Revision Standard – Active. Metal-clad (MC) medium-voltage switchgear that contains drawout electrically operated circuit breakers is covered. MC switchgear is compartmentalized to isolate components such as instrumentation, main bus, and both incoming and outgoing connections with grounded metal barriers. Ranges from 4.76 kV to 48.3 kV with main bus continuous current ratings of 1200 A, 2000 A, 3000 A, and 4000 A are the rated maximum voltage levels for metal-clad switchgear . Associated control, instruments, metering, relaying, protective, and regulating devices, as necessary, are also contained by MC switchgear. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and applications are discussed.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.20.2™-2022 Front Cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Participants
9 Introduction
11 Contents
13 1. Overview
1.1 Scope
1.2 Purpose
1.3 Word usage
14 2. Normative references
16 3. Definitions
18 4. Service conditions
19 5. Ratings
5.1 General
20 5.2 Voltage and insulation levels
21 5.3 Rated power frequency
5.4 Rated current
22 5.5 Temperature limitations
24 5.6 Current transformer ratings
5.7 Current transformer accuracies
25 5.8 Voltage transformers
5.9 Other devices
6. Tests
6.1 General
26 6.2 Design tests
45 6.3 Production tests
46 6.4 Field dielectric tests
47 6.5 Optional tests
7. Construction
7.1 Buses and primary connections
48 7.2 Grounding and bonding
7.3 Control and secondary circuits and devices
53 7.4 Miscellaneous
54 7.5 Materials, finishes, and color
55 7.6 Precautionary labels
7.7 Metallic barriers
56 7.8 Shutters
7.9 Insulating materials for covering buses and connections
57 7.10 Interlocks
7.11 Interchangeability of removable switching and interrupting devices
7.12 Primary fuses and transformers
58 7.13 Secondary disconnect devices
7.14 Control wiring
7.15 Handling device
7.16 Test cabinet
59 7.17 Indoor MC switchgear, access, and ventilation
7.18 Outdoor MC switchgear, access, and ventilation
7.19 Circuit breaker open/close position indication
7.20 Enclosure categories
7.21 Ground and test devices
60 7.22 Load interrupter switches
7.23 Voltage dividers
8. Application guide for MC switchgear
8.1 Unusual service conditions
63 8.2 System characteristics—voltage and frequency
64 8.3 Overvoltage considerations—insulation levels
8.4 Continuous current rating and overload capability
70 8.5 Short-circuit considerations
71 8.6 Nuclear power plant application
8.7 Associated devices often used in MC switchgear
72 8.8 Protection and isolation of switchgear connected to other circuit protective equipment
73 9. Guide for handling, storage, and installation
9.1 General
9.2 Handling
75 9.3 Preoperation check
9.4 Removable elements
9.5 Interlocks
76 9.6 Energizing
77 Annex A (informative) Bibliography
79 Annex B (normative) Guide for enclosure categories and related requirements
B.2.1 Category A enclosures
B.2.2 Category B enclosures
80 B.2.3 Category C enclosures
81 B.3.1 Equivalent construction
B.3.2 Access doors and covers
82 B.3.3 Enclosure and ventilation openings
83 B.3.4 Operating handle protection
B.3.5 Operating handles
B.3.6 Viewing panes
B.3.7 Accessories
84 B.3.8 Outdoor enclosure requirements
B.3.9 Exposed live parts
B.3.10 Exposed fasteners
B.3.11 External marking
85 Annex C (informative) Partial discharge testing
87 C.4.1 General
C.4.2 Test setup
88 C.4.3 Calibration
C.4.4 Test procedure
91 Annex D (normative) Voltage dividers
92 D.4.1 Dielectric withstand test
93 D.4.2 Voltage divider specific test
D.4.3 Voltage dividers used as bus supports or braces
94 Back Cover