1.1 These test methods cover the determination of cyanides in water. The following test methods are included:
1.2 Cyanogen halides may be determined separately. Cyanogen chloride is the most common of the cyanogen halide complexes as it is a reaction product and is usually present when chlorinating cyanide-containing industrial waste water. For the presence or absence of CNCl, the spot test method given in can be used.
1.3 These test methods do not distinguish between cyanide ions and metallocyanide compounds and complexes. Furthermore, they do not detect the cyanates. Note 1The cyanate complexes are decomposed when the sample is acidified in the distillation procedure.
1.4 The cyanide in cyanocomplexes of gold, platinum, cobalt and some other transition metals is not completely recovered by these test methods.
1.5 Cyanide from only a few organic cyanides are recovered, and those only to a minor extent.
1.6 Part or all of these test methods have been used successfully with reagent water and various waste waters. It is the user’s responsibility to assure the validity of the test method for the water matrix being tested.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in sections 5.1, 8.8, 8.18, 9, 11.2, and 16.1.9.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Test Methods |
2 | Significance and Use Interferences Apparatus FIG. 1 |
3 | Reagents and Materials |
4 | Hazards Sample and Sample Preservation Elimination of Interferences |
5 | Scope Interferences Apparatus Reagents and Materials Procedure |
6 | TABLE 1 |
7 | Calculation Precision and Bias |
8 | Scope Interferences Apparatus Reagents and Materials Procedure Calculation TABLE 2 |
9 | Precision and Bias Scope TABLE 3 TABLE 4 |
10 | Interferences Apparatus Reagents and Materials Procedure Calculation Precision and Bias TABLE 5 TABLE 6 |
11 | Scope Interferences Apparatus Reagents and Materials TABLE 7 |
12 | Standardization Procedure Precision and Bias Quality Assurance/Quality Control TABLE 8 |
13 | TABLE 9 TABLE 10 |
14 | Keywords A1. SPOT TEST FOR SAMPLE SCREENING A1.1 Scope A1.2 Interferences A1.3 Apparatus A1.4 Reagents and Materials A1.5 Procedure |
15 | X1. CYANIDE X1.1 X1.2 |
16 | X1.3 X1.4 FIG. X1.1 |
17 | X1.5 X1.6 X1.7 X1.8 |
18 | X1.9 TABLE X1.1 |
19 | X2. DETECTION AND ELIMINATION OF THE INTERFERENCE CAUSED BY ALDEHYDES X2.1 Introductory Comments X2.2 Summary of Methods X2.3 Description of Spot Test X2.4 Apparatus X2.5 Reagents and Materials X2.6 Procedure |
20 | REFERENCES |