{"id":397753,"date":"2024-10-20T04:32:05","date_gmt":"2024-10-20T04:32:05","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1222-2011-2\/"},"modified":"2024-10-26T08:20:07","modified_gmt":"2024-10-26T08:20:07","slug":"ieee-1222-2011-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1222-2011-2\/","title":{"rendered":"IEEE 1222-2011"},"content":{"rendered":"

Revision Standard – Superseded. This standard covers the construction, mechanical, electrical and optical performance, installation guidelines, acceptance criteria, test requirements, and environmental considerations for an all-dielectric self-supporting fiber optic cable designed to be located on overhead electric power utility and telecommunications facilities. This does not include cables used for underground installations.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1222-2011 Front Cover <\/td>\n<\/tr>\n
3<\/td>\nTitle page <\/td>\n<\/tr>\n
6<\/td>\nIntroduction
Notice to users
Laws and regulations <\/td>\n<\/tr>\n
7<\/td>\nCopyrights
Updating of IEEE documents
Errata
Interpretations
Patents <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nContents <\/td>\n<\/tr>\n
11<\/td>\n1. Overview
1.1 Scope
1.2 Purpose <\/td>\n<\/tr>\n
12<\/td>\n2. Normative references
2.1 Optical fiber standards
2.2 Test standards <\/td>\n<\/tr>\n
13<\/td>\n3. Definitions
3.1 General definitions <\/td>\n<\/tr>\n
14<\/td>\n3.2 Electrical definitions
4. ADSS cable and components
4.1 Description
4.2 Fiber optic cable core <\/td>\n<\/tr>\n
15<\/td>\n4.2.1 Fiber strain allowance
4.2.2 Central strength element
4.2.3 Buffer tube filling compound
4.2.4 Cable core water blocking compound
4.2.5 Binder\/tape
4.2.6 Inner jacket
4.3 Optical fibers <\/td>\n<\/tr>\n
16<\/td>\n4.4 Buffer construction
4.4.1 Loose buffer
4.5 Color coding and performance
4.6 Jackets <\/td>\n<\/tr>\n
17<\/td>\n5. ADSS application requirements and recommendations
5.1 Cable design characteristics <\/td>\n<\/tr>\n
18<\/td>\n5.2 Mechanical requirements
5.2.1 Sag and tension performance
5.2.2 Vibration performance
5.3 On-site optical acceptance testing <\/td>\n<\/tr>\n
19<\/td>\n5.4 Environmental pollution
5.5 Low pollution installation sites
5.5.1 High pollution installation sites <\/td>\n<\/tr>\n
20<\/td>\n5.6 Installation
5.7 Hardware
5.8 Packaging <\/td>\n<\/tr>\n
21<\/td>\n5.9 Electrical requirements (electric fields, corona, pollution)
5.9.1 Electric field performance
5.9.2 Corona performance
5.9.3 Pollution performance <\/td>\n<\/tr>\n
22<\/td>\n6. Tests and requirements
6.1 Classification of tests <\/td>\n<\/tr>\n
23<\/td>\n6.2 Procedure for optical measurements and fiber preparation
6.2.1 Optical measurements <\/td>\n<\/tr>\n
24<\/td>\n6.2.2 Fibers to be measured
6.2.3 Cable family definition <\/td>\n<\/tr>\n
25<\/td>\n6.2.4 Design changes
6.3 Retesting
6.4 Optical acceptance test
6.4.1 Attenuation coefficient
6.4.2 Point discontinuity
6.5 Qualification tests
6.5.1 Cable characteristics tests
6.5.1.1 Creep test <\/td>\n<\/tr>\n
26<\/td>\n6.5.1.2 Cable tensile and cyclic stress strain tests <\/td>\n<\/tr>\n
28<\/td>\n6.5.1.3 Strength element stress strain fatigue test
6.5.2 Installation tests
6.5.2.1 Sheave Test <\/td>\n<\/tr>\n
30<\/td>\n6.5.2.2 Crush test
6.5.2.3 Low\/high temperature bend test <\/td>\n<\/tr>\n
31<\/td>\n6.5.2.4 Twist test
6.5.2.5 Cable cyclic flexing <\/td>\n<\/tr>\n
32<\/td>\n6.5.2.6 Cable impact
6.5.2.7 Seepage of flooding or filling compound test <\/td>\n<\/tr>\n
33<\/td>\n6.5.3 In-service tests
6.5.3.1 Aeolian vibration test <\/td>\n<\/tr>\n
35<\/td>\n6.5.3.2 Galloping test <\/td>\n<\/tr>\n
37<\/td>\n6.5.3.3 Water ingress test <\/td>\n<\/tr>\n
38<\/td>\n6.5.3.4 Mid-span buffer tube storage test
6.5.3.5 Temperature cycling test <\/td>\n<\/tr>\n
39<\/td>\n6.5.4 Electrical test\u2014Dry band arcing resistance <\/td>\n<\/tr>\n
41<\/td>\nAnnex A (informative) Comments on electrical revision <\/td>\n<\/tr>\n
45<\/td>\nB.2.2 Example structure designs that may require non-parallel (3D Electric Field) analysis for location of ADSS cable dead-ends and suspensions <\/td>\n<\/tr>\n
48<\/td>\nAnnex D (informative) An overview of pollution model and electrical test <\/td>\n<\/tr>\n
53<\/td>\nAnnex E (informative) Dry Band Arcing test procedure <\/td>\n<\/tr>\n
56<\/td>\nAnnex F (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2011<\/td>\n56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":397758,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-397753","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/397753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/397758"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=397753"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=397753"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=397753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}