Shopping Cart

No products in the cart.

ASTM-E906 2004

$58.50

E906-04 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products

Published By Publication Date Number of Pages
ASTM 2004 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E906-04

Historical Standard: Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products

ASTM E906

Scope

1.1 This test method can be used to determine the release rates of heat and visible smoke (Note 1) from materials and products when exposed to different levels of radiant heat using the test apparatus, specimen configurations, and procedures described in this test method.

Note 1-Visible smoke is described in terms of the obscuration of transmitted light caused by combustion products release during the tests (see 10.2.1).

1.2 This test method provides for radiant thermal exposure of a specimen both with and without a pilot. Piloted ignition may be effected by direct flame impingement on the specimen (piloted, point ignition) or by placing the pilot to ignite gases evolved by pyrolysis of the specimen.

1.3 Heat and smoke release are measured from the moment the specimen is injected into a controlled exposure chamber. The measurements are continued during the period of ignition (and progressive flame involvement of the surface in the case of point ignition), and to such a time that the test is terminated.

1.4 This test method tests materials and products under a constant, imposed, external heat flux that may be varied from 0 to 100 kW/m .

1.5 This test method is intended for use in research and development and not as a basis for rating, regulatory, or code purposes.

1.6 This standard should be used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions and should not be used to describe or appraise the fire-hazard or fire-risk of materials, products, or assemblies under actual fire conditions. However, results of the test may be used as elements of a fire-hazard assessment or a fire-risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard or fire risk of a particular end use.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

calorimetry; ignitability; heat release; smoke obscuration; smoke release

ICS Code

ICS Number Code 13.220.50 (Fire-resistance of building materials and elements)

DOI: 10.1520/E0906-04

PDF Catalog

PDF Pages PDF Title
1 Scope
2 Referenced Documents
Terminology
Summary of Test Method
Significance and Use
3 Operator Safety
Sample Preparation
Release Rate Apparatus—Configuration A
4 FIG. 1
5 FIG. 2
7 FIG. 3
8 FIG. 4
9 Calibration of Equipment—Configuration A
FIG. 5
FIG. 6
10 FIG. 7
FIG. 8
11 Test Procedure and Calculations—Configuration A
Release Rate Apparatus—Configuration B
12 FIG. 9
13 FIG. 10
FIG. 11
FIG. 12
FIG. 13
FIG. 14
14 FIG. 15
FIG. 16
15 FIG. 17
16 FIG. 18
17 Calibration of Equipment—Configuration B
FIG. 19
18 FIG. 20
19 Test Procedure—Configuration B
FIG. 21
20 FIG. 22
21 Calculations—Configuration B
FIG. 23
22 Report
23 Keywords
X1. RELEASE RATE TESTS
X1.1
X1.2
X1.3
X2. RELEASE RATE CALIBRATION
X2.1
X2.2
X2.3
TABLE 1
24 X2.4
X2.5
FIG. X2.1
25 X3. FLUX DISTRIBUTION
X3.1
X4. RADIATION REFLECTOR FOR HORIZONTAL SPECIMENS
X4.1
FIG. X2.2
26 X5. COMMENTARY
X5.1
X5.2
X5.3
X5.4
X5.5
X5.6
ASTM-E906 2004