ASTM E1502-10

Historical Standard: Standard Guide for Use of Fixed-Point Cells for Reference Temperatures

ASTM E1502

Scope

1.1 This guide describes the essential features of fixed-point cells and auxiliary apparatus, and the techniques required to realize fixed points in the temperature range from 29 to 1085Ā°C.

1.2 Design and construction requirements of fixed-point cells are not addressed in this guide. Typical examples are given in Fig. 1 and Fig. 2.

1.3 This guide is intended to describe good practice and establish uniform procedures for the realization of fixed points.

1.4 This guide emphasizes principles. The emphasis on principles is intended to aid the user in evaluating cells, in improving technique for using cells, and in establishing procedures for specific applications.

1.5 For the purposes of this guide, the use of fixed-point cells for the accurate calibration of thermometers is restricted to immersion-type thermometers that, when inserted into the reentrant well of the cell, (1) indicate the temperature only of the isothermal region of the well, and (2) do not significantly alter the temperature of the isothermal region of the well by heat transfer.

1.6 This guide does not address all of the details of thermometer calibration.

1.7 This guide is intended to complement special operating instructions supplied by manufacturers of fixed-point apparatus.

1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9 The following hazard caveat pertains only to the test method portion, Section 7, of this guide. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

calibration; cryoscopic constant; fixed point; freeze; freezing curve; freezing plateau; freezing point; freezing range; ITS-90; melt; melting curve; melting plateau; melting point; melting range; precision; qualification; recalescence; reference material reference temperature; resistance thermometer; thermocouple; thermometer; uncertainty; undercool; Calibration–temperature analysis instrumentation; Cryoscopic constant; Freezing point; ITS-90; Qualification testing; Recalescence; Reference materials (RM); Reference temperature; Resistance thermometers; Thermocouples; Thermometers; Undercool

ICS Code

ICS Number Code 17.200.20 (Temperature-measuring instruments)

DOI: 10.1520/E1502-10

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
FIG. 1
FIG. 2
FIG. 3
3 Summary of Guide
FIG. 4
FIG. 5
FIG. 6
4 Significance and Use
Principles
TABLE 1
TABLE 2
8 Test Procedureā€”Freezing
9 Test Procedureā€”Melting
10 Documentation
11 Precision and Bias
12 Keywords