IEEE C37.017-2020
$30.33
IEEE Standard for Bushings for High-Voltage (Over 1000 Vac) Circuit Breakers and Gas-Insulated Switchgear
Published By | Publication Date | Number of Pages |
IEEE | 2020 | 35 |
Revision Standard – Active. This standard is applicable to bushings intended for use in high-voltage circuit breakers and gas-insulated switchgear. These bushings are intended for indoor and outdoor use, operating on alternating current with a rated voltage greater than 1000 V and a frequency of 50 Hz or 60 Hz. These bushings are usually a part of an apparatus and tested according to the apparatus of which they form part.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.017™-2020 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | 1. Overview 1.1 Scope 1.2 Purpose 1.3 Word usage |
14 | 2. Normative references |
15 | 3. Definitions, acronyms, and abbreviations 4. Normal (usual) and special (unusual) service conditions 4.1 General |
16 | 4.2 Normal (usual) service conditions 4.3 Special (unusual) service conditions for both indoor and outdoor applications 5. Ratings 5.1 General |
17 | 5.2 Rated maximum voltage 5.3 Rated insulation level 5.4 Rated power frequency 5.5 Rated continuous current and temperature rise 5.6 Rated short-time withstand current 5.7 Rated peak withstand current |
18 | 5.8 Rated duration of short circuit current 6. Design and construction 6.1 General 6.2 External insulation housing 6.3 Angle of mounting 6.4 Creepage distance 6.5 Terminal loading, minimum withstand values |
19 | 6.6 Seismic qualification 6.7 Nameplate markings |
20 | 7. Hollow insulators tests 7.1 General 7.2 Ceramic hollow insulators |
22 | 7.3 Composite hollow insulators |
24 | 8. Tests on bushings 8.1 General requirements for tests 8.2 Classification of tests |
25 | 8.3 Condition of bushings during tests |
26 | 8.4 Specimen to be tested 9. Design tests on bushings 9.1 Dielectric tests |
29 | 9.2 Artificial pollution tests 9.3 Radio influence voltage and partial discharge measurement tests |
30 | 9.4 Temperature-rise tests 9.5 Verification of short-time current withstand 9.6 Cantilever load withstand test |
31 | 9.7 Tightness tests 9.8 Internal pressure test on gas-insulated bushings 9.9 Verification of dimensions 9.10 Information to be included in design-test (type-test) reports |
32 | 10. Routine (production) tests 10.1 General 10.2 Dry power-frequency voltage withstand 10.3 Partial discharge test |
33 | 10.4 Internal pressure test 10.5 Tightness test 10.6 Design and visual checks |
34 | Annex A (informative) Bibliography |
35 | Back cover |