) TRV |
64 | 4.4 Oscillatory (underdamped) TRV |
75 | 4.5 Application where circuit breaker capability may be exceeded |
79 | 5. Testing issues 5.1 General |
80 | 5.2 Application of TRV test data to a multi-break interrupter |
82 | Annex A (informative) Transient recovery voltage (TRV) calculation techniques A.1 Typical system for TRV calculation |
83 | A.2 Transient recovery voltage types |
93 | A.3 Equivalent circuit representation |
98 | A.4 Example of transient recovery voltage calculation |
104 | Annex B (informative) Typical capacitance values for various equipment |
111 | Annex C (informative) Selection of the first-pole-to-clear factors and factors for second and third poles to clear C.1 Selection of the first-pole-to-clear factor C.2 Factors for each pole to clear |
116 | Annex D (informative) Guidance for transient recovery voltage (TRV) calculation by electromagnetic transients program D.1 General D.2 Transformer-fed and transformer-limited fault D.3 Current-limiting reactor-limited fault |
117 | D.4 Short-line fault (SLF) |
119 | D.5 General station model |
121 | D.6 Calculation of circuit breaker TRV and rate-of-rise-of-recovery voltage (RRRV) |
123 | Annex E (informative) Abbreviations |
124 | Annex F (informative) (Bibliography) |
127 | Back cover |