{"id":262362,"date":"2024-10-19T17:24:02","date_gmt":"2024-10-19T17:24:02","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-68912005a22008\/"},"modified":"2024-10-25T13:14:12","modified_gmt":"2024-10-25T13:14:12","slug":"bs-68912005a22008","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-68912005a22008\/","title":{"rendered":"BS 6891:2005+A2:2008"},"content":{"rendered":"

The Standard specifies the design, installation and commissioning criteria for steel, copper or corrugated stainless steel semi-rigid pipe, in sizes not exceeding BS 1387 for steel and DN 32 for corrugated stainless steel or copper, low pressure gas installation pipework. This standard applies to gas pipework for the supply of 2nd family gas from the meter to appliances in domestic premises where the nominal working operating pressure is 21 mbar. Those likely to have an interest in the standard will be architects, builders, surveyors, building inspectors, consulting engineers, gas transporters and gas installers. Complying with this standard will ensure a correctly designed, installed and commissioned system that will operate safely in the domestic housing environment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nBRITISH STANDARD <\/td>\n<\/tr>\n
2<\/td>\nCommittees responsible for this British Standard <\/td>\n<\/tr>\n
3<\/td>\nContents <\/td>\n<\/tr>\n
5<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
7<\/td>\n3 Terms and definitions
control valves
emergency control valve (ECV)
additional emergency control valve (AECV)
ducts and voids
duct
void
installation pipework, meters and fittings
installation pipework
meter installation <\/td>\n<\/tr>\n
8<\/td>\nmeter installation inlet valve
primary meter
sleeve
termination point
protected shaft
service (pipe) <\/td>\n<\/tr>\n
9<\/td>\nTypical installation
4 Competence
4.1 Persons carrying out the installation shall be competent.
4.2 The installation work shall be carried out by a business or self-employed person who is a \u201cmember of a class of persons approved for the time being by the Health and Safety Executive\u201d (HSE).
4.3 Persons who design the system or installation shall have a knowledge and understanding of the standards and regulations that apply to ensure that the completed work will produce a safe and satisfactory installation. <\/td>\n<\/tr>\n
10<\/td>\n5 Design and planning
5.1 Exchange of information and time schedule
5.2 Pipe sizing <\/td>\n<\/tr>\n
11<\/td>\nDischarge in a straight horizontal pipe with a 1.0 mbar differential pressure between the ends for the gas of relative density 0.6 (air = 1)
6 Materials
6.1 General
6.2 Steel
6.3 Malleable iron <\/td>\n<\/tr>\n
12<\/td>\n6.4 Copper
6.5 Polyethylene
6.6 Thread sealing
7 Fittings
7.1 Valves
7.2 Capillary fittings
7.3 Compression fittings
7.4 Push-fit fittings
7.5 Union joints <\/td>\n<\/tr>\n
13<\/td>\n7.6 Screwed joints
Thread wrapping method
8 Installation
8.1 General
8.2 Connection to the meter installation <\/td>\n<\/tr>\n
14<\/td>\n8.3 Jointing
8.4 Safety precautions
8.5 Installation of PE pipework <\/td>\n<\/tr>\n
15<\/td>\n8.6 Connection and disconnection of pipes and fittings
Use of temporary continuity bond <\/td>\n<\/tr>\n
16<\/td>\n8.7 Pipes laid in joisted floors
Maximum interval between pipe supports <\/td>\n<\/tr>\n
17<\/td>\nLimits for notching and drilling of solid timber floor joists <\/td>\n<\/tr>\n
18<\/td>\n8.8 Pipes buried in concrete ground floors
8.9 Pipes in walls <\/td>\n<\/tr>\n
20<\/td>\nTypical examples of buried pipe <\/td>\n<\/tr>\n
21<\/td>\nTypical examples of buried pipe <\/td>\n<\/tr>\n
22<\/td>\nTypical examples of buried pipe <\/td>\n<\/tr>\n
23<\/td>\nTypical examples of pipes in masonry and timber frame walls <\/td>\n<\/tr>\n
24<\/td>\nTypical examples of pipes in masonry and timber frame walls <\/td>\n<\/tr>\n
25<\/td>\nTypical examples of pipes in masonry and timber frame walls <\/td>\n<\/tr>\n
26<\/td>\nTypical examples of pipes in masonry and timber frame walls <\/td>\n<\/tr>\n
27<\/td>\n8.10 Sleeves
8.11 Pipework in ducts
Free area of ventilation openings <\/td>\n<\/tr>\n
28<\/td>\n8.12 Multi-dwelling buildings <\/td>\n<\/tr>\n
29<\/td>\nTypical installation pipework in multi-storey buildings containing flats or maisonettes <\/td>\n<\/tr>\n
30<\/td>\nTypical installation pipework in multi-storey buildings containing flats or maisonettes <\/td>\n<\/tr>\n
31<\/td>\n8.13 Gas pipework inside a protected shaft containing a stair and\/or lift or other protected fire escape route
8.14 Pipe supports and fixings
8.15 Exterior pipework
Buried external pipework <\/td>\n<\/tr>\n
32<\/td>\nTypical exterior pipework
8.16 Interrelation with other services <\/td>\n<\/tr>\n
34<\/td>\nPosition of main equipotential bonding connection
Typical notification where main equipotential bonding is found not to be present
8.17 Valves <\/td>\n<\/tr>\n
35<\/td>\n9 Prevention of corrosion and degradation
9.1 General <\/td>\n<\/tr>\n
36<\/td>\n9.2 Buried pipework
10 Gas tightness testing and purging <\/td>\n<\/tr>\n
37<\/td>\n(informative) Guide for sizing gas supplies
(informative) Guide for sizing gas supplies <\/td>\n<\/tr>\n
38<\/td>\nExample of a pipe-sizing calculation <\/td>\n<\/tr>\n
39<\/td>\nSizing results <\/td>\n<\/tr>\n
40<\/td>\nExample of a pipe-sizing calculation <\/td>\n<\/tr>\n
41<\/td>\nSizing results <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Installation of low pressure gas pipework of up to 35 mm (R1 1\/4)in domestic premises (2nd family gas). Specification<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2008<\/td>\n44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":262367,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1275,2641],"product_tag":[],"class_list":{"0":"post-262362","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-140-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/262362","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/262367"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=262362"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=262362"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=262362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}