New IEEE Standard – Inactive – Superseded. The electrical, mechanical, and physical requirements of oil-immersed and dry-type air core smoothing reactors for high-voltage direct current (HVDC) applications are specified. Test code is defined and appropriate technical background information is presented or identified.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1277-2000 Front Cover |
3 | Title Page Abstract/Keywords |
5 | Introduction Notice to users Law and regulations Copyrights Updating of IEEE documents |
6 | Errata Interpretations Patents Participants |
8 | Contents |
13 | 3. Definitions |
14 | 4. Letter symbols |
15 | 5. General requirements-systems and environmental data 5.1 Usual service conditions 5.2 Unusual service conditions |
18 | 6. Rating data 6.1 Basis for rating 6.2 Rated dc voltage 6.3 Rated currents |
19 | 6.4 Inductance 6.5 Basic impulse insulation level (BIL) |
20 | 6.6 Cooling classes 6.7 Other specification requirements |
23 | 7. Construction of oil-immersed smoothing reactors 7.1 Tank and tank components for oil-immersed smoothing reactors |
24 | 7.2 Oil preservation for oil-immersed smoothing reactors |
26 | 7.3 Auxiliary equipment for oil-immersed smoothing reactors |
28 | 8. Tests 8.1 General 8.2 Routine, design, and other tests for smoothing reactors |
32 | 9. Losses and inductance 9.1 Losses |
33 | 9.2 Inductance 10. Temperature rise and loading conditions 10.1 Temperature-rise limits and loading conductors |
34 | 10.2 Temperature of metalic parts in contact with insulation 10.3 Temperature of other metalic parts 10.4 Temperature rise of insulating liquid 10.5 Temperature rise of terminals |
35 | 11. Dielectric tests and insulation levels 11.1 Impulse tests 11.2 DC voltage tests |
36 | 11.3 DC polarity-reversal test with partial discharge measurements for oil- immersed smoothing reactors 11.4 Low-frequency voltage tests on line terminals |
37 | 12. Test code 12.1 General 12.2 Resistance measurements |
39 | 12.3 Losses and impedance |
43 | 12.4 Temperature-rise test |
49 | 12.5 Dielectric tests for oil-immersed smoothing reactors |
57 | 12.6 Dielectric tests for dry-type smoothing reactors |
62 | 12.7 Audible sound level test |
66 | 12.8 Short-circuit withstand verification |
67 | 12.9 Capacitor discharge test 12.10 DC power test for oil-immersed and dry-type SMRs |
68 | 12.11 Seismic verification test 12.12 Nameplates for oil-immersed and dry-type smoothing reactors |
71 | Annex A (informative) Application of HVDC smoothing reactors |
77 | Annex B (informative) Construction and installation of dry-type air-core smoothing reactors for HVDC application |
80 | Annex C (informative) Short-circuit capability |
83 | Annex D (informative)Bibliography |