{"id":80533,"date":"2024-10-17T18:45:15","date_gmt":"2024-10-17T18:45:15","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-101-1984\/"},"modified":"2024-10-24T19:43:50","modified_gmt":"2024-10-24T19:43:50","slug":"ieee-c37-101-1984","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-101-1984\/","title":{"rendered":"IEEE C37.101 1984"},"content":{"rendered":"
New IEEE Standard – Inactive – Superseded. Guidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is provided.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | I. Introduction Summary of Protection Schemes <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | SchemeNumbers <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5 GroundingMethods <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Method I Distribution-Transformer Grounded (High Resistance Method 11 Neutral-Resistor Grounded (High Resistance) Method 111 Neutral-Resistor Grounded (Low Resistance Method IV Neutral-Reactor Grounded (Low Inductive Reactance) 5.5 Method V Ground-Fault Neutralizer Grounded (Tuned Inductive Reactor Method VI Grounding Transformer Grounded (High Resistance) <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Method VII Grounding Transformer Grounded (Medium Resistance) Method VIII Ungrounded 6 Protective Schemes <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Scheme 1 Ground Overvoltage-Complete Shutdown Scheme 1 Ground Overvoltage-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Scheme 2 Ground Overvoltage-Permissive Shutdown <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Scheme 3 Ground Overvoltage-Alarm and Time-Delay Shutdown Scheme 4 Ground Overvoltage-Alarm Scheme 5S Startup Ground Overvoltage-Complete Shutdown Scheme 2 Ground Overvoltage-Permissive Shutdown Scheme 3 Ground Overvoltage-Alarm and Time-Delay Shutdown Scheme 4 Ground Overvoltage-Alarm <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Orderly ShuMown Scheme 5s Startup Ground Overvoltage-Complete Shutdown Orderly Shutdown <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Overvoltage-Complete Shutdown Scheme 7 Wye-Broken-Delta VT Ground Overvoltage-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Overvoltage-Complete Shutdown Ground Overcurrent-Complete Shutdown Shutdown Complete Shutdown <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Ground Overcurrent-Complete Shutdown Shutdown,orBoth CompleteShutdown <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Scheme 12 Generator Leads Ground Overcurrent-Complete Shutdown Complete Shutdown or Both Scheme 12 Generator Leads Ground Overcurrent-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Instantaneous Ground Overcurrent-Complete Shutdown Overcurrent-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Instantaneous Ground Overcurrent-Complete Shutdown Scheme 15 Generator Percentage Differential-Complete Shutdown Overcurrent-Complete Shutdown Overcurrent-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Differential- Complete Shutdown Scheme 15 Generator Percentage Differential-Complete Shutdown Overcurrent-Complete Shutdown <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Protective Device Function Numbers Complete Shutdown <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Generator-Ground Protection; Other Practices <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Scheme A 3rd Harmonic Neutral Voltage <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Scheme B 3rd Harmonic Terminal to Ground Residual Voltage <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Scheme C 3rd Harmonic Ratio Differential Quantities Scheme D Neutral or Residual Voltage Injection <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | GroundFaults <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Scheme F Residual High-Impedance Generator Differential Percentage Differential <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Generator Ground Protection Examples Typical Generator Ground Protection One Line Diagram <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Phase to Ground-Fault Symmetrical Component Equivalent Circuits <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | PhasorDiagrams <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Relay and Fuse Coordination Curves <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Appendix C Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Guide for Generator Ground Protection<\/b><\/p>\n |